XRD87L75AIP-F vs MAX187CEWE Vergleich
Detaillierter Direktvergleich von XRD87L75AIP-F von MaxLinear und MAX187CEWE von Maxim Integrated. Vergleichen Sie die wichtigsten Spezifikationen, elektrischen Parameter, Gehäuse, Lebenszyklusstatus, Preise und Verfügbarkeit, um das beste Bauteil für Ihre Designanforderungen zu ermitteln.
Maxim Integrated
MAX187CEWE - 12-Bit 75kSPS Serial ADC, 16-SOIC | Maxim Integrated
MAX187CEWE ✓ AktivSpezifikationsvergleich
| Parameter | XRD87L75AIP-F | MAX187CEWE |
|---|---|---|
| Marke | MaxLinear | Maxim Integrated |
| Kategorie | ADC/DAC | ADC/DAC |
| Lebenszyklusstatus | Obsolete | Aktiv |
| Lagerstatus | In Stock | In Stock |
| Stückpreis (USD) | $4,15 | $10,55 |
| Auflösung | 8 bit | 12 bits |
| Abtastrate | 10 MSPS | — |
| Number of Channels | 1 | — |
| Architecture | 2-step Flash | SAR (Successive Approximation) |
| Versorgungsspannung | 3.3 V (single) | +4.75 V to +5.25 V (single +5 V supply) |
| Analog Input Range | 0 V to VDD | 0 V to +5 V |
| Reference Input Range | 1 V to VDD | — |
| Power Dissipation | 25 mW typical (excluding reference) | — |
| Sample-and-Hold | Internal | — |
| Digital Interface | Parallel | SPI / QSPI / MICROWIRE-compatible serial |
| Latch-Up | Latch-up free CMOS | — |
| Gehäuse | 20-pin PDIP | 16-pin wide-body SOIC ("WE") |
| Montageart | Through-Hole | Surface Mount |
| RoHS-Status | Compliant (Pb-free variant -F) | Non-compliant (legacy "CEWE" suffix, pre-2011 lead-finish; + suffix variants are RoHS-compliant) |
| Betriebstemperatur | [DATA_NEEDED: operating temperature range] | — |
| Sampling Rate (max) | — | 75 kSPS |
| Number of Inputs | — | 1 (single-ended) |
| Operating Supply Current | — | 1.5 mA (typ, during conversion) |
| Abschaltstrom | — | 10 µA |
| Conversion Time | — | 8.5 µs |
| Track/Hold Acquisition | — | 1.5 µs |
| Integral Nonlinearity (max) | — | ±1 LSB |
| Reference | — | Internal 4.096 V buffered (MAX187); external required for MAX189 |
| Betriebstemperaturbereich | — | -40 °C to +85 °C (C grade) |
| MSL-Level | — | 1 (unlimited floor life at <30 °C / 85% RH, per JEDEC J-STD-020) |