MMA5124KW vs MMA5224KW Vergleich
Detaillierter Direktvergleich von MMA5124KW von NXP Semiconductors und MMA5224KW von NXP Semiconductors. Vergleichen Sie die wichtigsten Spezifikationen, elektrischen Parameter, Gehäuse, Lebenszyklusstatus, Preise und Verfügbarkeit, um das beste Bauteil für Ihre Designanforderungen zu ermitteln.
Spezifikationsvergleich
| Parameter | MMA5124KW | MMA5224KW |
|---|---|---|
| Marke | NXP Semiconductors | NXP Semiconductors |
| Kategorie | Motion Sensors | Motion Sensors |
| Lebenszyklusstatus | Aktiv | Aktiv |
| Lagerstatus | In Stock | In Stock |
| Stückpreis (USD) | $9,75 | $8,05 |
| Sensortyp | Accelerometer, Z-Axis | Accelerometer (single-axis X) |
| Messbereich | ±240 g | — |
| Axis | Z (single-axis, overdamped) | — |
| Versorgungsspannung | 4.2 V to 17 V | — |
| Schnittstelle | PSI5 v1.3 (two-wire current loop) | — |
| Protocol Compatibility | AKLV27, PSI5 Version 1.3 | PSI5 Version 1.3 / AKLV27 |
| Ausgangstyp | Digital (PSI5 Manchester-coded) | — |
| Gehäuse | 16-QFN (6x6 mm) with exposed pad | 16-QFN (HQCCN, 6x6 mm) |
| Montageart | Surface Mount | Surface Mount (SMT) |
| Betriebstemperatur | -40°C to +125°C (automotive) | — |
| MEMS Type | Overdamped, sealed cavity | — |
| On-chip Memory | EEPROM for calibration | — |
| Functional Safety | SafeAssure solution | — |
| RoHS-Status | Compliant | — |
| Pin-Anzahl | 16 | — |
| Data Transmission | 10-bit Manchester-coded PSI5 | — |
| Family | — | Xtrinsic MMA52xxKW (PSI5 / AKLV27 satellite) |
| Axis of Measurement | — | X (single axis, lateral) |
| Full-Scale Acceleration Range | — | ±240 g |
| Mechanical Damping | — | Overdamped (deliberate per datasheet) |
| Data Coding | — | Manchester coded, 10-bit data length |
| Bit Rate | — | 125 kbps or 250 kbps selectable |
| Programmable Addresses | — | 16 PSI5 addresses |
| Communication Type | — | Bidirectional, synchronous |
| Supply Voltage (VDD) | — | 5 V (regulated) |
| Automotive Qualification | — | AEC-Q100 (per device family) |
| EU RoHS Status | — | RoHS Compliant (Lead Free) |
| Operating Mode | — | Satellite node, two-wire current loop to ECU |