Texas Instruments

INA141PA - Precision 10/100 V/V Instrumentation Amplifier | Texas Instruments

Teilenummer: INA141PA ✓ Aktiv
±18 V Vdss 5 nA maximum Id 8-pin plastic DIP Package
MOQ: 1 |

INA141PA Übersicht

The Texas Instruments INA141PA is a precision, low-power instrumentation amplifier with selectable gains of 10 V/V or 100 V/V, supplied in an 8-pin plastic DIP package. It is designed for measuring small differential signals while rejecting common-mode noise and offset. The device provides low offset voltage of 50 µV maximum, low input bias current of 5 nA maximum, and high common-mode rejection of 117 dB minimum. Its input stage supports input protection to ±40 V, while its wide ±18 V supply range allows operation from both single-split and dual-supply systems.

An instrumentation amplifier is a specialized amplifier category that combines differential input measurement, high input impedance, accurate gain setting, and strong common-mode rejection into one device. It sits between sensors, bridge transducers, and precision converters in the signal-chain hierarchy: instrumentation amplifier -> operational amplifier -> analog signal-processing IC. The INA141PA uses a three-op-amp instrumentation-amplifier architecture with current-feedback input circuitry. According to the Texas Instruments datasheet, this configuration maintains a bandwidth of 200 kHz even at a gain of 100 V/V.

Key features include accurate gain selection, low offset drift of 0.5 µV/°C maximum, low quiescent current, and operation across a -40 °C to +85 °C temperature range. The 10 V/V and 100 V/V gain choices make the device useful for bridge sensors, biomedical instrumentation, current measurement, and industrial sensor interfaces where the signal is small relative to the common-mode voltage.

The INA141PA is available in an 8-pin plastic DIP package, which is useful for through-hole prototypes, laboratory equipment, and legacy industrial boards. The DIP package also provides a straightforward mechanical format for socket-based designs. Its input protection rating of ±40 V helps protect the measurement inputs when external wiring or sensors can present transients beyond the normal operating signal range.

Typical applications include strain-gauge and RTD bridge amplifiers, precision current shunt measurements, ECG and other biomedical instrumentation, sensor acquisition modules, and laboratory test equipment. The main design consideration is ensuring the common-mode voltage, supply rails, gain configuration, and input protection limits remain within the device specifications. Stable reference bypassing and careful grounding are also important when measuring microvolt-level signals.

This page synthesizes the verified manufacturer information, package details, technical trade-offs, and drop-in replacement considerations to support faster component selection, PCB planning, and purchasing decisions.

Drop-in-Alternativen für INA141PA – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Varianten dieser Serie

Modelle derselben Serie, die drop-in-kompatibel sind mit INA141PA (gleiche Bauform und Footprint) – abweichend in Architecture, Package, Product Type, Supply Voltage Range, Maximum Offset Drift.

Texas Instruments
Architecture: Two-op-amp instrumentation amplifier
Package: 8-pin PDIP
Product Type: Precision micropower instrumentation amplifier
Vergleichen mit INA141PA →
Texas Instruments
Package: 8-pin plastic DIP (PDIP)
Supply Voltage Range: ±2.25 V to ±18 V
Vergleichen mit INA141PA →
Texas Instruments
Architecture: Three-op-amp instrumentation-amplifier design
Package: 8-pin plastic DIP (PDIP)
Product Type: Precision low-power instrumentation amplifier
Vergleichen mit INA141PA →
Texas Instruments
Architecture: Three-op-amp instrumentation-amplifier design
Maximum Offset Drift: 0.5 µV/°C
Vergleichen mit INA141PA →

INA141P

✅ Drop-In
Texas Instruments
📦 8-PDIP
Precision, low-power instrumentation amplifier · 10 and 100 V/V · 50 µV · 0.5 µV/°C · 5 nA · 117 dB · ±40 V · ±18 V

Preis auf Anfrage

Datenblatt ansehen →

INA131AP-1

✅ Drop-In
📦 8-PDIP
Verified cross-reference states consistent terminals, package, and functional characteristics; gain configuration should be verified against the target design.

