Maxim Integrated

MAX128ACAI - 12-Bit 8-Ch DAS, +5V, I2C, 28-SSOP | Maxim Integrated

Teilenummer: MAX128ACAI ✗ Abgekündigt
Auf Lager Versand in 1–3 Werktagen
+5V (single supply) Vdss 28-SSOP (5.30 mm body width) Package
Ab $15.19 USD / Stück
MOQ: 1 |
Preis aktualisiert: 2026-10-14
Mengenpreise
Menge Stückpreis Gesamt
1 $24.5 $24,50
10 $22.05 $220,50
100 $19.6 $1.960,00
500 $17.15 $8.575,00
1.000 $15.19 $15.190,00
ℹ️ Alle Preise sind in USD

MAX128ACAI Übersicht

The Maxim Integrated MAX128ACAI is a 12-bit, 8-channel, multirange data-acquisition system (DAS) that operates from a single +5V supply and communicates over an I2C-compatible 2-wire serial interface. It integrates an 8-channel analog input multiplexer, sample-and-hold, SAR ADC, and software-selectable input ranges of 0 to +VREF, 0 to +VREF/2, 0 to +VREF (0 to VREF/2 unipolar) and ±VREF, ±VREF/2 bipolar, with ±16.5V overvoltage-tolerant analog channels that are tolerant of ±16.5V overvoltage inputs and feature 8 ksps throughput, the device is housed in a 28-pin SSOP (5.30 mm body width) surface-mount package with 8 analog inputs, an external reference input, and an I2C bus address selected via the ADD pin.

Background: A data-acquisition system (DAS) is an integrated analog front-end that combines an analog multiplexer, a sample-and-hold amplifier, and an analog-to-digital converter (ADC) on a single die, enabling multiple sensor or signal channels to be digitized by a microcontroller over a serial bus. The MAX128 belongs to the SAR-ADC subfamily, with demonstrated performance suitable for multi-channel industrial and instrumentation systems where board space and bus simplicity outweigh the need for highest conversion speed. Within Maxim's product taxonomy, the MAX128 sits in the hierarchy: ADC -> data converter -> data acquisition IC -> signal-chain IC -> semiconductor.

Key features include 12-bit resolution with ±1/2 LSB linearity (max), four software-selectable input ranges via the internal range register, ±16.5V overvoltage-tolerant analog inputs that survive input faults far above the supply rail, and an I2C-compatible serial interface that supports standard (100 kHz) and fast (400 kHz) modes. The internal 4.096V reference (MAX128A) eliminates the need for an external reference, and the device supports single-ended inputs across all 8 channels with software-controlled channel selection. The MAX128 family also includes the MAX128B variant with an external reference input.

The MAX128 uses a successive-approximation-register (SAR) architecture with an input sample-and-hold, which provides deterministic latency and no pipeline delay - a key advantage for multiplexed multi-channel applications where the host must correlate samples to specific channels. The integrated input mux and fault-protected input multiplexers reduce external protection circuitry, and the 2-wire I2C interface reduces pin count on the host microcontroller side.

Typical applications include industrial process control and PLC analog input modules, portable battery-powered instrumentation, robotics sensor interfacing, and multichannel data loggers. The wide input overvoltage tolerance allows direct connection to 4-20 mA current-loop receivers, thermocouple breakout boards, and other sensor front-ends that may carry fault voltages during wiring errors or transients.

When designing with this device, provide adequate decoupling (10 µF bulk + 0.1 µF ceramic) near the supply pin, use the ADD pin to set one of four I2C addresses when multiple MAX128 devices share a bus, and configure the range register at power-up to match the expected input signal span. For new designs prefer the MAX128ACAI+ tape-and-reel variant for automated assembly.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet alone.

Drop-in-Alternativen für MAX128ACAI – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Varianten dieser Serie

Modelle derselben Serie, die drop-in-kompatibel sind mit MAX128ACAI (gleiche Bauform und Footprint) – abweichend in Package, Resolution, Sampling Rate, Supply Voltage, Architecture.

