ICL7129CM44 Übersicht

The Intersil ICL7129CM44 is a 4½-digit, single-chip CMOS analog-to-digital converter with a multiplexed 4-digit LCD output, housed in a 44-MQFP surface-mount package measuring 10 mm by 10 mm. It uses a dual-slope conversion technique, provides one measurement channel, and operates from 0°C to 70°C. The device is designed for direct LCD excitation, reducing the external circuitry required in digital panel-meter and laboratory measurement equipment.

An analog-to-digital converter, or ADC, converts an analog input voltage into a digital numerical representation. The ICL7129CM44 belongs to the special-purpose ADC category and integrates conversion control, digital processing, and multiplexed LCD drive functions. Its integrated LCD interface allows one analog measurement to be presented directly through the display electrodes without requiring a separate display controller in straightforward instrument designs.

The principal features of the ICL7129CM44 include 4½-digit resolution, one analog input channel, direct multiplexed LCD drive, and dual-slope conversion. The 44-terminal surface-mount package provides separate connections for the analog measurement path, reference circuitry, display multiplexing, digital drive signals, and control functions. A square gull-wing package supports conventional PCB assembly, while the 10 mm by 10 mm body size balances display connectivity against board-area requirements.

Because the ICL7129CM44 integrates the conversion function and LCD drive circuitry, the system designer must pay particular attention to reference stability, input-source impedance, analog grounding, and display segment layout. The conversion architecture is intended for relatively slow measurement rates rather than high-speed waveform acquisition. Its commercial operating range of 0°C to 70°C suits laboratory meters, panel instruments, weighing equipment, and embedded measurement displays where environmental operation beyond commercial temperature is not required.

Typical uses include laboratory digital multimeters, bench panel meters, temperature-measurement instruments, process monitoring displays, portable test equipment, and laboratory instruments with multiplexed LCD readouts. The direct LCD drive is particularly useful when the measured value must remain visible without a separate graphics processor. Systems requiring more display multiplexing, faster acquisition, or extended-temperature operation should evaluate the timing, input, and environmental limits against the application requirements.

Layout guidance should preserve a low-impedance analog path from the measured input to the converter, maintain a quiet return for the reference and analog pins, and route display-drive signals away from sensitive input nodes. Follow the pin-description table and reference-circuit example in the Intersil ICL7129 datasheet when assigning tracks and selecting passive components. Verify startup settling, input filtering, LCD contrast, and intended measurement range in the assembled prototype.

This page organizes the Intersil ICL7129CM44 device data with application guidance, a specification checklist, compatibility boundaries, and practical design considerations. It also distinguishes documented drop-in replacements from suffix or packaging variants so engineers can make a controlled replacement decision without confusing commercial ordering codes with functional equivalence.

Drop-in-Alternativen für ICL7129CM44 – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Für dieses Produkt sind keine Drop-in-Alternativen verfügbar.

Alternativen anfordern

ICL7129CM44 Grenzwerte & elektrische Eigenschaften

Device Type 4½-digit single-chip A/D converter
ADC Resolution 4½ digits
Display Output 4-digit multiplexed LCD
Conversion Architecture Dual-slope
Number of Channels 1 channel
Process Technology CMOS
Package Type 44-MQFP
Package Dimensions 10 mm x 10 mm
Package Shape Square
Terminal Form Gull wing
Number of Terminals 44 terminals
Montagestil Surface mount
Betriebstemperatur 0°C to 70°C
Temperature Grade Commercial

ICL7129CM44 square Pinbelegungsleitfaden

Pinbelegung für ICL7129CM44 (square-Gehäuse). Dieses analoge Bauteil verfügt über Eingangs-, Ausgangs- und Versorgungspins. Offset-Null-, Kompensations- und Enable-Pin-Konfigurationen entnehmen Sie dem Herstellerdatenblatt. Ideal für Signalaufbereitung und Verstärkerschaltungen.

Pinbelegungsdiagramm für ICL7129CM44 im square-Gehäuse

Keine detaillierten Pinbelegungsdaten verfügbar für ICL7129CM44.

Siehe die Datenblatt für die vollständige Pin-Konfiguration.

Typische Anwendungen

ICL7129CM44 ist geeignet für 6 Anwendungs: Laboratory Digital Panel Meter, Digital Multimeter, Temperature Measurement Instrument, Process Monitoring Display, Portable Measurement Instrument, Bench Test Equipment.

🔬

Laboratory Digital Panel Meter

The ICL7129CM44 suits a laboratory panel meter because its 4½-digit, one-channel dual-slope ADC and direct multiplexed 4-digit LCD drive consolidate measurement and display functions. The converter can present a stabilized numerical reading without a separate display controller, reducing the number of active devices around the display. Its 0°C to 70°C commercial range aligns with conventional bench equipment. The design should use the manufacturer's reference and application circuit, preserve a quiet analog return, and verify conversion settling before every calibration point.

⚡

Digital Multimeter

The ICL7129CM44 is appropriate for a basic digital-multimeter front end when the instrument measures one analog quantity and uses a 4-digit LCD. The integrated multiplexed LCD driver allows the conversion result to be displayed directly, while the 4½-digit internal resolution supports readable increments across the selected range. The single-channel architecture means range selection and signal conditioning remain external design tasks. Follow the Intersil application circuit for input resistance, reference routing, filter components, and display timing, then validate leakage and accuracy across the complete voltage range.

🌡️

Temperature Measurement Instrument

The ICL7129CM44 can form the measurement core of a temperature display when a sensor-conditioning network converts temperature into a suitable analog voltage. Its dual-slope conversion method is suited to slow, repeatable measurements, and the integrated 4-digit LCD drive provides a compact direct readout. One analog channel limits concurrent sensing, so multiplex or alternate designs may be needed for multiple probes. Validate input protection, sensor excitation, reference stability, conversion duration, and display update behavior across the intended temperature range.

🏭

Process Monitoring Display

The ICL7129CM44 is useful in industrial panel monitoring when the target signal requires a stable, readable numeric indication rather than high-speed sampling. Its 4½-digit format and integrated multiplexed LCD drive reduce the display subsystem to one converter plus the required passive support components. The commercial 0°C to 70°C range is suitable for controlled indoor equipment, but not for extended-temperature locations without additional qualification. Place protection, filtering, and calibration components ahead of the converter, and isolate display-drive traces from sensitive analog input routing.

📱

Portable Measurement Instrument

The ICL7129CM44 fits a portable measurement instrument that prioritizes a clear numerical display and simple analog-to-digital conversion over rapid sampling. The single-chip integration reduces the component count associated with driving a multiplexed 4-digit LCD, which can help simplify a compact PCB. Because the converter is intended for relatively slow measurements, intermittent or continuously updated thermal, pressure, or laboratory signals are better candidates than fast transient capture. Confirm supply-voltage limits and power-consumption requirements directly against the manufacturer datasheet.

🔧

Bench Test Equipment

The ICL7129CM44 is well matched to bench instruments that present a stable measurement result on an integrated LCD. Its one-channel dual-slope conversion architecture supports stable readings from suitable sensor or conditioning circuits, and its direct display drive can eliminate a separate display-control IC in straightforward designs. The commercial operating range covers typical indoor laboratory use. Designers should reproduce the reference layout, account for input leakage and protection-network leakage, and verify that the selected acquisition interval satisfies the instrument's measurement responsiveness.

