AD7578KN - 12-Bit 100us SAR ADC | Analog Devices
N.º de pieza: AD7578KN ✗ Fin de vidaAD7578KN Descripción general
A successive-approximation ADC, or SAR ADC, converts an analog voltage by progressively comparing the input against a generated reference and testing successive binary-weighted voltages. Within the ADC and data-converter hierarchy, the AD7578KN is a medium-speed CMOS data-converter IC intended for instrumentation, industrial measurement, and microprocessor-controlled acquisition systems. It offers a conventional external-reference interface and standard control signals for connection to digital processors.
Principal features include 12-bit resolution, a single analog input, 100 us conversion time, CMOS construction, and compatibility with a +5 V reference. The auto-zero mechanism reduces offset error before each conversion, while the 24-pin through-hole PDIP package supports conventional PCB assembly and prototype development. The manufacturer identifies the device as a complete converter requiring only a few passive components and an external voltage reference.
The AD7578KN uses the successive-approximation technique to determine each 12-bit result. Its digital interface uses standard chip-select and control signals intended for straightforward interfacing with microprocessors and other host logic. Because the architecture is a SAR converter, conversion timing is deterministic and does not require a pipeline delay. This makes the device useful when the host needs a defined acquisition interval, explicit start-of-conversion control, and predictable acquisition of a single analog channel.
Typical applications include process-control instrumentation, laboratory measurement equipment, industrial data acquisition, digital panel meters, and embedded control systems. It is particularly appropriate when a 12-bit result is sufficient for monitoring temperature, pressure, position, or slow-changing process signals and when legacy 24-pin through-hole PCB designs require a maintained or drop-in-compatible upgrade path.
The primary design consideration is reference quality. The analog input range is 0 V to +5 V with a +5 V reference, so the reference must be stable and appropriately decoupled for the required measurement accuracy. Place the reference and input components close to the device, observe the specified acquisition and conversion timing, and use clean analog routing to minimize errors that cannot be corrected by the converter's 12-bit resolution.
This page combines the AD7578KN's core electrical characteristics, verified package details, pin-compatible alternatives, interface guidance, and practical selection criteria into one engineering reference. It also distinguishes lifecycle considerations and replacement options so engineers can assess a design change before modifying an existing 24-pin analog-measurement board.
Alternativas directas para AD7578KN — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
AD7578KNZ
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
AD7578TQ/883B
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
AD7578BQ
✅ Sustitución directaConsulte el precio
Ver hoja de datos →MX7578KN+
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
AD7572JN12
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
AD7578KN Valores máximos y características eléctricas
| ADC Resolution | 12 bit |
| Number of Analog Inputs | 1 input |
| Conversion Architecture | Successive approximation (SAR) |
| Conversion Time | 100 us |
| Process Technology | CMOS |
| Analog Input Voltage Range | 0 V to +5 V with a +5 V reference |
| Tensión de referencia | +5 V |
| System Offset Voltage | Typically less than 100 uV |
| Encapsulado | 24-pin PDIP |
| Tipo de montaje | Through-hole |
| Number of Terminals | 24 terminals |
| Package Shape | Rectangular DIP |
| Temperature Grade | Commercial |
| Host Interface | Microprocessor interface using standard control signals |
| Required External Components | A few passive components and a voltage reference |
| Analog Input Type | Single-ended analog input |
| Conversion Start Control | External control signal |
Guía de configuración de pines de AD7578KN rectangular dip
Configuración de pines para AD7578KN (encapsulado rectangular dip). Este componente analógico presenta pines de entrada, salida y alimentación. Consulte la hoja de datos del fabricante para conocer las configuraciones de los pines de ajuste de offset, compensación y habilitación. Ideal para circuitos de acondicionamiento de señal y amplificadores.
No hay datos detallados de patillaje disponibles para AD7578KN.
Consulte la hoja de datos para ver la configuración completa de patillas.
Aplicaciones típicas
AD7578KN es adecuado para 6 aplicacións: Industrial Process Measurement, Laboratory Data Acquisition, Digital Panel Meter, Position and Displacement Sensing, Temperature and Pressure Monitoring, Legacy Industrial Control Upgrade.
Industrial Process Measurement
The AD7578KN suits process-control systems that monitor one slowly changing analog variable through a conditioned sensor interface. Its 12-bit resolution provides 4096 discrete code levels, while the documented 100 us conversion time allows frequent measurements without a complex pipeline. The 0 V to +5 V input range works directly with sensor conditioners that output in that interval. A stable +5 V reference is required for predictable code accuracy. The 24-pin PDIP format is useful for industrial legacy or maintenance boards where through-hole assembly, inspection, and manual replacement are important.
Recomendado
Laboratory Data Acquisition
The AD7578KN can serve as the measurement front end for a laboratory instrument that requires repeatable single-channel readings rather than high-speed waveform capture. The SAR architecture provides a defined 100 us conversion time, making acquisition timing straightforward for a host processor. Its auto-zero cycle typically limits system offset to less than 100 uV, which helps preserve measurement accuracy in low-level analog systems. Use a quiet +5 V reference, short analog traces, and suitable input conditioning to prevent board noise or source impedance from undermining the converter's 12-bit resolution.
Recomendado
Digital Panel Meter
A digital panel meter can use the AD7578KN to convert a scaled voltage from a sensor or control signal into a 12-bit digital value for display and alarm processing. The single analog input keeps the circuit straightforward when the instrument monitors one process variable. The 100 us conversion time is short for typical human-response panel measurements, and the 0 V to +5 V input range matches many conditioned outputs. The commercial 24-pin PDIP package also simplifies installation on meter-controller boards designed for through-hole components.
Recomendado
Position and Displacement Sensing
The AD7578KN can digitize the output of a linear potentiometer, LVDT conditioner, resistive position sensor, or other displacement element that produces an analog voltage. Its 12-bit resolution is appropriate for coarse position display, limit monitoring, and basic closed-loop positioning where 4096 codes provide adequate resolution. The 100 us conversion rate allows the controller to sample position frequently, while auto-zero reduces fixed offset that could otherwise shift the reconstructed position. The sensor conditioner should keep its output inside the documented 0 V to +5 V input range.
Recomendado
Temperature and Pressure Monitoring
The AD7578KN is applicable to temperature, pressure, and level monitoring systems whose sensors use analog signal conditioners. A bridge amplifier or transmitter can convert the physical quantity into 0 V to +5 V, after which the ADC supplies a 12-bit code to a controller. The 100 us conversion time supports rapid periodic sampling, and the typical auto-zero offset below 100 uV reduces systematic error in slow-changing measurements. Reference stability and sensor-conditioning accuracy must remain aligned with the 12-bit conversion resolution.
Recomendado
Legacy Industrial Control Upgrade
The AD7578KN is particularly relevant to maintenance of an existing 24-pin industrial controller whose original converter has reached the end of its practical service life. Because the AD7578KN uses a conventional 24-pin PDIP package and standard microprocessor control signals, it can support targeted board repair when the original AD7578 interface is retained. Designers should still compare pin assignments, reference voltage, acquisition timing, and logic levels against the AD7578 Data Sheet, Rev. B. This approach is preferable to a complete control-system redesign when the rest of the equipment remains serviceable.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para AD7578KN — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | AD7578KNZ | AD7578TQ/883B | AD7578BQ | MX7578KN+ | AD7572JN12 |
|---|---|---|---|---|---|---|
| Package | 24-PDIP | 24-PDIP | 24-pin through-hole package | 24-pin through-hole package | 24-PDIP | 24-PDIP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Maxim Integrated | Analog Devices |
| ADC Resolution | 12 bit | 12 bit | 12 bit | 12 bit | 12 bit | 12 bit |
| Conversion Architecture | Successive approximation (SAR) | Successive approximation (SAR) | Successive approximation (SAR) | Successive approximation (SAR) | Successive approximation (SAR) | Successive approximation (SAR) |
Diferenciadores clave
- Documented deterministic medium-speed conversion (frente a AD7572JN12)
- Single-input 12-bit SAR conversion (frente a MX7578KN+)
- Documented auto-zero offset behavior (frente a AD7578KNZ)
- Commercial 24-pin PDIP sourcing position (frente a AD7578TQ/883B)
Notas de diseño
Use the +5 V reference arrangement specified in the Analog Devices AD7578 Data Sheet, Rev. B, and decouple the reference close to the device. Reference error directly contributes to conversion-code error, so a nominally correct 5 V source is not sufficient if its noise or drift is excessive for the intended 12-bit measurement. Select reference and bypass components according to the manufacturer guidance and verify temperature behavior across the full operating range.
Keep the analog input path short and place any input protection, filtering, or conditioning components near the AD7578KN. Route the analog input away from digital clocks, relay contacts, power-converter nodes, and fast-return-current paths. The device has only 12-bit resolution, so poor grounding and source-impedance-related errors can consume meaningful accuracy even when the converter itself is operating correctly.
Do not treat the AD7578 family as a drop-in replacement platform without checking the exact suffix, package construction, grade, reference configuration, and acquisition timing. AD7578KNZ, AD7578TQ/883B, and AD7578BQ have different ordering and qualification meanings even though comparison material identifies package-consistent migration paths. Validate the complete manufacturer's pin table and timing diagram before releasing a replacement to production.
Información de cumplimiento
The manufacturer identifies the AD7578 as not recommended for new designs. Specific environmental and material-compliance declarations for AD7578KN are not established in the available manufacturer-page excerpt.