AD670JN vs AD670KP Vergleich
Detaillierter Direktvergleich von AD670JN von Analog Devices und AD670KP von Analog Devices. Vergleichen Sie die wichtigsten Spezifikationen, elektrischen Parameter, Gehäuse, Lebenszyklusstatus, Preise und Verfügbarkeit, um das beste Bauteil für Ihre Designanforderungen zu ermitteln.
Spezifikationsvergleich
| Parameter | AD670JN | AD670KP |
|---|---|---|
| Marke | Analog Devices | Analog Devices |
| Kategorie | ADC/DAC | ADC/DAC |
| Lebenszyklusstatus | Obsolete | Aktiv |
| Auflösung | 8 bit | 8 bit |
| Conversion Architecture | Successive approximation register (SAR) | — |
| Conversion Speed | 10 us | — |
| Number of Inputs | 2 | — |
| Input Type | Differential input | — |
| Integrated Front End | Instrumentation amplifier | Instrumentation amplifier |
| Integrated Conversion Elements | DAC, comparator, SAR, precision voltage reference, and tri-state output buffer | DAC, comparator, SAR, voltage reference, and three-state output buffer |
| Schnittstelle | Parallel microprocessor bus interface | — |
| Output Resolution Levels | 256 codes | — |
| External Trim Requirement | No user trims required | None required |
| External Interface Components | No external components required to interface | — |
| Gehäuse | 20-pin PDIP | 20-terminal PLCC |
| Montageart | Through-hole | Surface mount |
| Betriebstemperatur | 0C to 70C | 0°C to +70°C |
| Lebenszyklusstatus | Obsolete | — |
| Indicative Price | $61.00 as of 2026-10-30 | — |
| RoHS-Status | [DATA_NEEDED: RoHS status] | — |
| REACH Status | [DATA_NEEDED: REACH status] | — |
| Product Type | — | 8-bit signal-conditioning analog-to-digital converter |
| Architecture | — | Successive-approximation register (SAR) |
| Analog Input Channels | — | 2 channels |
| Conversion Time | — | 10 us |
| Linearity Error | — | 0.195% |
| Output Format | — | 8-bit parallel |
| Output Buffer | — | Three-state |
| Technology | — | Bipolar monolithic |
| Grade | — | K grade |
| RoHS Compliance | — | [DATA_NEEDED: RoHS compliance] |
| REACH Compliance | — | [DATA_NEEDED: REACH compliance] |
| AEC-Q100 Qualification | — | [DATA_NEEDED: AEC-Q100 qualification] |