TLE75602ESHXUMA1 vs TLE94110ESXUMA1 Vergleich
Detaillierter Direktvergleich von TLE75602ESHXUMA1 von Infineon und TLE94110ESXUMA1 von Infineon. Vergleichen Sie die wichtigsten Spezifikationen, elektrischen Parameter, Gehäuse, Lebenszyklusstatus, Preise und Verfügbarkeit, um das beste Bauteil für Ihre Designanforderungen zu ermitteln.
Spezifikationsvergleich
| Parameter | TLE75602ESHXUMA1 | TLE94110ESXUMA1 |
|---|---|---|
| Marke | Infineon | Infineon |
| Kategorie | Power MOSFET Drivers | Motor Drivers |
| Lebenszyklusstatus | Aktiv | Aktiv |
| Lagerstatus | In Stock | In Stock |
| Stückpreis (USD) | $2,95 | $2,45 |
| Product Type | 8-channel SPI power switch (low-side / high-side) | Multi half-bridge DC motor driver |
| Number of Channels | 8 | — |
| Per-channel Output Current | 330 mA | — |
| Switch Configuration | 1:8 N-Channel | — |
| Operating Voltage Range | 4.5 V to 28 V (supports 3.0 V cranking) | — |
| Schnittstelle | 16-bit SPI | — |
| PWM Generation | Configurable per channel, on-chip | Integrated, with adjustable dead time |
| Rds(on) per channel | [DATA_NEEDED: typical Rds(on) per channel] | — |
| Gehäuse | PG-TSDSO-24-21 (exposed pad) | PG-TSDSO-24 (24-pin, exposed thermal pad) |
| Montageart | Surface Mount | Surface Mount |
| Betriebstemperatur | -40 C to +150 C (junction, AEC-Q100 automotive grade) | — |
| AEC-Q100 Qualified | Yes | — |
| Diagnostic Features | Open-load detect, short-to-battery, short-to-ground, overtemperature, current sense | — |
| Reverse Battery Protection | Via external resistor | — |
| Load Dump Protection | Yes | — |
| RoHS-Status | Compliant | Compliant |
| Number of Half-Bridges | — | 10 (configurable to 3, 4, 6, 8, 10, or 12 via output paralleling) |
| Supply Voltage Range | — | 5.5 V to 20 V |
| Maximum Output Current per Channel | — | 1.5 A (typical), 2 A peak (per RS listing) |
| Output Stage | — | Integrated N-channel DMOS half-bridges |
| Control Interface | — | 16-bit SPI (daisy-chain capable) or direct input (DI) |
| Open-Load Detection | — | Yes, adjustable threshold on two outputs |
| Short-Circuit Protection | — | Yes |
| Overtemperature Protection | — | Yes (thermal shutdown) |
| Undervoltage Lockout | — | Yes |
| Betriebstemperaturbereich | — | -40 C to +150 C |
| Moisture Sensitivity Level | — | MSL 2A |