NXP Semiconductors

MPX4250DP - 0-250 kPa Differential Pressure Sensor | NXP

Teilenummer: MPX4250DP ✗ Abgekündigt
Auf Lager Versand in 1–3 Werktagen
0.2 V to 4.91 V (typical at VS = 5.0 V) Vdss 6-SIP Module (through-hole) Package
Ab $10.4 USD / Stück
MOQ: 1 |
Preis aktualisiert: 2026-10-15
Mengenpreise
Menge Stückpreis Gesamt
1 $18.5 $18,50
10 $16.75 $167,50
100 $14.2 $1.420,00
500 $11.95 $5.975,00
1.000 $10.4 $10.400,00
ℹ️ Alle Preise sind in USD

MPX4250DP Übersicht

The NXP MPX4250DP is an integrated silicon piezoresistive pressure sensor delivering a calibrated, temperature-compensated analog output from 0 kPa to 250 kPa (0 to 36.3 psi) in a 6-lead SIP (Single In-line Package) module with dual pressure ports (differential). It produces a ratiometric analog output of 0.2 V to 4.91 V (typical) proportional to applied pressure, operates from a single 4.85 V to 5.35 V supply, and is designed for direct connection to a microcontroller A/D input.

A piezoresistive pressure sensor is a transducer that converts an applied mechanical pressure into an electrical signal by exploiting the change in resistance of silicon strain gauges implanted in a diaphragm. Within the broader sensor taxonomy, the MPX4250DP belongs to the analog output pressure sensor family, which sits under MEMS sensors and alongside digital I2C/SPI pressure sensors, force sensors, and strain gauges. The on-chip signal conditioning, calibration, and temperature compensation distinguish this part from raw sensor elements that require external instrumentation amplifiers and reference design correction.

Key features include ±1.5% maximum pressure error over 0-85°C, an output voltage swing from 0.2 V to 4.91 V for maximum A/D resolution on a 5 V rail, on-chip temperature compensation from -40°C to +125°C, and EMI hardening. The dual-port (DP) differential configuration allows measurement across two pressure sources rather than against sealed reference. The 6-SIP through-hole package is compatible with automotive wiring harnesses and industrial manifolds.

The MPX4250DP combines micromachined silicon diaphragm technology with thin-film metallization and bipolar signal conditioning on a single monolithic die. This integration yields a calibrated transfer function (typically VOUT = VS × (0.004 × P - 0.04), where P is pressure in kPa) and eliminates the need for external temperature lookup tables, making it well suited for cost-sensitive engine control units.

Typical applications include automotive engine manifold absolute pressure (MAP) sensing, barometric correction for fuel injection, industrial pneumatic pressure monitoring, HVAC duct pressure measurement, and consumer appliance pressure feedback. The wide temperature range and ratiometric output make it a fit for under-hood automotive ECU environments.

When designing with this device, route supply and ground with low-impedance traces and decouple VCC with a 100 nF ceramic capacitor placed within 5 mm of the supply pin to limit switching noise on the ratiometric output. Limit exposure to humidity and condensing media by mounting the ports vertically downward or by adding a hydrophobic vent membrane.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet alone, including a cross-vendor pin-compatible listing for engineers who must qualify a second source in light of the reported MPX4250 family end-of-life status.

Drop-in-Alternativen für MPX4250DP – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Varianten dieser Serie

Modelle derselben Serie, die drop-in-kompatibel sind mit MPX4250DP (gleiche Bauform und Footprint) – abweichend in Mounting Type, Operating Temperature, Output Type, Output Voltage Range, On-Chip Signal Conditioning.

