ADM3222ARUZ - 3.3V Dual RS-232 Transceiver | Analog Devices
Teilenummer: ADM3222ARUZ ✓ AktivADM3222ARUZ Übersicht
An RS-232 transceiver is an interface IC that converts logic-level signals into RS-232 line levels and converts received line-level signals back into digital logic. In the product hierarchy, it belongs to the interface IC family and provides the physical-layer bridge between low-voltage digital equipment and a ±RS-232 communications link. The ADM3222 family is particularly useful when modern 3.3 V systems need to communicate with legacy RS-232 equipment.
The ADM3222ARUZ supports operation from a single +3.3 V supply, reducing the number of external rails required by portable and embedded equipment. Its two-channel transmitter and receiver arrangement supports full-duplex point-to-point links using two signal pairs. Enable and shutdown circuitry provides power-management control for systems that do not require the RS-232 interface to remain active continuously.
The charge-pump architecture generates the bipolar voltage required for RS-232 signaling from one low-voltage supply. Four external 0.1 µF capacitors are specified for this function. Designers must follow the manufacturer’s recommended capacitor type, voltage rating, and PCB placement because incorrect capacitor selection or long charge-pump loops can reduce reliability or increase circuit noise.
Typical uses include serial adapters, industrial instrumentation, data acquisition equipment, test systems, and portable instruments that need to connect a 3.3 V controller to an RS-232 port. The interface can also serve equipment with legacy DB9 connectors when the board-level design includes suitable protection, grounding, and cable-routing provisions.
A critical design consideration is that the external charge-pump capacitors belong directly beside the IC’s charge-pump pins; their connections should be short, symmetrical, and isolated from sensitive analog or high-speed digital traces. Power and ground planes must provide low-impedance return paths, while unused driver inputs and receiver outputs require defined logic states.
This product page combines the manufacturer’s interface specifications with package-level guidance, application-oriented design notes, and a structured comparison of compatible RS-232 transceivers. It is intended to accelerate component selection while preserving the distinctions required for dependable RS-232 implementation.
Drop-in-Alternativen für ADM3222ARUZ – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
Varianten dieser Serie
Modelle derselben Serie, die drop-in-kompatibel sind mit ADM3222ARUZ (gleiche Bauform und Footprint) – abweichend in Package, Interface Standard, Maximum Data Rate, Supply Voltage Range, Data Rate.
ADM3232EARUZ
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
MAX3232EIPWG4
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →ST3232BDR
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →ST3232BTR
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
ICL3222CVZ
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
ADM3222ARUZ Technische Daten
| Product Type | Dual RS-232 line driver/receiver |
| Number of Channels | 2 channels |
| Transmit Channels | 2 |
| Receive Channels | 2 |
| Maximum Data Rate | 230 kbps |
| Versorgungsspannung | +3.3 V |
| Interface Standard | RS-232 |
| Compatible Protocol | CCITT V.28 |
| Charge-Pump Capacitors | 4 external 0.1 µF capacitors |
| Enable and Shutdown Circuitry | Included |
| Gehäuse | 20-pin TSSOP |
| Montageart | Surface mount |
ADM3222ARUZ 20-pin tssop Pinbelegungsleitfaden
Pinbelegung für ADM3222ARUZ (20-pin tssop-Gehäuse). Pin-Nummerierung, Funktionen und Anschlussdiagramme sind im Herstellerdatenblatt definiert. Entnehmen Sie diesem den genauen Footprint und Lötrichtlinien.
Keine detaillierten Pinbelegungsdaten verfügbar für ADM3222ARUZ.
Siehe die Datenblatt für die vollständige Pin-Konfiguration.
Typische Anwendungen
ADM3222ARUZ ist geeignet für 6 Anwendungs: Portable RS-232 Test Instrument, Industrial Data Acquisition, Serial Communication Adapter, Instrumentation Control Interface, Network Equipment Management Port, Legacy Computer Connectivity.
Portable RS-232 Test Instrument
The ADM3222ARUZ fits portable test equipment that exposes a legacy RS-232 port while operating internally from +3.3 V. Its dual-channel architecture supports two transmit and two receive functions, and its enable and shutdown circuitry allows the interface to be disabled when measurements or battery life matter more than continuous connectivity. According to the Analog Devices product page, the maximum supported data rate is 230 kbps and the charge pump uses four external 0.1 µF capacitors. Place those capacitors close to the charge-pump pins and route the RS-232 connector ground return carefully to reduce noise and improve ESD-margin behavior in a compact handheld enclosure.
Empfohlen
Industrial Data Acquisition
The ADM3222ARUZ is appropriate for industrial data-acquisition equipment that must bridge a modern 3.3 V controller to RS-232 instruments or controllers. Two full-duplex channels reduce the number of interface ICs needed when separate transmit and receive paths are required, while the single +3.3 V supply simplifies system power design. Its stated 230 kbps capability is suitable for many configuration, logging, and command protocols. Designers should use the manufacturer’s charge-pump capacitor values and application circuit, provide a continuous ground reference to the RS-232 connector, and avoid placing the charge-pump return current through sensitive measurement-ground paths.
Empfohlen
Serial Communication Adapter
The ADM3222ARUZ can implement the line-driver and receiver section of a compact serial adapter where a 3.3 V host must connect to an RS-232 port. Its two transmit and two receive channels provide full-duplex communication, and the +3.3 V operating requirement allows direct compatibility with modern embedded logic. The four 0.1 µF charge-pump capacitors should follow the manufacturer’s exact circuit, including placement and capacitance tolerance. For a board intended for connection to external equipment, add the required protection network at the connector and keep the interface ground physically tied to the system reference plane.
Empfohlen
Instrumentation Control Interface
The ADM3222ARUZ is well matched to instrumentation that uses RS-232 for configuration commands and measurement results. A single +3.3 V supply reduces regulator complexity, while the dual-channel arrangement supports simultaneous command transmission and response reception. The interface’s 230 kbps maximum rate is ample for many ASCII and binary instrument protocols, although the complete system must still account for UART timing and cable length. Use deterministic enable control so the transceiver can be shut down between transactions, and validate the charge-pump layout with oscilloscope measurements before high-volume production.
Empfohlen
Network Equipment Management Port
The ADM3222ARUZ can support an RS-232 management connection on network or communications equipment that retains a legacy service port. Operating from +3.3 V helps integrate the transceiver with a modern control ASIC, while two channels permit full-duplex command and response traffic. The manufacturer states that the ADM3222 family complies with EIA-232E and CCITT V.28 and supports rates up to 230 kbps. In a rack-oriented product, keep the connector interface protected and maintain a low-impedance chassis or logic ground, while keeping charge-pump current out of the region carrying sensitive network signals.
Empfohlen
Legacy Computer Connectivity
The ADM3222ARUZ bridges a 3.3 V embedded controller to legacy RS-232 equipment such as service ports, programmers, and peripheral controllers. Its full-duplex two-channel architecture avoids implementing separate single-channel driver and receiver ICs, and shutdown support can reduce consumption when the legacy link is idle. The 230 kbps operating limit accommodates many legacy serial protocols, but software must still respect protocol timing and connector pin assignments. Use the Analog Devices family pin table and recommended application circuit to avoid misassigning the enable pin or charge-pump connections.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für ADM3222ARUZ – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | ADM3232EARUZ | MAX3232E | ST3232 | ST3232BTR | ICL3222CVZ |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Maxim Integrated | STMicroelectronics | STMicroelectronics | Renesas Electronics |
| Package | 20-pin TSSOP | 20-pin TSSOP | 20-pin TSSOP | 20-pin TSSOP | 20-pin TSSOP | 20-pin TSSOP |
| Interface Type | Dual RS-232 transceiver | Dual RS-232 transceiver | Dual RS-232 transceiver | Dual RS-232 transceiver | Dual RS-232 transceiver | Dual RS-232 transceiver |
| Number of Channels | 2 channels | 2 channels | 2 channels | 2 channels | 2 channels | 2 channels |
Wichtigste Unterscheidungsmerkmale
- Single-supply operation aligns directly with modern 3.3 V embedded systems (vs. MAX3232E)
- Family-supported alternative with the same 20-pin TSSOP class (vs. ADM3232EARUZ)
- Explicit enable and shutdown circuitry for controlled operation (vs. ST3232BTR)
Designhinweise
Place the four external 0.1 µF charge-pump capacitors directly beside the ADM3222ARUZ pins identified in the manufacturer application circuit. Keep each capacitor connection short, maintain a symmetrical charge-pump layout, and provide a continuous ground plane beneath the relevant circuitry. Do not substitute pins or capacitor connections based only on a generic RS-232 schematic because charge-pump routing is part of the device’s noise and reliability behavior.
Keep the RS-232 driver outputs and connector-side routing away from clocks, sensor inputs, and analog measurement signals. Route the interface ground as a controlled return path and connect it to the equipment reference plane at the appropriate system boundary. The Analog Devices layout guidance should be followed for exposed pad, power distribution, and thermal construction because the TSSOP package has limited heat-dissipation area.
Do not treat ADM3222ARUZ and ADM3222ARUZ-REEL7 as separate electrical devices; the latter denotes a reel-oriented order configuration. Also do not assume that any dual RS-232 transceiver is pin-compatible. Before substitution, verify the package drawing, pin table, supply range, data rate, charge-pump capacitor values, enable polarity, receiver thresholds, and shutdown state against the original design requirements.
Use the enable and shutdown functions to reduce power consumption when the RS-232 link is not required. Confirm the logic state that disables the interface and ensure external pull resistors do not defeat the intended shutdown behavior. Decouple the +3.3 V supply close to the device, follow the manufacturer’s supply capacitor recommendation, and verify startup behavior across the full voltage range used by the product.
Compliance-Informationen
Exact compliance declarations for ADM3222ARUZ were not identified. Confirm RoHS, REACH, lead-free, halogen-free, conflict-minerals, and automotive qualification status from current Analog Devices documentation before production release.