MMA5212AKW vs MMA5212KWR2 Vergleich
Detaillierter Direktvergleich von MMA5212AKW von NXP Semiconductors und MMA5212KWR2 von NXP Semiconductors. Vergleichen Sie die wichtigsten Spezifikationen, elektrischen Parameter, Gehäuse, Lebenszyklusstatus, Preise und Verfügbarkeit, um das beste Bauteil für Ihre Designanforderungen zu ermitteln.
NXP Semiconductors
MMA5212KWR2 - 120g X-Axis PSI5 Inertial Sensor | NXP Semiconductors
MMA5212KWR2 ObsoleteSpezifikationsvergleich
| Parameter | MMA5212AKW | MMA5212KWR2 |
|---|---|---|
| Marke | NXP Semiconductors | NXP Semiconductors |
| Kategorie | Motion Sensors | Motion Sensors |
| Lebenszyklusstatus | Aktiv | Obsolete |
| Lagerstatus | In Stock | In Stock |
| Stückpreis (USD) | $9,40 | $7,10 |
| Type | Accelerometer, single axis (X) | — |
| Full-Scale Range | ±120 g | — |
| Axis | X (single axis) | X (lateral) |
| Output Interface | PSI5 V1.3 asynchronous mode | — |
| Data Resolution | 16-bit | — |
| Supply Voltage Range | 4.2 V to 17 V | — |
| Mechanical Transducer | Overdamped X-axis MEMS | — |
| Betriebstemperaturbereich | -40 °C to +125 °C | — |
| Gehäuse | 16-QFN (HQCCN), 6 x 6 mm | 16-pin QFN EP (6 × 6 mm) with exposed pad |
| Montageart | Surface Mount | Surface Mount |
| Terminal Count | 16 | — |
| Package Code | HQCCN | — |
| Automotive Grade | AEC-Q100 qualified (SafeAssure) | — |
| Communication Protocol | PSI5 V1.3 (Manchester coded, two-wire current loop) | — |
| Family | Xtrinsic MMA52xxAKW | — |
| Sensortyp | — | Accelerometer (single-axis, X-axis, overdamped) |
| Messbereich | — | ±120 g |
| Ausgangstyp | — | PSI5 digital (Manchester / Half-Bit encoded) |
| Versorgungsspannung | — | 5 V / 9 V / 12 V / 15 V (PSI5 standard) |
| Interface Protocol | — | PSI5 Version 1.3 and AKLV27 |
| Betriebstemperatur | — | -40 °C to +125 °C |
| Self-Test | — | Integrated (electrostatic self-test) |
| Programmability | — | Internal EEPROM for calibration coefficients |
| Automotive Qualification | — | AEC-Q100 (Freescale/NXP SafeAssure family) |
| Mechanical Response | — | Overdamped (suitable for crash pulse capture) |
| RoHS-Status | — | Compliant |
| Lead-Free Status | — | Lead Free (per digchip listing) |
| Halogenfrei | — | Compliant (per GlobalSpec listing) |