An RS-232 transceiver is an interface IC that converts logic-level signals from a host, controller, or peripheral into RS-232 line levels and converts received RS-232 signals back into logic levels. Within the interface hierarchy, the MAX202EPE+ belongs to the RS-232 transceiver class, which is part of interface ICs and broader semiconductor communication components. Its integrated charge-pump circuitry eliminates the need for a separate ±12V supply, making it suitable for systems that operate from a single +5V rail.
The principal features include two RS-232 drivers, two RS-232 receivers, operation from a 4.5V to 5.5V supply, and data rates above 120kbps. Four external 0.1µF capacitors support the on-chip charge-pump function. The MAX202EPE+ temperature range is -40°C to +85°C, and its listed human-body-model ESD withstand is 15kV, making it appropriate for industrial and instrumentation interfaces that require protection beyond basic logic ICs.
Internally, the MAX202EPE+ combines a practical RS-232 interface with a switched-capacitor charge pump. The charge pump generates the positive and negative signal levels required by the drivers while the receivers detect and translate incoming line states. Because the receiver and driver counts are both two, the device can support two serial channels in one package. The 16-pin PDIP construction favors straightforward through-hole assembly, prototype boards, legacy equipment, and repair applications where a surface-mount package would require different tooling.
Typical applications include two-channel serial links between industrial controllers and test equipment, PC and peripheral connectivity through an RS-232 port, point-to-point data acquisition links, and legacy instrumentation interfaces. It is particularly useful where the design has only a +5V supply but the connected equipment expects RS-232 signal levels. The 120kbps capability is suitable for configuration, monitoring, and control traffic rather than high-bandwidth continuous data transfer.
Circuit implementation requires close attention to charge-pump capacitor placement and signal routing. Place all four 0.1µF capacitors near their associated pins, keep high-current charge-pump paths compact, and provide adequate ground return paths for receiver and driver currents. Confirm that the connected equipment uses compatible RS-232 levels and that the intended baud rate remains below the device's 120kbps capability.
This page consolidates the manufacturer's product information, interface characteristics, replacement analysis, application guidance, and package-level design considerations into one engineering-focused reference. It also distinguishes the MAX202EPE+ from other MAX202 temperature and package options while keeping the comparison focused on genuine pin-compatible choices.
جێگرەوەکانی جێگۆڕکێ بۆ MAX202EPE+ — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ MAX202EPE+ (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Mounting Type, Package, Interface Standard, Product Type, Maximum Data Rate.
MAX202CPE+
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوەپەیوەندی بۆ نرخ
بینینی داتاشیت →MAX202CPE+
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوەپەیوەندی بۆ نرخ
بینینی داتاشیت →MAX202EJE+
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
MAX202CJE+
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
MAX202EPE
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
MAX202EPE+ تایبەتمەندییەکان
| Product Type | Dual-driver, dual-receiver RS-232 transceiver |
| Supply Voltage Range | 4.5V to 5.5V |
| Nominal Supply Voltage | 5V |
| Minimum Logic Voltage | 5V |
| Maximum Data Rate | 120kbps |
| Maximum Data Rate | 0.12Mbps |
| Number of Drivers | 2 |
| Number of Receivers | 2 |
| External Charge-Pump Capacitors | 4 x 0.1µF |
| Interface Standard | RS-232 |
| Signal-Level Standard | EIA/TIA-232E |
| Related Interface | V.28 |
| پاکێج | 16-pin PDIP |
| جۆری دامەزراندن | Through-hole |
| مەودای پلەی گەرمیی کارکردن | -40°C to +85°C |
| ESD withstand, Human Body Model | 15kV |
ڕێنمایی ڕێکخستنی پینی MAX202EPE+ 16-pin pdip
ڕێکخستنی پین بۆ MAX202EPE+ (پاکێجی 16-pin pdip). ژمارەدانی پین، فەنکشنەکان و نەخشەکانی پەیوەندی لە داتاشیتی بەرھەمھێنەردا پێناسە کراون. سەرنجی بدە بۆ شوێنپێی ورد و ڕێنمایییەکانی لەحیمکردن.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ MAX202EPE+.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
MAX202EPE+ گونجاوە بۆ 6 بەکارھێنانs: Industrial Controller Serial Links, Test and Measurement Equipment, Point-to-Point Data Acquisition, Legacy PC and Peripheral Connectivity, Embedded Serial Debug Interface, Automated Test Equipment Control.
Industrial Controller Serial Links
The MAX202EPE+ fits industrial controller and peripheral connections that require RS-232 levels from a single +5V rail. Its two drivers and two receivers can implement one full-duplex channel or multiple single-ended links, while the 120kbps rate is appropriate for supervisory commands, status polling, and configuration traffic. The -40°C to +85°C range supports equipment operating across extended industrial temperature conditions. Place the four required 0.1µF charge-pump capacitors close to their associated pins and route driver and receiver returns carefully to prevent ground disturbances from coupling into sensitive serial measurements.
پێشنیارکراو
Test and Measurement Equipment
The MAX202EPE+ is useful in test and measurement equipment that connects older RS-232 instruments to a +5V controller. The integrated charge-pump circuitry eliminates a separate ±12V supply, while the 120kbps data rate is well suited to command sequences, measurement results, and remote instrument control. Its listed 15kV human-body-model ESD withstand adds interface robustness for bench and field equipment. Designers should maintain a direct ground reference between communicating systems, use shielded cable where appropriate, and keep high-current charge-pump current away from sensitive receiver traces.
پێشنیارکراو
Point-to-Point Data Acquisition
The MAX202EPE+ can bridge a data-acquisition controller and an RS-232-compatible instrument when only one +5V supply is available. Two transmitters and two receivers provide enough channels for a full-duplex link, and the 120kbps capability supports sampled status and control data rather than continuous high-rate transfer. The through-hole PDIP package also simplifies installation in laboratory adapters and legacy measurement platforms. For reliable operation, use the manufacturer's recommended capacitor placement, keep the communication ground adjacent to the signal return, and verify that the remote equipment does not use RS-422 or RS-485 signal levels.
پێشنیارکراو
Legacy PC and Peripheral Connectivity
The MAX202EPE+ is appropriate for adding an RS-232 port to a +5V legacy controller or peripheral system without a bipolar power supply. Its EIA/TIA-232E-compatible driver levels and 120kbps operation fit typical serial-console, configuration-port, and service-interface applications. The 16-pin PDIP package is useful for repair boards and prototypes where surface-mount rework is inconvenient. Confirm that the host uses true RS-232 rather than TTL-level UART signals, connect only the required receive and drive lines, and maintain consistent reference ground between systems to avoid undefined voltage conditions.
پێشنیارکراو
Embedded Serial Debug Interface
The MAX202EPE+ can provide an isolated-by-convention RS-232 debug port for embedded equipment operating from a +5V rail. It is well matched to boot logs, diagnostics, configuration exchanges, and service commands that do not require throughput beyond 120kbps. The dual-driver and dual-receiver arrangement offers flexibility in cable and handshake connections, while the PDIP package allows straightforward prototype integration. Design the interface so that the RS-232 transceiver is electrically distinct from the low-voltage UART domain, and use ESD-aware external protection and cable practices where operators may connect unprotected field leads.
پێشنیارکراو
Automated Test Equipment Control
The MAX202EPE+ fits automated test equipment that must communicate with older serial fixtures or instruments through an RS-232 control port. A single +5V supply simplifies the fixture architecture, and the 120kbps rate supports command sequencing, pass-fail results, and equipment status. Its listed -40°C to +85°C operating range covers industrial test environments, while the 15kV human-body-model ESD rating supports robust connector-facing implementation. To avoid communication errors, terminate unused driver outputs appropriately, verify the remote equipment's baud rate and parity settings, and keep charge-pump traces away from sensitive analog measurement sections.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ MAX202EPE+ — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | MAX202CPE+ | MAX202CPE | MAX202EJE+ | MAX202CJE+ | MAX202EPE |
|---|---|---|---|---|---|---|
| Brand | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated |
| Package | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP |
| Product Type | Dual-driver, dual-receiver RS-232 transceiver | MAX202-family dual RS-232 transceiver | MAX202-family dual RS-232 transceiver | MAX202-family dual RS-232 transceiver | MAX202-family dual RS-232 transceiver | MAX202-family dual RS-232 transceiver |
| Supply Voltage Range | 4.5V to 5.5V | 4.5V to 5.5V | 4.5V to 5.5V | 4.5V to 5.5V | 4.5V to 5.5V | 4.5V to 5.5V |
| Nominal Supply Voltage | 5V | 5V | 5V | 5V | 5V | 5V |
| Maximum Data Rate | 120kbps | 120kbps | 120kbps | 120kbps | 120kbps | 120kbps |
| Drivers | 2 | 2 | 2 | 2 | 2 | 2 |
| Receivers | 2 | 2 | 2 | 2 | 2 | 2 |
| External Capacitors | 4 x 0.1µF | 4 x 0.1µF | 4 x 0.1µF | 4 x 0.1µF | 4 x 0.1µF | 4 x 0.1µF |
| Package Construction | Plastic PDIP | Plastic PDIP | Plastic PDIP | Ceramic PDIP | Ceramic PDIP | Plastic PDIP |
جیاکەرەوە سەرەکییەکان
- Extended industrial temperature capability (بەراورد بەMAX202CPE+)
- Plastic package combines temperature capability with lower-cost construction (بەراورد بەMAX202EJE+)
- Single-supply RS-232 operation with integrated charge pump (بەراورد بەMAX202CPE)
تێبینییەکانی دیزاین
Place all four required 0.1µF charge-pump capacitors directly beside their associated MAX202EPE+ pins, using the manufacturer datasheet's recommended circuit as the layout reference. Keep capacitor and charge-pump current loops compact because long traces add loop area and can increase radiated emissions or susceptibility to coupling. Use a solid ground plane for the IC and connect the capacitor return paths without sharing narrow neck routes with receiver return currents.
Keep the RS-232 receiver traces short and route them away from driver outputs, switching supplies, and clocked digital signals. The two receiver inputs are sensitive to common-mode noise even though the interface uses differential bipolar signaling. Provide a continuous signal-ground path between communicating systems, use twisted or shielded cable for longer runs, and confirm that the remote equipment uses RS-232 rather than TTL UART or RS-485 levels.
Do not omit the external charge-pump capacitors, substitute RS-485 termination resistors for the RS-232 interface, or connect the MAX202EPE+ directly to a TTL-level UART without recognizing that the transceiver performs voltage conversion. Also avoid assuming that every MAX202 orderable variant has the same temperature grade or package material. Verify the exact suffix, check the pin description, and confirm the external capacitor values before releasing a PCB or approving a replacement.
Treat the charge-pump section as a potential high-current switching source even though the part communicates through relatively slow RS-232 signals. Route charge-pump connections directly to their capacitors, avoid routing those paths beneath analog or communication traces, and maintain an uninterrupted ground plane beneath the device. If the enclosure permits radiated emissions above the applicable product limits, inspect cable shielding, connector grounding, and adjacent switching-converter layout before adding arbitrary filtering.
زانیاری پابەندبوون
The accessible product and comparison excerpts mention RoHS and REACH status but do not provide a definitive compliance result. The '+' ordering designation should not be treated as a substitute for the manufacturer's current material-compliance declaration.