MAX303CSE+ vs MAX303ESE+ Vergleich
Detaillierter Direktvergleich von MAX303CSE+ von Analog Devices und MAX303ESE+ von Maxim Integrated. Vergleichen Sie die wichtigsten Spezifikationen, elektrischen Parameter, Gehäuse, Lebenszyklusstatus, Preise und Verfügbarkeit, um das beste Bauteil für Ihre Designanforderungen zu ermitteln.
Maxim Integrated
MAX303ESE+ - Dual Precision SPDT Analog Switch | Maxim Integrated
MAX303ESE+ ✓ AktivSpezifikationsvergleich
| Parameter | MAX303CSE+ | MAX303ESE+ |
|---|---|---|
| Marke | Analog Devices | Maxim Integrated |
| Kategorie | Interface ICs | Interface ICs |
| Lebenszyklusstatus | Aktiv | Aktiv |
| Product Type | Precision dual high-speed SPDT analog switch | Precision analog switch |
| Number of Channels | 2 channels | 2 |
| Switch Configuration | 2:1 SPDT per channel | — |
| Maximum On Resistance | 35Ω | — |
| On-Resistance Matching | 2Ω maximum between channels | — |
| Leakage Current | Less than 250pA at 25°C | — |
| Leakage Current at 85°C | Less than 6nA | — |
| Charge Injection | 15pC | — |
| Power Consumption | 35μW | [DATA_NEEDED: power consumption] |
| Maximum Breakdown Voltage | 44V | — |
| Positive Supply Voltage Range | 10V to 30V | — |
| Negative Supply Voltage Range | -4.5V to -20V | — |
| Gehäuse | 16-pin NSOIC | 16-pin narrow SOIC |
| Pin-Anzahl | 16 pins | — |
| Montageart | Surface mount | Surface mount |
| Lebenszyklusstatus | Production | — |
| RoHS-Status | unknown | Unknown |
| REACH Status | unknown | Unknown |
| Switch Type | — | 2 x SPDT |
| On Resistance | — | 35 ohm maximum |
| Channel Resistance Matching | — | Within 2 ohm |
| Supply Voltage Range, Single | — | 10 V to 30 V |
| Supply Voltage Range, Dual | — | +/-4.5 V to +/-20 V |
| Leakage Current at 25C | — | Less than 250 pA |
| Leakage Current at 85C | — | Less than 6 nA |
| Turn-On Time | — | Less than 150 ns |
| Turn-Off Time | — | Less than 100 ns |
| Control Interface | — | Digital control |
| Switching Configuration | — | Single-pole, double-throw |
| Betriebstemperaturbereich | — | [DATA_NEEDED: operating temperature range] |
| Versorgungsstrom | — | [DATA_NEEDED: supply current] |
| Body Dimensions | — | [DATA_NEEDED: body dimensions] |