BTM9020EPXUMA1 vs TLE94110ESXUMA1 Vergleich
Detaillierter Direktvergleich von BTM9020EPXUMA1 von Infineon und TLE94110ESXUMA1 von Infineon. Vergleichen Sie die wichtigsten Spezifikationen, elektrischen Parameter, Gehäuse, Lebenszyklusstatus, Preise und Verfügbarkeit, um das beste Bauteil für Ihre Designanforderungen zu ermitteln.
Spezifikationsvergleich
| Parameter | BTM9020EPXUMA1 | TLE94110ESXUMA1 |
|---|---|---|
| Marke | Infineon | Infineon |
| Kategorie | Motor Drivers | Motor Drivers |
| Lebenszyklusstatus | Aktiv | Aktiv |
| Lagerstatus | In Stock | In Stock |
| Stückpreis (USD) | $1,82 | $2,45 |
| Topologie | Full-bridge (H-bridge) | — |
| Motor Type | Brushed DC (BDC) | — |
| Supply Voltage Range (Nominal) | 7 V to 18 V | — |
| Supply Voltage Range (Extended) | 4.5 V to 40 V | — |
| Typical Path Resistance | 84 mΩ at 25 °C | — |
| Current Limit (Minimum) | 20 A | — |
| Pulse Current (tpulse ≤ 1 s) | 8.8 A at 85 °C | — |
| Pulse Current (tpulse ≤ 10 s) | 6.9 A at 85 °C | — |
| PWM Frequency | 20 kHz | — |
| Gehäuse | PG-TSDSO-14 | PG-TSDSO-24 (24-pin, exposed thermal pad) |
| AEC-Q100 Qualification | Qualified | — |
| Betriebstemperatur | -40 °C to +150 °C (junction) | — |
| Logic Input Compatibility | 3.3 V / 5 V TTL | — |
| Protection Features | Overcurrent, Overtemperature, Undervoltage | — |
| Montageart | Surface Mount | Surface Mount |
| RoHS-Status | Compliant | Compliant |
| Charge Pump | Integrated | — |
| Family | MOTIX BTM9020EP / BTM9021EP | — |
| Product Type | — | Multi half-bridge DC motor driver |
| Number of Half-Bridges | — | 10 (configurable to 3, 4, 6, 8, 10, or 12 via output paralleling) |
| Supply Voltage Range | — | 5.5 V to 20 V |
| Maximum Output Current per Channel | — | 1.5 A (typical), 2 A peak (per RS listing) |
| Output Stage | — | Integrated N-channel DMOS half-bridges |
| Control Interface | — | 16-bit SPI (daisy-chain capable) or direct input (DI) |
| PWM Generation | — | Integrated, with adjustable dead time |
| Open-Load Detection | — | Yes, adjustable threshold on two outputs |
| Short-Circuit Protection | — | Yes |
| Overtemperature Protection | — | Yes (thermal shutdown) |
| Undervoltage Lockout | — | Yes |
| Betriebstemperaturbereich | — | -40 C to +150 C |
| Moisture Sensitivity Level | — | MSL 2A |