ICL7106CPLZ - 3.5-Digit LCD A/D Converter | Renesas
Teilenummer: ICL7106CPLZ ✓ AktivICL7106CPLZ Übersicht
A 3.5-digit A/D converter is a low-complexity ADC optimized for measuring a selected decimal range rather than delivering high-resolution binary data. The final fractional digit normally represents a tenths position. In the signal-chain hierarchy, the ICL7106CPLZ belongs to the ADC/DAC class of data-conversion ICs and integrates the converter, display decoder, display driver, reference, and timing functions needed for a direct-reading instrument.
The ICL7106CPLZ integrates a seven-segment decoder and LCD driver, eliminating separate logic for common multiplexed LCD instruments. It also includes an internal reference and clock. According to the Renesas product description, the true differential input and reference support ratiometric measurements, allowing the converter to measure resistance and bridge-transducer signals when the reference and input relationships are appropriately scaled. The LCD-specific output distinguishes this device from the ICL7107 family, which directly drives LED displays.
A useful implementation detail is that the converter is designed around an integration-based measurement cycle rather than a conventional high-speed sampling architecture. This favors stable, readable measurements over rapid waveform acquisition. For instrument design, the overall accuracy depends not only on the converter but also on reference accuracy, input filtering, analog-front-end design, layout cleanliness, and display resolution. The integrated clock and reference reduce external component count, while the LCD driver simplifies direct panel-meter construction.
Typical uses include digital panel meters, temperature indicators, laboratory meters, process-monitoring displays, weighing indicators, and low-cost sensor interfaces. It is particularly suitable for battery-operated equipment because the manufacturer describes it as a high-performance, low-power converter. In portable instruments, low quiescent power and direct LCD drive can reduce both board area and the number of power-management stages required around the display.
The most important design consideration is preserving the correct LCD drive architecture. The ICL7106 is intended for multiplexed LCD panels with backplane drive, so it should not be substituted for an LED-output ICL7107 without reviewing the display wiring. Input and reference filtering, common-mode range, input-to-reference ratio, and allowable operating conditions must also be checked against the manufacturer datasheet before layout release.
This product page combines the ICL7106CPLZ function, package information, sourcing workflow, comparison criteria, and application guidance. It also distinguishes true pin-compatible replacements from merely similar ICL7106 or ICL7107 devices, helping engineers screen candidates before committing to a PCB or production BOM.
Drop-in-Alternativen für ICL7106CPLZ – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
Varianten dieser Serie
Modelle derselben Serie, die drop-in-kompatibel sind mit ICL7106CPLZ (gleiche Bauform und Footprint) – abweichend in Display Output, Mounting Type, Integrated Clock, Integrated Reference, Product Type.
ICL7106CPL+
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →ICL7106CPL+
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →ICL7106CPLZ Grenzwerte & elektrische Eigenschaften
| ADC Resolution | 3.5 digits |
| Converter Architecture | Dual-slope A/D conversion |
| Display Output | Multiplexed LCD drive |
| Integrated Display Decoder | Seven-segment decoder |
| Integrated Reference | Yes |
| Integrated Clock | Yes |
| Input Type | True differential input |
| Gehäuse | 40-pin dual inline package |
| Pin-Anzahl | 40 pins |
| Power Class | Low-power A/D converter |
| Montageart | Through-hole insertion |
| Reference Input | True differential reference |
| Ratiometric Measurement Support | Supported |
ICL7106CPLZ 40-pin dual inline package Pinbelegungsleitfaden
Pinbelegung für ICL7106CPLZ (40-pin dual inline package-Gehäuse). Dieses analoge Bauteil verfügt über Eingangs-, Ausgangs- und Versorgungspins. Offset-Null-, Kompensations- und Enable-Pin-Konfigurationen entnehmen Sie dem Herstellerdatenblatt. Ideal für Signalaufbereitung und Verstärkerschaltungen.
Keine detaillierten Pinbelegungsdaten verfügbar für ICL7106CPLZ.
Siehe die Datenblatt für die vollständige Pin-Konfiguration.
Typische Anwendungen
ICL7106CPLZ ist geeignet für 6 Anwendungs: Digital Panel Meter, Digital Temperature Indicator, Resistance Meter, Bridge Transducer Interface, Process Monitoring Display, Battery-Powered Test Instrument.
Digital Panel Meter
The ICL7106CPLZ is well suited to direct-reading digital panel meters because its 3.5-digit converter, seven-segment decoder, and multiplexed LCD driver share one 40-pin package. A panel can therefore be driven without a separate display-decoder IC, reducing component count and simplifying the analog input path. The design remains centered on a stable measurement rather than fast sampling. Input filtering, reference selection, and LCD segment mapping must follow the manufacturer pin and application tables. Confirm the panel's backplane count and segment connections before layout release so that every multiplexed output is assigned to the correct LCD electrode.
Empfohlen
Digital Temperature Indicator
A temperature-display instrument can use the ICL7106CPLZ to convert a conditioned sensor voltage into a readable 3.5-digit LCD result. Its integrated clock, reference, seven-segment decoder, and LCD driver reduce the number of separate digital and display-support components. For a linear sensor, the analog front end must scale the output into the converter's input range, while cold-junction compensation may require a dedicated reference device. The 0.1-count display resolution is useful for compact panel instruments, although overall system accuracy remains governed by sensor calibration, resistor tolerances, reference accuracy, and temperature drift.
