AD7711AN - 24-Bit Sigma-Delta ADC | Analog Devices
Teilenummer: AD7711AN ✓ AktivAD7711AN Übersicht
A sigma-delta analog-to-digital converter is an ADC category that uses oversampling and digital filtering to deliver high resolution from low-frequency or slowly changing signals. Its architecture belongs to the broader ADC -> data converter -> signal-chain IC hierarchy. This is especially useful in sensor instrumentation because the input signal can change slowly while the converter emphasizes resolution, noise rejection, and stable measurement rather than high-speed transient capture.
The AD7711 family supports one differential analog input and one single-ended analog input. One channel can serve as the primary measurement input while the other periodically measures a second voltage. Its matched RTD excitation currents support resistance-based temperature sensors, while the differential reference architecture establishes the voltage basis for conversion. The AD7711AN is specified as a production CMOS device and is offered in a through-hole 24-pin PDIP package for conventional PCB assembly.
The converter resolves up to 24 bits without missing codes in the AD7711 family description, making it appropriate for process monitoring, temperature instrumentation, and laboratory measurements with low-level transducer outputs. Digital filtering and calibration can be configured through the serial interface, allowing the system to balance conversion speed, rejection of noise, and usable measurement resolution. Because the serial interface also controls operating modes, implementation requires a reliable clock, carefully defined data timing, and software that accounts for settling after input or reference changes.
Typical uses include RTD temperature measurement, low-level pressure and strain-signal conditioning, industrial process monitoring, precision laboratory instrumentation, and auxiliary-channel measurement systems. The two-input arrangement is valuable when a second voltage must be checked periodically without duplicating the complete converter. A differential reference can also support systems where reference error would otherwise degrade measurement accuracy.
The principal design consideration is that a sigma-delta ADC trades conversion latency for noise performance and resolution. Allow the digital filter to settle before reading a result, keep the analog input and reference layout compact, and decouple supply and reference nodes close to the device. External protection, filtering, and excitation circuitry should be selected from the complete transducer and measurement requirements rather than from resolution alone.
This page organizes the verified AD7711AN device identity, package information, sourcing routes, application guidance, and same-package replacement options. It also distinguishes the exact AD7711AN from temperature-grade and lead-finish variants, helping engineers confirm ordering, PCB, and lifecycle requirements before committing to a design.
Drop-in-Alternativen für AD7711AN – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
AD7711ANZ
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
AD7711ANI
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
AD7711AN Grenzwerte & elektrische Eigenschaften
| Auflösung | 24 bit |
| Converter Architecture | 1 sigma-delta converter |
| Analog Input Count | 2 inputs |
| Differential Analog Input | 1 input |
| Single-Ended Analog Input | 1 input |
| Differential Reference Input | 1 input |
| RTD Excitation Current | Matched excitation currents |
| Output Format | Serial digital word |
| Process Technology | Production CMOS |
| Gehäuse | 24-pin PDIP |
| Montageart | Through-hole |
AD7711AN 24-pin pdip Pinbelegungsleitfaden
Pinbelegung für AD7711AN (24-pin pdip-Gehäuse). Dieses analoge Bauteil verfügt über Eingangs-, Ausgangs- und Versorgungspins. Offset-Null-, Kompensations- und Enable-Pin-Konfigurationen entnehmen Sie dem Herstellerdatenblatt. Ideal für Signalaufbereitung und Verstärkerschaltungen.
Keine detaillierten Pinbelegungsdaten verfügbar für AD7711AN.
Siehe die Datenblatt für die vollständige Pin-Konfiguration.
Typische Anwendungen
AD7711AN ist geeignet für 6 Anwendungs: RTD Temperature Measurement, Precision Industrial Process Monitoring, Low-Level Bridge Sensor Interface, Laboratory Precision Instrumentation, Auxiliary Voltage Monitoring, Environmental Sensor Acquisition.
RTD Temperature Measurement
The AD7711AN is a natural fit for resistance-based temperature sensors because the AD7711 family provides matched RTD excitation currents and a differential analog measurement input. The 24-bit sigma-delta conversion path is intended for slow sensor signals, allowing the measurement system to emphasize resolution rather than high-frequency conversion speed. In the circuit, the RTD forms a bridge with precision resistors, and the bridge differential output feeds the converter input. The excitation current and reference error directly influence measurement accuracy, so component tolerances, self-heating, lead resistance, and differential layout must be evaluated together.
Empfohlen
Precision Industrial Process Monitoring
The AD7711AN supports low-level industrial process measurements where sensor output changes relatively slowly and high-resolution digital data is more useful than rapid acquisition. Its 24-bit sigma-delta architecture, two analog inputs, and differential reference input allow one channel to perform the primary measurement while the second periodically checks an auxiliary voltage. This arrangement can detect supply, reference, or sensor-node drift without duplicating the converter. The design should include differential input routing, protection appropriate to the transducer, and a digital-filter settling strategy that preserves resolution while meeting the control-loop update interval.
Empfohlen
Low-Level Bridge Sensor Interface
The differential analog input of the AD7711AN is suited to bridge-based sensors that generate small differential voltages around a common-mode level. With a 24-bit conversion resolution and sigma-delta filtering, the device can digitize slowly changing force, pressure, or position signals without requiring a high-speed flash ADC. Place the bridge excitation, reference network, input filtering, and converter in a compact analog section to minimize sensitivity to noise and ground gradients. Because bridge mismatch and sensor self-heating can dominate the final accuracy, the converter resolution alone should not be treated as the complete measurement accuracy.
Empfohlen
Laboratory Precision Instrumentation
The AD7711AN fits laboratory instruments that digitize low-level sensor outputs and require a serial data interface rather than a high-throughput parallel bus. The 24-bit sigma-delta architecture favors high resolution for stable laboratory signals, while the dual-input arrangement can support a primary measurement and a periodically sampled auxiliary channel. Use the differential reference input to establish a controlled measurement basis and route both analog inputs away from digital clocks and switching nodes. Firmware should configure the digital filter, wait for settling after channel or reference changes, and retain calibration coefficients for a traceable measurement chain.
Empfohlen
Auxiliary Voltage Monitoring
The two analog inputs allow the AD7711AN to perform more than a single-channel measurement. A practical configuration uses the differential input for the primary signal and the single-ended input to inspect a second voltage, such as a supply-derived diagnostic or sensor bias. This can reduce board area by sharing one 24-bit sigma-delta converter between two related measurements. The tradeoff is shared conversion time and filter settling: the firmware must sequence the channels and avoid treating an auxiliary reading taken during a transition as a settled result. Reference stability also affects both channels, making the reference layout a priority.
Empfohlen
Environmental Sensor Acquisition
The AD7711AN can acquire low-frequency outputs from environmental sensors when the system prioritizes resolution, simple transducer interfacing, and compact digital output. The 24-bit sigma-delta converter is appropriate for signals that evolve slowly, such as temperature, humidity-derived analog outputs, or gas-sensor resistance interfaces. Matched RTD excitation currents can be useful when the selected sensor is resistive, while the second input can check a bias or diagnostic voltage. Because environmental enclosures can introduce slow drift and EMI, keep the analog loop compact, provide suitable input protection, and schedule measurements so digital-filter settling does not compromise the required update period.
Empfohlen
Technische Referenzdaten für AD7711AN – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | AD7711ANZ | AD7711ANI |
|---|---|---|---|
| Package | 24-pin PDIP | 24-pin PDIP | 24-pin PDIP |
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Converter Resolution | 24 bit | 24 bit | 24 bit |
| Conversion Architecture | Sigma-delta | Sigma-delta | Sigma-delta |
| Analog Input Count | 2 inputs | 2 inputs | 2 inputs |
| RTD Excitation Current | Matched excitation currents | Matched excitation currents | Matched excitation currents |
| Ordering Difference | AN lead-finish and temperature-grade designation | Z lead-finish designation; 0% resolution difference | I temperature-grade designation; 0% resolution difference |
Wichtigste Unterscheidungsmerkmale
- Same-package selection with unchanged conversion resolution (vs. AD7711ANZ)
- Temperature-grade option without changing the PCB footprint (vs. AD7711ANI)
- Purpose-built low-level transducer conditioning (vs. AD7714AN-3)
Designhinweise
Route the differential analog input as a compact, matched pair and place its input filtering close to the AD7711AN. Keep the RTD excitation, bridge, reference, and converter in the same analog region. Digital clock and serial-interface traces should not run beneath or parallel to the sensitive input path. Use a ground strategy that gives the differential input and reference return paths a low-noise path to the device.
Decouple the supply pins close to the IC with the capacitance and voltage rating specified by the Analog Devices manufacturer data sheet. Provide separate, low-impedance paths for the analog and digital returns when the board structure permits. Confirm startup sequencing, supply noise, and reference settling before interpreting the first conversion result; adequate supply bypassing does not by itself guarantee valid data if the reference is not settled.
Configure the digital filter for the required update rate and allow sufficient settling time after changing the input channel, filter setting, or reference state. A 24-bit conversion resolution should not be treated as 24 useful bits unless noise, reference error, excitation accuracy, and calibration allow it. In firmware, distinguish conversion latency from data-valid latency and avoid averaging results that were sampled before the input signal stabilized.
Do not substitute AD7711ANZ or AD7711ANI solely because their packages match. The Z suffix changes the lead-finish designation, while the I suffix changes the temperature-grade designation. Confirm both the environmental limits and assembly requirements against the exact ordering code. Also avoid treating the AD7711AN as a general-purpose high-speed ADC; its sigma-delta architecture is optimized for low-frequency measurement and requires filter-aware timing.
Compliance-Informationen
The available product information identifies AD7711AN as a production CMOS device in a 24-pin PDIP package but does not state the requested compliance statuses.