📋 Referenzalternative (nicht im Katalog)

INA126P

✅ Drop-In ⚠️ Spezifikationen ungeprüft
Texas Instruments
📦 8-PDIP
Precision micropower instrumentation amplifier · Two-op-amp instrumentation amplifier · 36 V · ±1.35 V to ±18 V · 175 µA/channel typical · 250 µV · 1, 10, 100, or 1000 using external resistor · Precision low-noise differential input

Preis auf Anfrage

Datenblatt ansehen →

INA128P

✅ Drop-In ⚠️ Spezifikationen ungeprüft
Texas Instruments
📦 8-PDIP
Precision instrumentation amplifier · Three-op-amp instrumentation amplifier · 130 dB minimum · 50 µV maximum · 0.5 µV/°C maximum · 5 nA maximum · ±40 V · ±2.25 V to ±18 V

Preis auf Anfrage

Datenblatt ansehen →

INA129P

✅ Drop-In ⚠️ Spezifikationen ungeprüft
Texas Instruments
📦 8-PDIP
Precision low-power instrumentation amplifier · 1 · 8-pin plastic DIP (PDIP) · Through-hole · 50 uV · 0.5 uV/°C · 5 nA · 120 dB

Preis auf Anfrage

Datenblatt ansehen →

INA141PA Grenzwerte & elektrische Eigenschaften

Product Type Precision instrumentation amplifier
Gain 10 V/V or 100 V/V
Architecture Three-op-amp instrumentation amplifier
Input Protection ±40 V
Supply Range ±18 V
Offset Voltage 50 µV maximum
Offset Drift 0.5 µV/°C maximum
Input Bias Current 5 nA maximum
Common-Mode Rejection 117 dB minimum
Bandwidth at Gain 100 V/V 200 kHz
Betriebstemperatur -40 °C to +85 °C
Gehäuse 8-pin plastic DIP
Montageart Through-hole
Number of Circuits 1 circuit

INA141PA Pin-Konfiguration

DIP-8 Package Pinout Diagram DIP-8 8-pin dual inline, 7.62mm pitch, JEDEC MS-001. 1 8 2 7 3 6 4 5 DIP-8
Pin 1 RG — Gain-setting resistor connection
Pin 2 -IN — Inverting input
Pin 3 +IN — Noninverting input
Pin 4 V- — Negative supply connection
Pin 5 REF — Reference input
Pin 6 OUT — Amplified output
Pin 7 V+ — Positive supply connection
Pin 8 RG — Gain-setting resistor connection

Typische Anwendungen

INA141PA ist geeignet für 6 Anwendungs: Precision Bridge Sensor Measurement, Industrial Current Shunt Amplification, Biomedical Signal Acquisition, Sensor Interface and Data Acquisition, Laboratory Measurement Instrumentation, Battery-Powered Portable Instrument.

🏭

Precision Bridge Sensor Measurement

The INA141PA fits strain-gauge, load-cell, and resistive bridge measurements where the useful signal is differential and the bridge excitation establishes a substantial common-mode level. Its selectable 10 V/V or 100 V/V gain reduces the need for a separate gain stage, while 117 dB minimum common-mode rejection helps preserve small changes in bridge output. The 50 µV maximum offset voltage is particularly relevant when the full-scale sensor signal is also small. Place the instrumentation amplifier close to the bridge, maintain symmetric input routing, and connect the reference input to a quiet low-impedance reference. Verify that the bridge excitation, common-mode voltage, and output swing remain compatible with the ±18 V supply range.

⚡

Industrial Current Shunt Amplification

The INA141PA is appropriate for measuring the voltage developed across a precision shunt in power-conversion, motor-control, and laboratory equipment. A 10 V/V gain is useful for moderate shunt signals, while 100 V/V gain can increase sensitivity for low-current measurements. The low 5 nA maximum input bias current reduces current error through the sensing element, and 117 dB minimum common-mode rejection supports operation when the shunt sits near a switching or bus voltage. The ±40 V input-protection rating is useful for transients around high-current systems. Designers should still place series input resistance as recommended in the datasheet and verify that the shunt common-mode voltage never exceeds the amplifier's operating limits.

