HINWEIS ZUR LETZTEN BESTELLMÖGLICHKEIT: MC34SB0800AE nähert sich dem End-of-Life. Letztes Bestelldatum: Kontaktieren Sie uns. Verfügbare Alternativbauteile ansehen →
NXP Semiconductors

MC34SB0800AE - Octal Valve/Pump Controller SoC | NXP | LQFP-64

Teilenummer: MC34SB0800AE ⚠ Letzte Bestellmöglichkeit
Auf Lager Versand in 1–3 Werktagen
36 V max Vdss 2.25 A per channel Id 300 mOhm Rds(on) 64-pin LQFP-EP (10x10 mm) with exposed thermal pad Package Up to 5 kHz Speed
Ab $10.85 USD / Stück
MOQ: 1 |
Preis aktualisiert: 2026-10-15
Mengenpreise
Menge Stückpreis Gesamt
1 $18.5 $18,50
10 $16.42 $164,20
100 $14.1 $1.410,00
500 $12.05 $6.025,00
1.000 $10.85 $10.850,00
ℹ️ Alle Preise sind in USD

MC34SB0800AE Übersicht

The NXP MC34SB0800AE is a fully integrated octal valve and pump controller system-on-chip designed for harsh industrial environments, integrating eight low-side solenoid drivers, two high-side drivers, and a 5V/3.3V-capable DC motor pre-driver into a single 64-pin LQFP-EP (10x10 mm) package. According to the NXP datasheet for the SB0800 family, each low-side driver handles up to 2.25 A continuous with 300 mOhm Rdson and supports PWM frequencies up to 5 kHz, while the high-side drivers operate from the same 36 V supply rail used to power the solenoid loads.

A solenoid/valve controller PMIC is a power-management IC that integrates multiple half-bridge or low-side FET outputs with on-chip gate drivers, fault protection, and an SPI/digital control interface. It sits between the MCU control plane and the high-current actuator stage of an industrial or hydraulic system, replacing dozens of discrete MOSFETs, sense amps, and freewheeling diodes with a single AEC-stress-tested IC. The MC34SB0800AE in particular targets hydraulic proportional valves, DC pump motors, and solenoid banks in mobile equipment, agricultural vehicles, construction machinery, and process-control cabinets where PCB area and reliability are paramount.

Key differentiating features include parallel low-side outputs (four regulated and four digital) for proportional valve control, an integrated charge pump to drive the high-side N-MOSFETs from a single supply, comprehensive diagnostic feedback via SPI, and built-in protection such as over-current, open-load, over-temperature, and reverse-battery detection. The device operates across an ambient range of -40 C to +125 C and is qualified for industrial-grade harsh-environment use.

Typical applications include hydraulic proportional valve drive in electrohydraulic actuators, DC pump and brush motor control, HVAC damper and valve actuation, agricultural sprayer solenoid control, construction equipment hydraulic manifolds, and process-control solenoid banks. The combination of eight low-side and two high-side outputs allows a single IC to drive a complete proportional valve assembly with redundant diagnostics.

When designing with this part, allocate adequate copper area beneath the exposed pad (EP) for thermal dissipation - each low-side output can dissipate several watts under stalled-load conditions. Decouple the logic and driver rails separately, and always include reverse-battery protection at the supply input because the SB0800 does not internally block reverse polarity.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet alone, helping procurement and design engineers evaluate lifecycle risk and pin-compatible second sources.

Drop-in-Alternativen für MC34SB0800AE – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:

MC34SB0800AER2

✅ Drop-In
📦 64-LQFP-EP (10x10)
same die, R2 reel-pack variant for SMT assembly (vs AE tray)

📋 Referenzalternative (nicht im Katalog)

MC34SB0800

✅ Drop-In ⚠️ Spezifikationen ungeprüft
📦 64-LQFP-EP (10x10)
same die without AE suffix; identical SB0800 silicon, minor ordering-code difference

📋 Referenzalternative (nicht im Katalog)

MCZ33999EFR2

✅ Drop-In
📦 64-LQFP-EP
NXP SBC family, 6 low-side + 4 high-side drivers; different SPI map; same LQFP-EP 64 footprint (~75% param match)

📋 Referenzalternative (nicht im Katalog)

MC34SB0800AE Grenzwerte & elektrische Eigenschaften

Product Type Pump / Valve Controller PMIC (Octal Solenoid Driver + DC Motor Pre-Driver)
Number of Low-Side Drivers 8 (4 regulated + 4 digital)
Number of High-Side Drivers 2 (pre-drivers for external N-MOSFETs)
Supply Voltage (VBAT) 36 V max
Low-Side Continuous Current 2.25 A per channel
Low-Side Rdson 300 mOhm
PWM Frequency Up to 5 kHz
Communication Interface SPI (per datasheet family)
Betriebstemperaturbereich -40 C to +125 C
Gehäuse 64-pin LQFP-EP (10x10 mm) with exposed thermal pad
Montageart Surface Mount
Diagnostics Open-load, over-current, over-temperature, reverse-battery detection
Charge Pump Integrated (drives high-side N-MOSFETs)
RoHS-Status Compliant
Automotive Grade Industrial grade (AEC-Q100 not explicitly stated in provided data)
Target Environment Harsh industrial (mobile equipment, hydraulics, agriculture)

MC34SB0800AE 64-pin lqfp-ep (10x10 mm) with exposed thermal pad Pinbelegungsleitfaden

Pinbelegung für MC34SB0800AE (64-pin lqfp-ep (10x10 mm) with exposed thermal pad-Gehäuse). Dieses Leistungsbauteil verfügt über Gate-, Drain- und Source-Anschlüsse. Bei nicht gepolten Gehäusen entnehmen Sie die genaue Ausrichtung von Pin 1 und Footprint-Details dem Herstellerdatenblatt. Typische Anwendungen sind Netzteilentwurf, Motoransteuerung und Lastschaltung.

Pinbelegungsdiagramm für MC34SB0800AE im 64-pin lqfp-ep (10x10 mm) with exposed thermal pad-Gehäuse

Keine detaillierten Pinbelegungsdaten verfügbar für MC34SB0800AE.

Siehe die Datenblatt für die vollständige Pin-Konfiguration.

Typische Anwendungen

MC34SB0800AE ist geeignet für 7 Anwendungs: Hydraulic Proportional Valve Control, DC Pump and Brush Motor Drive, Agricultural Equipment Solenoid Banks, Construction Machinery Hydraulic Control, Industrial Process Control Valve Manifolds, HVAC Damper and Valve Actuation, Mobile Equipment Battery-Protection Systems.

🏭

Hydraulic Proportional Valve Control

The MC34SB0800AE's eight low-side outputs (4 regulated for closed-loop current control + 4 digital for on/off valves) directly drive the solenoid coils of hydraulic proportional valves in electrohydraulic actuators. Each low-side output's 2.25 A continuous rating and 5 kHz PWM capability allow precise dithered current control, which is critical for valve spool positioning accuracy and smooth hydraulic motion. The two integrated high-side pre-drivers can drive external N-MOSFETs for high-side switching of common-rail hydraulic valves, eliminating the need for an external charge pump circuit. In a typical mobile-equipment hydraulic manifold, this single LQFP-EP IC replaces 8-12 discrete MOSFETs and associated gate drivers, freeing PCB area for sensor signal conditioning.

⚡

DC Pump and Brush Motor Drive

The MC34SB0800AE's integrated high-side pre-drivers (with internal charge pump) and regulated low-side outputs form a compact half-bridge pair well-suited to DC pump motor control. The internal charge pump generates gate-drive voltage for the external high-side N-MOSFETs from the 36 V VBAT rail, removing the BOM cost of an external bootstrap or charge-pump IC. With 2.25 A per low-side and PWM up to 5 kHz, the SB0800 can regulate pump flow precisely via duty-cycle control. Reverse-battery detection built into the device protects the motor and electronics from miswiring during field installation.

🚗

Agricultural Equipment Solenoid Banks

In agricultural vehicles such as tractors, sprayers, and seeders, the MC34SB0800AE drives banks of solenoid valves that control seed metering, spray nozzles, hydraulic remotes, and implement actuators. The industrial -40 C to +125 C temperature rating handles engine-bay thermal stress, and the integrated SPI diagnostics allow the implement controller to log solenoid health for predictive maintenance. The 36 V VBAT tolerance accommodates 24 V agricultural bus systems with significant load-dump transients. Each regulated low-side output's 2.25 A capability matches typical proportional control solenoids on the implement hydraulics.

🏭

Construction Machinery Hydraulic Control

The MC34SB0800AE is widely used in excavators, skid-steers, and telehandlers where multiple proportional and on/off hydraulic valves must be controlled from a single electronic control unit. The device's 36 V maximum VBAT tolerates load-dump on 24 V machine buses, while the integrated high-side pre-drivers simplify the BOM of high-bom capacitive valves that require high-side switching. The exposed thermal pad of the LQFP-EP package, when soldered to a sufficient copper pour, dissipates the heat from eight low-side outputs simultaneously under stalled-load conditions common in cold-start hydraulic actuation.

🏭

Industrial Process Control Valve Manifolds

Process-control cabinets in chemical, oil & gas, and water-treatment plants use solenoid valve manifolds to route fluids, and the MC34SB0800AE drives up to 8 valves plus 2 actuator pre-drivers from one IC. The industrial temperature rating, SPI fault reporting (open-load, over-temperature, over-current, reverse-battery), and 36 V VBAT tolerance suit 24 VDC and 30 VDC plant busses. The LQFP-EP 64 footprint allows compact manifold-mounted PCBAs, and the integrated charge pump removes the external high-side supply complication that discrete solutions require.

🏭

HVAC Damper and Valve Actuation

Commercial HVAC systems use proportional hot-water and chilled-water valves plus on/off damper actuators, and the MC34SB0800AE drives a complete zone manifold from a single IC. The regulated low-side outputs handle proportional water valves via PWM current control, while the digital low-side outputs drive on/off zone dampers. The 5 kHz PWM frequency is well above the audible band, avoiding valve chatter noise, and the 36 V tolerance handles rectified 24 VAC supplies commonly used in building automation. SPI diagnostics enable BACnet or Modbus-connected BMS controllers to log actuator health for preventive maintenance scheduling.

🔋

Mobile Equipment Battery-Protection Systems

Beyond pure valve control, the MC34SB0800AE's reverse-battery detection, over-current shutdown, and open-load diagnostics make it suitable as a protected low-side driver bank in mobile-equipment battery-protection modules. The two high-side pre-drivers can also serve as solid-state relay drivers for battery disconnect contactors. Operating from the same 36 V DC bus that powers the equipment, the SB0800 simplifies the safety architecture by combining driver, protection, and diagnostics in one AEC-stress-tested IC.

Zusammenfassung der empfohlenen Produkte

MC34SB0800AER2 Reel-pack drop-in variant for high-volume SMT Verwendet in: Hydraulic Proportional Valve Control, DC Pump and Brush Motor Drive, Construction Machinery Hydraulic Control, HVAC Damper and Valve Actuation MCZ33999EFR2 NXP System Basis Chip for adjacent power management Verwendet in: Hydraulic Proportional Valve Control, Agricultural Equipment Solenoid Banks, Industrial Process Control Valve Manifolds, Mobile Equipment Battery-Protection Systems
What does the MC34SB0800AE do?
The MC34SB0800AE is an octal valve and pump controller system-on-chip that integrates eight low-side solenoid drivers (4 regulated + 4 digital) and two high-side pre-drivers for external N-MOSFETs into one 64-pin LQFP-EP IC. Per the NXP SB0800 datasheet, it is designed to drive hydraulic proportional valves, DC pump motors, and solenoid banks in harsh industrial environments with built-in SPI diagnostics.
What is the maximum supply voltage for the MC34SB0800AE?
The MC34SB0800AE supports a maximum battery supply voltage (VBAT) of 36 V across its industrial temperature range of -40 C to +125 C. The integrated charge pump generates the gate-drive voltage for the high-side N-MOSFET pre-drivers from this single supply rail, simplifying the BOM.
How much current can each low-side driver deliver?
Each of the eight low-side outputs of the MC34SB0800AE is rated for 2.25 A continuous current at a typical Rdson of 300 mOhm. PWM switching up to 5 kHz is supported for proportional valve current regulation, with on-chip diagnostics reporting open-load and short-to-supply faults over SPI.
Where can I download the MC34SB0800AE datasheet?
The official MC34SB0800AE datasheet (covering the SB0800 family) is hosted at https://www.nxp.com/docs/en/data-sheet/MC34SB0800.pdf. The datasheet includes absolute maximum ratings, SPI register map, application schematic, and thermal layout guidance for the LQFP-EP 64-pin package.
Is the MC34SB0800AE still in production?
According to the NXP product page, the MC34SB0800AE is in its End-of-Life / Discontinuance phase and is no longer recommended for new designs. Per the official product page, NXP has issued a Product Discontinuance Notice; consider the pin-compatible SB0800 family successor or a Rochester Electronics stock for ongoing production.
What is the difference between MC34SB0800AE and MC34SB0800AER2?
The MC34SB0800AE is the base LQFP-EP 64 tray packing option, while MC34SB0800AER2 is the identical silicon supplied on a 13-inch reel (R2 suffix) for high-volume SMT assembly. Both share the same 8 low-side / 2 high-side driver architecture, 36 V VBAT, 2.25 A LSD rating, and 300 mOhm Rdson, making them drop-in equivalents with only packaging differences.
What is the best drop-in replacement for MC34SB0800AE?
There is no exact pin-compatible drop-in from a different manufacturer because the SB0800 family has a proprietary SPI register map and integrated high-side gate-drive architecture. The safest drop-in path is the same NXP SB0800 family on reel (MC34SB0800AER2) or authorized Rochester Electronics stock of the original AE suffix. Always re-validate SPI register behavior before swapping silicon lots.
How does MC34SB0800AE compare to a discrete MOSFET half-bridge design?
The MC34SB0800AE replaces roughly 8 discrete low-side N-MOSFETs, 2 high-side N-MOSFETs with charge pump, gate drivers, sense resistors, freewheeling diodes, and a fault-monitoring MCU ADC chain with a single 10x10 mm LQFP-EP IC. Trade-off: it sacrifices flexibility on Rdson and PWM frequency (capped at 5 kHz) but gains PCB area, EMI consistency, and SPI-based diagnostics.
What package does the MC34SB0800AE use?
The MC34SB0800AE is housed in a 64-pin LQFP-EP (low-profile quad flat pack with exposed pad) measuring 10 mm x 10 mm with 0.5 mm pitch. The exposed pad must be soldered to a copper pour for thermal dissipation - each channel can dissipate several watts under stalled-load conditions.
Can the MC34SB0800AE drive a DC pump motor directly?
Yes, the MC34SB0800AE integrates a dedicated high-side/low-side pre-driver pair intended for DC pump motor control. The two high-side outputs drive external N-MOSFETs via the internal charge pump, while the regulated low-side outputs can PWM the return path. For reversible pump direction, an external H-bridge built from the SB0800 high/low-side pairs is required.
Where can I buy MC34SB0800AE online?
As of 2026-10-15, MC34SB0800AE is listed on DigiKey (https://www.digikey.com/en/products/detail/nxp-usa-inc/MC34SB0800AE/5321340) and Mouser (https://www.mouser.com/ProductDetail/NXP-Semiconductors/MC34SB0800AE), with authorized-stock distributor Rochester Electronics also carrying inventory. Because the part is in NXP's discontinuance phase, confirm availability and lead time before placing new orders.
What is the lead time for MC34SB0800AE?
Per the NXP product page (as of 2026-10-15), the MC34SB0800AE is in discontinuance with a published Last Time Buy window. Authorized distributors like DigiKey and Mouser may still show factory stock or Rochester Electronics inventory, but lead times can extend to 12-26 weeks once factory stock is depleted. Plan second-source qualification early.
Is the MC34SB0800AE RoHS compliant?
Yes, the MC34SB0800AE is RoHS compliant per the NXP product page. The LQFP-EP 64 package uses lead-free (Pb-free) matte-tin plating suitable for reflow profiles up to 260 C peak temperature per JEDEC J-STD-020. REACH compliance and conflict-mineral reporting status should be confirmed directly with NXP for production documentation.
When should I choose MC34SB0800AE over a discrete driver design?
Choose the MC34SB0800AE when PCB area is constrained (a single 10x10 mm LQFP-EP replaces dozens of discretes), when SPI diagnostics are required for functional-safety compliance, and when driving 4-8 proportional solenoid valves plus a DC pump in one hydraulic manifold. Avoid it when you need >5 kHz PWM, currents above 2.25 A continuous, or non-LQFP-EP packages - those cases favor discrete MOSFET designs.
What fault diagnostics does MC34SB0800AE provide?
The MC34SB0800AE integrates open-load detection, short-to-ground and short-to-supply detection, over-current limiting, over-temperature shutdown, and reverse-battery detection per the SB0800 datasheet. All faults are reported over the SPI status registers, allowing the host MCU to take protective action or log the error for predictive maintenance.

Technische Referenzdaten für MC34SB0800AE – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose the MC34SB0800AE when you need to drive 4-8 proportional hydraulic or pneumatic solenoid valves plus optional high-side loads in a single compact 10x10 mm LQFP-EP IC, particularly in industrial mobile machinery, construction equipment, or process-control manifolds. The integrated charge pump and SPI diagnostics eliminate the external circuitry that discrete designs require. Avoid the part for new designs because NXP has issued an EOL/discontinuance notice; qualify MCZ33999EFR2 or the SB0800 family successor before committing to new production. For drop-in replacement of existing installed boards, source MC34SB0800AER2 (reel-pack) or Rochester Electronics authorized stock of the AE variant. The MCZ33999EFR2 is pin-compatible in package but uses a different SPI register map and is limited to 6 low-side / 0.6 A channels, so it is a functional substitute for lighter loads, not a true drop-in.

Vergleich mit Alternativen

Parameter Dieses Produkt MC34SB0800AER2 MC34SB0800 MCZ33999EFR2
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 64-LQFP-EP (10x10 mm) 64-LQFP-EP (10x10 mm) - same 64-LQFP-EP (10x10 mm) - same 64-LQFP-EP - same
Low-Side Drivers 8 (4 regulated + 4 digital) 8 (4 regulated + 4 digital) 8 (4 regulated + 4 digital) 6 low-side
High-Side Pre-Drivers 2 2 2 4 high-side switches
Max Supply Voltage 36 V 36 V 36 V 27 V (12 V system SBC)
Low-Side Continuous Current 2.25 A 2.25 A 2.25 A 0.6 A
Operating Temperature -40 C to +125 C -40 C to +125 C -40 C to +125 C -40 C to +125 C
Lifecycle Status Last Time Buy (discontinuance) Last Time Buy Active Active

Wichtigste Unterscheidungsmerkmale

  • Highest low-side current per channel in 64-LQFP-EP class (vs. MCZ33999EFR2)
  • Eight low-side outputs (4 regulated + 4 digital) (vs. MCZ33999EFR2)
  • Integrated charge pump for high-side N-MOSFETs (vs. Discrete MOSFET drivers)

Designhinweise

The 64-LQFP-EP package relies on the exposed pad for thermal dissipation. Under stalled low-side output conditions, each channel can dissipate 5-10 W. Estimate: with all 8 low-sides active at 2 A continuous into a short, total dissipation can approach 30-40 W; design the PCB with at least 4 square inches of top-layer copper connected to the exposed pad, plus thermal vias to inner planes. Without adequate copper, junction temperature will exceed 125 C and trigger thermal shutdown.

Add reverse-battery protection (e.g., a P-MOSFET or Schottky diode) at the VBAT input. The SB0800 has reverse-battery detection for diagnostics but does not block sustained reverse polarity, which can damage the charge pump and gate drivers. Use a low-Vf Schottky if diode drop is unacceptable. Decouple VBAT with at least 100 uF bulk plus 100 nF ceramic placed within 5 mm of the supply pins.

Route the low-side driver return paths directly back to the EP ground pad using wide, short traces to avoid ground bounce that can corrupt SPI communication. Keep the analog/digital ground split tight at the IC, and use a single star-ground at the exposed pad. Place the SPI signals on an inner layer with ground shielding if the application is electrically noisy (e.g., motor PWM edges).

Compliance-Informationen

RoHS
Compliant
REACH
Compliant
AEC-Q100
Unknown
Bleifrei
Yes
Halogenfrei
Unknown
Konfliktmineralien
Compliant

RoHS compliant per NXP product page. AEC-Q100 qualification status not explicitly stated in provided data; marked as 'unknown'. Lead-free plating confirmed for SMT reflow compatibility.

Daten verifiziert am: 2026-10-15 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

MC34SB0800AE MC34SB0800AE datasheet NXP MC34SB0800AE octal valve controller 8 low side 2 high side solenoid driver 36V LQFP-64 valve controller PMIC MC34SB0800AE hydraulic proportional valve drive MC34SB0800AE vs MC34SB0800AER2 MC34SB0800AE drop-in replacement MC34SB0800AE buy price stock what is the operating voltage of MC34SB0800AE octal low side solenoid driver IC 2.25A pump valve controller PMIC harsh industrial

Verwandte Bauteile & Begriffe

NXP Semiconductors MC34SB0800AE MC34SB0800AER2 MC34SB0800 MCZ33999EFR2 Freescale Semiconductor octal valve controller pump controller PMIC solenoid driver low-side driver high-side pre-driver LQFP-EP LQFP-64 exposed thermal pad SPI PWM charge pump N-MOSFET AEC-Q100 RoHS hydraulic proportional valve DC pump motor agricultural equipment construction machinery industrial process control
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
Gesamt: $0.00 USD
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen