Maxim Integrated

MAX202EPE+ - 120kbps RS-232 Transceiver | Maxim Integrated

MPN: MAX202EPE+ ✓ چالاک
4.5V to 5.5V Vdss 16-pin PDIP Package
MOQ: 1 |

MAX202EPE+ گشتی

The Maxim Integrated MAX202EPE+ is a dual-driver, dual-receiver RS-232 interface transceiver designed for single-supply operation from 4.5V to 5.5V. It supports data rates in excess of 120kbps, provides EIA/TIA-232E-compatible signal levels, and uses four external 0.1µF charge-pump capacitors. The device is packaged in a 16-pin PDIP.

An RS-232 transceiver is an interface IC that converts logic-level signals from a host, controller, or peripheral into RS-232 line levels and converts received RS-232 signals back into logic levels. Within the interface hierarchy, the MAX202EPE+ belongs to the RS-232 transceiver class, which is part of interface ICs and broader semiconductor communication components. Its integrated charge-pump circuitry eliminates the need for a separate ±12V supply, making it suitable for systems that operate from a single +5V rail.

The principal features include two RS-232 drivers, two RS-232 receivers, operation from a 4.5V to 5.5V supply, and data rates above 120kbps. Four external 0.1µF capacitors support the on-chip charge-pump function. The MAX202EPE+ temperature range is -40°C to +85°C, and its listed human-body-model ESD withstand is 15kV, making it appropriate for industrial and instrumentation interfaces that require protection beyond basic logic ICs.

Internally, the MAX202EPE+ combines a practical RS-232 interface with a switched-capacitor charge pump. The charge pump generates the positive and negative signal levels required by the drivers while the receivers detect and translate incoming line states. Because the receiver and driver counts are both two, the device can support two serial channels in one package. The 16-pin PDIP construction favors straightforward through-hole assembly, prototype boards, legacy equipment, and repair applications where a surface-mount package would require different tooling.

Typical applications include two-channel serial links between industrial controllers and test equipment, PC and peripheral connectivity through an RS-232 port, point-to-point data acquisition links, and legacy instrumentation interfaces. It is particularly useful where the design has only a +5V supply but the connected equipment expects RS-232 signal levels. The 120kbps capability is suitable for configuration, monitoring, and control traffic rather than high-bandwidth continuous data transfer.

Circuit implementation requires close attention to charge-pump capacitor placement and signal routing. Place all four 0.1µF capacitors near their associated pins, keep high-current charge-pump paths compact, and provide adequate ground return paths for receiver and driver currents. Confirm that the connected equipment uses compatible RS-232 levels and that the intended baud rate remains below the device's 120kbps capability.

This page consolidates the manufacturer's product information, interface characteristics, replacement analysis, application guidance, and package-level design considerations into one engineering-focused reference. It also distinguishes the MAX202EPE+ from other MAX202 temperature and package options while keeping the comparison focused on genuine pin-compatible choices.

جێگرەوەکانی جێگۆڕکێ بۆ MAX202EPE+ — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.

جۆرەکان لەم زنجیرەیەدا

مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ MAX202EPE+ (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Mounting Type, Package, Interface Standard, Product Type, Maximum Data Rate.

Analog Devices
Mounting Type: Surface mount
Package: 16-pin SOIC
Interface Standard: TIA/EIA-232-E and V.28
بەراوردکردن لەگەڵ MAX202EPE+ →
Analog Devices
Mounting Type: Through-Hole (THT)
Package: 16-PDIP (through-hole, 0.300 inch / 7.62 mm row spacing)
بەراوردکردن لەگەڵ MAX202EPE+ →
Analog Devices
Interface Standard: EIA/TIA-232E, V.28, and V.24
Product Type: Dual RS-232 transceiver with integrated charge-pump converter
بەراوردکردن لەگەڵ MAX202EPE+ →

MAX202CPE+

✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە
Analog Devices
📦 16-pin PDIP
RS-232 Transceiver (2 Drivers / 2 Receivers) · 120 kbps (min) · +4.5 V to +5.5 V · 15 mA (typ) · 4 x 0.1 uF · +/-5 V EIA/TIA-232E compliant · +/-25 V · 0.5 V (typ)