💊

Biomedical Signal Acquisition

The INA141PA can be used in low-level biomedical front ends where offset and common-mode errors would otherwise obscure a small differential signal. Its 50 µV maximum offset voltage, 0.5 µV/°C maximum drift, 5 nA maximum input bias current, and 117 dB minimum common-mode rejection are useful for bridge-based pressure, strain, and bioelectrical interfaces. The three-op-amp architecture simplifies implementation compared with a discrete difference amplifier. For patient-connected designs, however, the INA141PA alone does not establish medical safety; isolation, protection leakage, electrode biasing, and regulatory requirements must be addressed by the complete signal chain. Confirm electrode DC offset and common-mode range against the device limits.

🧩

Sensor Interface and Data Acquisition

The INA141PA supports sensor-interface boards that must amplify small differential outputs before digitization. Selectable gains of 10 V/V and 100 V/V provide useful scaling for pressure, temperature, position, and resistive sensors, while 200 kHz bandwidth at 100 V/V supports moderately fast measurements. The 8-PDIP package is convenient for through-hole prototypes and educational or legacy acquisition systems. For best results, place input and reference components near the device, use a low-noise reference at the REF pin, and route high-impedance input traces away from switching nodes. The datasheet's -40 °C to +85 °C operating range supports many industrial environments, but system enclosure temperature and thermal rise must be checked separately.

🔧

Laboratory Measurement Instrumentation

The INA141PA is useful in laboratory instruments that combine a low-level sensor with precision analog measurement. Its low offset voltage and drift reduce measurement uncertainty, and its high common-mode rejection improves signal integrity when the sensor output is referenced to a larger voltage. The selectable 10 V/V or 100 V/V gain permits the same amplifier family to cover several input ranges. The through-hole 8-PDIP format simplifies construction in laboratory fixtures and retrofit boards. Designers should provide a clean reference, observe correct supply bypassing, and avoid placing the input or reference return near high-current switching paths. Because the visible verified data does not provide numeric pricing or every electrical limit, engineers should confirm remaining values in the current manufacturer datasheet.

📱

Battery-Powered Portable Instrument

The INA141PA can be used in portable measurement equipment where low power and precision are both important. Texas Instruments describes the INA141 as a low-power general-purpose instrumentation amplifier, and the device offers selectable gain to reduce the need for multiple analog paths. Its 8-pin plastic DIP package is practical for prototypes, although a surface-mount option may be preferable for a final compact product. Power-system design should account for the actual supply voltage, quiescent current from the manufacturer datasheet, and the power consumed by external gain-setting components. A single positive supply requires careful output and reference-voltage design, whereas dual supplies simplify signal centering. Confirm the complete current budget and battery operating range before selecting the device.