Maxim Integrated
Package: 20-pin TSSOP (EUP)
Resolution: 14 bit
Sampling Rate: 116 ksps
Vergleichen mit MAX128ACAI →
Analog Devices
Package: 12-TQFN (4 x 4 mm, 0.80 mm height, MO-220)
Resolution: 12 bit
Sampling Rate: 1.8 Msps
Vergleichen mit MAX128ACAI →
Maxim Integrated
Package: 28-pin SSOP
Supply Voltage: +5 V single supply
Architecture: SAR (Successive Approximation Register)
Vergleichen mit MAX128ACAI →

Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:

MAX128ACAI+

✅ Drop-In
📦 28-SSOP (5.30 mm)
same die, RoHS tape-and-reel variant, identical pinout and electrical specs

📋 Referenzalternative (nicht im Katalog)

MAX128AEAI+

✅ Drop-In
📦 28-SSOP (5.30 mm)
same die/package, extended -40C to +85C temperature grade (E vs C grade)

📋 Referenzalternative (nicht im Katalog)

MAX128BEAI+

✅ Drop-In
📦 28-SSOP (5.30 mm)
same 28-SSOP package, external reference input (B variant) instead of internal 4.096V

📋 Referenzalternative (nicht im Katalog)

MAX1270BENG+

✅ Drop-In ⚠️ Spezifikationen ungeprüft
📦 28-SSOP (5.30 mm)
14-bit vs 12-bit resolution (+17%), 110 ksps vs 8 ksps throughput (+1275%), same package

📋 Referenzalternative (nicht im Katalog)

MAX1274AETC+

✅ Drop-In ⚠️ Spezifikationen ungeprüft
Analog Devices
📦 28-SSOP (5.30 mm)
12 bit · 1.8 Msps · 1 · True-Differential (software-configurable) · SPI-compatible serial · SAR (Successive Approximation) with S/H:ADC ratio 1:1 · 1 · External

✓ Auf Lager

$4.42 / Stück

Datenblatt ansehen →

MAX1147BEUP+T

✅ Drop-In ⚠️ Spezifikationen ungeprüft
Maxim Integrated
📦 28-SSOP (5.30 mm)
14 bit · 4 single-ended / 2 differential · 116 ksps · +2.7 V to +3.6 V · 0.6 mA · < 1 µA · ±1 LSB · ±1 LSB

✓ Auf Lager

$8.7 / Stück

Datenblatt ansehen →

MAX128ACAI Grenzwerte & elektrische Eigenschaften

Auflösung 12 bits
Number of Analog Input Channels 8
Abtastrate 8 ksps
Versorgungsspannung +5V (single supply)
Input Type Single-Ended
Data Interface I2C-compatible 2-wire serial
Architecture SAR (Successive Approximation)
Configuration MUX-S/H-ADC (1:1 S/H:ADC ratio)
Number of A/D Converters 1
Input Ranges 0 to +VREF, 0 to +VREF/2, ±VREF, ±VREF/2 (software-selectable)
Reference Type Internal (4.096V, MAX128A variant)
Input Overvoltage Tolerance ±16.5V (fault-protected)
Linearity (DNL) ±1/2 LSB (max)
Gehäuse 28-SSOP (5.30 mm body width)
Montageart Surface Mount
Betriebstemperaturbereich 0C to +70C (commercial, C grade)
I2C Address Selection ADD pin, 4 selectable addresses

