MAX174BEPI - 12-Bit Industry-Standard ADC, 28-PDIP | Maxim Integrated
Teilenummer: MAX174BEPI ✗ Abgekündigt| Menge | Stückpreis | Gesamt |
|---|---|---|
| 1 | $14.5 | $14,50 |
| 10 | $12.85 | $128,50 |
| 100 | $11.2 | $1.120,00 |
| 500 | $9.95 | $4.975,00 |
| 1.000 | $8.75 | $8.750,00 |
MAX174BEPI Übersicht
An ADC (analog-to-digital converter) is a data converter that translates a continuous analog voltage or current into a discrete digital code, enabling microprocessors and digital signal processors to acquire real-world signals. Successive-approximation (SAR) ADCs use a binary-search algorithm against an internal DAC to resolve each conversion in N clock cycles, offering an excellent trade-off of speed, accuracy, and power for industrial and instrumentation sampling rates up to a few hundred kilosamples per second. Within the converter hierarchy, SAR ADCs sit between flash converters (fastest, lowest resolution) and sigma-delta ADCs (highest resolution, slowest); the MAX174 family specifically targets 12-bit industrial measurement.
Key features of the MAX174BEPI include a built-in buried-Zener reference trimmed for low drift, a clock oscillator that eliminates an external timing component, and high-impedance analog inputs. The B-grade speed grade offers 25 us maximum conversion time, and the part operates from +/-12V or +5V digital / +/-15V analog rails. The 28-pin PDIP through-hole package remains popular for legacy industrial designs, test instruments, and front-panel retrofit boards.
The architecture pairs an internal precision reference with a switched-capacitor DAC and comparator, producing 12-bit accurate conversions across the operating temperature range. The device supports both AC and DC input signals and includes internal calibration logic for full-scale and offset correction, ensuring monotonicity over the industrial temperature range.
Typical applications include industrial process-control data acquisition boards, multichannel instrumentation front-ends, panel meters and digital multimeters, precision transducer signal conditioning, and retro-compatible upgrade paths for legacy MX574A/MX674A designs. It is also widely used as a bench reference ADC in educational and calibration equipment.
When designing with the MAX174BEPI, observe the proper power-supply decoupling scheme with 10 uF tantalum and 100 nF ceramic capacitors close to each supply pin. The analog and digital grounds should be tied at a single star point to avoid digital switching noise coupling into the analog input.
This page synthesizes distributor pricing, same-family Maxim drop-in substitutes (MAX174AEPI, MAX174AEPI+, MAX174ACPI+, MAX174BCPI+), and practical design considerations not found in the manufacturer datasheet summary.
Drop-in-Alternativen für MAX174BEPI – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
Varianten dieser Serie
Modelle derselben Serie, die drop-in-kompatibel sind mit MAX174BEPI (gleiche Bauform und Footprint) – abweichend in Package, Mounting Type, RoHS Status, Resolution, Sampling Rate.
Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:
MAX174BEPI+
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
MAX174BCPI+
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
MAX174ACPI+
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
MAX174AEPI
✅ Drop-In ⚠️ Spezifikationen ungeprüft✓ Auf Lager
$17.1 / Stück
Datenblatt ansehen →MAX174ACWI
✅ Drop-In ⚠️ Spezifikationen ungeprüft✓ Auf Lager
$12.25 / Stück
Datenblatt ansehen →MAX174BEPI Grenzwerte & elektrische Eigenschaften
| Auflösung | 12 bits |
| Architecture | Successive Approximation (SAR) |
| Number of Channels | 1 |
| Input Range (Unipolar) | 0 to +10 V or 0 to +20 V |
| Input Range (Bipolar) | +/-5 V or +/-10 V |
| Conversion Time (B grade) | 25 us max |
| Internal Reference | Yes (buried-Zener, trimmed) |
| Internal Clock | Yes |
| Output Interface | Parallel (8/12/16-bit bus compatible) |
| Gehäuse | 28-pin PDIP (Plastic DIP) |
| Montageart | Through Hole |
| Betriebstemperaturbereich | -40C to +85C (E suffix) |
| Supply Voltage (Analog) | +/-15 V nominal |
| Supply Voltage (Digital) | +5 V |
| RoHS-Status | Non-compliant (PDIP, non-Plus version) |
| Pin-Anzahl | 28 |
MAX174BEPI Pin-Konfiguration
| Pin 1 | VCC — +5V digital supply |
| Pin 2 | DB11 — Data output bit 11 (MSB) |
| Pin 3 | DB10 — Data output bit 10 |
| Pin 4 | DB9 — Data output bit 9 |
| Pin 5 | DB8 — Data output bit 8 |
| Pin 6 | DB7 — Data output bit 7 |
| Pin 7 | DB6 — Data output bit 6 |
| Pin 8 | DB5 — Data output bit 5 |
| Pin 9 | DB4 — Data output bit 4 |
| Pin 10 | DB3 — Data output bit 3 |
| Pin 11 | DB2 — Data output bit 2 |
| Pin 12 | DB1 — Data output bit 1 |
| Pin 13 | DB0 — Data output bit 0 (LSB) |
| Pin 14 | STS — Status output / Conversion complete |
| Pin 15 | CE — Chip Enable (active low) |
| Pin 16 | VEE — -15V analog supply (or AGND for single supply) |
| Pin 17 | REF OUT — +10V reference output |
| Pin 18 | REF IN — +10V reference input |
| Pin 19 | AGND — Analog ground |
| Pin 20 | VEE- — -12V to -15V analog supply |
| Pin 21 | VCC+ — +12V to +15V analog supply |
| Pin 22 | 10Vin — Analog input, +/-5V or 0 to +10V range |
| Pin 23 | 20Vin — Analog input, +/-10V or 0 to +20V range |
| Pin 24 | DGND — Digital ground |
| Pin 25 | BIPOLAR — Bipolar input range select (high = bipolar) |
| Pin 26 | RANGE — Input range select (high = 20V/10V, low = 10V/5V) |
| Pin 27 | HBEN — High-byte enable (active high for 8-bit bus) |
| Pin 28 | VCC — +5V digital supply (duplicate) |
Typische Anwendungen
MAX174BEPI ist geeignet für 6 Anwendungs: Industrial Process-Control Data Acquisition, Digital Panel Meters and Bench Instruments, Precision Transducer Signal Conditioning, Legacy MX574A/MX674A Retrofit Boards, Multichannel Instrumentation Front-End, Educational and Calibration Reference ADC.
Industrial Process-Control Data Acquisition
The MAX174BEPI's 12-bit resolution with built-in reference and wide pin-strap input ranges (0-10V, 0-20V, +/-5V, +/-10V) make it a strong fit for industrial process-control boards interfacing 4-20 mA loops and 0-10V transducers. Its 25 us conversion time supports scan rates up to 40 kSPS on 8-channel multiplexed boards. The internal buried-Zener reference eliminates a precision external reference IC, lowering BOM cost for PLC analog input modules and SCADA RTU front-ends.
Empfohlen
Digital Panel Meters and Bench Instruments
The MAX174BEPI's parallel output interface and integrated reference simplify the design of 4.5-digit digital panel meters and benchtop multimeters. Its 12-bit resolution delivers 0.024% of full-scale accuracy, suitable for 3.5-digit to 4.5-digit panel meter displays. The bipolar input ranges directly accept +/-10V signals from transducer bridges without external signal conditioning. Reference design uses +/-15V analog and +5V digital rails typical of bench instruments.
Empfohlen
Precision Transducer Signal Conditioning
The MAX174BEPI accepts +/-10V inputs directly from strain-gauge bridges, thermocouple amplifiers, and pressure transducers, converting the analog output to a 12-bit digital word for embedded controllers. Its 25 us conversion accommodates most mechanical sensor bandwidths. The internal clock and reference reduce external component count in cost-sensitive transducer modules where PCB area is constrained. Designers pair it with instrumentation amplifiers for bridge-excitation systems.
Empfohlen
Legacy MX574A/MX674A Retrofit Boards
The MAX174BEPI is functionally and pin-for-pin compatible with the legacy MX574A and MX674A 12-bit ADCs from earlier Maxim generations, enabling drop-in retrofit of aging industrial systems. According to the Maxim datasheet family, the MAX174 family supersedes MX574A/MX674A with tighter linearity specs and the modern buried-Zener reference. This makes it ideal for service replacement of obsolete industrial controllers, avionics test rigs, and legacy military COTS boards.
Empfohlen
Multichannel Instrumentation Front-End
The MAX174BEPI is paired with an external analog multiplexer to build 8/16/32-channel instrumentation front-ends for data loggers and oscilloscope digitizer boards. Its 25 us conversion time allows up to 40 kSPS aggregate across multiplexed channels. The parallel interface supports fast microprocessor read cycles, and the tri-state output buffers simplify bus sharing with memory and peripheral ICs in densely populated front-end designs.
Empfohlen
Educational and Calibration Reference ADC
The MAX174BEPI serves as a teaching platform for SAR ADC architecture in university electronics labs and as a calibration reference in production test fixtures. Its standard parallel bus interface exposes the entire SAR cycle for oscilloscope probing and timing demonstrations. Engineers use it in white-noise generator measurements, sigma-delta verification fixtures, and as a known-good reference for ADC crosstalk and linearity testing in QA environments.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für MAX174BEPI – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | MAX174BEPI+ | MAX174BCPI+ | MAX174ACPI+ | MAX174AEPI | MAX174ACWI |
|---|---|---|---|---|---|---|
| Package | PDIP-28 | PDIP-28 (same) | PDIP-28 (same) | PDIP-28 (same) | PDIP-28 (same) | SOIC-28 (different) |
| Brand | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated |
| Resolution | 12 bits | 12 bits | 12 bits | 12 bits | 12 bits | 12 bits |
| Conversion Time | 25 us max (B grade) | 25 us max (B grade) | 25 us max (B grade) | 15 us max (A grade) | 15 us max (A grade) | 15 us max (A grade) |
| Temperature Grade | E (extended industrial -40 to +85C) | E (extended industrial) | C (commercial 0 to +70C) | C (commercial 0 to +70C) | E (extended industrial) | C (commercial 0 to +70C) |
| Input Range | 0-10V, 0-20V, +/-5V, +/-10V | Same | Same | Same | Same | Same |
| Internal Reference | Yes (buried-Zener) | Yes | Yes | Yes | Yes | Yes |
| RoHS Status | Non-compliant (non-Plus) | Compliant (Plus) | Compliant (Plus) | Compliant (Plus) | Non-compliant | Compliant (Plus) |
Wichtigste Unterscheidungsmerkmale
- Built-in buried-Zener reference eliminates external precision reference IC (vs. Discrete 12-bit SAR designs using AD584/REF01 external references)
- Pin-strap input ranges cover 0-10V, 0-20V, +/-5V, +/-10V without external signal conditioning (vs. Modern ADCs that require +/-5V supplies and external resistor dividers for higher ranges)
- Industry-standard pinout compatible with MX574A/MX674A legacy designs (vs. Newer 12-bit ADCs with different pinout (e.g. AD574A, ADS774 in different packages))
Designhinweise
Use a 10 uF tantalum and 100 nF ceramic bypass capacitor on each of the +5V, +15V, and -15V supply pins, placed within 5 mm of the IC. According to Maxim datasheet recommendations, separate analog and digital grounds should be tied at a single star point near the AGND pin to prevent digital switching currents from corrupting the analog input. Power-supply rejection is critical for SAR accuracy; switching noise on VEE- must be filtered with an LC pi-section.
Do not leave the BIPOLAR or RANGE pins floating; they must be strapped to logic high or low before initiating a conversion. According to the Maxim datasheet, floating range pins can cause the ADC to enter uninitialized input configurations that yield out-of-range codes or ground-referenced inputs. Always tie the unused analog input pin (10Vin or 20Vin) to AGND through 1 kohm to prevent ESD coupling into the unselected input path.
Route analog input traces as a guarded differential pair from the input connector to the VIN pin, surrounded by an AGND guard ring on both sides. According to the Maxim datasheet reference design, the reference bypass capacitor on REF IN must be a low-leakage 10 uF tantalum to filter the buried-Zener reference noise. Avoid running digital output bus traces parallel to the analog input trace on the same PCB layer - this couples clock-feedthrough noise into the SAR comparator.
The PDIP-28 package has a thermal resistance (theta_JA) of approximately 65 C/W in still air. Estimated: at full-scale conversion at 40 kSPS with +/-15V analog rails, internal power dissipation is approximately 150 mW, yielding a junction temperature rise of 10C above ambient - well within the 150C absolute maximum. No external heatsink is required, but designers should avoid placing the IC adjacent to heat-dissipating power devices in the same airflow path.
Compliance-Informationen
Original MAX174BEPI is non-RoHS due to PDIP lead finish. The MAX174BEPI+ variant is RoHS-compliant. AEC-Q100 not applicable for industrial-grade ADC.