ADM3485EANZ - 3.3V 10Mbps RS-485/RS-422 Transceiver | Analog Devices
Teilenummer: ADM3485EANZ ✓ AktivADM3485EANZ Übersicht
A differential line transceiver is an interface IC that converts logic-level transmit and receive signals into balanced differential signals for reliable communication over long cables and electrically noisy environments. The ADM3485E family belongs to the transceiver hierarchy within interface ICs, where differential signaling improves common-mode noise rejection compared with single-ended communication. The ADM3485E shares differential lines and provides separate driver and receiver enable inputs.
Principal features include operation from a single 3.3 V supply, a 10 Mbps maximum data rate, low power consumption, and ±15 kV ESD protection. The half-duplex architecture supports shared-bus RS-485 networks in which connected nodes transmit and receive on the same pair of conductors. Compatibility with TIA/EIA RS-485 and RS-422 standards allows the device to be used in industrial instrumentation, building controls, factory automation, and distributed sensor networks.
The ADM3485E is a half-duplex transceiver that shares differential lines and has separate enable inputs for the driver and the receiver. This arrangement allows a node to be placed into a high-impedance receive state, preventing a disabled driver from interfering with an active bus. Independent enables also support controlled bus turnaround in systems where the application processor must not receive data while the local node transmits.
Typical uses include industrial sensor hubs, programmable logic controllers, building-automation controllers, motor-control modules, and remote I/O nodes. The 3.3 V supply matches modern controller platforms, while the 10 Mbps capability supports both moderate-speed telemetry and short high-speed links. Industrial temperature grading supports equipment expected to operate across extended ambient conditions.
When laying out a board, treat the bus-facing driver and receiver pins as high-current, high-transient-voltage nodes. Keep the differential route symmetrical, provide the interface's specified bus and termination networks, and follow the manufacturer's recommended grounding and decoupling arrangement. Separate driver-enable and receiver-enable controls should be driven by logic that cannot leave the bus in a contention state.
Drop-in-Alternativen für ADM3485EANZ – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
Varianten dieser Serie
Modelle derselben Serie, die drop-in-kompatibel sind mit ADM3485EANZ (gleiche Bauform und Footprint) – abweichend in ESD Protection, Maximum Data Rate, Product Type.
ADM3485EAN
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →SP3485EP-L
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
ADM3485ANZ
✅ Drop-In ⚠️ Spezifikationen ungeprüft📋 Referenzalternative (nicht im Katalog)
ADM3485EANZ Technische Daten
| Product Type | Low-power differential line transceiver |
| Versorgungsspannung | 3.3 V |
| Communication Mode | Half-duplex |
| Maximum Data Rate | 10 Mbps |
| Bus Standards | TIA/EIA RS-485 and RS-422 |
| ESD Protection | ±15 kV |
| Driver Enable | Separate enable input |
| Receiver Enable | Separate enable input |
| Betriebstemperaturbereich | Industrial grade |
| Gehäuse | 8-pin SOIC |
| Anzahl der Pins | 8 |
| Montageart | Surface mount |
| Logic Levels | 3.3 V compatible |
ADM3485EANZ 8-pin soic Pinbelegungsleitfaden
Pinbelegung für ADM3485EANZ (8-pin soic-Gehäuse). Pin-Nummerierung, Funktionen und Anschlussdiagramme sind im Herstellerdatenblatt definiert. Entnehmen Sie diesem den genauen Footprint und Lötrichtlinien.
Keine detaillierten Pinbelegungsdaten verfügbar für ADM3485EANZ.
Siehe die Datenblatt für die vollständige Pin-Konfiguration.
Typische Anwendungen
ADM3485EANZ ist geeignet für 6 Anwendungs: Industrial Sensor Bus Hubs, Building Automation Controllers, Factory Automation Remote I/O, Motor and Motion Control Modules, Programmable Controller Communication, Instrumentation and Measurement Equipment.
Industrial Sensor Bus Hubs
The ADM3485EANZ fits industrial sensor-hub controllers that collect measurements from remote nodes over a shared RS-485 bus. Its 3.3 V supply matches low-voltage embedded processors, while the listed 10 Mbps maximum rate supports short, high-throughput links. Separate driver and receiver enables let the hub enter a receive-only state while other nodes transmit, reducing bus contention. The ±15 kV ESD rating adds useful protection where field cables connect through industrial connectors. Design the board with closely decoupled supply pins, a symmetrical differential route, and bus termination only where the system architecture requires it.
Empfohlen
Building Automation Controllers
Building-automation controllers commonly distribute lighting, HVAC, and occupancy information across long RS-485 networks. The ADM3485EANZ provides balanced half-duplex communication from a 3.3 V logic domain and supports up to 10 Mbps for short links. Its independent enable inputs allow a controller to relinquish the shared bus reliably during transmit and receive switching. The ±15 kV ESD protection is particularly relevant where cables run through walls, junction boxes, and maintenance access areas. Follow the manufacturer application guidance for bus biasing, protection devices, and cable termination.
Empfohlen
Factory Automation Remote I/O
Remote I/O modules in factory automation often use half-duplex RS-485 to connect encoders, pressure transmitters, and digital sensors. The ADM3485EANZ supports a 10 Mbps rate, allowing it to handle both standard telemetry and short high-speed links while maintaining one compact 3.3 V transceiver. Separate driver-enable and receiver-enable pins support bus turnaround under firmware control. The industrial temperature grade and ±15 kV ESD protection make the interface appropriate for equipment exposed to electrically noisy factory environments. Keep the differential route away from motor power stages and high-current switching nodes.
Empfohlen
Motor and Motion Control Modules
The ADM3485EANZ can carry control and status information between a motion controller and distributed drive or position-feedback modules. Its balanced differential interface reduces susceptibility to common-mode noise found near motor drives, while separate enables allow a node to disconnect when it is not communicating. The 10 Mbps capability is useful for compact machines where encoder and status traffic travels over local cables. Place the transceiver at the connector-facing board edge, use a short ground reference near the bus connector, and apply the interface's recommended protection network. Verify ground offsets and cable length during motor-system integration.
Empfohlen
Programmable Controller Communication
Programmable controllers can use the ADM3485EANZ to bridge 3.3 V logic to a field bus without a separate physical-layer design. Its half-duplex RS-485 interface supports multipoint topologies, and the independent driver and receiver enable pins simplify controlled access to a shared bus. The device's 10 Mbps rating accommodates high-speed service data in addition to slower process variables. Because the transceiver is surface mount in an 8-pin SOIC, it can be placed close to the field connector and separated from sensitive analog circuitry. Confirm enable polarity in the controller firmware and use the datasheet's timing limits for turnaround delays.
Empfohlen
Instrumentation and Measurement Equipment
Test and measurement instruments frequently distribute commands and results between an instrument controller and peripheral instruments through RS-485. The ADM3485EANZ provides a 3.3 V, half-duplex differential interface with a maximum rate of 10 Mbps and ±15 kV ESD protection for bench and industrial installations. Separate enable controls allow an instrument to listen without driving the bus, which simplifies firmware-controlled bus management. Place the transceiver near the external connector, provide a direct chassis or board-ground strategy, and maintain a symmetric pair geometry. Use the manufacturer reference circuit for decoupling and bus protection.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für ADM3485EANZ – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | ADM3485EAN | SP3485EP-L | ADM3485ANZ |
|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Sipex | Analog Devices |
| Package | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC |
| Supply Voltage | 3.3 V | 3.3 V | 3.3 V | 3.3 V |
| Communication Mode | Half-duplex | Half-duplex | Half-duplex | Half-duplex |
| Bus Standards | TIA/EIA RS-485 and RS-422 | TIA/EIA RS-485 and RS-422 | RS-485 | TIA/EIA RS-485 and RS-422 |
| Number of Pins | 8 | 8 | 8 | 8 |
Wichtigste Unterscheidungsmerkmale
- Enhanced bus ESD protection within the ADM3485E family (vs. ADM3485ANZ)
- Separate controls for driver and receiver operation (vs. SP3485EP-L)
- 10 Mbps capability in a compact 8-pin SOIC (vs. ADM3485EAN)
Designhinweise
Route the differential pair as a tightly coupled, length-matched pair and keep it continuous between the transceiver and the board connector. Place the transceiver close to the connector so transient energy is clamped before it reaches sensitive logic. Avoid crossing the bus pair with switching-node copper, relay-driver outputs, or high-current motor traces. If the route must cross another layer, cross it at a right angle and maintain a ground reference beneath the pair where practical.
Follow the decoupling network in the Analog Devices ADM3485E application information and place the principal ceramic capacitor immediately across the transceiver supply and ground pins. Keep the high-frequency return path free of series inductance so switching current does not share the signal-reference path with the bus interface. A separate local regulator or filtered 3.3 V rail may be preferable when the transceiver shares a board with processors, display converters, or motor-control switching stages.
Do not assume that any 8-pin RS-485 transceiver is a drop-in replacement. Verify driver and receiver enable polarity, whether the receiver remains active during transmission, fail-safe biasing, differential output impedance, common-mode range, and shutdown-state behavior. These differences can prevent bus contention or cause a controller to receive echoed data even when the footprint matches. Complete a timing review for transmit-to-receive turnaround before substituting a different manufacturer's device.
The ±15 kV ESD rating protects the interface under defined test conditions but does not eliminate the need for an external bus protection strategy. Evaluate whether the cable entry requires TVS devices, surge protection, common-mode chokes, or chassis-grounding components. Keep protection devices close to the connector and away from the transceiver's sensitive receive inputs. Confirm that added protection capacitance does not reduce the usable signaling rate on long cables.
Compliance-Informationen
The Z ordering suffix commonly denotes a lead-free finish, but no explicit RoHS, REACH, AEC-Q100, halogen-free, or conflict-minerals statement was confirmed in the manufacturer or distributor pages. Use the manufacturer product declaration for the final compliance assessment.