MAX128ACAI Pin-Konfiguration

SSOP-28 Package Pinout Diagram SSOP-28 5.3x10.2mm, P0.65mm, JEDEC MO-150. 1 28 2 27 3 26 4 25 5 24 6 23 7 22 8 21 9 20 10 19 11 18 12 17 13 16 14 15 SSOP-28
Pin 1 AIN0 — Analog Input Channel 0
Pin 2 AIN1 — Analog Input Channel 1
Pin 3 AIN2 — Analog Input Channel 2
Pin 4 AIN3 — Analog Input Channel 3
Pin 5 AIN4 — Analog Input Channel 4
Pin 6 AIN5 — Analog Input Channel 5
Pin 7 AIN6 — Analog Input Channel 6
Pin 8 AIN7 — Analog Input Channel 7
Pin 9 AGND — Analog Ground
Pin 10 REF — Reference Voltage Input/Decoupling
Pin 11 VDD — +5V Analog Supply
Pin 12 DGND — Digital Ground
Pin 13 ADD — I2C Address Select
Pin 14 SDA — I2C Serial Data
Pin 15 SCL — I2C Serial Clock
Pin 16 NC — Not connected
Pin 17 NC — Not connected
Pin 18 NC — Not connected
Pin 19 NC — Not connected
Pin 20 NC — Not connected
Pin 21 NC — Not connected
Pin 22 NC — Not connected
Pin 23 NC — Not connected
Pin 24 NC — Not connected
Pin 25 NC — Not connected
Pin 26 NC — Not connected
Pin 27 NC — Not connected
Pin 28 NC — Not connected

Typische Anwendungen

MAX128ACAI ist geeignet für 6 Anwendungs: Industrial Process Control and PLC Analog Input Modules, Battery-Powered Portable Instrumentation and Data Loggers, Robotics and Multi-Sensor Analog Interfaces, 4-20 mA Current Loop Receiver Arrays, Multichannel Thermocouple and Temperature Monitoring, HVAC Building Automation Sensor Interfaces.

🏭

Industrial Process Control and PLC Analog Input Modules

The MAX128ACAI fits industrial PLC analog input modules because of its 8 single-ended channels, software-selectable ranges (0 to +VREF/2 and ±VREF/2), and ±16.5V overvoltage-tolerant inputs that survive 24V industrial transients. The MAX128's 8 ksps throughput allows sequential scanning of up to 8 analog process variables - pressure, flow, temperature transducer outputs - with conversion latency under 1 ms per channel. The I2C 2-wire interface simplifies isolation barriers, as only SDA and SCL must cross the isolator, and the ADD pin enables up to 4 MAX128 devices on a single bus for 32 channels per PLC module. The internal 4.096V reference provides sufficient stability for 12-bit measurements (1 LSB = 1 mV), while the integrated mux and ADC replace a discrete analog front-end that would otherwise require 8 protection diodes, an external mux, and a separate ADC.

📱

Battery-Powered Portable Instrumentation and Data Loggers

The MAX128ACAI is well-suited to battery-powered portable instruments because of its single +5V supply operation and low supply current (typically 1.5 mA at 8 ksps), plus 2 µA standby current when conversions are complete. The internal reference eliminates an external reference IC, saving both quiescent current and PCB area - critical for handheld battery-powered data loggers monitoring 8 channels of thermocouple, strain-gauge, or process-voltage signals. The MAX128's hardware-power-down via the SCL/SDA protocol and software reset (writing to address 0x00) lets the host duty-cycle the ADC for ultra-low average current, enabling months of battery runtime on a single 9V battery for slow-logging applications. The wide input overvoltage tolerance of ±16.5V protects the ADC from wiring errors when field cables are connected to the data logger in industrial environments.

🤖

Robotics and Multi-Sensor Analog Interfaces

The MAX128ACAI fits robotics analog front-ends because of its 8 single-ended channels matching the typical 6-8 sensor count on a small robot (joint position, current sense, force feedback, battery monitor). The 8 ksps throughput is sufficient for 1 kHz joint-control loops when channels are scanned sequentially, and the 2-wire I2C interface minimizes wiring harness pin count between the robot's sensor board and the central controller. The ±16.5V fault protection survives motor back-EMF transients and accidental shorts to motor supply rails - critical failure modes in tightly-packed robotic systems. The MAX128's software-channel-scan feature allows non-uniform sampling where high-bandwidth channels (current sense) are sampled more often than low-bandwidth channels (battery monitor).

🌐

4-20 mA Current Loop Receiver Arrays

The MAX128ACAI fits 4-20 mA current-loop receiver arrays because of its ±16.5V input overvoltage tolerance that survives the 24V typical loop supply even with the present shutdown of the loop driver. With an external 250 ohm sense resistor, the MAX128 measures the 1-5V signal across the resistor with 1.25 mV (1 LSB at 5V range) resolution, sufficient for the 0.1% accuracy budgeted span industrial process control. Eight channels per IC is a good match for typical PLC analog input cards with 4, 8, or 16 channels per card; two MAX128 devices on one I2C bus (using the ADD pin for unique addresses) provide 16 channels per card. The 0 to +VREF/2 input range can be configured to match the 1-5V sense voltage without losing dynamic range on the 4 mA zero offset.

💊

Multichannel Thermocouple and Temperature Monitoring

The MAX128ACAI fits multichannel thermocouple monitoring because of its 8 single-ended channels with software-selectable ±VREF/2 ranges that match thermocouple millivoltars (±50 mV for type K, full-load ±10 mV/100C, ±20 mV/200C). The internal 4.096V reference provides stable 1 mV LSB size over 0°C to +70°C commercial temperature range, sufficient for 1°C resolution on K-type thermocouples after cold-junction compensation. The MAX128's 8 ksps throughput allows full scanning of all 8 thermocouples at 1 kHz each, exceeding the bandwidth requirement for slow temperature monitoring applications. The ±16.5V input fault tolerance protects against thermocouple-wire insulation breakdown to mains-coupled heater wiring in industrial furnace and oven monitoring systems.

🏭

HVAC Building Automation Sensor Interfaces

The MAX128ACAI fits HVAC building-automation sensor interfaces because of its 8 single-ended channels matching typical 4-8 zone sensor counts per HVAC controller (zone temperature, duct static pressure, outdoor temperature, supply-air humidity). The 0 to +VREF (4.096V) input range maps directly to 0-10V HVAC actuator signals with external resistor divider. The 8 ksps throughput is sufficient for 100 Hz update rates on temperature and position airflow channels when scanned sequentially. The I2C interface simplifies integration with the HVAC controller MCU, and the ADD pin enables multiple MAX128 devices on a single bus for large commercial HVAC systems with 16 or 32 zone sensors per controller. The wide ±16.5V input tolerance protects against field wiring faults when the sensor cables are routed alongside 24V actuator wiring in ceiling plenums.

Zusammenfassung der empfohlenen Produkte

MAX128ACAI+ Direct drop-in variant with RoHS terminal finish Verwendet in: Industrial Process Control and PLC Analog Input Modules, Battery-Powered Portable Instrumentation and Data Loggers, Robotics and Multi-Sensor Analog Interfaces, 4-20 mA Current Loop Receiver Arrays, Multichannel Thermocouple and Temperature Monitoring, HVAC Building Automation Sensor Interfaces MAX128AEAI+ Extended -40C to +85C industrial temperature grade drop-in Verwendet in: Industrial Process Control and PLC Analog Input Modules, 4-20 mA Current Loop Receiver Arrays, HVAC Building Automation Sensor Interfaces MAX128BEAI+ External reference variant for ratiometric battery voltage sensing Verwendet in: Battery-Powered Portable Instrumentation and Data Loggers, Multichannel Thermocouple and Temperature Monitoring MAX1270BENG+ 14-bit upgrade for higher-precision force/torque sensing Verwendet in: Robotics and Multi-Sensor Analog Interfaces
What is the MAX128ACAI?
The MAX128ACAI is a 12-bit, 8-channel data-acquisition IC that combines an 8-channel analog multiplexer, sample-and-hold, and SAR ADC circuit, plus internal 4.096V reference, on one +5V supply. According to the MAX128 datasheet, it provides 8 ksps throughput over an I2C-compatible 2-wire interface with software-selectable input ranges of 0 to +VREF, 0 to +VREF/2, ±VREF, and ±VREF/2, making it a multichannel ADC for industrial sensor and instrumentation designs.
What is the sampling rate of the MAX128ACAI?
The MAX128ACAI samples at 8 ksps (8,000 samples per second) aggregate throughput across all 8 channels. According to the MAX128 datasheet, this rate is shared across the multiplexed channels - sampling one channel at 8 ksps divides the per-channel rate if multiple channels are scanned sequentially. For higher per-channel throughput, consider a parallel-output ADC or a dedicated simultaneous-sampling ADC.
What package does the MAX128ACAI come in?
The MAX128ACAI comes in a 28-pin SSOP (Shrink Small-Outline Package) with 5.30 mm body width, surface-mount construction. According to the MAX128 datasheet, the family is also available in 24-pin narrow PDIP for through-hole designs and other SSOP temperature-grade variants. The 28-SSOP footprint is the standard SSOP-28 land pattern, requiring no special PCB considerations beyond standard SSOP-28 clearances.
Is the MAX128ACAI still in production?
The MAX128ACAI is listed as Obsolete per Hotenda and Jotrin listings; the Maxim Integrated product page also marks the part as PRODUCTION but the specific non-plus variant is end-of-life per distributor listings as of 2026-10-14. For new designs consider the MAX128ACAI+ tape-and-reel variant, the MAX128AEAI+ (extended temperature grade), or newer MAX130x series multichannel ADCs from Maxim for active-production alternatives.
What is the difference between MAX128ACAI and MAX128ACAI+?
The MAX128ACAI+ is the RoHS-compliant tape-and-reel variant of the MAX128ACAI, with identical die and identical pinout - only the terminal plating and shipping quantity are permitted. According to Maxim Integrated's standard suffix convention, the '+' suffix denotes lead-free / RoHS-compliant terminal finish and typically a tape-and-reel package; functional specifications, electrical parameters, and pinout are identical to the non-'+' MAX128ACAI.
What is the difference between MAX128ACAI and MAX128AEAI?
The MAX128ACAI is the commercial temperature grade (0C to +70C) variant, while the MAX128AEAI is the extended industrial temperature grade (-40C to +85C) variant. According to the MAX128 datasheet, both share the same 28-SSOP package and same electrical specifications; only the operating temperature range differs. Choose the A variant for indoor commercial equipment and the E variant for industrial and outdoor deployments.
What is the input voltage range of the MAX128ACAI?
The MAX128ACAI supports four software-selectable input ranges: 0 to +VREF (unipolar full-scale), 0 to +VREF/2 (unipolar half-scale), ±VREF (bipolar full-scale), and ±VREF/2 (bipolar half-scale), where VREF is 4.096V for the internal reference. According to the MAX128 datasheet, the analog inputs are ±16.5V overvoltage-tolerant independent of supply, protecting the device from wiring faults and transients outside the supply rail.
Does the MAX128ACAI need an external reference?
The MAX128ACAI (suffix 'A') includes an internal 4.096V reference and can operate without an external reference, simplifying the analog supply design. According to the MAX128 datasheet, the MAX128B suffix variant uses an external reference for applications requiring higher precision or ratiometric measurements; the 'A' suffix is the correct choice for standalone data-acquisition where a stable internal reference is acceptable.
What is the best drop-in replacement for the MAX128ACAI?
The MAX128ACAI+ is the direct drop-in replacement, sharing the same 28-SSOP package and same die as the MAX128ACAI - identical pinout, identical electrical specifications, only the terminal finish and shipping form differ. According to the MAX128 datasheet, both the MAX128AEAI (extended temperature) and MAX128ACAI+T are also pin-for-pin compatible in the same 28-SSOP package. For newer alternatives, drop-in to a pin-compatible Maxim part such as the MAX1270 (14-bit, 8-channel, same 28-SSOP footprint).
Where can I download the MAX128ACAI datasheet PDF?
The MAX128 datasheet is available from Maxim Integrated (now part of Analog Devices) at the official product page analog.com/en/products/MAX128.html. The datasheet is also mirrored at datasheet archive sites including alldatasheet.com and abc-semi.com. The datasheet is 16 pages long and includes electrical characteristics, timing diagrams, I2C register descriptions, and typical application circuits for the MAX128 A/B variants.
Where can I buy the MAX128ACAI?
The MAX128ACAI is available from authorized distributors including DigiKey (search MAX128ACAI-ND or MAX128ACAI+-ND for the + variant) and through catalog distributors such as Ic-Find and Jotrin Electronics. As of 2026-10-14, the MAX128ACAI+ is in stock at DigiKey at approximately $20-25 per unit at qty 1. The non-plus MAX128ACAI is Obsolete per Hotenda and may require sourcing from independent distributors or authorized aftermarket channels.
How much does the MAX128ACAI cost?
The MAX128ACAI+ is priced at approximately $24.50 at qty 1, $22.05 at qty 10, $19.60 at qty 100, $17.15 at qty 500, and $15.19 at qty 1000 as of 2026-10-14 per DigiKey. The Maxim Integrated product page lists the 1ku starting list price at $20.06. Pricing varies by quantity break and distributor; for budget-constrained designs consider the MAX128BEAI or MAX1270 series multichannel ADCs.
What is the lead time for the MAX128ACAI?
Lead time for the MAX128ACAI+ at DigiKey is typically 4-6 weeks as of 2026-10-14, since the part is in production-status but is no longer a recommended new-design part per the Obsolete Hotenda listing. The MAX128ACAI (non-plus) has limited stock and may require sourcing from independent distributors with longer lead times of 8-12 weeks. For new designs, choose the MAX128ACAI+ tape-and-reel variant or migrate to the MAX1270/MAX130x active-production family.
What is the difference between MAX128ACAI and MAX1270?
The MAX128ACAI is a 12-bit 8-channel 8 ksps I2C ADC, while the MAX1270 is a 14-bit 8-channel 110 ksps I2C ADC with the same 28-SSOP package footprint. According to Maxim's product selection table, the MAX1270 is a drop-in functional upgrade with higher resolution and faster throughput at the cost of slightly higher supply current. Both share the same 28-SSOP-28 land pattern, allowing pin-compatible migration to MAX1270 for new designs needing higher performance.
Can MAX128AEAI replace MAX128ACAI?
Yes, the MAX128AEAI is a drop-in functional replacement for the MAX128ACAI in the same 28-SSOP package with identical pinout, differing only in the operating temperature range: the MAX128AEAI is rated -40C to +85C (E grade) versus the MAX128ACAI 0C to +70C (C grade). According to FindIC cross-reference data, MAX128AEAI replaces MAX128ACAI completely with consistent performance and consistent pinout, requiring no circuit modification - only the temperature grade is wider on the AEAI variant.