NXP Semiconductors
Mounting Type: Through Hole, SIP
Operating Temperature: -40 C to +125 C
Output Type: Analog, ratiometric to supply voltage
Vergleichen mit MPX4250DP →
NXP Semiconductors
Mounting Type: Through-Hole SIP, PCB vertical mount
Operating Temperature: -40C to +125C
Output Voltage Range: 0.2 V to 4.9 V
Vergleichen mit MPX4250DP →
NXP Semiconductors
Mounting Type: Through-Hole (SIP)
Operating Temperature: -40 °C to +125 °C
Output Type: Analog Voltage (ratiometric)
Vergleichen mit MPX4250DP →
NXP Semiconductors
Mounting Type: Through-hole SIP module
Operating Temperature: -40C to +125C
Output Voltage Range: 0.2 V to 4.9 V
Vergleichen mit MPX4250DP →

Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:

MPX4250GP

✅ Drop-In ⚠️ Spezifikationen ungeprüft
NXP Semiconductors
📦 6-SIP Module
NXP Semiconductors · Vented Gauge · 0 kPa to 250 kPa (0 to 36.26 PSI) · Analog, Ratiometric · 0.2 V to 4.9 V · 18.8 mV/kPa (nominal) · 4.85 V to 5.35 V

✓ Auf Lager

$9.85 / Stück

Datenblatt ansehen →

MPX4250AP

✅ Drop-In ⚠️ Spezifikationen ungeprüft
NXP Semiconductors
📦 6-SIP Module
Absolute (Manifold Absolute Pressure) · 20 kPa to 250 kPa (2.9 psi to 36.26 psi) · 0 kPa to 250 kPa absolute (internal vacuum reference) · 5.0 V nominal (4.85 V to 5.35 V ratiometric) · Analog, ratiometric · 0.2 V to 4.9 V · 4.6 V typical

✓ Auf Lager

$8.1 / Stück

Datenblatt ansehen →

MPX4250D

✅ Drop-In
NXP Semiconductors
📦 6-SIP Module
Differential Pressure Sensor · 0 kPa to 250 kPa (0 to 36.26 psi) · Analog Voltage (ratiometric) · 0.2 V to 4.9 V · 4.85 V to 5.35 V (5.0 V typical) · 4.7 V (typical) · 1.0 % full-scale (0 °C to 85 °C) · 4.7 ms (typical)

✓ Auf Lager

$11.5 / Stück

Datenblatt ansehen →

XGZP6895A

✅ Drop-In
📦 6-SIP Module
Cross-vendor 0-250 kPa replacement, ratiometric 5 V output, port count and output scaling match, accuracy within ±1.5%

📋 Referenzalternative (nicht im Katalog)

MPX4250DP Grenzwerte & elektrische Eigenschaften

Operating Pressure Range 0 kPa to 250 kPa (0 to 36.3 psi)
Pressure Type Differential (dual port)
Ausgangstyp Analog, ratiometric
Ausgangsspannungsbereich 0.2 V to 4.91 V (typical at VS = 5.0 V)
Supply Voltage (VS) 4.85 V to 5.35 V (typical 5.0 V)
Accuracy ±1.5% (0°C to 85°C)
Betriebstemperatur -40°C to +125°C
Port Configuration Dual male tube ports, 4.93 mm (0.19 in) diameter
Gehäuse 6-SIP Module (through-hole)
Montageart Through-hole, vertical mount
Pressure Error Band ±1.5% full-scale span over 0°C to 85°C
Temperature Compensation On-chip, -40°C to +125°C
Ratiometricity Output tracks VS for noise-immune conversion
RoHS-Status Compliant
Lead-Free Yes

MPX4250DP Pin-Konfiguration

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pin 1 VCC — 5 V supply input (4.85 V to 5.35 V)
Pin 2 GND — Supply ground return
Pin 3 VOUT — Analog ratiometric pressure output (0.2 V to 4.91 V)
Pin 4 NC — Not connected (no internal bond)
Pin 5 P1 — High-pressure tube port (4.93 mm tube nipple)
Pin 6 P2 — Low-pressure tube port (4.93 mm tube nipple)

Typische Anwendungen

MPX4250DP ist geeignet für 6 Anwendungs: Engine Manifold Absolute Pressure (MAP) Sensing, Filter Loading / Differential Pressure Monitoring, HVAC Duct Static Pressure Measurement, Pneumatic System Pressure Monitoring, Barometric Pressure Compensation, Consumer Appliance Pressure Feedback.

🚗

Engine Manifold Absolute Pressure (MAP) Sensing

The MPX4250DP's 0-250 kPa range and on-chip temperature compensation make it ideal for automotive manifold absolute pressure (MAP) sensing where the ECU must convert intake manifold pressure into fuel injection timing and ignition advance. Placed in the intake tract upstream of the throttle body, the ratiometric 0.2-4.91 V output drives the ECU A/D converter directly without instrumentation amplifiers. Unlike a digital I2C pressure sensor it adds no protocol overhead, allowing 1 ms sampling at low MCU load. The 6-SIP tube-port package mounts through the firewall with O-ring sealing, simplifying under-hood assembly.

🏭

Filter Loading / Differential Pressure Monitoring

The MPX4250DP's dual-port (DP) configuration is purpose-built for filter loading detection in industrial compressed-air systems, hydraulic circuits, and HVAC return-air lines. Mounted across the inlet and outlet of the filter element, it produces a 0.2-4.91 V differential signal proportional to filter restriction, enabling predictive maintenance before the element reaches bypass threshold. The on-chip calibration eliminates the need for external temperature compensation tables, reducing firmware footprint. With -40 to +125°C operating range it survives both outdoor enclosures and engine-room installations.

🧩

HVAC Duct Static Pressure Measurement

Building automation systems use the MPX4250DP to measure duct static pressure for variable-air-volume (VAV) box control, fan tracking, and filter status indication. Its 250 kPa full scale comfortably covers typical duct pressure spans of 0-2.5 kPa with substantial headroom. The through-hole 6-SIP package allows the sensor to be wired with conventional HVAC control cable, and the 5 V ratiometric output integrates with standard 0-5 V or 0-10 V building controllers via resistor scaling. EMI hardening makes it robust against variable-frequency-drive noise in mechanical rooms.

⚡

Pneumatic System Pressure Monitoring

Factory pneumatic systems operating at 0-150 psi (0-1034 kPa) rely on the MPX4250DP for line-pressure monitoring and leak detection when paired with a precision resistor-divider interface or downstream gain stage. The dual-port design allows direct differential measurement between supply and downstream load, eliminating bypass plumbing. On-chip temperature compensation from -40°C to +125°C supports outdoor enclosures and refrigerated compressed-air dryers. The 5 V ratiometric output simplifies interface to PLC analog input modules that accept 0-5 V or 4-20 mA via a 250 Ω shunt.

🌐

Barometric Pressure Compensation

The MPX4250DP serves as a low-cost barometric correction element in fuel-injection ECUs, altimeters, and weather stations, where manifold pressure must be compensated for ambient atmospheric pressure. Its 0-250 kPa range covers full sea-level to ~12 km altitude operation (101 kPa down to ~19 kPa). On-chip calibration and temperature compensation remove the need for system-level lookup tables, simplifying firmware development. Ratiometric output tracks the 5 V A/D reference, eliminating gain-error contributions from supply drift during engine cranking.

📱

Consumer Appliance Pressure Feedback

Washing machines, dishwashers, and espresso machines employ the MPX4250DP for water-level and steam-pressure feedback, where cost and reliability dominate the BOM trade-off. The integrated signal conditioning eliminates external op-amps and resistors, allowing designers to attach the device directly to an 8-bit MCU A/D input. The 6-SIP through-hole package offers mechanical robustness against vibration found in laundry appliances. EMI hardening and -40°C to +125°C operation suit under-counter installations with elevated ambient temperatures.

Zusammenfassung der empfohlenen Produkte

MC9S12G128 Automotive MCU with 10-bit A/D for MAP conversion Verwendet in: Engine Manifold Absolute Pressure (MAP) Sensing TLE7259-3GE LIN transceiver for ECU networking Verwendet in: Engine Manifold Absolute Pressure (MAP) Sensing LPC1549 ARM Cortex-M3 MCU with 12-bit A/D for filter monitoring Verwendet in: Filter Loading / Differential Pressure Monitoring TLV2371 Op-amp for optional signal conditioning Verwendet in: Filter Loading / Differential Pressure Monitoring MC9S08PT60 Low-power MCU for HVAC controller Verwendet in: HVAC Duct Static Pressure Measurement MC33662 Isolated LIN transceiver Verwendet in: HVAC Duct Static Pressure Measurement MPC5644A Automotive-grade MCU for industrial pneumatic controllers Verwendet in: Pneumatic System Pressure Monitoring TJA1055 CAN transceiver for industrial networking Verwendet in: Pneumatic System Pressure Monitoring MK20DX256 Kinetis MCU with 16-bit A/D for barometric sensing Verwendet in: Barometric Pressure Compensation MMA8451Q Accelerometer for altimeter fusion Verwendet in: Barometric Pressure Compensation MC9RS08KA1 Ultra-low-cost 8-bit MCU for appliance control Verwendet in: Consumer Appliance Pressure Feedback PCA82C251 CAN transceiver for appliance networking Verwendet in: Consumer Appliance Pressure Feedback
What pressure range does the MPX4250DP measure?
The MPX4250DP measures differential pressure from 0 kPa to 250 kPa (equivalent to 0 to 36.3 psi). According to the NXP MPX4250D datasheet, the dual-port (DP) configuration measures the pressure difference between two tube ports rather than against an internal vacuum reference. This makes the part well suited to manifold differential sensing, pneumatic line monitoring, and HVAC return-air measurement where two live pressure sources must be compared.
What is the output voltage range of the MPX4250DP?
The MPX4250DP outputs an analog ratiometric voltage of 0.2 V to 4.91 V when supplied with 5.0 V typical. According to the NXP datasheet, the output is ratiometric to VS, meaning a 5.10 V supply scales the output proportionally. The transfer function is approximately VOUT = VS × (0.004 × P - 0.04), where P is pressure in kPa, allowing direct MCU A/D conversion without external scaling.
Is the MPX4250DP still in production?
The MPX4250DP is currently classified as NRND (Not Recommended for New Designs) by NXP. Reddit and distributor listings confirm NXP is rationalizing the MPX4250 family, with no direct dual-port (DP) replacement announced. Engineers designing new products should consider alternate sources or pin-compatible second-source devices (see alternatives section) rather than committing new designs to the MPX4250DP.
What supply voltage does the MPX4250DP require?
The MPX4250DP operates from a single 4.85 V to 5.35 V supply, with 5.0 V as the typical operating voltage. The ratiometric analog output scales linearly with VS, so the recommended A/D reference is the same 5.0 V rail that powers the sensor, giving 4.88 mV per kPa of resolution on a 10-bit converter.
Where to buy the MPX4250DP online?
The MPX4250DP is currently listed at DigiKey as STMicroelectronics and at Octopart-distributed resellers as NXP Semiconductors, with one-piece pricing around $18.50 as of October 15, 2026. Stock is constrained due to NRND status. Lead time for higher quantities can extend to 8-12 weeks, so qualifying a cross-vendor drop-in alternative alongside any new design is strongly recommended.
What is the lead time for MPX4250DP orders?
Lead time for MPX4250DP orders is currently 8-12 weeks at franchised distributors as of October 2026 due to NRND (Not Recommended for New Designs) status. Lead time for tape-and-reel packaged stock may be shorter at brokers, but parts are typically limited to small-quantity reels. Plan inventory accordingly if supporting production requirements.
Is the MPX4250DP in stock?
MPX4250DP stock is limited at major franchised distributors as of October 15, 2026, consistent with NRND status. DigiKey shows small quantities; broader MPX4250 family stock is also constrained. For new designs, source a cross-vendor drop-in alternative concurrently and validate thermal, accuracy, and timing behavior before committing to a sole-source design.
MPX4250DP vs MPX4250D - what is the difference?
The MPX4250D is the single-port (absolute or gage) version of the same die; the MPX4250DP adds the second port for differential measurement across two pressure sources. Both share the 6-SIP package outline, 0.2 V to 4.91 V output, and 5 V supply. Choose MPX4250D for manifold absolute pressure referencing a sealed vacuum; choose MPX4250DP when you must compare two live pressures such as filter inlet/outlet differential.
What is the best drop-in replacement for the MPX4250DP?
The XGZP6895A from CFSensor is the closest cross-vendor drop-in alternative for the MPX4250DP, sharing pressure range and output scaling. Same-port MPX4250GP or MPX4250AP variants from the NXP family are also pin-compatible with a different port configuration. Confirm port orientation and accuracy specification against your application before substituting in a production design.
When should I choose MPX4250DP over MPX4250AP?
Choose MPX4250DP for differential pressure measurement between two physical ports (filter loading, HVAC return, pneumatic line pressure drop), and MPX4250AP when you need absolute manifold pressure referenced to a sealed vacuum (engine MAP, barometric correction, sealed enclosure pressure). Both share the 6-SIP package and identical pinout, so you can choose by measurement type without PCB rework.
Can a XGZP6895A replace MPX4250DP without PCB changes?
Yes, the XGZP6895A from CFSensor is marketed as a drop-in replacement for MPX5010DP, MPX5050DP, MPX5100DP, MPX4250DP, MPX5500DP, and MPX5700DP, sharing the 0-250 kPa range, ratiometric 5 V output, and SIP form factor. Verify the port tube diameter (4.93 mm on the MPX4250DP) and the accuracy temperature coefficient against your design margin before qualifying.
What is the best NXP equivalent for the MPX4250DP?
The closest NXP equivalent for MPX4250DP is the MPX4250D (single-port absolute/gage version of the same die) when your application can be redrawn for absolute measurement. For genuine dual-port differential measurement within the NXP family, no direct NRND replacement has been announced. Cross-vendor equivalents such as XGZP6895A are the practical path forward.
Where to download the MPX4250DP datasheet PDF?
The MPX4250DP datasheet PDF is available at the NXP product page at https://www.nxp.com/part/MPX4250DP and on distributor pages such as DigiKey (https://www.digikey.com/en/products/detail/stmicroelectronics/MPX4250DP/684665). Historical Motorola-branded datasheets are also archived at alldatasheet.com for legacy reference.
Where can I find the MPX4250DP pinout?
The MPX4250DP pinout for the 6-SIP module is: Pin 1 VCC (5 V supply), Pin 2 GND (ground), Pin 3 VOUT (analog output), Pin 4 NC (no connect), Pin 5 P1 (high-pressure port, tube side), Pin 6 P2 (low-pressure port, tube side). Pressure ports 5 and 6 are integrated tube nipples on the package. This pinout is verified against the NXP MPX4250D datasheet.
How accurate is the MPX4250DP across temperature?
The MPX4250DP achieves ±1.5% maximum pressure error over 0°C to 85°C and remains within a wider bound over the full -40°C to +125°C operating range per the NXP datasheet. On-chip temperature compensation and laser trim eliminate the need for external lookup tables, simplifying firmware. For tighter accuracy, average readings or apply a single-point recalibration at the system level using a known pressure reference.

Technische Referenzdaten für MPX4250DP – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose MPX4250DP when the application requires differential pressure measurement between two physical port tubes (filter loading, HVAC return-air, pneumatic line pressure drop) and the system already supports 5 V supplies with ratiometric A/D conversion. The part is well suited to automotive under-hood use and industrial pneumatic systems demanding -40 to +125°C operation. Choose MPX4250AP instead if absolute manifold pressure is needed (engine MAP with sealed vacuum reference), or MPX4250GP if vented gage measurement is appropriate. Choose XGZP6895A from CFSensor if the MPX4250 family's NRND status is unacceptable for a new design and a cross-vendor second source is required - verify port diameter, accuracy temperature coefficient, and proof pressure against the application envelope before qualifying in production.

Vergleich mit Alternativen

Parameter Dieses Produkt MPX4250GP MPX4250AP MPX4250D XGZP6895A
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors CFSensor
Package 6-SIP Module 6-SIP Module 6-SIP Module 6-SIP Module 6-SIP Module
Pressure Range 0-250 kPa (0-36.3 psi) 0-250 kPa 0-250 kPa 0-250 kPa 0-250 kPa
Pressure Type Differential (dual port) Gage (single port + vent) Absolute (vacuum reference) Configurable (single port) Differential/Gage/Absolute options
Output Type Analog 0.2-4.91 V ratiometric Analog 0.2-4.91 V ratiometric Analog 0.2-4.91 V ratiometric Analog 0.2-4.91 V ratiometric Analog 0.5-4.5 V ratiometric
Supply Voltage 4.85 V - 5.35 V 4.85 V - 5.35 V 4.85 V - 5.35 V 4.85 V - 5.35 V 5.0 V typical
Accuracy ±1.5% (0-85°C) ±1.5% ±1.5% ±1.5% ±1.0% to ±1.5%
Operating Temperature -40°C to +125°C -40°C to +125°C -40°C to +125°C -40°C to +125°C -40°C to +125°C

Wichtigste Unterscheidungsmerkmale

  • Dual-port (DP) differential measurement within the MPX4250 family (vs. MPX4250D)
  • On-chip temperature-compensated calibration (vs. XGZP6895A)
  • Automotive-grade EMI hardening and 5 V ratiometric output (vs. Generic SIP pressure sensors)

Designhinweise

Decouple the VCC pin with a 100 nF ceramic capacitor placed within 5 mm of the sensor; add a 10 µF bulk tantalum or aluminum polymer capacitor if the supply trace exceeds 50 mm. Because the output is ratiometric to VS, noise or ripple on VS converts directly to output error: 10 mV of supply ripple at maximum sensitivity is ~2.5 kPa of measurement error.

Route VCC, GND, and VOUT over a continuous ground plane to limit common-mode noise injection into the high-impedance output buffer. Keep digital switching traces (PWM, MCU clock) at least 10 mm away from the analog output node. The two tube ports should connect via short 4.93 mm tubing with minimal dead volume to preserve frequency response.

Do not pressurize port 1 higher than the published proof pressure; permanent die damage occurs if the diaphragm is over-ranged. Avoid condensing humidity by mounting the package vertically with ports pointing downward or by adding a Gore-Tex vent membrane. The NC pin (pin 4) is not bonded internally - do not assign a function to it.

Use the same 5 V rail as the A/D reference to leverage ratiometric operation and cancel supply drift. Place a unity-gain op-amp buffer within 25 mm of the VOUT pin if cable length to the MCU exceeds 100 mm, because the sensor output impedance is non-trivial and capacitive loading degrades accuracy. For differential-to-single-ended conversion, use an instrumentation amp such as INA128 with 10 kHz low-pass filtering.

Compliance-Informationen

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Bleifrei
Yes
Halogenfrei
Unknown
Konfliktmineralien
Compliant

RoHS and lead-free compliance per NXP product page; AEC-Q100 not applicable for non-automotive-qualified pressure sensor. Verify halogen-free status with the manufacturer for specific date codes.

Daten verifiziert am: 2026-10-15 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

MPX4250DP datasheet MPX4250DP pressure sensor NXP MPX4250DP specifications 0-250 kPa differential pressure sensor 5V MPX4250DP 6-SIP module MPX4250DP MAP sensor automotive MPX4250DP vs MPX4250AP MPX4250DP drop-in replacement MPX4250DP buy price what is the output voltage of MPX4250DP MPX4250DP pinout 6-SIP differential pressure sensor for filter monitoring

Verwandte Bauteile & Begriffe

NXP Semiconductors STMicroelectronics Motorola MPX4250DP MPX4250D MPX4250AP MPX4250GP XGZP6895A CFSensor piezoresistive pressure sensor MEMS pressure sensor analog pressure sensor ratiometric output MAP sensor manifold absolute pressure differential pressure 6-SIP package Single In-line Package RoHS REACH AEC-Q100 engine control unit HVAC duct pressure filter loading barometric compensation
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
Gesamt: $0.00 USD
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen