BCM6123TD1E5126T00 vs BCM6123TD1E5126T01 Vergleich
Detaillierter Direktvergleich von BCM6123TD1E5126T00 von Vicor und BCM6123TD1E5126T01 von Vicor. Vergleichen Sie die wichtigsten Spezifikationen, elektrischen Parameter, Gehäuse, Lebenszyklusstatus, Preise und Verfügbarkeit, um das beste Bauteil für Ihre Designanforderungen zu ermitteln.
Vicor
BCM6123TD1E5126T00 - 380V/47.5V 25.7A Isolated BCM Bus Converter | Vicor
BCM6123TD1E5126T00 ✓ AktivSpezifikationsvergleich
| Parameter | BCM6123TD1E5126T00 | BCM6123TD1E5126T01 |
|---|---|---|
| Marke | Vicor | Vicor |
| Kategorie | DC-DC Converters | DC-DC Converters |
| Lebenszyklusstatus | Aktiv | Aktiv |
| Lagerstatus | In Stock | In Stock |
| Stückpreis (USD) | $122,10 | $130,25 |
| Topologie | Sine Amplitude Converter (SAC), fixed-ratio isolated | Sine Amplitude Converter (SAC), isolated fixed-ratio |
| Eingangsspannungsbereich | 260 V to 410 V (380 V nominal) | 260 V to 410 V |
| Output Voltage (Nominal) | 47.5 V (fixed K-factor ≈ 1:8 step-down) | — |
| Continuous Output Current | 25.7 A | 25.7 A |
| Peak Efficiency | 97.9 % | 97.9% |
| Power Density | 1876 W/in³ | 1876 W/in³ |
| Isolation Voltage | 4242 VDC | — |
| Throughput Power (approx.) | ~1220 W | — |
| Gehäuse | BCM6123 through-hole ChiP | Through-hole ChiP (BCM6123) |
| Montageart | Through Hole | — |
| Control Interface | Analog | — |
| Parallel Operation | Yes, for multi-kW arrays | Supported for multi-kW arrays |
| Protections | OV, OC, UV, short-circuit, thermal shutdown | OV, OC, UV, short circuit, thermal |
| Output Regulation | Unregulated (fixed K factor) | — |
| RoHS-Status | [DATA_NEEDED: RoHS status] | [DATA_NEEDED: RoHS status] |
| Betriebstemperatur | [DATA_NEEDED: operating temperature range] | -40°C to +125°C (see derating curves) |
| Transformation Ratio (K) | — | 1/8 (K=1/8) |
| Nominal Input Voltage | — | 380 V |
| Output Voltage (nominal) | — | 47.5 V |
| Continuous Output Power | — | 1220 W (47.5 V x 25.7 A) |
| Isolation Voltage (Input to Output) | — | 4242 VDC |
| Device Grade | — | T01 (telemetry/control) |
| Cooling Method | — | Forced air or cold-plate recommended for full load |