Teilenummer: AD7875KP ✓ AktivAD7875KP Übersicht
A sampling ADC is a data-conversion device that samples an analog voltage at a controlled instant and converts it into a digital code. Successive-approximation, or SAR, ADCs repeatedly compare the sampled input with internally generated reference voltages to determine each output bit. The AD7875 belongs to the ADC hierarchy, then data-converter and signal-chain IC categories, providing a direct interface between analog sensors or conditioned signals and digital processing systems.
The principal specifications are 12-bit resolution, a 100 kHz sampling rate, one analog input channel, a 5 V unipolar input range, and a 28-pin PLCC package. These characteristics make the converter suitable for industrial monitoring, process control, instrumentation, and embedded measurement systems. A 100 kHz conversion rate allows the converter to capture rapidly changing analog conditions while requiring only 12 bits for many position, level, and sensor measurements.
The LC²MOS implementation supports low-power mixed-signal operation and integrates the converter's reference and control functions. Because the device is a sampling rather than continuous-resolution ADC, the conversion system must account for acquisition time, input settling, sampling instant, and the transfer interval to the digital host. System timing should preserve the relationship between the physical input signal and the corresponding conversion result.
Typical applications include pressure and temperature monitoring, process-control instrumentation, digital panel meters, industrial transducers, and data-acquisition modules. In these systems, an analog front end usually scales and filters the sensor output before the AD7875KP converts it. Digital logic can then read the result through a suitable bus interface and use it for display, alarm, control, or data logging.
The primary design consideration is analog signal integrity around the input. The input source must settle within the converter's acquisition interval, while reference and supply decoupling should be routed according to the manufacturer's application guidance. PCB layout, grounding, and the choice between single-ended and differential conversion paths can materially affect achievable resolution.
This product page combines the manufacturer's core specifications with package identification, application guidance, design cautions, and verified replacement information. It is intended to help engineers select the correct ADC and plan the surrounding analog, digital, layout, and signal-conditioning work before committing a board design to production.
Drop-in-Alternativen für AD7875KP – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
Varianten dieser Serie
Modelle derselben Serie, die drop-in-kompatibel sind mit AD7875KP (gleiche Bauform und Footprint) – abweichend in Package, Sampling Rate, Architecture, Digital Interface, Input Voltage Range.
AD7875LPZ-REEL
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →AD7875KP Grenzwerte & elektrische Eigenschaften
| Auflösung | 12 bit |
| Abtastrate | 100 kHz |
| Architecture | Successive-approximation (SAR) |
| Input Channel Count | 1 channel |
| Analog Input Range | Unipolar 5 V |
| Gehäuse | 28-pin PLCC, 11.51 mm x 11.51 mm |
| Montageart | Surface mount |
| Process Technology | CMOS LC2MOS |
| Temperature Grade | Commercial |
| Production Status | Production CMOS |
AD7875KP 28-pin plcc, 11.51 mm x 11.51 mm Pinbelegungsleitfaden
Pinbelegung für AD7875KP (28-pin plcc, 11.51 mm x 11.51 mm-Gehäuse). Dieses analoge Bauteil verfügt über Eingangs-, Ausgangs- und Versorgungspins. Offset-Null-, Kompensations- und Enable-Pin-Konfigurationen entnehmen Sie dem Herstellerdatenblatt. Ideal für Signalaufbereitung und Verstärkerschaltungen.
Keine detaillierten Pinbelegungsdaten verfügbar für AD7875KP.
Siehe die Datenblatt für die vollständige Pin-Konfiguration.
Typische Anwendungen
AD7875KP ist geeignet für 6 Anwendungs: Industrial Pressure Measurement, Temperature and Thermocouple Monitoring, Process Control Instrumentation, Digital Panel Meter, Position and Motor Feedback, Data Acquisition Module.
Industrial Pressure Measurement
The AD7875KP suits pressure-transducer monitoring when a conditioner produces a unipolar analog signal within the converter's 5 V range. Its 12-bit resolution divides that range into 4,096 quantization levels, while the 100 kHz sampling rate allows the controller to follow pressure changes and reject short disturbances. A bridge or transducer amplifier can drive the input through an anti-alias filter, with the converter generating a digital measurement for display, alarm evaluation, or process feedback.
Empfohlen
Temperature and Thermocouple Monitoring
The AD7875KP can digitize conditioned temperature signals at up to 100 kHz, making it useful for multichannel systems that time-share through external analog multiplexing. A thermocouple amplifier provides amplification and cold-junction compensation before the signal reaches the unipolar 5 V input. The converter's 12-bit output supports process monitoring and setpoint control, while its sampling capability permits rejection of periodic interference when the acquisition timing and input filter are designed together.
Empfohlen
Process Control Instrumentation
The AD7875KP is appropriate for process-control inputs that require faster updates than a low-rate meter ADC but do not need resolution above 12 bits. A transmitter can scale its process variable to the converter's unipolar 5 V range, after which the ADC samples the conditioned signal at 100 kHz. The resulting code can feed a controller, alarm system, or data logger. Adequate input settling, grounding, and isolation between the analog field wiring and digital logic are essential for dependable operation.
Empfohlen
Digital Panel Meter
A digital panel meter can use the AD7875KP to convert a scaled sensor output into a numeric reading for local display or communication to a host. The 12-bit resolution provides 4,096 codes across the 5 V unipolar range, and the 100 kHz sampling rate supports responsive updates and input-noise averaging. A low-pass filter should determine how rapidly the displayed value follows the physical input, while the front end must avoid driving the converter beyond its permitted input range.
Empfohlen
Position and Motor Feedback
The AD7875KP can acquire conditioned position feedback from potentiometers, resolvers, or analog sensor networks when the selected interface produces a unipolar signal within 5 V. Its 100 kHz sampling rate supports responsive control-loop observation, and 12-bit resolution defines the quantization granularity available to the controller. The sensor amplifier and filter should be designed around acquisition time and signal bandwidth so that motion-dependent errors do not consume the available measurement resolution.
Empfohlen
Data Acquisition Module
The AD7875KP is suitable for compact data-acquisition modules that need one fast analog channel and a 12-bit digital result. The input amplifier can scale and isolate the source before conversion, while the ADC supplies up to 100,000 samples per second for analysis or storage. Because the converter uses a sampling architecture, the module must control trigger timing and preserve synchronization between the sampled voltage and the corresponding digital record. Local reference and supply routing remain critical to repeatable measurements.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für AD7875KP – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | AD7875LP |
|---|---|---|
| Brand | Analog Devices | Analog Devices |
| Package | 28-pin PLCC, 11.51 mm x 11.51 mm | 28-pin PLCC |
| Resolution | 12 bit | 12 bit |
| Sampling Rate | 100 kHz | 100 kHz |
| Architecture | Successive-approximation (SAR) | Successive-approximation (SAR) |
| Input Channel Count | 1 channel | 1 channel |
| Analog Input Range | Unipolar 5 V | Unipolar 5 V |
| Process Technology | CMOS LC2MOS | CMOS LC2MOS |
| Drop-In Status | Original device | Documented complete replacement |
Wichtigste Unterscheidungsmerkmale
- Documented same-package replacement path (vs. AD7875LP)
- Balanced conversion speed and resolution (vs. AD7875LP)
- Integrated single-channel acquisition (vs. AD7875LP)
Designhinweise
Design the analog input network for correct settling rather than treating the AD7875KP input as a fixed-resistance load. Select an amplifier or sensor interface with adequate output drive, include an anti-alias filter, and verify that the signal reaches its final value within the acquisition interval defined by the manufacturer. If the source impedance is high, verify the permitted source impedance and consider a buffer close to the converter.
Place input, reference, and supply bypass components close to their associated pins, and keep sensitive analog traces short and away from digital clocks or high-current switching paths. Use a continuous ground plane where practical and return analog and digital currents in a controlled manner. The 28-pin PLCC footprint requires careful thermal-pad and lead-orientation verification against the manufacturer package drawing before fabrication.
Do not equate the 100 kHz sampling rate with unlimited input bandwidth. A rapidly changing sensor waveform may require external filtering, track-and-hold behavior, or a faster sampling architecture to preserve accuracy. Also verify the unipolar 5 V range before connecting bipolar sensor outputs; improper level shifting can exceed the input limits and damage the converter.
Route supply and reference connections so that bypass capacitors can provide short, low-inductance current paths during each conversion. Follow the Analog Devices AD7875 data sheet, Rev. C, for required capacitor values, permitted ESR, and reference-decoupling details. Keep analog supply generation physically separated from noisy digital or switching circuitry, and validate supply stability at the converter pins under maximum conversion activity.
Compliance-Informationen
Compliance attributes were not identified for the exact AD7875KP ordering option. Do not infer automotive qualification, lead-free status, or substance declarations from the AD7875 family name alone.