پەیوەندی بۆ نرخ

بینینی داتاشیت →

MAX202CPE+

✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە
Analog Devices
📦 16-pin PDIP
RS-232 Transceiver (2 Drivers / 2 Receivers) · 120 kbps (min) · +4.5 V to +5.5 V · 15 mA (typ) · 4 x 0.1 uF · +/-5 V EIA/TIA-232E compliant · +/-25 V · 0.5 V (typ)

پەیوەندی بۆ نرخ

بینینی داتاشیت →

MAX202EJE+

✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە
📦 16-pin PDIP
The ceramic-package construction replaces the plastic construction of MAX202EPE+, while the family-level 120kbps RS-232 interface and 16-pin PDIP pin arrangement remain compatible.

📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)

MAX202CJE+

✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە
📦 16-pin PDIP
Ceramic-package construction is paired with a commercial-temperature grade rather than the -40°C to +85°C rating of MAX202EPE+; core two-driver, two-receiver RS-232 functions remain the same.

📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)

MAX202EPE

✅ جێگرەوەی ڕاستەوخۆ
📦 16-pin PDIP
Electrical ratings match the 120kbps, dual-driver, dual-receiver MAX202 architecture; the ordering distinction is the legacy designation without the '+' suffix.

📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)

MAX202EPE+ تایبەتمەندییەکان

Product Type Dual-driver, dual-receiver RS-232 transceiver
Supply Voltage Range 4.5V to 5.5V
Nominal Supply Voltage 5V
Minimum Logic Voltage 5V
Maximum Data Rate 120kbps
Maximum Data Rate 0.12Mbps
Number of Drivers 2
Number of Receivers 2
External Charge-Pump Capacitors 4 x 0.1µF
Interface Standard RS-232
Signal-Level Standard EIA/TIA-232E
Related Interface V.28
پاکێج 16-pin PDIP
جۆری دامەزراندن Through-hole
مەودای پلەی گەرمیی کارکردن -40°C to +85°C
ESD withstand, Human Body Model 15kV

ڕێنمایی ڕێکخستنی پینی MAX202EPE+ 16-pin pdip

ڕێکخستنی پین بۆ MAX202EPE+ (پاکێجی 16-pin pdip). ژمارەدانی پین، فەنکشنەکان و نەخشەکانی پەیوەندی لە داتاشیتی بەرھەمھێنەردا پێناسە کراون. سەرنجی بدە بۆ شوێنپێی ورد و ڕێنمایییەکانی لەحیمکردن.

نەخشەی پینئاوتی پاکێجی 16-pin pdip بۆ MAX202EPE+

هیچ داتای وردی پینئاوت بەردەست نییە بۆ MAX202EPE+.

سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.

بەکارهێنانە باوەکان

MAX202EPE+ گونجاوە بۆ 6 بەکارھێنانs: Industrial Controller Serial Links, Test and Measurement Equipment, Point-to-Point Data Acquisition, Legacy PC and Peripheral Connectivity, Embedded Serial Debug Interface, Automated Test Equipment Control.

🏭

Industrial Controller Serial Links

The MAX202EPE+ fits industrial controller and peripheral connections that require RS-232 levels from a single +5V rail. Its two drivers and two receivers can implement one full-duplex channel or multiple single-ended links, while the 120kbps rate is appropriate for supervisory commands, status polling, and configuration traffic. The -40°C to +85°C range supports equipment operating across extended industrial temperature conditions. Place the four required 0.1µF charge-pump capacitors close to their associated pins and route driver and receiver returns carefully to prevent ground disturbances from coupling into sensitive serial measurements.

🔧

Test and Measurement Equipment

The MAX202EPE+ is useful in test and measurement equipment that connects older RS-232 instruments to a +5V controller. The integrated charge-pump circuitry eliminates a separate ±12V supply, while the 120kbps data rate is well suited to command sequences, measurement results, and remote instrument control. Its listed 15kV human-body-model ESD withstand adds interface robustness for bench and field equipment. Designers should maintain a direct ground reference between communicating systems, use shielded cable where appropriate, and keep high-current charge-pump current away from sensitive receiver traces.

📡

Point-to-Point Data Acquisition

The MAX202EPE+ can bridge a data-acquisition controller and an RS-232-compatible instrument when only one +5V supply is available. Two transmitters and two receivers provide enough channels for a full-duplex link, and the 120kbps capability supports sampled status and control data rather than continuous high-rate transfer. The through-hole PDIP package also simplifies installation in laboratory adapters and legacy measurement platforms. For reliable operation, use the manufacturer's recommended capacitor placement, keep the communication ground adjacent to the signal return, and verify that the remote equipment does not use RS-422 or RS-485 signal levels.

🖥️

Legacy PC and Peripheral Connectivity

The MAX202EPE+ is appropriate for adding an RS-232 port to a +5V legacy controller or peripheral system without a bipolar power supply. Its EIA/TIA-232E-compatible driver levels and 120kbps operation fit typical serial-console, configuration-port, and service-interface applications. The 16-pin PDIP package is useful for repair boards and prototypes where surface-mount rework is inconvenient. Confirm that the host uses true RS-232 rather than TTL-level UART signals, connect only the required receive and drive lines, and maintain consistent reference ground between systems to avoid undefined voltage conditions.

📱

Embedded Serial Debug Interface

The MAX202EPE+ can provide an isolated-by-convention RS-232 debug port for embedded equipment operating from a +5V rail. It is well matched to boot logs, diagnostics, configuration exchanges, and service commands that do not require throughput beyond 120kbps. The dual-driver and dual-receiver arrangement offers flexibility in cable and handshake connections, while the PDIP package allows straightforward prototype integration. Design the interface so that the RS-232 transceiver is electrically distinct from the low-voltage UART domain, and use ESD-aware external protection and cable practices where operators may connect unprotected field leads.

📺

Automated Test Equipment Control

The MAX202EPE+ fits automated test equipment that must communicate with older serial fixtures or instruments through an RS-232 control port. A single +5V supply simplifies the fixture architecture, and the 120kbps rate supports command sequencing, pass-fail results, and equipment status. Its listed -40°C to +85°C operating range covers industrial test environments, while the 15kV human-body-model ESD rating supports robust connector-facing implementation. To avoid communication errors, terminate unused driver outputs appropriately, verify the remote equipment's baud rate and parity settings, and keep charge-pump traces away from sensitive analog measurement sections.

