Maxim Integrated

MAX198BENI - 12-Bit 100kSPS 6-Ch DAS 28-PDIP | Maxim Integrated

Teilenummer: MAX198BENI ✗ Abgekündigt
Auf Lager Versand in 1–3 Werktagen
+5 V single supply Vdss 28-pin PDIP (N) Package
Ab $19.2 USD / Stück
MOQ: 1 |
Preis aktualisiert: 2026-10-14
Mengenpreise
Menge Stückpreis Gesamt
1 $32.4 $32,40
10 $28.95 $289,50
100 $24.5 $2.450,00
500 $21.8 $10.900,00
1.000 $19.2 $19.200,00
ℹ️ Alle Preise sind in USD

MAX198BENI Übersicht

The Maxim Integrated (Analog Devices) MAX198BENI is a 12-bit, 6-channel, multi-range data acquisition system (DAS) with fault-protected inputs and a parallel microprocessor interface, housed in a 28-pin PDIP through-hole package. Operating from a single +5V supply, it delivers 100 ksps throughput, 1/2-LSB linearity, and software-selectable input ranges of 0V to +VREF or 0V to +5V with an internal 4.096V or external reference. The part combines an input multiplexer, track/hold, 12-bit ADC, and channel-selection logic on-chip.

A data acquisition system (DAS) is an integrated mixed-signal IC that aggregates analog multiplexing, sample-and-hold, and ADC conversion into a single chip, sitting between analog sensors and a digital processor within the broader hierarchy of data converters -> ADC/DAC -> signal chain -> mixed-signal ICs -> semiconductors. The MAX198 family was designed for industrial process-control and instrumentation systems requiring robust analog front ends.

Key features of the MAX198BENI include fault-protected input multiplexers that withstand ±16V overvoltages without damage, software-configurable unipolar input ranges (0V to +VREF or 0V to +5V), an on-chip 4.096V reference (5 ppm/°C typical), and a 12-bit parallel interface for fast data throughput. The -B grade provides ±1/2-LSB INL and DNL linearity, while the 100 ksps sampling rate supports most industrial control loops.

The device uses a successive-approximation register (SAR) architecture with an input track-and-hold, allowing accurate acquisition of fast transient signals up to the Nyquist limit of the 100 ksps sample rate. The fault-protected input multiplexer is rated to ±16V, eliminating external protection circuitry in many industrial applications.

Typical applications include industrial process control, multi-channel data logging, PLC analog input modules, and instrumentation front-ends. The wide input range and fault protection make it well-suited for factory-floor environments where sensor signals vary widely and wiring transients are common.

When designing with this part, ensure the analog input signal source impedance stays below the datasheet-specified limit (typically 1 kΩ at 100 ksps) to avoid conversion errors, and place the +5V decoupling capacitor within 10mm of the VDD pin to suppress digital switching noise from coupling into the analog path.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet, providing engineers a single consolidated source for sourcing decisions.

Drop-in-Alternativen für MAX198BENI – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Varianten dieser Serie

Modelle derselben Serie, die drop-in-kompatibel sind mit MAX198BENI (gleiche Bauform und Footprint) – abweichend in Function, Manufacturer, Mounting Type, Package, Supply Voltage.

Maxim Integrated
Function: 6-Channel 12-Bit Multi-Range Data Acquisition System (DAS) ADC
Manufacturer: Maxim Integrated (now Analog Devices)
Mounting Type: Surface Mount
Vergleichen mit MAX198BENI →

Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:

MAX198BCNI+

✅ Drop-In
📦 28-PDIP (N)
same die, same 28-PDIP, RoHS lead-free variant; identical 100 ksps, 12-bit, ±1/2 LSB linearity

📋 Referenzalternative (nicht im Katalog)

MAX198AENI+

✅ Drop-In
📦 28-PDIP (N)
A-grade linearity: ±1 LSB INL vs ±1/2 LSB (B-grade), otherwise pin-compatible 28-PDIP, same 100 ksps, 6 channels

📋 Referenzalternative (nicht im Katalog)

MAX198ACNI+

✅ Drop-In
📦 28-PDIP (N)
A-grade linearity (AC suffix) RoHS lead-free, same 28-PDIP footprint, identical 100 ksps, 12-bit, 6-channel architecture

📋 Referenzalternative (nicht im Katalog)

MAX198BCAI

✅ Drop-In
Maxim Integrated
📦 28-PDIP (N)
Maxim Integrated (now Analog Devices) · MAX198BCAI · 6-Channel 12-Bit Multi-Range Data Acquisition System (DAS) ADC · 12 bit · 100 ksps · 6 · Single +5 V · 0 V to +5 V (software-selectable); 0 V to +VREF

✓ Auf Lager

$16.95 / Stück

Datenblatt ansehen →

MAX198BENI Grenzwerte & elektrische Eigenschaften

Manufacturer Maxim Integrated (Analog Devices Inc.)
Funktion Data Acquisition System (DAS)
Number of Channels 6
Auflösung 12 bit
Abtastrate 100 ksps
Versorgungsspannung +5 V single supply
Linearity (INL/DNL) 1/2 LSB max (B grade)
Input Range 0V to +VREF or 0V to +5V (unipolar)
Internal Reference 4.096 V
Fault-Protected Inputs ±16 V overvoltage
Data Interface 12-bit parallel
Gehäuse 28-pin PDIP (N)
Montageart Through-Hole (DIP)
Betriebstemperatur -40°C to +85°C (industrial)
Architecture SAR with track-and-hold

MAX198BENI Pin-Konfiguration

DIP-28 Package Pinout Diagram DIP-28 28-pin dual inline, 7.62mm pitch, JEDEC MS-001. 1 28 2 27 3 26 4 25 5 24 6 23 7 22 8 21 9 20 10 19 11 18 12 17 13 16 14 15 DIP-28
Pin 1 CH0 — Analog input channel 0
Pin 2 CH1 — Analog input channel 1
Pin 3 CH2 — Analog input channel 2
Pin 4 CH3 — Analog input channel 3
Pin 5 CH4 — Analog input channel 4
Pin 6 CH5 — Analog input channel 5
Pin 7 VDD — +5V analog supply
Pin 8 AGND — Analog ground
Pin 9 REF — Reference voltage input/output
Pin 10 REFADJ — Reference adjust pin
Pin 11 INT — Interrupt output
Pin 12 HBEN — High-byte enable
Pin 13 CS — Chip select (active low)
Pin 14 WR — Write strobe
Pin 15 RD — Read strobe
Pin 16 DGND — Digital ground
Pin 17 D11 — Data bit 11 (MSB)
Pin 18 D10 — Data bit 10
Pin 19 D9 — Data bit 9
Pin 20 D8 — Data bit 8
Pin 21 D7 — Data bit 7
Pin 22 D6 — Data bit 6
Pin 23 D5 — Data bit 5
Pin 24 D4 — Data bit 4
Pin 25 D3 — Data bit 3
Pin 26 D2 — Data bit 2
Pin 27 D1 — Data bit 1
Pin 28 D0 — Data bit 0 (LSB)

Typische Anwendungen

MAX198BENI ist geeignet für 6 Anwendungs: Industrial Process Control & PLC Analog Input Modules, Multi-Channel Data Logging Systems, Medical Patient Monitoring Equipment, HVAC and Building Automation Sensor Interfaces, Automotive Diagnostic and Test Equipment, Instrumentation Front-End for Test & Measurement.

🏭

Industrial Process Control & PLC Analog Input Modules

The MAX198BENI's 6 single-ended input channels, ±16V fault protection, and 100 ksps throughput make it ideal for industrial process control and PLC analog input modules that monitor multiple 4-20mA-loop-derived or 0-10V sensor signals. The MAX198BENI directly interfaces to PLC CPUs via its 12-bit parallel bus, eliminating the need for an external multiplexer or sample/hold. With software-selectable 0V to +VREF or 0V to +5V input ranges, the MAX198BENI accommodates thermocouple, RTD, and pressure transducer signal chains. The integrated 4.096V reference (5 ppm/°C typical) provides the DAC excitation and ADC reference from a single IC, reducing BOM cost in factory-floor systems.

📊

Multi-Channel Data Logging Systems

The MAX198BENI's 12-bit resolution at 100 ksps and 6 input channels suit multi-channel data loggers recording temperature, pressure, humidity, and flow simultaneously from multiple sensors. The MAX198BENI samples at 100 ksps aggregate, which yields approximately 16.6 ksps per channel when time-multiplexed across all 6 inputs - sufficient for most mechanical and thermal data acquisition tasks. The internal track-and-hold captures fast transient signals up to the Nyquist limit, while the parallel microprocessor interface allows a microcontroller or DSP to read conversions in a single bus cycle. The MAX198BENI's NRND status makes long-term sourcing for data logger production runs worth evaluating against the MAX198BCNI+ alternative.

💊

Medical Patient Monitoring Equipment

In medical patient monitoring equipment, the MAX198BENI serves as the analog front-end digitizing ECG, SpO2, temperature, and respiration signals from multiple isolated sensor channels. The MAX198BENI's 12-bit resolution is sufficient for diagnostic-grade vitals capture when paired with external instrumentation amplifiers, while its 6 channels consolidate multiple sensor inputs into a single chip. The MAX198BENI's fault-protected ±16V inputs tolerate defibrillator discharge transients that propagate through patient isolation barriers. Designers targeting FDA-compliant systems should verify the NRND status and consider MAX198BCNI+ for new medical product introductions.

🏗️

HVAC and Building Automation Sensor Interfaces

The MAX198BENI's integrated multiplexer and ±16V fault protection suit HVAC and building automation systems where multiple temperature, pressure, CO2, and humidity sensors share a common ADC. The MAX198BENI handles 6 sensor inputs from a single +5V supply, replacing discrete op-amp + ADC designs. Its unipolar 0V to +5V input range maps directly to common HVAC transducers with 0-5V or 0-10V (with divider) output stages. The MAX198BENI's industrial -40°C to +85°C operating range matches HVAC equipment environmental requirements, and its parallel interface eases connection to BACnet or Modbus gateway controllers.

🚗

Automotive Diagnostic and Test Equipment

The MAX198BENI's 6-channel input multiplexer and wide input range make it suitable for automotive diagnostic equipment that monitors multiple analog sensor outputs simultaneously - including O2 sensor, MAP sensor, MAF sensor, throttle position, and coolant temperature signals. The MAX198BENI samples at 100 ksps aggregate, enough for engine control diagnostic work. Although not AEC-Q100 qualified itself, the MAX198BENI is widely used in off-vehicle bench-top test fixtures and factory-end-of-line testers where automotive temperature and EMI environments are simulated. Designers needing on-vehicle qualification should migrate to AEC-Q100-qualified successors.

🔬

Instrumentation Front-End for Test & Measurement

The MAX198BENI is well-suited as the analog front-end for bench-top test and measurement instruments such as multimeters, oscilloscope front-ends, and signal analyzers that need to digitize multiple signal sources simultaneously. The MAX198BENI's 12-bit resolution and 100 ksps throughput support mid-frequency measurement tasks, while its parallel interface enables real-time data streaming to an FPGA or DSP for waveform analysis. The MAX198BENI's fault protection simplifies the input protection network in commercial test instruments exposed to unknown user signals. The integrated 4.096V reference (5 ppm/°C) provides stable conversion accuracy for laboratory-grade measurements.

Zusammenfassung der empfohlenen Produkte

MAX197 8+4 bus interface variant of MAX198 family Verwendet in: Industrial Process Control & PLC Analog Input Modules MAX199 Bipolar-input version, drop-in upgrade Verwendet in: Industrial Process Control & PLC Analog Input Modules MAX196 Software-selectable input ranges including ±VREF bipolar Verwendet in: Industrial Process Control & PLC Analog Input Modules MAX190BCWG+T Maxim Integrated Verwendet in: Multi-Channel Data Logging Systems MAX1300 12-bit multi-channel SAR ADC with sequencer Verwendet in: Multi-Channel Data Logging Systems MAX178BCNG Maxim Integrated Verwendet in: Medical Patient Monitoring Equipment MAX1149 Higher-resolution medical ADC Verwendet in: Medical Patient Monitoring Equipment MAX147AEAP Analog Devices Verwendet in: HVAC and Building Automation Sensor Interfaces MAX1282AEEE Maxim Integrated Verwendet in: HVAC and Building Automation Sensor Interfaces MAX194BCPE Maxim Integrated Verwendet in: Automotive Diagnostic and Test Equipment MAX195BCWE Analog Devices Verwendet in: Automotive Diagnostic and Test Equipment MAX195BEWE Analog Devices Verwendet in: Instrumentation Front-End for Test & Measurement MAX187CEWE Maxim Integrated Verwendet in: Instrumentation Front-End for Test & Measurement
What is the MAX198BENI and what does it do?
The MAX198BENI is a 12-bit, 6-channel, multi-range data acquisition system (DAS) from Maxim Integrated that integrates an analog input multiplexer, track/hold, and successive-approximation ADC on a single +5V supply. According to the Maxim datasheet, it samples up to 100 ksps with 1/2-LSB linearity (B grade) and provides software-selectable input ranges of 0V to +VREF or 0V to +5V. Designers use it to digitize multiple analog sensors with one IC.
What is the input voltage range of MAX198BENI?
The MAX198BENI accepts unipolar analog inputs in two software-selectable ranges: 0V to +VREF (using the internal 4.096V reference or an external reference) and 0V to +5V. According to the Maxim datasheet, the fault-protected input multiplexer tolerates ±16V overvoltage without damage, eliminating the need for external clamping diodes in most industrial applications. The analog supply is a single +5V rail.
What is the resolution and sampling rate of MAX198BENI?
The MAX198BENI delivers 12-bit resolution at up to 100 ksps throughput. The -B grade of the family guarantees ±1/2-LSB INL and DNL linearity, making it suitable for precision measurement of slow analog signals. SAR architecture with an internal track-and-hold allows accurate acquisition of step inputs up to the Nyquist-limited input bandwidth of the converter.
Where can I buy MAX198BENI online and what is the price?
The MAX198BENI is in stock at major distributors including DigiKey, Mouser, Vyrian, and Xecor as of 2026-10-15. Pricing ranges from approximately $32.40 at quantity 1 down to $19.20 at 1000 pieces per the current distributor data. Lead time is typically 2-4 weeks for production quantities because the part is approaching end-of-life status (NRND), so engineers should evaluate second-source alternatives now.
What is the lead time for MAX198BENI?
The MAX198BENI has a typical lead time of 2-4 weeks at franchised distributors as of 2026-10-15, though the part is marked as Not Recommended for New Designs (NRND) by Maxim. Because of its NRND status, lead times can extend significantly if channel stock runs low. Engineers designing new products should consider the MAX198BCNI+, MAX198AENI+, or MAX197 equivalents as drop-in replacements.
Is MAX198BENI in stock at distributors?
Yes, the MAX198BENI is listed as in stock at DigiKey, Mouser, and other authorized distributors as of 2026-10-15, with approximately 42 units listed across inventory feeds. However, because the part is NRND (Not Recommended for New Designs), engineers should verify long-term availability with their preferred distributor and plan for migration to the MAX197 (8+4 bus interface) or MAX199 families if production life exceeds several years.
What is the best drop-in replacement for MAX198BENI?
The best drop-in replacement for MAX198BENI is the MAX198BCNI+ from Maxim Integrated, which shares the same 28-pin PDIP footprint, same 6-channel 12-bit 100 ksps architecture, and same software-selectable input ranges. The -B grade (BCNI+) provides identical 1/2-LSB linearity. For a minor spec change, the MAX198AENI+ (-A grade) drops linearity to ±1 LSB but is otherwise pin-compatible. Both alternatives come from the same Maxim datasheet family.
MAX198BENI vs MAX197 - which is better for an 8086 interface?
The MAX198BENI provides a 12-bit parallel interface directly compatible with 8086-style microprocessors, while the MAX197 uses an 8-bit multiplexed bus interface intended for 8051/68HC11 microcontrollers. According to the Maxim datasheet, the MAX198 was specifically designed for 16-bit parallel data buses. Choose the MAX197 if your microcontroller has only an 8-bit port, or choose the MAX198 for a 16-bit bus where you need to read conversions in a single read cycle.
When should I choose MAX198BENI over MAX199?
Choose the MAX198BENI when you need a 6-channel single-ended 12-bit 100 ksps DAS in a 28-pin PDIP, particularly for industrial process control with unipolar 0-5V or 0-VREF input ranges. Choose the MAX199 instead if you need ±VREF bipolar ranges or ±16V true bipolar fault-protected inputs, or if you need to share analog signal conditioning across both positive and negative swings. The MAX198 is unipolar only; the MAX199 adds bipolar capability.
Is MAX198BENI suitable for PLC analog input modules?
Yes, the MAX198BENI is well-suited for PLC analog input modules because it integrates 6 input channels with ±16V fault protection, eliminating the need for external op-amp buffers or protection diodes. According to the Maxim datasheet, the 100 ksps throughput supports typical PLC scan times of 1-10 ms per channel, and the parallel microprocessor interface simplifies connection to PLC CPUs. The NRND status means engineers should validate lifetime supply for long production runs.
Where can I download the MAX198BENI datasheet PDF?
The MAX198BENI datasheet PDF can be downloaded from the Analog Devices product page at https://www.analog.com/en/products/max198.html, which consolidates the MAX196/MAX198/MAX199 family datasheet. Mirror copies are also available at DigiChip, AllDatasheet, and DatasheetBank for reference. The datasheet contains the full pinout, electrical characteristics, timing diagrams, and application circuits.
What is the pinout of the MAX198BENI in 28-PDIP?
The MAX198BENI pinout in 28-pin PDIP places CH0-CH5 on pins 1-6, VDD on pin 7, AGND on pin 8, REF on pin 9, the internal reference-related components on pins 10-11, and digital interface signals (RD, WR, CS, HBEN, INT) on the right side of the package, with the 12-bit parallel data bus D0-D11 occupying the lower portion. The full pin-by-pin description is in the Maxim datasheet at https://www.analog.com/en/products/max198.html.
What is the difference between MAX198BENI and MAX198BCNI+?
The MAX198BENI is the B-grade linearity part in a 28-pin PDIP with ±1/2-LSB INL/DNL, while the MAX198BCNI+ is the same die in the same 28-pin PDIP package but is the lead-free RoHS-compliant version explicitly qualified for new designs. According to Maxim part numbering, the 'BENI' suffix historically indicates standard industrial / non-RoHS while 'BCNI+' indicates the same B-grade linearity with RoHS compliance. Both are drop-in compatible.
What are the key specifications engineers should know about MAX198BENI?
The MAX198BENI integrates 6 single-ended analog input channels, delivers 12-bit resolution at 100 ksps throughput, operates from a single +5V supply, and provides software-selectable unipolar input ranges of 0V to +VREF or 0V to +5V. The internal 4.096V reference (5 ppm/°C typical) and fault-protected ±16V input multiplexer simplify external protection circuits. The 28-pin PDIP package suits industrial and instrumentation designs.
What is the best Maxim equivalent for MAX198BENI if it goes obsolete?
If the MAX198BENI goes obsolete, the best Maxim equivalent is the MAX198BCNI+ (same B-grade linearity, same 28-pin PDIP, RoHS-compliant) followed by the MAX198AENI+ (lower-cost A-grade version with ±1 LSB linearity). For designers needing a longer production lifetime, the MAX197 (8-bit interface, 8-channel) or MAX199 (bipolar inputs) offer broader supply continuity. All three Maxim variants share the 28-pin PDIP footprint.

Technische Referenzdaten für MAX198BENI – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose the MAX198BENI for industrial process control, PLC analog input modules, and multi-channel data logging designs that require 6 unipolar 0-5V analog inputs with ±16V fault protection and a 12-bit parallel interface to a 16-bit microprocessor. Choose the MAX198BCNI+ for new designs requiring RoHS lead-free compliance - it is the same die in the same 28-PDIP package. Choose the MAX198AENI+ when ±1 LSB linearity is acceptable and you need a lower-cost option. Choose the MAX198BCAI when you need a surface-mount SSOP package. For designs requiring bipolar ±VREF input ranges, choose the MAX199 instead. For 8-bit bus interfaces, choose the MAX197. All MAX198 family variants share the same software command set and timing, so firmware migration is straightforward.

Vergleich mit Alternativen

Parameter Dieses Produkt MAX198BCNI+ MAX198AENI+ MAX198ACNI+ MAX198BCAI
Brand Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated
Package 28-PDIP (N) 28-PDIP (N) - same 28-PDIP (N) - same 28-PDIP (N) - same 28-PDIP (N) - same
Resolution 12 bit 12 bit 12 bit 12 bit 12 bit
Sampling Rate 100 ksps 100 ksps 100 ksps 100 ksps 100 ksps
Channels 6 single-ended 6 single-ended 6 single-ended 6 single-ended 6 single-ended
Linearity (INL/DNL) ±1/2 LSB (B grade) ±1/2 LSB (B grade) ±1 LSB (A grade) ±1 LSB (A grade) ±1/2 LSB (B grade)
Input Range 0V to +VREF or 0V to +5V 0V to +VREF or 0V to +5V 0V to +VREF or 0V to +5V 0V to +VREF or 0V to +5V 0V to +VREF or 0V to +5V
Fault-Protected Inputs ±16 V ±16 V ±16 V ±16 V ±16 V
RoHS Compliant no (BENI suffix) yes yes yes yes

Wichtigste Unterscheidungsmerkmale

  • RoHS lead-free replacement available from same Maxim family (vs. MAX198BENI vs MAX198BCNI+)
  • Lower-cost A-grade linearity option available (vs. MAX198BENI vs MAX198AENI+)
  • Surface-mount alternative available without changing the die (vs. MAX198BENI vs MAX198BCAI)

Designhinweise

Estimated: place a 0.1µF ceramic decoupling capacitor within 10mm of the VDD pin (pin 7) and a 10µF bulk tantalum or ceramic capacitor at the supply entry point. The MAX198BENI draws typically 6mA quiescent current; the analog and digital grounds should be joined at a single point near the AGND pin (pin 8) to prevent digital switching noise from coupling into the analog reference path.

Route the 12-bit parallel data bus (D0-D11) with matched trace lengths to avoid bus skew, since the read cycle is asynchronous and a slow bit could latch incorrectly. Keep analog input traces (CH0-CH5) away from digital bus traces; use a guard ground trace between them if PCB space allows. The MAX198BENI's internal reference requires REFADJ (pin 10) to be bypassed to AGND with a 0.01µF capacitor for low-noise operation.

Source impedance on the analog input should not exceed 1kΩ at 100 ksps to avoid conversion error; add an external buffer amplifier if your sensor output impedance is higher. The MAX198BENI unipolar input range cannot accept negative voltages - signals below 0V will damage the input or produce erroneous readings; use the MAX199 if you need bipolar input capability. The HBEN signal must be properly sequenced with RD to read the correct byte.

Compliance-Informationen

RoHS
Non Compliant
REACH
Compliant
AEC-Q100
Not Qualified
Bleifrei
No
Halogenfrei
Unknown
Konfliktmineralien
Compliant

MAX198BENI has the historical non-RoHS 'BENI' suffix; the MAX198BCNI+ is the RoHS lead-free drop-in alternative. Not AEC-Q100 qualified - choose automotive-grade successors for on-vehicle designs.

Daten verifiziert am: 2026-10-15 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

MAX198BENI datasheet MAX198BENI price Maxim 12-bit DAS 6-channel MAX198BCNI+ drop-in replacement MAX198 vs MAX199 MAX198 PLC analog input MAX198BENI pinout 28-PDIP fault-protected ADC ±16V MAX198 lead time stock Maxim Integrated NRND ADC 100 ksps 12-bit parallel ADC MAX198BENI buy

Verwandte Bauteile & Begriffe

Maxim Integrated Analog Devices MAX198BENI MAX198BCNI+ MAX198AENI+ MAX198ACNI+ MAX198BCAI MAX199 MAX197 MAX196 Data Acquisition System (DAS) SAR ADC Successive Approximation Register 12-bit ADC 6-channel analog multiplexer 28-pin PDIP PDIP package fault-protected input industrial process control PLC analog input RoHS AEC-Q100 4.096V reference track-and-hold
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
Gesamt: $0.00 USD
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen