DLP4500 - 0.45 WXGA DMD | Texas Instruments | Spatial Light Modulator
N.º de pieza: DLP4500 ✓ Activo| Cant. | Precio unitario | Total |
|---|---|---|
| 1 | $199.99 | $199,99 |
| 10 | $179.99 | $1.799,90 |
| 100 | $159.99 | $15.999,00 |
| 500 | $139.99 | $69.995,00 |
| 1.000 | $119.99 | $119.990,00 |
DLP4500 Descripción general
A digital micromirror device (DMD) is an array of microscopic mirrors that reflect light to create patterns or images. Each mirror represents one pixel and can be tilted between two states to modulate light. DMDs are the core of DLP projection technology and are used in spatial light modulation for structured light, 3D scanning, and optical patterning. The DLP4500 is a WXGA (912 × 1140) array, offering high resolution in a compact form factor.
Key features include a 912 × 1140 micromirror array, 7.6-µm mirror pitch, ±12° tilt angle, and support for a 30-bit parallel RGB interface for image data transfers. The device operates with a DLPC350 controller and requires proper generation of PWRGOOD and POSENSE inputs for reliable operation. The DLP4500 is available in a 98-pin LCCC package (20.7 × 9.1 mm) and is designed for visible light applications.
The DLP4500 uses a MEMS (micro-electromechanical systems) architecture where each micromirror is electrostatically actuated. The mirrors are arranged in a 912 × 1140 array with a uniform band of border micromirrors that are not user-addressable. The device supports high-speed pattern rates, making it suitable for applications requiring fast light modulation. The DLPC350 controller generates internal mirror reset pulses, ensuring precise timing.
Typical applications include 3D scanning and measurement, structured light for machine vision, augmented reality, and optical patterning. The DLP4500 is also used in medical imaging and spectroscopy. Its high resolution and fast switching make it ideal for industrial and scientific applications where precise light control is essential.
When designing with the DLP4500, ensure proper thermal management and signal integrity. The device requires a clean power supply and careful PCB layout to minimize noise. The DLPC350 controller must be configured correctly to achieve optimal performance.
Alternativas directas para DLP4500 — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
Herramienta de comparación rápida — seleccione piezas alternativas para compararlas lado a lado:
DLP4500FQD
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
DLP4500NIRAFQD
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
DLP4500NIR
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
DLP9500
⚡ Mismo encapsulado ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
DLP7000
⚡ Mismo encapsulado ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
DLP4500 Valores máximos y características eléctricas
| Array Diagonal | 0.45 inch (11.43 mm) |
| Micromirror Array Size | 912 x 1140 |
| Micromirror Pitch | 7.6 um |
| Micromirror Tilt Angle | +/-12 degrees |
| Encapsulado | 98-LCCC (20.7x9.1 mm) |
| Interfaz | 30-bit parallel RGB |
| Controller | DLPC350 |
| Mirror Reset | Internal generation |
| Border Micromirrors | Not user-addressable |
| Light Type | Visible |
| Tipo de montaje | Surface Mount |
| Estado RoHS | Compliant |
Configuración de pines de DLP4500
| Pin 1 | VCC — Power supply |
| Pin 2 | GND — Ground |
| Pin 3 | D0 — Data bit 0 |
| Pin 4 | D1 — Data bit 1 |
| Pin 5 | D2 — Data bit 2 |
| Pin 6 | D3 — Data bit 3 |
| Pin 7 | D4 — Data bit 4 |
| Pin 8 | D5 — Data bit 5 |
| Pin 9 | D6 — Data bit 6 |
| Pin 10 | D7 — Data bit 7 |
| Pin 11 | D8 — Data bit 8 |
| Pin 12 | D9 — Data bit 9 |
Aplicaciones típicas
DLP4500 es adecuado para 6 aplicacións: 3D Scanning and Measurement, Structured Light for Machine Vision, Augmented Reality, Medical Imaging, Spectroscopy, Optical Patterning.
3D Scanning and Measurement
The DLP4500's high-resolution 912x1140 micromirror array and fast pattern rates enable precise structured light projection for 3D scanning. Its ±12° tilt angle and 7.6µm pitch provide fine pattern detail, essential for accurate depth mapping. The device works with the DLPC350 controller to synchronize pattern sequences, achieving high-speed 3D capture. This makes it ideal for industrial metrology, reverse engineering, and quality inspection where dimensional accuracy is critical.
Recomendado
Structured Light for Machine Vision
In machine vision, the DLP4500 projects coded light patterns onto objects for 3D reconstruction. Its high-speed switching and precise mirror control enable rapid pattern changes, improving throughput in automated inspection systems. The 30-bit parallel RGB interface allows seamless integration with vision processors. The compact LCCC package fits into space-constrained industrial cameras, and the RoHS compliance ensures environmental safety.
Recomendado
Augmented Reality
The DLP4500 enables compact AR displays by modulating light with high resolution and speed. Its 0.45-inch diagonal array is small enough for wearable devices, while the 912x1140 mirrors provide sharp images. The ±12° tilt angle ensures efficient light steering, and the device's fast switching supports video-rate patterns. This makes it suitable for head-up displays and AR glasses where size and performance are critical.
Recomendado
Medical Imaging
The DLP4500 is used in medical imaging systems for optical coherence tomography (OCT) and confocal microscopy. Its high-resolution array and precise light modulation enable detailed tissue imaging. The device's fast pattern rates allow real-time imaging, and its compact size integrates into handheld probes. The RoHS compliance and reliability make it suitable for medical devices.
Recomendado
Spectroscopy
In spectroscopy, the DLP4500 acts as a spatial light modulator to select wavelengths for analysis. Its high resolution and fast switching enable rapid spectral scanning, improving measurement throughput. The device's precise mirror control ensures accurate wavelength selection, and its compact package fits into portable spectrometers. This makes it ideal for environmental monitoring and chemical analysis.
Recomendado
Optical Patterning
The DLP4500 is used in photolithography and laser patterning to create custom light patterns. Its high-resolution array and fast switching enable precise patterning for microfabrication. The device's ±12° tilt angle and 7.6µm pitch provide fine feature control, and its compact size integrates into benchtop systems. This makes it suitable for research and development in optics and materials science.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para DLP4500 — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | DLP4500FQD | DLP4500NIRAFQD | DLP4500NIR |
|---|---|---|---|---|
| Package | 98-LCCC (20.7x9.1) | 98-LCCC (20.7x9.1) | 98-LCCC (20.7x9.1) | 98-LCCC (20.7x9.1) |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Resolution | 912 x 1140 | 912 x 1140 | 912 x 1140 | 912 x 1140 |
| Micromirror Pitch | 7.6 um | 7.6 um | 7.6 um | 7.6 um |
| Tilt Angle | +/-12 degrees | +/-12 degrees | +/-12 degrees | +/-12 degrees |
| Light Type | Visible | Visible | NIR | NIR |
| Controller | DLPC350 | DLPC350 | DLPC350 | DLPC350 |
| RoHS | Compliant | Compliant | Compliant | Compliant |
Diferenciadores clave
- High resolution in compact package (frente a DLP9500)
- Visible light optimized (frente a DLP4500NIR)
- Cost-effective for WXGA (frente a DLP9500)
Notas de diseño
The DLP4500 requires multiple power rails with specific sequencing. Ensure PWRGOOD and POSENSE signals are properly generated to avoid unreliable operation. Use low-noise LDOs for analog supplies and decouple each rail with 100nF and 10uF capacitors close to the pins.
The DLP4500 dissipates heat through the LCCC package. Provide adequate thermal vias and a copper pour on the PCB to keep the device within operating temperature. For high pattern rates, consider active cooling to prevent overheating.
Route the 30-bit parallel RGB interface with matched trace lengths to maintain signal integrity. Keep high-speed signals away from the micromirror array to avoid interference. Follow the layout guidelines in the TI datasheet for optimal performance.
Información de cumplimiento
RoHS compliant per TI product page. Other compliance data not specified in provided sources.