MPXV4115VC6U vs MPXV53GC7U Vergleich
Detaillierter Direktvergleich von MPXV4115VC6U von STMicroelectronics und MPXV53GC7U von NXP Semiconductors. Vergleichen Sie die wichtigsten Spezifikationen, elektrischen Parameter, Gehäuse, Lebenszyklusstatus, Preise und Verfügbarkeit, um das beste Bauteil für Ihre Designanforderungen zu ermitteln.
STMicroelectronics
MPXV4115VC6U - -115kPa Vacuum Pressure Sensor, 0.2-4.6V | STMicroelectronics
MPXV4115VC6U ✓ AktivNXP Semiconductors
MPXV53GC7U - 50 kPa Uncompensated Vented Gauge Pressure Sensor | NXP
MPXV53GC7U ✓ AktivSpezifikationsvergleich
| Parameter | MPXV4115VC6U | MPXV53GC7U |
|---|---|---|
| Marke | STMicroelectronics | NXP Semiconductors |
| Kategorie | Pressure Sensors | Pressure Sensors |
| Lebenszyklusstatus | Aktiv | Aktiv |
| Lagerstatus | In Stock | In Stock |
| Stückpreis (USD) | $9,95 | $7,20 |
| Pressure Type | Vacuum (negative gauge) | — |
| Pressure Range | 0 to -115 kPa (-16.68 PSI) | — |
| Operating Pressure Minimum | [DATA_NEEDED: kPa lower bound verification] | — |
| Ausgangstyp | Analog voltage, ratiometric | Analog Voltage (Wheatstone bridge) |
| Ausgangsspannung | 0.2 V to 4.6 V | 0 mV to 60 mV at 3 V excitation |
| Versorgungsspannung | 4.85 V to 5.35 V (5 V nominal) | — |
| Versorgungsstrom | [DATA_NEEDED: typical mA] | — |
| Accuracy | [DATA_NEEDED: max pressure error %] | — |
| Response Time | 10 ms | — |
| Betriebstemperatur | -40 C to +125 C | -40 °C to +125 °C |
| Compensated Temperature | 0 C to +85 C | — |
| Port Style | Top port, 0.13 inch (3.17 mm) tube | — |
| Port Size | 3.17 mm (1/8 inch) | — |
| Gehäuse | 8-SMD, Gull Wing, Top Port (SOP-8) | — |
| Montageart | Surface Mount | Through Hole |
| MSL-Level | [DATA_NEEDED: MSL rating] | [DATA_NEEDED: MSL rating] |
| Sensor Technology | Piezoresistive (silicon Wheatstone bridge) | — |
| RoHS-Status | Compliant | Compliant |
| Sensortyp | — | Pressure Sensor, Vented Gauge |
| Operating Pressure Range | — | 0 kPa to 50 kPa (0 PSI to 7.25 PSI) |
| Pressure Port Type | — | Male - 0.13" (3.17 mm) Tube, Top Port |
| Reference Type | — | Vented Gauge |
| Sensitivity (typ) | — | 1.0 mV/kPa at 3 V excitation |
| Excitation Voltage | — | 3 V typical (up to 10 V max per datasheet) |
| Input Impedance | — | 1.0 kΩ to 3.0 kΩ |
| Output Impedance | — | 1.0 kΩ to 3.0 kΩ |
| Gehäuse / Bauform | — | 8-DIP (0.550", 13.97 mm) through-hole, top port |
| Compensation | — | Uncompensated (raw bridge output) |