Empfohlen
Resistance Meter
The ICL7106CPLZ can support resistance measurement because its true differential input and reference architecture permits ratiometric operation. A switched ohmmeter-style front end drives a known current through the unknown resistance, and the converter reports the resulting ratio relative to its reference. This arrangement is useful in low-cost handheld meters and educational instruments. Stable reference voltage, switch resistance, input leakage, and resistor-network accuracy directly affect the displayed result. Use the manufacturer's measurement guidance to select source resistance and filtering while keeping the analog traces away from the multiplexed LCD drive nodes.
Empfohlen
Bridge Transducer Interface
The true differential input and reference channels of the ICL7106CPLZ make it suitable for bridge-based transducers whose output changes proportionally with a physical quantity. The analog front end can excite the bridge and condition its small differential signal before conversion, while the integrated display functions produce a direct numerical reading. Ratiometric operation can reduce errors caused by reference variation when the bridge and converter reference share suitable excitation. The bridge excitation, permissible common-mode range, input resistance, and converter supply limits must be reviewed together. Grounding and shielding are especially important when the bridge output is small relative to the converter's measurement range.
Empfohlen
Process Monitoring Display
The ICL7106CPLZ fits industrial process-monitoring panels that present one slowly changing measurement on an LCD. Its integrated clock, reference, converter, and display driver minimize the number of components required for a dedicated readout, while low power is valuable in unattended instruments. A transmitter output can be scaled into the converter's input range and filtered to reject process noise. Because the ICL7106 is optimized for stable numerical readings rather than high-speed sampling, it is better suited to supervisory displays than waveform acquisition. Panel layout should preserve separation between sensitive analog inputs and multiplexed LCD outputs, and the enclosure should limit electromagnetic pickup around long sensor cables.
Empfohlen
Battery-Powered Test Instrument
A handheld meter can use the ICL7106CPLZ to combine measurement and display functions in a low-power 40-pin device. Integrated timing, reference, decoding, and LCD drive reduce the need for separate support ICs, which can save board area in a portable instrument. Low power is especially valuable when the display and converter operate from a small battery or energy-harvesting source. The display duty cycle, reference current, input circuitry, and power-gating strategy should be evaluated together because each affects the overall energy budget. The LCD must also be checked for compatibility with the converter's multiplexed backplane drive and operating limits.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für ICL7106CPLZ – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | ICL7106CPL | ICL7106CPL+ |
|---|---|---|---|
| Package | 40-pin dual inline package | 40-pin dual inline package | 40-pin dual inline package |
| Brand | Renesas Electronics | Renesas Electronics | Maxim Integrated |
| Display Resolution | 3.5 digits | 3.5 digits | 3.5 digits |
| Display Type | Multiplexed LCD | Multiplexed LCD | Multiplexed LCD |
| Integrated Seven-Segment Decoder | Yes | Yes | Yes |
| Input Configuration | True differential input | True differential input | True differential input |
| Power Class | Low-power converter | Low-power converter | Low-power converter |
Wichtigste Unterscheidungsmerkmale
- Combines conversion and LCD display functions in one device (vs. ICL7106CPL+)
- Supports true differential ratiometric measurements (vs. ICL7106CPL)
- Uses the same 40-pin footprint as the closest LCD-family candidates (vs. ICL7106CPL)
- Avoids LED-display mismatch (vs. ICL7107RCPLZ)
Designhinweise
Route the analog input and reference nets as short, quiet traces away from the multiplexed LCD outputs. Place input filtering and reference components close to their associated pins, and keep the LCD connector and backplane traces isolated from the measurement front end. A grounded guard or shielding strategy may be needed when the source impedance is high or the measured signal is small. Ground-plane continuity beneath the converter is important, but avoid routing sensitive inputs over split or discontinuous return paths.
Do not treat the ICL7107 as an equivalent display solution. The ICL7106CPLZ provides multiplexed LCD backplane drive, whereas the ICL7107 family is intended for direct LED drive. Confirm the display glass pinout, segment count, backplane arrangement, and drive waveform before ordering either the converter or the LCD. An apparently similar 3.5-digit conversion function is not sufficient evidence that two parts are pin-compatible.
Verify the exact suffix-specific operating temperature, supply range, accuracy, and qualification limits before releasing a substitute. ICL7106CPL and ICL7106CPL+ appear in the relevant product and cross-reference information, but matching the 40-pin package and LCD function does not by itself establish equivalent production ratings. Preserve the original MPN in the schematic and bill of materials until a manufacturer-to-manufacturer comparison and qualification review are complete.
Use the converter's ratiometric input and reference architecture when the measurement depends on a shared excitation, such as a resistance or bridge-transducer circuit. This can reduce errors caused by common reference variation, but it does not remove errors from switch resistance, resistor tolerance, input leakage, or bridge self-heating. Evaluate the analog front end across the required temperature and supply ranges rather than relying only on nominal resistor values.
Compliance-Informationen
No explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals statement was identified for the exact ICL7106CPLZ ordering code. AEC-Q100 is not applicable because this is not an automotive-qualified device in the available product information.