MAX128BCNG vs MAX128ACNG Comparison
Detailed side-by-side comparison of MAX128BCNG by Maxim Integrated and MAX128ACNG by Maxim Integrated. Compare key specifications, electrical parameters, packaging, lifecycle status, pricing, and availability to determine the best component for your design requirements.
Maxim Integrated
MAX128ACNG - 12-Bit 8-Channel +5V DAS, 24-PDIP | Maxim Integrated
MAX128ACNG ObsoleteSpecification Comparison
| Parameter | MAX128BCNG | MAX128ACNG |
|---|---|---|
| Brand | Maxim Integrated | Maxim Integrated |
| Category | ADC/DAC | ADC/DAC |
| Lifecycle Status | Active | Obsolete |
| Stock Status | In Stock | In Stock |
| Unit Price (USD) | $10.27 | $9.10 |
| Resolution | 12 bit | 12 bits |
| Number of Analog Input Channels | 8 | — |
| Sampling Rate | 8 ksps | 8 ksps |
| Supply Voltage | +5 V (single supply) | +5V single supply |
| Input Voltage Range | Software-selectable: 0 to VREF, 0 to VREF/2, ±VREF, ±VREF/2 | — |
| Internal Reference Voltage | 4.096 V | — |
| External Reference Support | Yes | — |
| Linearity (DNL/INL) | ±1/2 LSB | — |
| Track/Hold Bandwidth | 5 MHz | — |
| Fault-Protected Analog Inputs | ±16.5 V tolerant | — |
| Serial Interface | 2-wire I2C-compatible (SDA, SCL) | — |
| ADC Architecture | SAR (Successive Approximation) | SAR (Successive Approximation) with track/hold |
| Operating Temperature Range | 0C to +70C (C grade) | — |
| Package | 24-pin PDIP | 24-pin PDIP (N-24) |
| Mounting Type | Through-Hole | Through-Hole (DIP) |
| RoHS Status | Compliant (lead-free + suffix variants) | [DATA_NEEDED: RoHS status - MAX106 +] |
| Number of Input Channels | — | 8 single-ended / 4 differential |
| Input Range (Unipolar) | — | 0 to +5V, 0 to +10V, 0 to +15V |
| Input Range (Bipolar) | — | +/-5V, +/-10V, +/-15V |
| Supply Current (Operating) | — | [DATA_NEEDED: operating supply current] |
| Supply Current (Power-Down) | — | 1 uA (full power-down mode) |
| Internal Reference | — | 4.096 V |
| Data Interface | — | 2-wire I2C-compatible serial |
| INL (A-grade) | — | +/-1 LSB |
| Shutdown Modes | — | Hardware SHDN, software standby, software full power-down |
| Operating Temperature | — | [DATA_NEEDED: operating temperature range] |