XC7A200T-2FBG676I vs XC7A200T-2FB676I Comparison
Detailed side-by-side comparison of XC7A200T-2FBG676I by AMD and XC7A200T-2FB676I by Advanced Micro Devices, Inc.. Compare key specifications, electrical parameters, packaging, lifecycle status, pricing, and availability to determine the best component for your design requirements.
Advanced Micro Devices, Inc.
XC7A200T-2FB676I - 215K Artix-7 FPGA | Advanced Micro Devices
XC7A200T-2FB676I ✓ ActiveSpecification Comparison
| Parameter | XC7A200T-2FBG676I | XC7A200T-2FB676I |
|---|---|---|
| Brand | AMD | Advanced Micro Devices, Inc. |
| Category | FPGA & CPLD | FPGA & CPLD |
| Lifecycle Status | Active | Active |
| Unit Price (USD) | $100.00 | — |
| Family | Artix-7 | — |
| Number of LABs/CLBs | 16825 | — |
| Number of Logic Elements/Cells | 215360 | — |
| Total RAM Bits | 13455360 | — |
| Number of I/O | 400 | — |
| Package | 676-FCBGA (27x27) | 676-ball FCBGA |
| Operating Temperature | -40°C to 100°C (TJ) | — |
| Mounting Type | SMD (SMT) | — |
| Core Voltage | 1.0V | — |
| DSP Slices | 740 | 740 slices |
| Distributed RAM | 10.5 Mb | — |
| Transceivers | 16 (up to 6.6 Gb/s) | — |
| CMTs | 10 | — |
| Global Clock Buffers | 32 | — |
| Process Technology | 28nm HKMG | 28 nm |
| Lifecycle Status | Active | — |
| Device Type | — | Artix-7 Field Programmable Gate Array (FPGA) |
| Logic Cells | — | 215,360 cells |
| Adaptive Logic Modules | — | 33,650 ALMs |
| User I/O | — | 400 I/O |
| Embedded Memory | — | 12.83 Mbit |
| Core Supply Voltage | — | 1 V |
| Maximum Clock Frequency | — | 628 MHz |
| Speed Grade | — | -2 |
| Temperature Grade | — | Industrial |
| Clock Management | — | MMCM and PLL resources |
| Transceiver Support | — | Artix-7 family supports transceiver line rates |
| Analog Mixed-Signal Integration | — | Supported by the Artix-7 device family |
| RoHS Status | — | [DATA_NEEDED: RoHS status] |
| REACH Status | — | [DATA_NEEDED: REACH status] |
| AEC-Q100 Qualification | — | [DATA_NEEDED: AEC-Q100 qualification status] |
| Lead-Free Status | — | [DATA_NEEDED: lead-free status] |
| Operating Temperature Range | — | [DATA_NEEDED: minimum and maximum operating temperature] |