کورتەی بەرهەمە پێشنیارکراوەکان

MAX211 MAX202-family RS-232 transceiver option بەکارهێنراوە لە: Industrial Controller Serial Links, Test and Measurement Equipment, Point-to-Point Data Acquisition, Legacy PC and Peripheral Connectivity, Embedded Serial Debug Interface, Automated Test Equipment Control MAX213 MAX202-family RS-232 transceiver option بەکارهێنراوە لە: Industrial Controller Serial Links, Test and Measurement Equipment, Point-to-Point Data Acquisition, Legacy PC and Peripheral Connectivity, Embedded Serial Debug Interface, Automated Test Equipment Control
What is the MAX202EPE+?
The MAX202EPE+ is a dual-driver, dual-receiver RS-232 transceiver that operates from a single 4.5V to 5.5V supply. According to the Maxim Integrated MAX202 datasheet, its integrated charge-pump circuitry supports EIA/TIA-232E signal levels without requiring a separate ±12V supply. The device also provides data rates in excess of 120kbps and is packaged in a 16-pin PDIP.
What are the key specifications of MAX202EPE+ that engineers should know?
The MAX202EPE+ provides two drivers, two receivers, a 4.5V to 5.5V operating range, and data rates above 120kbps. According to the Maxim Integrated MAX202 datasheet, four external 0.1µF capacitors are required for charge-pump operation. Its 16-pin PDIP package supports through-hole assembly, while the specified operating-temperature range is -40°C to +85°C.
What supply voltage does MAX202EPE+ require?
The MAX202EPE+ operates from a single 4.5V to 5.5V supply, with 5V as the nominal operating voltage. According to the Maxim Integrated MAX202 datasheet, integrated charge-pump circuitry generates the bipolar signal levels needed by the RS-232 drivers. This removes the need for a separate ±12V supply and simplifies the power architecture of equipment using conventional +5V logic.
What is the maximum data rate of MAX202EPE+?
The MAX202EPE+ supports RS-232 data rates in excess of 120kbps, equivalent to 0.12Mbps. According to the Maxim Integrated MAX202 datasheet, the drivers maintain EIA/TIA-232E output levels at those rates when loaded in accordance with the standard. It is suitable for configuration, monitoring, and control links rather than continuous high-bandwidth transfers.
Where can I download the MAX202EPE+ datasheet PDF?
The official MAX202 datasheet is available from the Maxim Integrated product page linked on this page, which is hosted by Analog Devices. The manufacturer datasheet describes the +5V RS-232 architecture, EIA/TIA-232E operation, 120kbps performance, external capacitor requirements, and available packages. Use the manufacturer's document to confirm the exact pin assignment and electrical limits before PCB release.
Where can I find the MAX202EPE+ pinout?
The MAX202EPE+ pin assignment is defined in the pin-description section of the Maxim Integrated MAX202 datasheet. The part uses a 16-pin PDIP package, so its footprint follows the standard 16-pin dual-inline arrangement. Use that table when assigning supply, ground, driver outputs, receiver inputs, and the four external charge-pump capacitor connections.
How many external capacitors does MAX202EPE+ need?
The MAX202EPE+ requires four external 0.1µF capacitors for its charge-pump function. According to the Maxim Integrated MAX202 datasheet, these capacitors must be connected to the designated charge-pump pins. Their electrical capacitance, voltage rating, and tolerance should follow the manufacturer's recommendations, and their placement should minimize trace length between each capacitor and its associated device pin.
Is MAX202EPE+ suitable for industrial instrumentation?
The MAX202EPE+ is suitable for many industrial instrumentation interfaces because it combines a 4.5V to 5.5V supply range, 120kbps data capability, and a -40°C to +85°C operating range. According to the Maxim Integrated MAX202 datasheet, the device also has a listed 15kV human-body-model ESD withstand. It is appropriate for equipment where RS-232 is required but a surface-mount package or separate bipolar supply is undesirable.
What is the difference between MAX202EPE+ and MAX202CPE+?
The principal difference between MAX202EPE+ and MAX202CPE+ is their specified temperature range: MAX202EPE+ operates from -40°C to +85°C, while MAX202CPE+ is associated with the 0°C to +70°C commercial-temperature range. The MAX202EPE+ comparison data identifies the same 120kbps transceiver architecture, two drivers, two receivers, and 5V nominal supply. Both use the 16-pin PDIP footprint and therefore can support pin-compatible upgrades when temperature requirements allow.
MAX202EPE+ vs MAX232EPE - which is better for a +5V RS-232 link?
The MAX202EPE+ is the direct choice when a two-driver, two-receiver, single +5V RS-232 transceiver is required. The MAX232EPE+ comparison also uses a 16-pin PDIP and provides the same basic 120kbps RS-232 interface, but it does not provide the MAX202's power-management features. Choose the MAX202EPE+ when its additional control capability is useful; otherwise, review both datasheets for the exact pin functions and shutdown behavior required by the design.
When should I choose MAX202EPE+ over MAX202EJE+?
Choose MAX202EPE+ for conventional through-hole industrial or commercial equipment operating from -40°C to +85°C. Choose the MAX202EJE+ when its ceramic-package construction and associated environmental or longevity requirements justify the higher-cost mechanical option. Both belong to the MAX202 family and use the same 16-pin PDIP electrical architecture, so verify the temperature grade, package material, availability, and solder or termination process before selecting either device.
Is MAX202EPE+ suitable for a point-to-point serial data link?
The MAX202EPE+ is suitable for a point-to-point RS-232 link when the required baud rate remains below 120kbps. It provides two drivers and two receivers, so it can support one full-duplex channel or two channels depending on the wiring arrangement. The single 5V supply and integrated charge pump simplify portable and legacy systems, while the external 0.1µF capacitors must be placed close to the device.
What can replace MAX202EPE+?
The closest pin-compatible replacements are temperature-grade and package-material variants of the same MAX202 family, including MAX202CPE+, MAX202CPE, and MAX202EJE+. Each candidate retains the 16-pin PDIP footprint, two transmitters, two receivers, 120kbps-class operation, and a single +5V supply architecture. Confirm temperature range, ceramic or plastic construction, lifecycle status, and exact pin functions before approving a substitution.
Is MAX202EPE+ the same as MAX202EPE?
MAX202EPE+ and MAX202EPE denote closely related orderable forms of the MAX202EPE 16-pin PDIP device. The MAX202EPE datasheet covers the electrical family, while the '+' ordering code identifies the lead-free commercial designation commonly used by the manufacturer. Engineers should compare the current ordering information and package markings rather than assuming that the presence or absence of '+' changes the circuit function.
Where can I buy MAX202EPE+ online and what is its price?
The MAX202EPE+ can be requested through the Request a Quote form on this page, where current commercial terms, stock status, and lead time should be confirmed before ordering. Pricing changes with quantity, package form, market conditions, and inventory, so a static price figure would not be dependable. The exact MPN and required quantity should be stated on the request to obtain an actionable quotation.
What is the lead time for MAX202EPE+?
The current lead time for MAX202EPE+ should be requested through the Request a Quote form on this page by identifying the exact MPN, quantity, and target shipment date. Lead time can vary with manufacturer inventory, component demand, and the selected order quantity. The Request a Quote workflow allows purchasing to confirm the current schedule without relying on potentially stale availability information.
Is MAX202EPE+ in stock?
Current MAX202EPE+ inventory status should be confirmed through the Request a Quote form on this page. Because stock levels and lead times change, the form should be used to request the exact quantity and delivery schedule. The device remains listed by the manufacturer as a MAX202-family product, but a current manufacturing or distribution commitment must be established before inventory is assigned to a build.
Does MAX202EPE+ meet RoHS and REACH requirements?
The MAX202EPE+ ordering information must be checked for its current environmental declarations before a compliance claim is finalized. The MAX202EPE+ comparison data discusses RoHS and REACH status, but the accessible product excerpts do not state a definitive result. Review the manufacturer declaration or material-compliance record associated with the exact orderable MPN and retain that record for audit and procurement purposes.

داتای سەرچاوەی ئەندازیاری بۆ MAX202EPE+ — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.

ڕێنمایی هەڵبژاردن

Choose MAX202EPE+ for a +5V, 120kbps RS-232 interface assembled on a through-hole PCB, particularly when operation from -40°C to +85°C is required and a plastic PDIP is preferred. Choose MAX202CPE+ or MAX202CPE when the equipment remains between 0°C and +70°C and the lower-temperature commercial grade is sufficient. Choose MAX202EJE+ when ceramic-package construction justifies the additional cost or satisfies a specific environmental requirement; confirm its exact temperature rating in the manufacturer datasheet. Choose MAX202CJE+ when ceramic construction and the commercial-temperature grade are both required. MAX202EPE is a legacy-ordering alternative with the same core interface, but procurement should verify current lifecycle and material declarations. Regardless of suffix, the PCB must accept the 16-pin PDIP footprint and provide the four specified 0.1µF charge-pump capacitors.

بەراوردکردن لەگەڵ جێگرەوەکان

پارامەتر ئەم بەرهەمە MAX202CPE+ MAX202CPE MAX202EJE+ MAX202CJE+ MAX202EPE
Brand Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated
Package 16-pin PDIP 16-pin PDIP 16-pin PDIP 16-pin PDIP 16-pin PDIP 16-pin PDIP
Product Type Dual-driver, dual-receiver RS-232 transceiver MAX202-family dual RS-232 transceiver MAX202-family dual RS-232 transceiver MAX202-family dual RS-232 transceiver MAX202-family dual RS-232 transceiver MAX202-family dual RS-232 transceiver
Supply Voltage Range 4.5V to 5.5V 4.5V to 5.5V 4.5V to 5.5V 4.5V to 5.5V 4.5V to 5.5V 4.5V to 5.5V
Nominal Supply Voltage 5V 5V 5V 5V 5V 5V
Maximum Data Rate 120kbps 120kbps 120kbps 120kbps 120kbps 120kbps
Drivers 2 2 2 2 2 2
Receivers 2 2 2 2 2 2
External Capacitors 4 x 0.1µF 4 x 0.1µF 4 x 0.1µF 4 x 0.1µF 4 x 0.1µF 4 x 0.1µF
Package Construction Plastic PDIP Plastic PDIP Plastic PDIP Ceramic PDIP Ceramic PDIP Plastic PDIP

جیاکەرەوە سەرەکییەکان

  • Extended industrial temperature capability (بەراورد بەMAX202CPE+)
  • Plastic package combines temperature capability with lower-cost construction (بەراورد بەMAX202EJE+)
  • Single-supply RS-232 operation with integrated charge pump (بەراورد بەMAX202CPE)

تێبینییەکانی دیزاین

Place all four required 0.1µF charge-pump capacitors directly beside their associated MAX202EPE+ pins, using the manufacturer datasheet's recommended circuit as the layout reference. Keep capacitor and charge-pump current loops compact because long traces add loop area and can increase radiated emissions or susceptibility to coupling. Use a solid ground plane for the IC and connect the capacitor return paths without sharing narrow neck routes with receiver return currents.

Keep the RS-232 receiver traces short and route them away from driver outputs, switching supplies, and clocked digital signals. The two receiver inputs are sensitive to common-mode noise even though the interface uses differential bipolar signaling. Provide a continuous signal-ground path between communicating systems, use twisted or shielded cable for longer runs, and confirm that the remote equipment uses RS-232 rather than TTL UART or RS-485 levels.

Do not omit the external charge-pump capacitors, substitute RS-485 termination resistors for the RS-232 interface, or connect the MAX202EPE+ directly to a TTL-level UART without recognizing that the transceiver performs voltage conversion. Also avoid assuming that every MAX202 orderable variant has the same temperature grade or package material. Verify the exact suffix, check the pin description, and confirm the external capacitor values before releasing a PCB or approving a replacement.

Treat the charge-pump section as a potential high-current switching source even though the part communicates through relatively slow RS-232 signals. Route charge-pump connections directly to their capacitors, avoid routing those paths beneath analog or communication traces, and maintain an uninterrupted ground plane beneath the device. If the enclosure permits radiated emissions above the applicable product limits, inspect cable shielding, connector grounding, and adjacent switching-converter layout before adding arbitrary filtering.

زانیاری پابەندبوون

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
بێ قوڕقوشم
Unknown
بێ ھالۆجین
Unknown
کانزا ناکۆکەکان
Unknown

The accessible product and comparison excerpts mention RoHS and REACH status but do not provide a definitive compliance result. The '+' ordering designation should not be treated as a substitute for the manufacturer's current material-compliance declaration.

داتا پشتڕاستکراوەتەوە لە: 2026-11-02 — داتا لەلایەن تیمی ئەندازیاری پێکھاتەکانی XAIPART پشتڕاستکراوەتەوە و ڕێکخراوە

گەڕانە پەیوەندیدارەکان

max202epe datasheet MAX202EPE+ datasheet pdf MAX202EPE+ pinout MAX202EPE+ equivalent MAX202EPE+ replacement MAX202EPE+ cross reference MAX202EPE+ vs MAX202CPE+ MAX202EPE+ price MAX202EPE+ stock MAX202EPE+ 16-pin PDIP pinout MAX202EPE+ application circuit Maxim Integrated MAX202EPE+

پێکهاتە و زاراوە پەیوەندیدارەکان

Maxim Integrated Analog Devices MAX202EPE+ MAX202EPE MAX202CPE+ MAX202CPE MAX202EJE+ MAX202CJE+ MAX211 MAX213 RS-232 RS-232 transceiver EIA/TIA-232E V.28 interface IC semiconductor single-supply operation charge-pump circuitry 120kbps data rate 4.5V to 5.5V supply 0.1µF capacitor 16-pin PDIP through-hole package dual driver dual receiver human-body-model ESD
داواکاری نرخی خێرا RFQ
وردەکارییەکانی تەواو پڕ بکەرەوە — تیمی فرۆشتنی ئێمە لە ماوەی 24 کاتژمێردا وەڵام دەداتەوە
ژمارەی پارچە بەرهەمهێنەر پاکەت QTY نرخی ئامانج کۆی گشتی
✓
نرخەکە نێردرا!

لە ماوەی ٢٤ کاتژمێردا وەڵامی ئیمەیڵەکەت دەدەینەوە

1
داواکاری نرخ پێشکەشکرا
2
نرخپێدان وەرگیرا
3
داواکاری دانرا
4
پارەدان
5
نێردرا
6
گەیەنراوە
بینینی وردەکاریی داواکاری نرخ