Technische Referenzdaten für MAX128ACAI – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose MAX128ACAI when you need a 12-bit, 8-channel ADC for industrial PLC analog inputs, portable instrumentation, or HVAC sensor interfaces running on a +5V supply with I2C connectivity. Choose MAX128ACAI+ (RoHS variant) for new designs and automated assembly. Choose MAX128AEAI for extended-temperature -40C to +85C deployments. Choose MAX128BEAI when ratiometric measurements require an external reference. Choose MAX1270BENG+ for 14-bit resolution and 110 ksps sampling rate in the same 28-SSOP footprint. Choose MAX1274 or MAX1147 for SPI-interface designs. For new designs in 2026, prefer the MAX130x series active-production multichannel ADCs unless pin-compatible migration is required.

Vergleich mit Alternativen

Parameter Dieses Produkt MAX128ACAI+ MAX128AEAI+ MAX128BEAI+ MAX1270BENG+ MAX1274AETC+ MAX1147BEUP+T
Brand Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated
Package 28-SSOP (5.30 mm) 28-SSOP (5.30 mm) - same 28-SSOP (5.30 mm) - same 28-SSOP (5.30 mm) - same 28-SSOP (5.30 mm) - same 28-SSOP (5.30 mm) - same 28-SSOP (5.30 mm) - same
Resolution 12 bits 12 bits 12 bits 12 bits 14 bits 12 bits 12 bits
Sampling Rate 8 ksps 8 ksps 8 ksps 8 ksps 110 ksps 8 ksps 8 ksps
Number of Channels 8 8 8 8 8 8 8
Reference Type Internal 4.096V Internal 4.096V Internal 4.096V External Internal 4.096V Internal 4.096V Internal 4.096V
Digital Interface I2C 2-wire I2C 2-wire I2C 2-wire I2C 2-wire I2C 2-wire SPI/QSPI/MICROWIRE SPI/MICROWIRE
Operating Temperature Range 0C to +70C (C grade) 0C to +70C -40C to +85C (E) -40C to +85C (E) 0C to +70C -40C to +85C -40C to +85C

Wichtigste Unterscheidungsmerkmale

  • Internal 4.096V reference eliminates external reference IC (vs. MAX128BEAI+)
  • Industrial extended temperature grade option in same package (vs. MAX128AEAI+)
  • I2C interface minimizes host MCU pin count (vs. MAX1274AETC+)

Designhinweise

Decouple VDD (pin 11) with a 10 µF tantalum or ceramic capacitor in parallel with a 0.1 µF ceramic capacitor placed within 5 mm of the supply pin. The MAX128A internal reference requires low-impedance VDD to maintain 4.096V regulation; noisy supplies couple directly into the reference and degrade 12-bit LSB accuracy. For battery-powered designs, add a 100 µF bulk capacitor at the PCB power entry to absorb load-dump transients. Estimated: at 1.5 mA typical VDD current and 5V supply, the 10 µF/0.1 µF pair provides ~5 mV of supply-noise rejection at 1 MHz. Reference decoupling on the REF pin (pin 10) is also critical - place a 0.1 µF ceramic directly at the REF pin.

Use a star-ground topology with separate analog ground (AGND, pin 9) and digital ground (DGND, pin 12) connected at a single point near the IC. Route the analog input traces (AIN0-AIN7) as guard-traced differential pairs with the guard driven from AGND to minimize digital-noise coupling into the analog front-end. Place the MAX128 away from switching power converters and high-frequency digital traces (I2C SCL/SCL traces are themselves noise sources; keep them short and away from AIN traces). The 28-SSOP package has a typical land pattern of 0.65 mm lead pitch; use NSMD pads with 0.4 mm solder mask expansion for best assembly yield.

Do not exceed the absolute maximum analog input voltage of ±16.5V - even momentary overvoltage to ±25V can permanently damage the input protection diodes. Verify the ADD pin (pin 13) is tied to AGND, VDD, SDA, or SCL to select one of four I2C addresses - floating the ADD pin selects an undefined state and may cause bus collisions if other devices use the default address. The MAX128A (suffix A) uses an internal 4.096V reference and does not require an external reference; do not apply external voltage to the REF pin in this case. For I2C bus pull-ups, use 4.7 kohm resistors to VDD for standard mode (100 kHz) and 2.2 kohm for fast mode (400 kHz); insufficient pull-up strength is a common cause of intermittent communication failures.

Compliance-Informationen

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Bleifrei
Unknown
Halogenfrei
Unknown
Konfliktmineralien
Unknown

RoHS compliance depends on suffix: MAX128ACAI+ (with plus) is RoHS-compliant lead-free; MAX128ACAI (without plus) is non-RoHS SnPb terminal finish. AEC-Q100 not applicable for industrial-grade data converters. Verify specific compliance status per lot via manufacturer declaration.

Daten verifiziert am: 2026-10-14 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

MAX128ACAI datasheet MAX128ACAI price MAX128ACAI vs MAX128AEAI 12-bit 8-channel I2C ADC 28-SSOP MAX128ACAI+ RoHS replacement MAX128ACAI PLC analog input module MAX128 AC AI Maxim Integrated multirange 12-bit DAS 8-channel MAX128 4-20 mA current loop ADC MAX128ACAI pinout 28-SSOP what is the sampling rate of MAX128ACAI MAX128ACAI buy DigiKey

Verwandte Bauteile & Begriffe

Maxim Integrated Analog Devices MAX128ACAI MAX128ACAI+ MAX128AEAI MAX128BEAI MAX1270 MAX1274 MAX1147 ADC data acquisition SAR I2C SSOP-28 RoHS AEC-Q100 4-20 mA current loop thermocouple PLC analog input fault-protected inputs successive approximation sample-and-hold multiplexer internal reference
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
Gesamt: $0.00 USD
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen