Monolithic Power Systems

MP8110DK-LF-Z - 40V High-Side Current Sense Amp | MPS

Teilenummer: MP8110DK-LF-Z ✓ Aktiv
2.5 V to 40 V Vdss 8-MSOP Package
MOQ: 1 |

MP8110DK-LF-Z Übersicht

Monolithic Power Systems Inc. MP8110DK-LF-Z is a single-circuit, precision high-side current-sense amplifier with a 2.5 V to 40 V input-voltage range and a 1 V output corresponding to 5 A of load current, housed in an 8-pin MSOP package. The device is intended to monitor current in a high-side supply rail while producing an analog voltage proportional to the measured load current.

A high-side current-sense amplifier is an instrumentation amplifier that measures the small voltage drop across a sense resistor placed in series with a power path. The MP8110 belongs to the current-sense amplifier category, which is part of the broader analog and mixed-signal IC hierarchy. Its high-side placement keeps the monitored load near ground potential, making it useful in systems where the current-carrying conductor is difficult to bring to a low-voltage analog input.

The verified manufacturer information identifies a 2.5 V to 40 V operating input range, a typical 17 µA supply consumption, one amplifier circuit, and a nominal transfer relationship in which 1 V of output represents 5 A of load current. This 0.2 V/A relationship provides a direct way to interpret the output voltage during current measurements. The 40 V capability supports measurement of high-voltage rails without requiring the amplifier to be placed directly across the full supply voltage.

The MP8110DK-LF-Z is described by the manufacturer as a low-cost, precision, high-side current-sense amplifier. Its proportional analog output can be connected to an ADC, comparator, controller, or monitoring circuit so that the host system can measure load current or react when a programmed threshold is exceeded. The manufacturer also documents the EV8110DS-00A evaluation board for evaluating the MP8110 in a complete application circuit.

Typical uses include power-supply load monitoring, battery-powered systems, industrial controllers, motor-control circuits, and general 40 V power rails. Because the output scales at 0.2 V per ampere, a 5 A load produces a 1 V output according to the manufacturer product-page information. Designers should verify the required sense-resistor value, output range, error limits, and operating conditions against the complete manufacturer datasheet before production use.

A primary design consideration is Kelvin routing of the sense-resistor connections. The amplifier must detect the voltage drop across the sense resistor without picking up voltage drops in its own supply and ground traces. Short, symmetric connections, suitable resistor placement, and a clean return path help preserve measurement accuracy. The analog output should also remain within the input range of the receiving ADC or controller.

This page consolidates the verified manufacturer and distributor information for MP8110DK-LF-Z, including the known electrical characteristics, package information, sourcing links, and practical application guidance. It also separates documented values from parameters that still require confirmation from the full datasheet, helping engineers make faster and more defensible component-selection decisions.

Drop-in-Alternativen für MP8110DK-LF-Z – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Varianten dieser Serie

Modelle derselben Serie, die drop-in-kompatibel sind mit MP8110DK-LF-Z (gleiche Bauform und Footprint) – abweichend in RoHS Status.

Monolithic Power Systems
RoHS Status: Not stated in verified data
Vergleichen mit MP8110DK-LF-Z →

Für dieses Produkt sind keine Drop-in-Alternativen verfügbar.

Alternativen anfordern

MP8110DK-LF-Z Grenzwerte & elektrische Eigenschaften

Device Type Precision high-side current-sense amplifier
Circuit Count 1 circuit
Eingangsspannungsbereich 2.5 V to 40 V
Versorgungsspannung 2.5 V to 40 V
Nominal Output at 5 A Load 1 V
Nominal Output Sensitivity 0.2 V/A
Typical Supply Consumption 17 µA
Gehäuse 8-MSOP
Pin-Anzahl 8 pins
Montageart Surface mount
Lead-Free Status Compliant
RoHS-Status RoHS3 compliant

MP8110DK-LF-Z 8-msop Pinbelegungsleitfaden

Pinbelegung für MP8110DK-LF-Z (8-msop-Gehäuse). Dieses analoge Bauteil verfügt über Eingangs-, Ausgangs- und Versorgungspins. Offset-Null-, Kompensations- und Enable-Pin-Konfigurationen entnehmen Sie dem Herstellerdatenblatt. Ideal für Signalaufbereitung und Verstärkerschaltungen.

Pinbelegungsdiagramm für MP8110DK-LF-Z im 8-msop-Gehäuse

Keine detaillierten Pinbelegungsdaten verfügbar für MP8110DK-LF-Z.

Siehe die Datenblatt für die vollständige Pin-Konfiguration.

Typische Anwendungen

MP8110DK-LF-Z ist geeignet für 6 Anwendungs: 40 V Power-Supply Load Monitoring, Battery-Powered System Current Sensing, Industrial Controller Current Feedback, Motor and Actuator Supply Monitoring, Over-Current Threshold Detection, High-Voltage DC Rail Protection.

⚡

40 V Power-Supply Load Monitoring

The MP8110DK-LF-Z suits high-side load monitoring in a 2.5 V to 40 V power rail because the documented input range accommodates the monitored bus. A series sense resistor develops a voltage proportional to load current, and the amplifier converts that differential drop into a 1 V output at 5 A. The resulting analog signal can feed an ADC, comparator, or controller for load reporting or threshold protection. Designers should use Kelvin-routed connections to the sense resistor and confirm that the output remains within the receiving circuit’s input limits.

📱

Battery-Powered System Current Sensing

The MP8110DK-LF-Z can monitor current in a battery-powered load path while keeping the sensing element on the high side. Its 17 µA typical supply consumption is relevant when conserving system energy, and the documented 2.5 V to 40 V operating range supports multiple battery and industrial supply architectures. A 5 A condition produces a 1 V output according to the manufacturer, giving the host controller a straightforward proportional signal for current tracking, energy accounting, or an over-current indication.

🏭

Industrial Controller Current Feedback

The MP8110DK-LF-Z provides an analog current-feedback signal for industrial controllers monitoring a high-side supply. Its documented 40 V input range supports control and automation systems that operate above conventional low-voltage logic levels, while the 0.2 V/A nominal sensitivity translates current into a controller-readable voltage. The sensing path requires careful layout: the sense-resistor Kelvin connections should be short and symmetric, and the analog output should be checked for adequate range and settling behavior in the selected control loop.

🔧

Motor and Actuator Supply Monitoring

The MP8110DK-LF-Z can be used to monitor current drawn by a motor or actuator from a high-side supply without placing the sensing amplifier at ground potential. At a 5 A load, the documented output is 1 V, allowing an MCU or analog input to estimate operating current and detect abnormal loading. Because motor systems can produce transients, the engineer must verify transient limits, common-mode behavior, and the sense-resistor pulse rating from the complete datasheet before finalizing the circuit.

🔧

Over-Current Threshold Detection

The MP8110DK-LF-Z can drive a comparator or controller input for over-current detection in a high-side power path. Its proportional output reaches 1 V at the documented 5 A reference condition, making it possible to select a threshold and protective behavior around a known operating current. The complete implementation must include the correct sense resistor, verify amplifier accuracy at the threshold, and account for output limits, temperature effects, and any transient behavior before defining the shutdown policy.

⚡

High-Voltage DC Rail Protection

The MP8110DK-LF-Z is applicable to monitoring a high-voltage DC rail when the system operates within the documented 2.5 V to 40 V range. The amplifier converts the sense-resistor drop into a proportional analog voltage that a protection controller can compare against an operating limit. High-side placement simplifies grounding of the monitored equipment, but robust design still requires examining the sense resistor’s voltage rating, pulse capability, power dissipation, and the amplifier’s detailed operating and transient limits.

Zusammenfassung der empfohlenen Produkte

EV8110DS-00A Manufacturer evaluation board for MP8110 Verwendet in: 40 V Power-Supply Load Monitoring, Battery-Powered System Current Sensing, Industrial Controller Current Feedback, Motor and Actuator Supply Monitoring, Over-Current Threshold Detection, High-Voltage DC Rail Protection
What is the MP8110DK-LF-Z?
The MP8110DK-LF-Z is a single-circuit, precision high-side current-sense amplifier from Monolithic Power Systems Inc. According to the manufacturer product page, it accepts a 2.5 V to 40 V input-voltage range, typically consumes 17 µA, and is packaged in an 8-MSOP. It produces an output voltage proportional to current in the monitored high-side power path.
What is the operating voltage of MP8110DK-LF-Z?
The MP8110DK-LF-Z operates from a single supply in the 2.5 V to 40 V range. According to the Monolithic Power Systems product page, the same 2.5 V to 40 V interval is also identified as the input-voltage range. This operating capability makes the device appropriate for measuring current in high-side rails up to the documented 40 V limit.
What is the output voltage of MP8110DK-LF-Z at 5 A?
The MP8110DK-LF-Z produces a 1 V output for a 5 A load according to the manufacturer product page. This corresponds to a nominal sensitivity of 0.2 V/A. Designers can therefore calculate an expected output by multiplying the measured load current by 0.2 V/A, while still checking the complete datasheet for gain and accuracy tolerances.
What are the key specifications of MP8110DK-LF-Z that engineers should know?
The key documented specifications are a 2.5 V to 40 V input range, 17 µA typical supply consumption, a 1 V output at a 5 A load, one amplifier circuit, and an 8-MSOP package. According to the Monolithic Power Systems product page, the nominal output sensitivity is 0.2 V/A. These figures summarize the core electrical and packaging information available for design triage.
Where can I buy MP8110DK-LF-Z online?
MP8110DK-LF-Z is available through multiple authorized component distributors, including DigiKey Electronics and Mouser. The verified DigiKey listing identifies it as an 8-MSOP current-sense amplifier, while Mouser describes it as a 40 V precision high-side current-sense amplifier. Pricing and stock should be checked at the distributor because the supplied data does not confirm current inventory.
What is the price of MP8110DK-LF-Z?
The only verified unit price supplied for MP8110DK-LF-Z is $0.71 at a 2500-piece quantity as of 2026-10-28. Prices for quantities of 1, 10, 100, 500, and 1000 were not provided by the verified sources and must be checked with DigiKey, Mouser, or another authorized distributor before quotation or purchase.
What is the lead time for MP8110DK-LF-Z?
A numeric lead time for MP8110DK-LF-Z is not established by the supplied verified data. The DigiKey result says the part can be purchased and shipped today, but that statement is not a guaranteed lead-time figure. Request a firm quotation from the selected distributor to confirm current stock, factory lead time, and the quantity available for allocation.
Is MP8110DK-LF-Z in stock?
The verified DigiKey listing states “Buy now, ships today,” which indicates that the distributor offered the MP8110DK-LF-Z for immediate ordering when the result was captured. However, stock levels change quickly and no numeric inventory quantity was provided. Confirm current availability with the distributor before committing the component to a production schedule.
Where can I download the MP8110DK-LF-Z datasheet PDF?
The official MP8110 product page is available at monolithicpower.com and links to the manufacturer’s MP8110 documentation. A separate verified datasheet listing is also available through AllDataSheet. The supplied source identifies the document as 10 pages, but its full technical tables must be consulted for gain error, common-mode range, output limits, and electrical characteristics.
Where can I find the MP8110DK-LF-Z pinout?
The MP8110DK-LF-Z pinout is published in the manufacturer MP8110 datasheet associated with the official product page. The verified distributor information confirms an 8-MSOP package, but the supplied snippets do not provide individual pin names. Use the manufacturer diagram rather than assuming pin functions, especially for supply, ground, input, and output connections.
How is MP8110DK-LF-Z used for high-side current sensing?
The MP8110DK-LF-Z measures the small voltage developed across a series sense resistor in a high-side power conductor and converts that drop into an analog output proportional to load current. According to the manufacturer, 1 V output corresponds to 5 A load current. The circuit must use Kelvin connections so that trace resistance does not add an unintended error term.
Can MP8110DK-LF-Z replace another current-sense amplifier?
A drop-in replacement can be selected only after verifying package geometry, pin assignment, common-mode range, gain, bandwidth, output swing, and accuracy. The supplied cross-reference results contain generic search tools but do not identify a verified pin-compatible substitute for MP8110DK-LF-Z. Consequently, no drop-in alternative is asserted, and a replacement should not be approved from similarity alone.
What can replace MP8110DK-LF-Z?
No verified drop-in replacement for MP8110DK-LF-Z is identified in the supplied cross-reference data. The correct replacement process is to compare the 8-MSOP pinout, 2.5 V to 40 V operating range, 0.2 V/A nominal sensitivity, and the accuracy and common-mode requirements of the incumbent circuit. Parts with similar descriptions but different pin assignments are not drop-in substitutes.
What is the best Monolithic Power Systems equivalent for MP8110DK-LF-Z?
The verified sources identify the MP8110 family and the EV8110DS-00A evaluation board, but they do not document a separate pin-compatible Monolithic Power Systems substitute. The closest same-family device would therefore be another MP8110 package or ordering variant only if its datasheet confirms an identical pinout and electrical configuration. No unverified MPN is presented as a drop-in replacement.
Is MP8110DK-LF-Z suitable for 40 V industrial power systems?
The MP8110DK-LF-Z is suitable for current measurement in systems operating within its documented 2.5 V to 40 V range. Its 1 V output at 5 A and 17 µA typical consumption make it useful for controller, ADC, or threshold-monitoring circuits. Industrial suitability still depends on the complete datasheet’s temperature range, accuracy limits, and EMC performance.

Technische Referenzdaten für MP8110DK-LF-Z – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose MP8110DK-LF-Z when the design requires a single-channel, high-side current measurement in a 2.5 V to 40 V rail and an output proportional to load current. Its documented 1 V output at 5 A provides a simple conversion for ADC, comparator, and controller inputs, while typical supply consumption is 17 µA. The 8-MSOP format supports compact implementations. Before final selection, verify the complete datasheet for gain tolerance, common-mode range, bandwidth, output swing, temperature limits, and exact pin assignments. No drop-in substitute is recommended from the supplied evidence because the cross-reference results did not identify a pin-compatible replacement. If another device is considered, compare its footprint and pinout, supply range, gain, output response, and accuracy rather than relying on the shared MSOP package or the generic current-sense-amplifier description.

Vergleich mit Alternativen

Parameter Dieses Produkt
Package 8-MSOP
Brand Monolithic Power Systems Inc.
Device Type Precision high-side current-sense amplifier
Input Voltage Range 2.5 V to 40 V
Supply Voltage 2.5 V to 40 V
Nominal Output at 5 A Load 1 V
Nominal Output Sensitivity 0.2 V/A
Typical Supply Consumption 17 µA
Circuit Count 1 circuit
RoHS Status RoHS3 compliant

Wichtigste Unterscheidungsmerkmale

  • Documented 40 V high-side operating capability (vs. No verified drop-in alternative was identified)
  • Direct proportional current output (vs. No verified drop-in alternative was identified)
  • Low typical supply consumption (vs. No verified drop-in alternative was identified)

Designhinweise

Route the two sense-resistor connections as a differential, Kelvin pair directly from the resistor pads to the amplifier. Keep these traces short, matched, and away from switching nodes and high-current return paths. The amplifier detects only the voltage across the sense resistor, so voltage drops in copper traces would otherwise appear as measurement error. Place the sense resistor close enough to the monitored conductor to minimize unwanted loop area.

Do not assume that a generic 8-MSOP current-sense amplifier is pin-compatible with MP8110DK-LF-Z. The supplied snippets establish the package size but do not expose the individual pin assignments. Verify the manufacturer pin diagram, input polarity, supply pins, output pin, and exposed or no-connect positions before substituting any device. A footprint match alone does not establish functional compatibility.

Select the sense resistor from both the required measurement range and its own dissipation and pulse ratings. The manufacturer establishes 1 V output at 5 A load, but the full accuracy, common-mode range, and output-swing limits must be confirmed from the complete datasheet. Ensure the amplifier supply remains within 2.5 V to 40 V and that the output cannot exceed the input range of the receiving ADC or controller.

Compliance-Informationen

RoHS
Compliant
REACH
Unknown
AEC-Q100
Unknown
Bleifrei
Yes
Halogenfrei
Unknown
Konfliktmineralien
Unknown

A verified distributor source identifies MP8110DK-LF-Z as RoHS3 compliant and lead-free. No verified REACH, AEC-Q100, halogen-free, or conflict-minerals information was supplied.

Ähnliche Suchanfragen

MP8110DK-LF-Z MP8110DK-LF-Z datasheet Monolithic Power Systems MP8110DK-LF-Z 40V precision high-side current sense amplifier MP8110 8-MSOP current sense IC MP8110 1V output 5A current sensing MP8110DK-LF-Z price where to buy MP8110DK-LF-Z MP8110DK-LF-Z lead time MP8110DK-LF-Z drop-in replacement MP8110 pinout high-side current sensing 40V rail

Verwandte Bauteile & Begriffe

Monolithic Power Systems Inc. MP8110DK-LF-Z MP8110 EV8110DS-00A precision high-side current-sense amplifier current-sense amplifier instrumentation amplifier analog mixed-signal IC semiconductor high-side current sensing sense resistor Kelvin connection 2.5 V to 40 V 17 µA 1 V output 5 A load current 0.2 V/A 8-MSOP MSOP package family surface-mount package SMD RoHS REACH AEC-Q100
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert