N.º de pieza: AD7714YN ✓ ActivoAD7714YN Descripción general
An ADC converts an analog input into a digital numerical value. The AD7714 belongs to the signal-conditioning ADC category, combining input multiplexing, programmable gain, filtering, calibration, and conversion functions in one device. Its sigma-delta architecture is intended for precision measurements rather than high-speed waveform capture, supporting applications that require high resolution and narrow-band noise performance from low-level transducer signals.
Key features include 24-bit no missing codes, ±0.0015% accuracy, and low RMS noise of 140 nV. On-chip self-calibration removes zero-scale and full-scale errors, while endpoint errors and temperature-drift effects are reduced by the calibration system. The three differential inputs can be configured as five pseudo-differential channels, allowing one converter to serve multiple low-level sensing channels. The 500 µA operating current supports low-power measurement systems, and the 3 V/5 V supply flexibility helps accommodate both industrial and embedded designs.
The AD7714 uses a sigma-delta conversion technique and includes on-chip registers for controlling filter cutoff, input gain, channel selection, signal polarity, and calibration modes. The differential reference architecture helps reject common-mode noise when the reference and input circuitry are carefully designed. Its three-wire serial interface reduces interconnect count, which is useful in isolated systems and compact embedded equipment.
Typical applications include pressure and load-cell signal acquisition, temperature measurement, portable instrumentation, industrial process monitoring, and low-level sensor interfaces. The combination of five-channel capability, programmable gain, calibration, and a low-power serial interface makes the device suitable for systems where measurement accuracy and stable readings matter more than throughput.
Designers should follow the manufacturer datasheet for the complete pinout, reference-voltage limits, input common-mode range, gain settings, filter options, and recommended decoupling. Pay particular attention to input and reference grounding, source impedance, digital-interface timing, and calibration sequencing. A low-noise reference and careful PCB layout are important when the converter is used near the limits of its specified noise and accuracy performance.
Alternativas directas para AD7714YN — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
AD7714YNZ
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
AD7714ANZ-3
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
AD7714YN Valores máximos y características eléctricas
| Resolución | 24 bit |
| Conversion Rate | 1 ksps |
| Analog Inputs | 3 differential or 5 pseudo-differential inputs |
| Input Type | Differential and pseudo-differential analog inputs |
| Tensión de alimentación | 3 V to 5 V |
| Operating Current | 500 µA |
| Noise | 140 nV RMS |
| Accuracy | ±0.0015% |
| No Missing Codes | 24-bit no missing codes |
| Calibration | On-chip self-calibration |
| Reference Input | Differential reference input |
| Digital Interface | 3-wire serial interface |
| On-Chip Registers | Filter cutoff, input gain, channel selection, signal polarity, and calibration mode control |
| Conversion Architecture | Sigma-delta |
| Encapsulado | 24-pin PDIP |
| Tipo de montaje | Through-hole |
| Process Technology | CMOS |
| Manufacturer | Analog Devices |
Guía de configuración de pines de AD7714YN 24-pin pdip
Configuración de pines para AD7714YN (encapsulado 24-pin pdip). Este componente analógico presenta pines de entrada, salida y alimentación. Consulte la hoja de datos del fabricante para conocer las configuraciones de los pines de ajuste de offset, compensación y habilitación. Ideal para circuitos de acondicionamiento de señal y amplificadores.
No hay datos detallados de patillaje disponibles para AD7714YN.
Consulte la hoja de datos para ver la configuración completa de patillas.
Aplicaciones típicas
AD7714YN es adecuado para 6 aplicacións: Load-Cell Signal Conditioning, Pressure Transducer Interface, Portable Weighing Instrument, Industrial Process Monitoring, Temperature Measurement, Laboratory Instrumentation.
Load-Cell Signal Conditioning
The AD7714YN suits load-cell and bridge-transducer measurements because it accepts low-level differential inputs, provides programmable gain, and performs on-chip self-calibration. A 24-bit conversion result and 140 nV RMS noise specification support precise weight-force measurement when paired with a stable excitation and reference. The three-wire serial interface also keeps the connection to a controller compact, reducing board-space requirements in portable weighing equipment. Engineers should follow the manufacturer application circuit for input filtering, excitation routing, reference connections, and grounding because sensor lead resistance and bridge imbalance can otherwise reduce the practical system accuracy.
Recomendado
Pressure Transducer Interface
The AD7714YN can acquire low-level pressure-sensor signals with a 24-bit conversion result at up to 1 ksps. Its programmable gain, selectable digital filtering, differential reference input, and self-calibration help stabilize measurements in process-control and test systems. The five pseudo-differential input capability allows several sensing elements to share a converter when appropriate common-mode and source-impedance conditions are met. For reliable operation, keep sensitive analog routing away from digital clocks and serial lines, use a low-noise reference, and verify the input common-mode range against the chosen bridge or resistive sensor implementation.
Recomendado
Portable Weighing Instrument
The AD7714YN supports portable scales by combining 24-bit resolution, differential excitation measurement, programmable gain, and low 500 µA operating current in a 24-pin PDIP. Its three-wire serial interface reduces wiring to a display controller or embedded MCU, while self-calibration helps compensate zero-scale and full-scale errors. The sigma-delta architecture is well matched to slow-changing force signals rather than rapid vibration capture. For a battery-operated design, evaluate the complete power budget, select suitable low-noise reference and excitation components, and use filtering that balances response time against the required weight reading rate.
Recomendado
Industrial Process Monitoring
The AD7714YN is appropriate for low-level process variables when measurement resolution, calibration, and channel multiplexing are more important than high conversion throughput. Three differential inputs or five pseudo-differential inputs can monitor several sensor channels, while programmable gain accommodates different signal amplitudes. Its differential reference and digital filter support stable readings in multi-sensor equipment, and the 3 V/5 V operating range permits use in embedded industrial controllers. Use isolated or protected interface circuitry where required by the installation, and ensure the sensor signal remains inside the ADC input common-mode limits under every operating condition.
Recomendado
Temperature Measurement
The AD7714YN can digitize resistive or thermoresistive temperature sensors when the bridge excitation and reference network are designed for low noise. The 24-bit resolution and 140 nV RMS input-noise figure support fine temperature resolution over a restricted measurement range, while programmable gain accommodates low-level sensor outputs. On-chip self-calibration reduces systematic offset and scale error, and the 1 ksps maximum rate is sufficient for many thermal processes. Avoid using the converter for fast transient sensing without evaluating the digital-filter delay. For best results, use a stable excitation source, low-reference-impedance layout, and sensor-specific lead compensation.
Recomendado
Laboratory Instrumentation
The AD7714YN fits laboratory measurement instruments that require high-resolution digitizing of slow sensor outputs, such as bridge sensors, strain gauges, and precision dividers. Its 24-bit no-missing-code performance, ±0.0015% accuracy rating, programmable digital filtering, and differential reference input provide a strong foundation for repeatable readings. The three-wire serial interface connects readily to a microcontroller or DSP while limiting control-line count. Instrument performance will ultimately be set by reference accuracy, excitation stability, analog input noise, grounding, and calibration procedure. Use the manufacturer filter and calibration guidance to select the proper conversion mode for each measurement bandwidth.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para AD7714YN — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | AD7714YNZ | AD7714ANZ-3 |
|---|---|---|---|
| Package | 24-pin PDIP | 24-pin PDIP | 24-pin PDIP |
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Resolution | 24 bit | 24 bit | 24 bit |
| Conversion Rate | 1 ksps | 1 ksps | 1 ksps |
| Input Configuration | 3 differential or 5 pseudo-differential inputs | 3 differential or 5 pseudo-differential inputs | 3 differential or 5 pseudo-differential inputs |
| Supply Voltage | 3 V to 5 V | 3 V to 5 V | 3 V to 5 V |
| Process Technology | CMOS | CMOS | CMOS |
| Digital Interface | 3-wire serial interface | 3-wire serial interface | 3-wire serial interface |
| Lifecycle Status | Obsolete | Active | Obsolete |
Diferenciadores clave
- Active lifecycle option in the same 24-pin PDIP footprint (frente a AD7714YN)
- Five-channel measurement flexibility (frente a AD7714ANZ-3)
- Integrated calibration and filtering reduce external signal-chain complexity (frente a AD7714ANZ-3)
Notas de diseño
Route the differential input and reference traces as a closely matched pair, keep them away from digital clock and serial-interface traces, and provide a solid ground plane. Place input and reference filtering components near their corresponding pins. The 140 nV RMS noise rating cannot be realized reliably if leakage, ground currents, or switching-node coupling dominates the sensor signal.
Program the digital filter and output-data-rate settings according to the required signal bandwidth. Slow sensor signals benefit from additional digital averaging or filtering, while excessive filtering increases response latency. For multiplexed operation, allow each channel and the reference to settle before taking a measurement, following the manufacturer guidance for conversion timing and calibration.
Do not assume that a 24-bit converter automatically delivers 24-bit system accuracy. The excitation source, reference voltage, sensor lead resistance, input common-mode range, grounding, and PCB leakage all contribute to error. Use the on-chip self-calibration functions as directed by the Analog Devices datasheet and verify calibration mode, gain, polarity, and channel settings in firmware.
The AD7714YN operates from 3 V or 5 V with a stated 500 µA operating current. In low-power instruments, include the converter, reference, excitation source, controller, and interface levels in the complete power budget rather than sizing the battery from the ADC current alone. Select reference and excitation components with low noise and suitable current capability while maintaining the required accuracy and startup behavior.
Información de cumplimiento
Compliance information was not stated in the AD7714 product information. The AD7714 is an analog-to-digital converter rather than an automotive-qualified component, so AEC-Q100 is marked not applicable.