MAX6675ISA+ vs MAX31855KASA+ Comparación
Comparación detallada lado a lado de MAX6675ISA+ por Maxim Integrated y MAX31855KASA+ por Analog Devices. Compare las especificaciones clave, los parámetros eléctricos, el encapsulado, el estado del ciclo de vida, los precios y la disponibilidad para determinar el mejor componente para los requisitos de su diseño.
Maxim Integrated
MAX6675ISA+ - K-Thermocouple-to-Digital, 0-1024°C, SPI | Maxim
MAX6675ISA+ ✓ ActivoAnalog Devices
MAX31855KASA+ - K-Type Thermocouple-to-Digital Converter | Maxim Integrated
MAX31855KASA+ ✓ ActivoComparación de especificaciones
| Parámetro | MAX6675ISA+ | MAX31855KASA+ |
|---|---|---|
| Marca | Maxim Integrated | Analog Devices |
| Categoría | Temperature Sensors | Temperature Sensors |
| Estado del ciclo de vida | Activo | Activo |
| Estado del stock | In Stock | In Stock |
| Precio unitario (USD) | $6,55 | $4,20 |
| Función | Thermocouple-to-Digital Converter (Type-K) | Thermocouple-to-Digital Converter with Cold-Junction Compensation |
| Thermocouple Type | K-Type | — |
| Temperature Range | 0 °C to +1024 °C | — |
| Resolución | 0.25 °C (12-bit) | — |
| Thermocouple Accuracy | 8 LSB (0°C to +700°C) | plus/minus 2 degC |
| Tensión de alimentación | 3.0 V to 5.5 V | — |
| Supply Current (typical) | 1.5 mA | — |
| Interfaz | SPI-compatible (read-only, 3-wire) | — |
| Cold-Junction Compensation | Built-in | On-chip, integrated |
| Conversion Method | On-demand, single per CS cycle | — |
| Thermocouple Disconnect Detection | Yes (via pull-up) | — |
| Operating Temperature (device) | -20 °C to +85 °C | — |
| Encapsulado | 8-pin SOIC (ISA / SO-8) | 8-pin SOIC (NSOIC), 3.90 mm body |
| Tipo de montaje | Surface Mount | Surface Mount |
| Estado RoHS | Compliant | Compliant (per distributor listing) |
| Nivel MSL | 1 (unlimited floor life) | [DATA_NEEDED: MSL rating] |
| Supported Thermocouple Type | — | K (K-type probe input) |
| Output Resolution | — | 14-bit signed (0.25 degC per LSB) |
| Output Interface | — | SPI-compatible, read-only |
| Thermocouple Temperature Range | — | -270 degC to +1800 degC |
| Open-Thermocouple Detection | — | Yes (fault register) |
| Supply Voltage (VDD) | — | 3.0 V to 3.6 V (2.7 V min per datasheet) |
| Corriente de alimentación | — | [DATA_NEEDED: typical operating current] |
| Temperatura de funcionamiento | — | -40 degC to +125 degC |