TJA1049TK/3J - 3V to 5V High-Speed CAN Transceiver | NXP
MPN: TJA1049TK/3J ✓ چالاکTJA1049TK/3J گشتی
A CAN transceiver is an interface IC within the broader hierarchy of CAN interface, network interface, communications semiconductor, and integrated-circuit categories. Its transmit path converts controller logic into a differential bus signal, while its receive path converts the bus differential voltage into logic levels understood by the CAN controller. The TJA1049 is intended for high-speed CAN systems where low standby current and remote bus wake-up are useful.
Key device features include a very low-current Standby mode, bus wake-up capability, 3 V to 5 V operation, and support for microcontrollers using the same supply range. The TJA1049 implements the CAN physical layer associated with ISO 11898-2:2003, ISO 11898-5:2007, and the pending updated ISO 11898-2:2016 version identified by NXP. Its compact 8-HVSON package helps reduce PCB area in space-constrained automotive and industrial controller designs.
Technically, the device combines differential transmit and receive paths with controller-facing digital interfaces. High-speed operation makes it appropriate for conventional CAN networks carrying real-time control and diagnostic traffic. Standby operation reduces current demand when the node is inactive, while bus activity can wake the transceiver so that a low-power node can recognize a remote request without continuously driving the bus.
Typical applications include automotive body and powertrain controllers, industrial automation equipment, robotics, building automation, medical monitoring equipment, and embedded CAN gateways. In each case, the controller supplies TXD and receives RXD while the transceiver connects those logic signals to the differential CANH and CANL conductors.
When laying out the board, place the transceiver and its required support components near the bus connector or isolation boundary, and follow the manufacturer's pin and application-circuit guidance. Keep sensitive controller and analog circuitry away from the CAN bus traces, provide the prescribed supply decoupling, and account for bus termination only at appropriate network endpoints rather than at every node.
This page combines manufacturer specifications, functional application guidance, package details, and practical design considerations to help engineers evaluate the TJA1049TK/3J for a 3 V to 5 V CAN node. For current commercial availability, use the Request a Quote form on this page.
جێگرەوەکانی جێگۆڕکێ بۆ TJA1049TK/3J — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ TJA1049TK/3J (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Operating Temperature, Package, Product Type, Protocol, RoHS Status.
هیچ جێگرەوەی ڕاستەوخۆ بۆ ئەم بەرهەمە بەردەست نییە.
داوای جێگرەوەکان بکەTJA1049TK/3J تایبەتمەندییەکان
| Product Type | High-speed CAN transceiver with Standby mode |
| CAN Transceiver Type | 1/1 transceiver |
| Supply Voltage Range | 3 V to 5 V |
| CAN Bus | Differential two-wire CAN bus |
| Standby Mode | Very low-current Standby mode |
| Bus Wake-Up | Supported |
| Microcontroller Interface | Direct interface to 3 V to 5 V microcontrollers |
| Physical Layer | ISO 11898-2:2003, ISO 11898-5:2007, and pending updated ISO 11898-2:2016 |
| Transmit Capability | Differential |
| Receive Capability | Differential |
| پاکێج | 8-HVSON (3 x 3 mm) |
| جۆری دامەزراندن | Surface mount |
| Package Pin Count | 8 pins |
| دۆخی RoHS | Unknown |
| REACH Status | Unknown |
ڕێنمایی ڕێکخستنی پینی TJA1049TK/3J 8 pins
ڕێکخستنی پین بۆ TJA1049TK/3J (پاکێجی 8 pins). ژمارەدانی پین، فەنکشنەکان و نەخشەکانی پەیوەندی لە داتاشیتی بەرھەمھێنەردا پێناسە کراون. سەرنجی بدە بۆ شوێنپێی ورد و ڕێنمایییەکانی لەحیمکردن.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ TJA1049TK/3J.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
TJA1049TK/3J گونجاوە بۆ 6 بەکارھێنانs: Automotive Body Control Module, Industrial Automation Controller, Robotics Motor Network, Building Automation Sensor Node, Medical Monitoring Equipment, CAN Gateway and Data Logger.
Automotive Body Control Module
The TJA1049TK/3J fits automotive body-control and gateway nodes that use a local microcontroller with a 3 V to 5 V supply and need a compact CAN physical-layer interface. Its differential transmit and receive functions connect the controller to the two-wire CANH and CANL bus, while the 3 x 3 mm 8-HVSON package conserves board area. The very low-current Standby mode and bus wake-up capability are valuable when the module must reduce power demand yet respond to remote bus activity. The exact maximum data rate, transient protection, temperature range, and pin configuration should be confirmed in the NXP datasheet before qualification.
پێشنیارکراو
Industrial Automation Controller
The TJA1049TK/3J is suitable for industrial automation equipment that connects a CAN controller to sensors, drives, remote I/O, or service equipment over a differential bus. Operating from 3 V to 5 V allows direct use with common embedded controller supply rails, and the compact 8-HVSON footprint leaves more PCB area for isolation, protection, and signal conditioning. Standby mode can reduce power consumption during inactive intervals, while bus wake-up supports recovery when another node initiates communication. Designers should confirm the device's operating limits and implement the prescribed application-circuit component values and layout.
پێشنیارکراو
Robotics Motor Network
The TJA1049TK/3J can provide the physical bus interface in a robot controller, motor controller, or sensor node that exchanges commands and diagnostics over CAN. Its differential CAN paths support robust communication between the embedded controller and remote motor nodes, while the low-current Standby mode is useful for coordinated low-power operation. Bus wake-up allows a node to become responsive when network traffic resumes, avoiding the need to keep every controller fully active. Because robot systems can experience motor noise and long cable runs, follow the NXP interface guidance and validate grounding, protection, and termination with the complete system configuration.
پێشنیارکراو
Building Automation Sensor Node
The TJA1049TK/3J fits low-power building automation nodes such as room controllers, environmental monitors, and access-control interfaces. A 3 V to 5 V operating range supports common embedded supply architectures, while the 8-HVSON package helps reduce the footprint of densely distributed bus devices. The Standby mode lowers operating demand, and bus wake-up allows a sleeping node to react when another building controller initiates communication. The CAN controller must handle protocol functions, while the TJA1049 provides the physical-layer interface. Field qualification should include bus-level transient immunity, EMC, cable length, and network termination tests.
پێشنیارکراو
Medical Monitoring Equipment
The TJA1049TK/3J can serve as the isolated or non-isolated CAN physical interface in medical monitoring equipment, provided the complete device meets the applicable safety, EMC, and system-level requirements. Its 3 V to 5 V operation suits many embedded medical controllers, and the compact 8-HVSON package supports space-constrained instrument designs. Differential signaling supports reliable communication between monitoring, diagnostic, and central equipment over established CAN networks. Standby and bus wake-up can reduce power use without preventing the node from noticing network requests. The transceiver does not independently establish medical certification, so engineers must assess the finished equipment and required isolation architecture.
پێشنیارکراو
CAN Gateway and Data Logger
The TJA1049TK/3J is appropriate for a CAN gateway or industrial data logger that must bridge a local CAN controller to a higher-level communications system. Its differential transmit and receive paths support the physical CAN layer, while the compact 3 x 3 mm package leaves board space for processors, memory, and communication interfaces. The very low-current Standby mode is useful in installations with intermittent power budgets, and bus wake-up allows remote traffic to activate the node. Choose the exact ordering code only after confirming electrical ratings, qualification, and lifecycle requirements against the product operating environment and the manufacturer's ordering information.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ TJA1049TK/3J — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە |
|---|---|
| Package | 8-HVSON (3 x 3 mm) |
| Brand | NXP Semiconductors |
| Product Type | High-speed CAN transceiver with Standby mode |
| Supply Voltage Range | 3 V to 5 V |
| Bus Wake-Up | Supported |
| Transceiver Configuration | 1/1 transceiver |
| CAN Physical Layer | ISO 11898-2:2003, ISO 11898-5:2007, and pending updated ISO 11898-2:2016 |
| Mounting Type | Surface mount |
تێبینییەکانی دیزاین
Place the TJA1049TK/3J and its prescribed support components close to the CAN bus entry point, and follow the pin arrangement in the NXP manufacturer datasheet before assigning traces. Keep the CANH and CANL route away from sensitive analog and high-speed digital paths. The compact 8-HVSON footprint requires careful land-pattern and exposed-area handling, so use the manufacturer package drawing rather than inferring pad geometry from the 3 x 3 mm body size.
Operate the transceiver from the specified 3 V to 5 V range and decouple the supply exactly as directed in the NXP application circuit. The controller and transceiver should use a supply arrangement that keeps logic levels compatible and prevents supply transients from reaching the CAN interface. The documented Standby mode reduces current demand, but entering and leaving Standby must be coordinated with the CAN controller so bus traffic is not lost during the state transition.
Do not add a 120-ohm terminator at every CAN node. A two-wire CAN network normally uses termination only at the physical endpoints, with biasing arranged according to the network design. Also avoid treating TJA1049T/3 as a drop-in substitute for TJA1049TK/3J because their package designations differ. Confirm the exact 8-HVSON pinout, electrical limits, qualification, and ordering code before releasing a PCB or production build.
زانیاری پابەندبوون
The cited manufacturer product information and datasheet link do not provide explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals statements. The /J ordering code is not treated as proof of automotive qualification without an explicit NXP statement.