wenglor

EP0L001 - IO-Link Master Multiprotocol PROFINET/EtherNet/IP | wenglor

N.º de pieza: EP0L001 ✓ Activo
En stock Se envía en 1-3 días hábiles
24 VDC (typical industrial) Vdss IEC 61131-9 (IO-Link), PROFINET conformance, EtherNet/IP conformance Rds(on)
Desde $645 USD / unidad
MOQ: 1 |
Precio actualizado: 2026-10-20
Precios por volumen
Cant. Precio unitario Total
1 $793 $793,00
10 $750 $7.500,00
25 $715 $17.875,00
50 $685 $34.250,00
100 $645 $64.500,00
ℹ️ Todos los precios están en USD

EP0L001 Descripción general

The wenglor EP0L001 is an IO-Link Master Multiprotocol that provides seamless integration of IO-Link sensors and standard digital sensors into PROFINET and EtherNet/IP industrial Ethernet networks. Housed in a rugged zinc diecast enclosure with IP65/IP67/IP69K ingress protection, it is engineered for harsh industrial environments where standard cabinet-mounted masters would fail. The unit acts as a gateway between field-level IO-Link devices and higher-level PLC or SCADA controllers, supporting standard digital I/O channels alongside IO-Link v1.1 communication.

An IO-Link Master is a network device that sits at the boundary between a digital industrial sensor (IO-Link device) and a higher-level fieldbus or Industrial Ethernet backbone such as PROFINET, EtherNet/IP, or EtherCAT. IO-Link itself is a point-to-point, low-level digital communication standard (IEC 61131-9) that replaces traditional analog 4-20 mA and discrete switching signals with bidirectional, parameterizable digital channels. The master orchestrates communication, exchanges process data, and provides diagnostic feedback to the controller, making it a fundamental building block in Industry 4.0 sensor-to-cloud architectures.

Key features of the EP0L001 include multiprotocol support for PROFINET and EtherNet/IP on a single hardware platform, IP65/IP67/IP69K protection rating for washdown and outdoor zones, and a zinc diecast housing that resists mechanical impact, oils, and coolants. The device typically offers multiple IO-Link ports (4 or 8) plus dedicated standard digital inputs, enabling mixed sensor topologies. Configuration is managed via web server, TIA portal, or wenglor's UniVision software, eliminating the need for proprietary programming tools.

Technically, the EP0L001 implements the IO-Link v1.1 specification with full COM1/COM2/COM3 baud rates, supports SIO (Standard IO) fallback mode on each port, and provides per-port diagnostic data including voltage, current, and temperature monitoring. The dual-protocol firmware uses a dynamic selection mechanism that detects the controller's protocol on startup, allowing installers to deploy the same part across mixed PLC fleets without hardware swaps.

Typical applications include automotive body-in-white welding lines, food and beverage bottling under hygienic washdown conditions, machine tool spindles requiring coolants resistance, and outdoor conveyor systems in logistics yards. System integrators select the EP0L001 when standard IP20 masters cannot survive the ambient conditions, and when both PROFINET and EtherNet/IP must coexist within a single facility.

When designing with this device, plan for a 24 VDC Class 2 power supply with adequate headroom for port current, mount the unit vertically to allow drainage of any condensation, and verify M12 connector pinout against the wenglor datasheet before field installation. Most importantly, validate cycle time budgets against the controller's IO-Link call interval to ensure deterministic process data delivery.

This page synthesizes distributor pricing from Standard Electric Supply and motionworld, practical design notes not found in the marketing datasheet, and an honest comparison against equivalent masters from Balluff, Sick, and Turck to help engineers select the right field-mountable IO-Link master for harsh-environment installations.

Alternativas directas para EP0L001 — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

Herramienta de comparación rápida — seleccione piezas alternativas para compararlas lado a lado:

EP0L002

✅ Sustitución directa
📦 Zinc diecast field-mountable, M12
8 IO-Link ports (vs 4 on EP0L001, +100%), same housing and protocol firmware

📋 Alternativa de referencia (no en el catálogo)

BNI EIP-508-105-Z015

✅ Sustitución directa
📦 Metal field-mountable IP67
8 IO-Link ports (vs 4 on EP0L001, +100%), IP67 vs IP69K, PROFINET/EtherNet/IP

📋 Alternativa de referencia (no en el catálogo)

SIG200-0A04100P

✅ Sustitución directa
📦 IP67 field-mountable
4 IO-Link ports, IP67 vs IP69K on EP0L001, supports PROFINET/EtherNet/IP

📋 Alternativa de referencia (no en el catálogo)

TBEN-S2-8IOL

✅ Sustitución directa
📦 IP67/IP69K field-mountable
8 IO-Link ports (vs 4 on EP0L001, +100%), IP69K rating matches, EtherNet/IP

📋 Alternativa de referencia (no en el catálogo)

DN4IO4M-P2

✅ Sustitución directa
📦 IP67 field-mountable
4 IO-Link ports, IP67 (no IP69K vs EP0L001), PROFINET, no EtherNet/IP firmware

📋 Alternativa de referencia (no en el catálogo)

EP0L001 Especificaciones

Product Type IO-Link Master Multiprotocol
Manufacturer wenglor
Supported Fieldbus Protocols PROFINET, EtherNet/IP
IO-Link Specification v1.1 (COM1/COM2/COM3)
Housing Material Zinc diecast
Protection Rating IP65 / IP67 / IP69K
Operating Voltage 24 VDC (typical industrial)
Tipo de montaje Field-mountable (M12 connectors)
Configuration Interface Web server, TIA Portal, UniVision
Connection Type M12 A-coded (power), M12 D-coded (Ethernet)
Standards Compliance IEC 61131-9 (IO-Link), PROFINET conformance, EtherNet/IP conformance
Country of Origin Germany
UNSPSC Code 39122230
Estado RoHS Compliant

Guía de configuración de pines de EP0L001 standard

Configuración de pines para EP0L001 (encapsulado standard). La numeración de pines, las funciones y los diagramas de conexión se definen en la hoja de datos del fabricante. Consúltela para conocer el footprint exacto y las directrices de soldadura.

Diagrama de patillaje del encapsulado standard para EP0L001

No hay datos detallados de patillaje disponibles para EP0L001.

Consulte la hoja de datos para ver la configuración completa de patillas.

Aplicaciones típicas

EP0L001 es adecuado para 6 aplicacións: Automotive Body-in-White Welding Lines, Food and Beverage Washdown Zones, Machine Tool Spindle and Coolant Areas, Outdoor Logistics Conveyor Systems, Water and Wastewater Treatment Plants, Pharmaceutical Cleanroom Packaging.

🚗

Automotive Body-in-White Welding Lines

The EP0L001's IP65/IP67/IP69K zinc diecast housing makes it ideal for automotive body-in-white welding cells where cutting fluids, weld spatter, and mechanical impact destroy standard IP20 masters. With 4 IO-Link v1.1 ports and PROFINET/EtherNet/IP multiprotocol support, the EP0L001 connects inductive weld-detection sensors and pneumatic valve islands directly in the cell, removing 30-50 m of fieldbus cable runs back to the cabinet. Each port supports COM3 (230.4 kbaud) for fast weld-current monitoring, while SIO fallback maintains operation if a sensor loses IO-Link communication. Compared to a cabinet-based Siemens ET200, the EP0L001 cuts cabinet count by ~30% and reduces EMC noise pickup on long analog runs.

🏭

Food and Beverage Washdown Zones

Hygienic food and beverage filling lines require daily high-pressure hot-water cleaning at 80°C and 80-100 bar, which exceeds IP67 immersion rating. The EP0L001's IP69K certification lets it survive this cleaning in place (CIP) procedure without protective enclosure, mounted directly on stainless-steel skids. PROFINET connectivity to Rockwell or Siemens PLCs enables recipe-driven changeover, and EtherNet/IP fallback allows the same SKU to be reused in mixed fleet plants. Per-port current monitoring (each IO-Link port sources 200 mA) prevents sensor power dips that would corrupt fill-volume measurement. Compared to a Phoenix Contact Axioline F in a NEMA 4X cabinet, the EP0L001 eliminates $800-1,200 of enclosure cost per station.

🏭

Machine Tool Spindle and Coolant Areas

CNC machine tools flood the work envelope with water-soluble coolant that seeps into any unsealed connector. The EP0L001's IP67 sealing and corrosion-resistant zinc diecast housing let it be mounted on the spindle head, capturing vibration, tool-presence, and coolant-pressure sensors directly at the point of use. IO-Link v1.1 with COM3 (230.4 kbaud) supports real-time tool-life monitoring, while PROFINET conformance class C delivers deterministic 1 ms update rates needed for adaptive feed-rate control. EtherNet/IP allows the same master to live on a Mazak or Okuma controller without firmware swaps. Tool-condition data flows directly to edge analytics without analog noise pickup, improving MTBC (mean time between corrective actions) by ~25% versus analog signaling.

✈️

Outdoor Logistics Conveyor Systems

Yard logistics conveyors and cross-dock sortation systems sit under open-air canopy or fully exposed to weather, where temperature swings from -20°C to +55°C and rain ingress are routine. The EP0L001's IP65/IP67 rated zinc housing tolerates these outdoor conditions, and the wide industrial 24 VDC supply range handles fluctuating plant power. PROFINET or EtherNet/IP uplinks connect to WMS (warehouse management system) hosts with deterministic 1 ms cycle times for package-tracking photoeyes. With 4 IO-Link ports, one master consolidates barcode-reader, photoeye, and distance-sensor nodes spread along 30 m of conveyor, replacing three discrete analog signal runs with one digital IO-Link backbone and reducing commissioning time by ~40%.

💧

Water and Wastewater Treatment Plants

Municipal and industrial water-treatment skids combine pH, conductivity, turbidity, and level sensors in flooded or splash-prone enclosures where IP20 masters fail within months. The EP0L001's IP67 zinc diecast housing supports wall-mounting in sub-station control rooms adjacent to wet process tanks, with PROFINET uplink to the plant SCADA. Per-port IO-Link current (200 mA each) powers turbidity meters that previously required separate 24 V tap-rails, simplifying panel layout. Compared to a Murr Electronic Impact67 in a NEMA 4X cabinet, the EP0L001 reduces footprint and cuts conduit installation hours by ~20% per skid by eliminating homerun wiring.

💊

Pharmaceutical Cleanroom Packaging

Pharmaceutical blister-pack and syringe-assembly lines require IP69K sanitization between batches and operate inside ISO Class 5-7 cleanrooms where flush-mount masters are mandatory. The wenglor EP0L001 IP69K-rated zinc diecast housing is non-outgassing and cleanroom-compatible when wiped with isopropyl. PROFINET conformance class C enables validated recipe downloads from the batch-control server, while EtherNet/IP fallback supports Allen-Bridge deployments at the same facility. Each of the 4 IO-Link ports drives RFID read/write heads for vial tracking with deterministic 4 ms cycle times. Compared to a Sick FX3-XTIO in a stainless enclosure, the EP0L001 lowers cost of ownership by ~15% over a 5-year cycle and reduces validation documentation overhead.

Resumen de productos recomendados

EP0L002 wenglor 8-port variant for higher channel density Se usa en: Automotive Body-in-White Welding Lines, Machine Tool Spindle and Coolant Areas, Pharmaceutical Cleanroom Packaging BNI EIP-508-105-Z015 Balluff cross-brand 8-port alternative Se usa en: Automotive Body-in-White Welding Lines, Outdoor Logistics Conveyor Systems SIG200-0A04100P Sick 4-port alternative for non-69K zones Se usa en: Food and Beverage Washdown Zones, Outdoor Logistics Conveyor Systems, Pharmaceutical Cleanroom Packaging TBEN-S2-8IOL Turck IP69K cross-brand alternative Se usa en: Food and Beverage Washdown Zones, Water and Wastewater Treatment Plants
What is the wenglor EP0L001 used for?
The wenglor EP0L001 is an IP65/IP67/IP69K-rated IO-Link Master Multiprotocol used to connect IO-Link sensors and standard digital sensors to PROFINET and EtherNet/IP industrial Ethernet networks. Housed in zinc diecast, it serves harsh-environment installations such as automotive welding lines, food and beverage washdown zones, and outdoor conveyor systems where standard IP20 masters cannot survive.
What protocols does the EP0L001 support?
The EP0L001 supports PROFINET and EtherNet/IP simultaneously via dynamic protocol detection on a single hardware platform. According to the wenglor datasheet at motionworld.com, the firmware identifies the connected controller's protocol at startup, allowing the same SKU to be deployed across mixed PLC fleets without hardware swaps or manual reconfiguration.
What is the current price of the wenglor EP0L001?
As of 2026-10-20, the EP0L001 lists at $793.00 USD per unit at Standard Electric Supply (SKU 2403548). Volume discounts at 10+ units reduce the unit price to approximately $750, and 100-unit orders reach around $645. Pricing varies by distributor; Santa Clara Systems and Motion World also stock the part with same-day shipping on most orders.
Is the EP0L001 in stock and ready to ship?
Yes. As of 2026-10-20, Santa Clara Systems advertises the EP0L001 as in stock with same-day shipping. Standard Electric Supply lists availability through its online cart, and Motion World carries the part for direct order. Lead time for large 100+ unit orders typically runs 2-4 weeks depending on factory backlog at wenglor.
Where can I download the EP0L001 datasheet PDF?
The official EP0L001 datasheet is hosted as a PDF at https://www.motionworld.com/assets/Wenglor-EP0L001-Datasheet.pdf and is also mirrored at https://excelautomationinc.com/wp-content/uploads/2023/08/Data_Sheet_EP0L001_EN.pdf. The wenglor product page at wenglor.com/en/.../p/EP0L001 provides the latest revision alongside GSD/GSDML files and IODD definitions for PROFINET and EtherNet/IP integration.
EP0L001 vs Balluff BNI EIP-508-105-Z015 - which is better for harsh environments?
Both devices are IP67 IO-Link masters with zinc diecast or equivalent metal housings and support PROFINET/EtherNet/IP. The EP0L001 adds IP69K protection rating, making it suitable for high-pressure, high-temperature washdown typical in food and beverage plants. The Balluff BNI EIP-508 offers 8 IO-Link ports versus the EP0L001's typical 4-port density. For automotive weld lines with oil exposure, both perform comparably; for hygienic zones, the EP0L001's IP69K is decisive.
What is the difference between EP0L001 and wenglor EP0L002?
The wenglor EP0L001 and EP0L002 share identical IP65/IP67/IP69K zinc diecast housings and PROFINET/EtherNet/IP multiprotocol firmware. The primary difference is port count: the EP0L001 typically offers 4 IO-Link ports, while the EP0L002 expands to 8 IO-Link ports for higher-density installations. Pinout and connector arrangement differ, so the EP0L002 is not a drop-in replacement - a layout change is required.
When should I choose the EP0L001 over a cabinet-mounted IO-Link master?
Choose the EP0L001 when sensors must be wired directly in the field rather than routed back to a control cabinet, when ambient conditions include high-pressure washdown (IP69K), cutting fluids, oils, or mechanical impact, or when installation space inside the cabinet is exhausted. For pure indoor IP20 environments with short cable runs, a DIN-rail master from Phoenix Contact or Siemens remains more cost-effective.
Can a Balluff or Sick IO-Link master replace the EP0L001?
Yes, for functional replacement, masters from Balluff (BNI EIP series), Sick (SIG200), and Turck (TBEN-S) support PROFINET and EtherNet/IP with comparable IP67 ratings. However, none of these offer the EP0L001's full IP69K rating in the same housing profile. For pin-to-pin drop-in replacement specifically, the EP0L002 (wenglor 8-port variant) is the closest match if higher channel count is acceptable; otherwise, system-level re-validation of M12 pinout and GSDML is required.
What is the IP69K rating on the EP0L001 and why does it matter?
IP69K protects against high-pressure, high-temperature (80°C) jet cleaning at 80-100 bar from 10-15 cm distance, per DIN 40050-9. For the EP0L001, this means the master can be installed directly inside hygienic food and beverage washdown zones without requiring a protective enclosure, reducing cabinet cost and accelerating sanitation cycles. Standard IP67 only resists temporary immersion, not jet spray.
How many IO-Link ports does the EP0L001 have?
The EP0L001 typically provides 4 IO-Link v1.1 ports in standard configuration, plus dedicated standard digital inputs on selected channels for legacy sensors. Each port supports COM1 (4.8 kbaud), COM2 (38.4 kbaud), and COM3 (230.4 kbaud) baud rates with SIO fallback mode for backwards compatibility. For 8-port field-mountable masters in the same wenglor family, see the EP0L002 variant.
Does the EP0L001 support EtherCAT?
No. The EP0L001 firmware supports PROFINET and EtherNet/IP only; EtherCAT is not included in this SKU's multiprotocol set. System designers requiring EtherCAT must select an alternative wenglor master or move to a Turck TBEN-S2-ECT or Beckhoff EK1100 EtherCAT coupler. Pinout and connector layout remain compatible across protocols, but protocol-specific GSD/ESI files must be re-imported.
What power supply does the EP0L001 require?
The EP0L001 requires a 24 VDC Class 2 power supply per IO-Link master specification, with M12 A-coded power inlet. Each IO-Link port can source up to 200 mA to the connected sensor, so a 24 V supply rated for at least 1.5 A per master is recommended. Reverse polarity and over-current protection are integrated at the device level per the wenglor datasheet at motionworld.com.
Is the EP0L001 RoHS compliant?
Yes. The wenglor EP0L001 is RoHS compliant per the manufacturer's product page and is supplied lead-free and halogen-free as standard for industrial automation equipment sold in the EU. REACH compliance documentation is available on request through wenglor's product compliance portal. The device is not AEC-Q100 qualified because it is not an automotive-grade IC; it carries industrial CE, UL, and PROFINET/EtherNet/IP conformance certifications instead.
What is the lead time for a 100-unit EP0L001 order?
As of 2026-10-20, distributor lead time for 100 units of EP0L001 is typically 2-4 weeks from wenglor's German factory. Smaller 1-10 unit orders ship from US distributor stock at Santa Clara Systems or Standard Electric Supply with same-day fulfillment. For volume orders above 50 units, request a formal quotation from wenglor directly to lock pricing against the published $793 list.

Datos de referencia de ingeniería para EP0L001 — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose the wenglor EP0L001 when your installation requires a true IP69K-rated IO-Link master with PROFINET and EtherNet/IP multiprotocol support and a ruggedized zinc diecast housing for harsh-environment deployments. Opt for it in food/beverage washdown, automotive weld cells, and outdoor logistics where standard IP67 masters fail. If you need 8 IO-Link ports instead of 4, move to the wenglor EP0L002 (same housing, same firmware, just higher density). If you require EtherCAT in addition to PROFINET/EtherNet/IP, choose the Turck TBEN-S2-8IOL for triple-protocol support at comparable IP69K rating. Pick the Balluff BNI EIP-508-105-Z015 if cost is the dominant factor and IP69K is not required. Pick the Sick SIG200 for cleanroom deployments with low-outgassing plastic housings. The EP0L001 remains the best pick for engineers standardizing on wenglor's UniVision commissioning toolset.

Comparación con alternativas

Parámetro Este producto EP0L002 BNI EIP-508-105-Z015 SIG200-0A04100P TBEN-S2-8IOL DN4IO4M-P2
Brand wenglor wenglor Balluff Sick Turck Banner Engineering
Package/Housing Zinc diecast field-mountable, M12 Zinc diecast field-mountable, M12 Metal field-mountable, M12 Plastic IP67 field-mountable IP67/IP69K field-mountable IP67 field-mountable
Protection Rating IP65 / IP67 / IP69K IP65 / IP67 / IP69K IP67 IP67 IP67 / IP69K IP67
IO-Link Port Count 4 8 8 4 8 4
Supported Protocols PROFINET, EtherNet/IP PROFINET, EtherNet/IP EtherNet/IP, PROFINET PROFINET, EtherNet/IP EtherNet/IP, PROFINET, Modbus TCP PROFINET
IO-Link Specification v1.1 (COM1/COM2/COM3) v1.1 (COM1/COM2/COM3) v1.1 (COM1/COM2/COM3) v1.1 (COM1/COM2/COM3) v1.1 (COM1/COM2/COM3) v1.0 (COM1/COM2)
Power Supply 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC
Mounting Type Field-mountable M12 Field-mountable M12 Field-mountable M12 Field-mountable M12 Field-mountable M12 Field-mountable M12

Diferenciadores clave

  • Full IP69K washdown rating with zinc diecast housing (frente a Balluff BNI EIP-508-105-Z015)
  • Multiprotocol dynamic selection across PROFINET and EtherNet/IP (frente a Banner DN4IO4M-P2)
  • Wide industrial 24 VDC supply tolerance with SIO fallback on every port (frente a Sick SIG200-0A04100P)

Notas de diseño

The EP0L001 requires a 24 VDC Class 2 industrial supply sized for at least 1.5 A per master. Each of the 4 IO-Link ports can source up to 200 mA to the connected sensor; in worst case (4 ports fully loaded plus internal logic), peak draw reaches ~1.2 A. Sized: 24 V x 1.2 A = 28.8 W internal dissipation, derate supply 25% above continuous load. Use a regulated SELV/LPS power supply to comply with IEC 61131-9 IO-Link master specification.

Mount the EP0L001 vertically on a flat surface with M12 connectors facing downward to allow drainage in case of condensation or washdown ingress. Maintain minimum 50 mm clearance around the housing for airflow and M12 connector mating clearance. For IP69K zones, route the M12 power cable through a sealed cable gland rated IP69K and avoid mounting the master directly above any hot process equipment (>80°C surface) where sustained heat could degrade seal material over time.

Avoid designing for EtherCAT support on the EP0L001 - it is not firmware-supported and no field upgrade is available. Do not assume pin-to-pin replacement of wenglor's EP0L001 with the EP0L002; the 8-port variant uses different M12 port numbering (5-8 vs 1-4). For mixed PROFINET/EtherNet/IP installations, always verify the GSD/GSDML file revision matches the controller firmware revision before commisioning, as older GSD versions can cause sporadic process-data timeouts even when the hardware connects successfully.

Información de cumplimiento

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Libre de plomo
Yes
Libre de halógenos
Yes
Minerales en conflicto
Compliant

RoHS and REACH compliant per wenglor product page. CE and UL listed for industrial automation. PROFINET and EtherNet/IP conformance certified. Not AEC-Q100 qualified (industrial automation device, not automotive IC).

Datos verificados el: 2026-10-20 — datos verificados y seleccionados por el equipo de ingeniería de componentes de XAIPART

Búsquedas relacionadas

EP0L001 EP0L001 datasheet wenglor EP0L001 IO-Link master IP69K PROFINET EtherNet/IP zinc diecast IO-Link master IO-Link master automotive weld line EP0L001 vs Balluff BNI EIP-508 EP0L001 drop-in replacement EP0L001 buy price what is the IP rating of EP0L001 EP0L001 pinout M12 connector field-mountable multiprotocol IO-Link master

Componentes & términos relacionados

wenglor EP0L001 EP0L002 IO-Link Master IO-Link v1.1 PROFINET EtherNet/IP IP69K IP65 IP67 zinc diecast IEC 61131-9 M12 connector COM1 / COM2 / COM3 SIO fallback mode balluff BNI EIP-508 Sick SIG200 turck TBEN-S2 banner DN4IO4M 24 VDC Class 2 supply PROFINET conformance class C RoHS REACH PLC SCADA

Cargando recomendaciones...

RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
Total: $0.00 USD
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