Parameter MPXV2010GP MPXV2202GP
Marke STMicroelectronics NXP Semiconductors
Kategorie Pressure Sensors Pressure Sensors
Lebenszyklusstatus Aktiv Aktiv
Lagerstatus In Stock In Stock
Stückpreis (USD) $8,62 $5,50
Pressure Type Vented Gauge Vented Gauge
Operating Pressure Range 0 kPa to 10 kPa 0 kPa to 200 kPa (0 psi to 29.01 psi)
Maximum Overload Pressure 75 kPa —
Supply Voltage (Vex) 10 V typical (max 16 V) —
Full-Scale Output (Span) at 10 V 25 mV nominal at 10 kPa —
Zero Pressure Output (Offset) 0 mV to 1.0 mV —
Pressure Hysteresis 1.0 kPa (typical) —
Sensitivity 2.5 mV/kPa nominal at 10 V 0.2 mV/V nominal
Response Time 1.0 ms (typical) —
Ausgangstyp Analog, ratiometric, mV output Analog voltage (ratiometric, differential bridge)
Betriebstemperatur -40 C to +125 C —
Port Configuration Single vertical side port, 0.13" (3.17 mm) tube —
Gehäuse 8-SMD, Gull Wing, Side Port (Case 344B-01) 8-SMD, Gull Wing, Side Port (SO8 / SOP-8 with vertical port)
Montageart Surface Mount Surface Mount
Technology Silicon piezoresistive MEMS, on-chip temp compensated —
RoHS-Status Compliant unknown
Manufacturer — NXP Semiconductors
Product Type — Piezoresistive Pressure Sensor
Versorgungsspannung — 10 V typical
Full-Scale Output — 0 mV to 40 mV at 10 V supply
Temperature Compensation — On-chip, 0 C to 85 C
Calibration — On-chip, laser trimmed
Body Dimensions — 12.06 mm x 12.06 mm x 8.38 mm
Lead Pitch — 2.54 mm
Port Style — Side-mounted vertical port, 0.13 inch (3.17 mm) tube
Min Operating Temperature — [DATA_NEEDED: min operating temperature]
Max Operating Temperature — [DATA_NEEDED: max operating temperature]

Datenblätter & Ressourcen