What is the INA141PA instrumentation amplifier?
The INA141PA is a Texas Instruments precision, low-power instrumentation amplifier with selectable gains of 10 V/V or 100 V/V. It is supplied in an 8-pin plastic DIP package and is intended for small-signal differential measurements. According to the Texas Instruments INA141 datasheet, its three-op-amp architecture provides accurate gain, low offset voltage, and common-mode rejection for bridge, biomedical, and industrial sensor circuits.
What are the key specifications of INA141PA that engineers should know?
The INA141PA combines selectable gains of 10 V/V or 100 V/V with 50 µV maximum offset voltage, 0.5 µV/°C maximum drift, 5 nA maximum input bias current, and 117 dB minimum common-mode rejection. Its input protection extends to ±40 V, its supply range is ±18 V, and its bandwidth is 200 kHz at 100 V/V gain. These figures make it suitable for precision differential measurements in an 8-PDIP package.
Where can I download the INA141PA datasheet PDF?
The official INA141PA datasheet is available through Texas Instruments at https://www.ti.com/lit/gpn/INA141, with the product page at https://www.ti.com/product/INA141. The manufacturer identifies the INA141 as a precision, low-power instrumentation amplifier with 10 V/V or 100 V/V gain. The product page also provides ordering, technical documentation, and support information for the device family.
Where can I find the INA141PA pinout?
The INA141PA pinout is documented in the manufacturer datasheet, where the device is specified in an 8-pin plastic DIP package. The standard pin functions include the gain-setting resistor, differential inputs, supply terminals, reference input, and output. Use the Texas Instruments INA141 datasheet at https://www.ti.com/lit/gpn/INA141 for the authoritative pin numbering and application information.
What is the operating voltage range of INA141PA?
The INA141PA operates from ±18 V, providing a total supported supply span of 36 V when both rails are considered. According to the Texas Instruments INA141 datasheet, the wide supply range supports precision analog systems using positive and negative rails. Designers should still ensure that input and output voltages remain inside their specified common-mode and output-swing limits.
How much common-mode rejection does the INA141PA provide?
The INA141PA provides a minimum common-mode rejection ratio of 117 dB. This high rejection is valuable when a small differential sensor signal is superimposed on a larger common-mode voltage, such as a bridge output or shunt measurement. According to the Texas Instruments INA141 datasheet, the device is designed to preserve signal accuracy in noisy industrial and measurement environments.
What can replace the INA141PA?
The closest verified same-brand drop-in candidates are INA141P in the same 8-PDIP format and INA131AP-1, which the supplied cross-reference data describes as a complete replacement with consistent terminals and package. Same-family Texas Instruments variants may also fit depending on gain-setting requirements, but engineers should verify the gain resistor topology, reference behavior, supply limits, and input-protection requirements before substitution.
Is INA141PA the same as INA141P?
The INA141PA and INA141P are closely related 8-PDIP orderable variants of the same INA141 device family, but ordering suffixes can identify different package or qualification details. The verified cross-reference result identifies INA141P as an alternative to INA141PA. Before replacing the part, confirm the exact ordering table, temperature range, gain configuration, and lead or package configuration against the current manufacturer datasheet.
INA141PA vs INA131AP-1 - which is better for a precision bridge amplifier?
The INA131AP-1 is identified by the supplied FindIC cross-reference result as a complete replacement for INA141PA, with consistent terminals, package, and functional characteristics. It is therefore a practical drop-in candidate for a precision bridge-amplifier PCB. However, verify the required gain resistor value and confirm that the exact INA131AP-1 gain configuration matches the INA141PA design before production use.
What is the difference between INA141PA and INA141P?
The supplied cross-reference data lists INA141P as a close alternative to INA141PA with the same 8-PDIP package and instrumentation-amplifier category. The visible verified snippets do not provide a complete quantified comparison of offset, bandwidth, or gain-set details. The practical distinction may be an ordering or qualification suffix, so the manufacturer ordering table and datasheet should be checked before selecting one over the other.
When should I choose INA141PA instead of another instrumentation amplifier?
Choose the INA141PA when the design needs a compact, low-power instrumentation amplifier with selectable 10 V/V or 100 V/V gain, 50 µV maximum offset voltage, and 117 dB minimum common-mode rejection. Its 200 kHz bandwidth at 100 V/V gain also makes it useful where gain and measurement speed must coexist. Choose another candidate only when its reference, gain-setting, protection, qualification, or supply behavior better matches the board.
Is INA141PA suitable for biomedical instrumentation?
The INA141PA can be suitable for low-level biomedical instrumentation because it offers 50 µV maximum offset voltage, 0.5 µV/°C maximum drift, 5 nA maximum input bias current, and 117 dB minimum common-mode rejection. These characteristics help preserve small differential signals. Actual medical-system suitability still depends on the complete front-end design, isolation requirements, leakage specifications, and applicable regulatory validation.
Where to buy INA141PA online?
The INA141PA can be purchased from Texas Instruments and authorized distributors such as DigiKey, with the verified DigiKey listing identified as an 8-PDIP, one-circuit instrumentation amplifier. Distributor inventory and unit pricing can change, so use the live manufacturer or distributor listing for current availability. The verified sources provide no numeric price table, so any quoted commercial value must be confirmed directly before ordering.
What is the price of INA141PA?
The current unit price of INA141PA is not available in the supplied verified data, so no numeric price can be stated reliably as of 2026-10-30. DigiKey and Mouser search results indicate that purchase and pricing information is available through authorized distributors. Check the live INA141PA distributor listing for the quantity-1 price, stock, and volume-break pricing before issuing a purchase order.
What is the lead time and stock status for INA141PA?
The verified DigiKey snippet states that the INA141PA ships today, which indicates distributor availability at the time of retrieval, but it does not provide a numeric manufacturer lead time. Stock status can change without notice. For a production commitment, confirm current quantity, factory lead time, and authorized-channel availability directly with Texas Instruments or the distributor as of 2026-10-30.
What input and thermal design constraints apply to INA141PA?
The INA141PA inputs are protected to ±40 V, while its supported supply range is ±18 V; these are separate limits and must not be confused. Use the protected-input rating as a maximum stress condition rather than a normal operating point. Thermal design should follow the manufacturer operating-temperature specification of -40 °C to +85 °C, with actual dissipation depending on supply voltage, output voltage, load current, and ambient conditions.

Technische Referenzdaten für INA141PA – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose the INA141PA for precision differential measurements requiring selectable 10 V/V or 100 V/V gain, low offset, and strong common-mode rejection in an 8-PDIP package. Choose INA131AP-1 when the supplied cross-reference evidence supports a complete replacement for an existing board, but confirm the exact gain configuration. INA141P is the closest orderable family alternative when its ordering and qualification details fit the design. Consider INA126P, INA128P, or INA129P only when their gain-setting method and electrical limits are confirmed from current datasheets. For a new design, prioritize the INA141PA when its fixed gain selections, 200 kHz bandwidth at 100 V/V, and 117 dB minimum common-mode rejection meet the measurement requirements. Avoid substitution if the board requires an absolute gain reference, specific reference behavior, or exact qualification status that has not been verified.

Vergleich mit Alternativen

Parameter Dieses Produkt INA141P INA131AP-1 INA126P INA128P INA129P
Package 8-PDIP 8-PDIP - same 8-PDIP - same 8-PDIP - same 8-PDIP - same 8-PDIP - same
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Product Type Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier

Wichtigste Unterscheidungsmerkmale

  • Verified same-family 8-PDIP substitution path (vs. INA131AP-1)
  • High-gain operation retains useful bandwidth (vs. INA141P)
  • Precision offset performance for differential sensors (vs. INA131AP-1)

Designhinweise

Do not confuse the ±40 V input-protection rating with the ±18 V normal supply range. The protected input rating is a maximum stress condition, not permission to operate the input above the specified common-mode range. Check the INA141 datasheet for the exact input and output limits under each supply condition, and ensure that external transients are controlled before they reach the amplifier.

Route the differential inputs as a compact, symmetrical pair and keep them away from switching nodes, relay contacts, and high-current return paths. The REF connection should be driven from a low-impedance, low-noise source, because reference noise can appear directly at the output. Use the gain-setting resistor exactly as specified by the manufacturer and avoid long exposed input traces that can increase leakage and noise pickup.

Decouple each supply rail close to the device and follow the manufacturer-recommended capacitor network. The INA141PA supports ±18 V supplies, but its usable output range still depends on the selected rail voltages and the reference voltage. In single-supply operation, verify output-headroom limits and choose the REF voltage carefully so the measured signal remains within the linear output range.

Compliance-Informationen

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Bleifrei
Unknown
Halogenfrei
Unknown
Konfliktmineralien
Unknown

The supplied verified snippets do not explicitly state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status.

Daten verifiziert am: 2026-10-30 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

INA141PA INA141PA datasheet PDF Texas Instruments INA141PA INA141PA 8-PDIP instrumentation amplifier INA141PA gain 10 100 V/V INA141PA common mode rejection 117 dB INA141PA bridge sensor amplifier INA141PA current shunt measurement INA141PA vs INA131AP-1 INA141PA drop-in replacement buy INA141PA online INA141PA price and stock where to find INA141PA pinout what can replace INA141PA INA141PA biomedical instrumentation

Verwandte Bauteile & Begriffe

Texas Instruments INA141PA INA141P INA131AP-1 INA126P INA128P INA129P precision instrumentation amplifier three-op-amp instrumentation amplifier current-feedback input circuitry differential signal common-mode rejection ratio offset voltage offset drift input bias current gain-setting resistor 8-pin plastic DIP DIP family through-hole package bridge sensor current shunt biomedical instrumentation sensor interface power management IC semiconductor
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen