ISO124P vs ISO122P Vergleich
Detaillierter Direktvergleich von ISO124P von Texas Instruments und ISO122P von Texas Instruments. Vergleichen Sie die wichtigsten Spezifikationen, elektrischen Parameter, Gehäuse, Lebenszyklusstatus, Preise und Verfügbarkeit, um das beste Bauteil für Ihre Designanforderungen zu ermitteln.
Texas Instruments
ISO124P - 8-Pin DIP Isolation Amplifier, 1.5kV | Texas Instruments
ISO124P ✓ AktivSpezifikationsvergleich
| Parameter | ISO124P | ISO122P |
|---|---|---|
| Marke | Texas Instruments | Texas Instruments |
| Kategorie | Amplifier ICs | Amplifier ICs |
| Lebenszyklusstatus | Aktiv | Aktiv |
| Isolation Voltage (Rated) | 1500 Vrms | — |
| Isolation Barrier Type | Capacitive (matched 1 pF differential) | — |
| Modulation Technique | Duty-cycle modulation/demodulation | — |
| Number of Channels | 1 | — |
| Eingangsspannungsbereich | ±10 V (bipolar) | — |
| Supply Voltage Range (each side) | ±4.5 V to ±18 V | — |
| Quiescent Current (V_S1) | ±5 mA | — |
| Quiescent Current (V_S2) | ±5.5 mA | — |
| Bandwidth (Small Signal) | 50 kHz | — |
| Nonlinearity (Max) | 0.010% max | — |
| Input Offset Voltage Drift | 200 uV/°C max | — |
| Common-Mode Rejection (CMR) | 140 dB typical | — |
| Gain Configuration | Fixed unity gain (1 V/V) | Fixed unity gain |
| Gehäuse | 8-pin PDIP (P) | — |
| Montageart | Through-hole | Through-hole |
| Betriebstemperatur | -25°C to +85°C | — |
| RoHS-Status | Compliant (lead-free finish) | — |
| Product Type | — | Precision isolation amplifier |
| Number of Circuits | — | 1 circuit |
| Maximum Nonlinearity | — | 0.020% |
| Signal Bandwidth | — | 50 kHz |
| Input Offset-Voltage Drift | — | 200 V/°C maximum |
| Power Supply Range | — | 4.5 V to 18 V |
| VS1 Quiescent Current | — | 5 mA |
| VS2 Quiescent Current | — | ±5.5 mA |
| Bipolar Supply Operation | — | ±10 V |
| High-Voltage Breakdown Rating | — | 1500 Vrms |
| Isolation Method | — | Duty-cycle modulation and demodulation |
| Differential Capacitive Barrier | — | 2 pF |
| ISO122P Package | — | 8-pin plastic DIP |
| Single-Supply Operation | — | Supported on the high-voltage side with a 5.1 V Zener-generated negative supply |
| High-Voltage Testing | — | 100% tested for rated high-voltage breakdown |