What is the ICL7129CM44?
The ICL7129CM44 is a 4½-digit, single-chip CMOS analog-to-digital converter that directly drives a multiplexed 4-digit liquid-crystal display. According to the Intersil ICL7129 datasheet, it uses a dual-slope conversion architecture, provides one measurement channel, and requires only a reference and passive external components for operation. The device is packaged in a 44-MQFP surface-mount package measuring 10 mm by 10 mm.
Where can I download the ICL7129CM44 datasheet PDF?
The ICL7129CM44 datasheet PDF is available from the Intersil ICL7129 document link listed on this page. The manufacturer datasheet contains the functional description, application circuit, electrical characteristics, LCD-drive information, and package details needed for design work. Use the pin-description table and connection diagrams when assigning the 44-MQFP footprint rather than relying on a distributor category summary.
Where can I find the ICL7129CM44 pinout?
The ICL7129CM44 pinout is documented in the Intersil ICL7129 manufacturer datasheet, which covers the 44-terminal MQFP connection arrangement. Use the package pin-description table to identify analog inputs, reference connections, LCD drive outputs, and control pins. The package drawing also defines the orientation of pin 1 and the gull-wing lead geometry, both of which should be cross-checked before PCB routing.
What are the key specifications of ICL7129CM44 that engineers should know?
The ICL7129CM44 combines a 4½-digit, one-channel dual-slope ADC with direct multiplexed 4-digit LCD drive in a 44-MQFP package. According to the Intersil ICL7129 datasheet, it is a CMOS device intended to operate with a reference and a small group of passive components. Its commercial temperature range is 0°C to 70°C, and the package measures 10 mm by 10 mm.
Where can I buy ICL7129CM44 online?
Use the Request a Quote form on this page to request ICL7129CM44 availability, commercial terms, and a delivery commitment for the exact 44-MQFP ordering code. The form is the appropriate route for confirming quantity, traceability, package condition, and lead time. Record the requested manufacturer part number and intended annual usage so the quotation can be matched to the correct production configuration.
What is the price of ICL7129CM44?
Current commercial pricing for the ICL7129CM44 depends on quantity, condition, traceability, and delivery terms. Submit the exact MPN through the Request a Quote form on this page for a current quotation. The structured price fields on this page are refreshed independently and should be used for commercial planning rather than values quoted in general technical documentation.
What is the lead time for ICL7129CM44?
Lead time for ICL7129CM44 depends on current manufacturer and distribution inventory, order quantity, and the condition required by the project. Request a current lead-time commitment through the Request a Quote form on this page. For production planning, include the annual forecast and whether date-code, traceability, or factory-sealed packaging is mandatory.
Is ICL7129CM44 in stock?
Current stock for the exact ICL7129CM44 ordering code must be confirmed through the Request a Quote form on this page. The manufacturer part number identifies a 44-MQFP commercial-temperature device, while other suffix and packaging codes represent different orderable configurations. Ask the supplier to confirm the package marking, production status, quantity, and earliest shipment date against your requirements.
ICL7129CM44 vs ICL7129CM44T - which is better?
ICL7129CM44T is the tape-and-reel ordering variant of ICL7129CM44, while the base part is normally associated with bulk or tray presentation. Both identify the same 44-MQFP ICL7129 device family, so functional choice is not determined by the packaging suffix. Select the suffix that matches the PCB assembly process and then confirm the exact quantity and shipping format through the Request a Quote form.
What can replace ICL7129CM44?
No verified cross-manufacturer, pin-to-pin replacement for ICL7129CM44 is established on this page. The ICL7129CM44T tape-and-reel code is an ordering-format counterpart of the target device, but it is not a different converter and is not listed as a separate engineering alternative. A valid replacement must match the 44-MQFP footprint, analog and reference architecture, LCD-drive functions, timing, electrical limits, and operating-temperature requirements.
Is ICL7129CM44 the same as ICL7129CM44T?
The ICL7129CM44 and ICL7129CM44T use the same Harris/Intersil ICL7129 device designation, with the T suffix identifying the tape-and-reel order format. Both are listed in the 44-MQFP family and therefore match the target package. Treat them as commercial order variants rather than separate functional alternatives, and verify the exact suffix against your assembly and incoming-inspection requirements.
When should I choose ICL7129CM44 over a generic LCD ADC?
Choose the ICL7129CM44 when the design needs a 4½-digit measurement with direct 4-digit multiplexed LCD drive and can use the device's dual-slope architecture and commercial temperature range. It is particularly suitable for panel meters and laboratory instruments where a separate display controller would add complexity. A generic ADC may be preferable for faster sampling, more inputs, higher resolution, or different environmental requirements.
Is ICL7129CM44 suitable for laboratory panel meters?
The ICL7129CM44 is suitable for many laboratory panel-meter applications because it integrates a 4½-digit dual-slope ADC with multiplexed LCD drive and requires only a reference and passive components. Its 0°C to 70°C commercial range and one-channel architecture suit conventional bench instruments. Verify input range, reference accuracy, conversion timing, and leakage requirements against the complete measurement chain.
Can ICL7129CM44 be used for temperature measurement?
The ICL7129CM44 can support temperature measurement when the sensor and signal path produce a voltage within the converter's permitted input range. Its 4½-digit resolution and direct LCD drive suit direct panel readouts, while the dual-slope conversion method is appropriate for relatively slow thermal measurements. Apply input protection and filtering, and confirm the specified conversion interval and reference accuracy before finalizing the measurement accuracy.
What compliance documents are available for ICL7129CM44?
The ICL7129CM44's RoHS, REACH, lead-free, halogen-free, and conflict-minerals status must be confirmed for the applicable production and packaging configuration. Request current material and environmental declarations through the Request a Quote form on this page, specifying the exact MPN. The ICL7129 family description identifies a commercial-temperature CMOS device, but it does not by itself establish the complete compliance declaration for every orderable configuration.

Technische Referenzdaten für ICL7129CM44 – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose the ICL7129CM44 for a one-channel, 4½-digit instrument that uses a 4-digit multiplexed LCD and needs the converter and display driver in a single 44-MQFP device. Its dual-slope architecture is appropriate for relatively slow, stable measurements such as temperature, pressure, and laboratory readings rather than high-speed waveform capture. The 0°C to 70°C commercial range suits controlled indoor equipment. ICL7129CM44T is the tape-and-reel order format of the same device family and may be selected when that packaging matches the assembly line, but it is not a separate functional alternative. Before approving a replacement, require an exact match for the 44-MQFP footprint, input and reference architecture, LCD segment mapping, control signals, conversion timing, supply limits, and temperature range. Also verify the intended measurement accuracy, input leakage, acquisition interval, reference stability, and display update behavior in the assembled circuit.

Vergleich mit Alternativen

Parameter Dieses Produkt
Package 44-MQFP (10 mm x 10 mm)
Brand Intersil
ADC Resolution 4½ digits
Display Output 4-digit multiplexed LCD
Conversion Architecture Dual-slope
Number of Channels 1 channel
Process Technology CMOS
Operating Temperature 0°C to 70°C
Mounting Style Surface mount
Lifecycle Status Active

Designhinweise

Keep the analog input, reference, and converter return paths compact and isolated from the multiplexed LCD drive nets. Route sensitive input traces away from display outputs and switching nodes, and use a continuous ground reference beneath the analog section where the board stackup permits. Place input and reference components close to their associated pins, following the placement shown in the Intersil ICL7129 application circuit.

Design the input network so leakage from protection diodes, switches, and guarding resistors does not degrade the 4½-digit measurement. Begin with the input impedance and leakage requirements in the manufacturer datasheet, then add filtering only after confirming its effect on acquisition settling. A filter capacitor placed near the input can reduce noise but may interact with the dual-slope conversion timing, so validate the complete settling sequence.

Use the package drawing and pin-description table to establish pin 1 orientation before placing the 44-MQFP device. Check the 10 mm by 10 mm body, gull-wing lead geometry, pad dimensions, and courtyard against the PCB library rather than relying only on the generic QFP name. Because LCD drive, analog input, and control functions share the package, incorrect pin numbering can produce a board that assembles but cannot measure correctly.

Do not treat ICL7129CM44T as a distinct functional alternative when performing a replacement review; it is the tape-and-reel ordering version of the same ICL7129 device. Conversely, do not assume that another LCD ADC with a similar display function is pin-compatible. Verify analog input definition, reference topology, conversion timing, LCD segment mapping, control polarity, electrical limits, and operating temperature before approving any substitute.

Compliance-Informationen

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Bleifrei
Unknown
Halogenfrei
Unknown
Konfliktmineralien
Unknown

The device is categorized as a commercial-temperature CMOS ADC, but no specific RoHS, REACH, lead-free, halogen-free, or conflict-minerals declaration was established for this ordering configuration. Request current material compliance documentation for the exact MPN and packaging code.

Daten verifiziert am: 2026-11-24 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

ICL7129CM44 datasheet ICL7129CM44 pinout ICL7129CM44 datasheet PDF ICL7129CM44 specifications ICL7129CM44 equivalent ICL7129CM44 replacement ICL7129CM44 cross reference ICL7129CM44 footprint ICL7129CM44 price ICL7129CM44 stock Intersil ICL7129CM44 ICL7129CM44 application circuit ICL7129CM44 vs ICL7129CM44T what is the ICL7129CM44

Verwandte Bauteile & Begriffe

Intersil Harris Corporation ICL7129CM44 ICL7129CM44T ICL7129 analog-to-digital converter ADC special-purpose ADC 4½-digit ADC dual-slope converter multiplexed LCD 4-digit LCD CMOS integrated circuit liquid-crystal display 44-MQFP QFP package family surface-mount package panel meter laboratory instrument temperature measurement process monitoring reference voltage input impedance conversion timing commercial temperature grade
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen