ICL7137CQH Descripción general

The Maxim Integrated ICL7137CQH is a low-power, 3.5-digit dual-slope analog-to-digital converter with a direct LCD driver in a 44-pin QFP package. It operates in the commercial 0°C to 70°C temperature range, has 44 J-bend terminals, and is identified by package code QCCJ. The listed input-voltage range is 2.6 V to 3.2 V.

An ADC is an integrated circuit that converts an analog voltage into a numeric value. The dual-slope technique used by the ICL7137CQH integrates the unknown input over a fixed interval and compares it with a reference ramp. A digital counter then measures the integration time required to reach balance. This method is suited to panel meters, laboratory instruments, digital scales, and other systems where stable readings and direct display-driver integration are more important than very high conversion speed.

The ICL7137CQH combines low-power operation with 3.5-digit measurement resolution and direct LCD drive capability. Its 44-pin package provides separate connections for analog measurement inputs, reference circuitry, timing, digital data, and display outputs. The commercial temperature range supports equipment intended for controlled indoor or industrial environments rather than extended automotive, military, or extreme-temperature operation.

The 44-pin QFP package provides adequate connection density for analog, digital, and display functions while supporting surface-mount assembly. The MS-022AB package designation and J-bend terminal form identify a leaded quad flat package. Designers must preserve the package footprint, pin assignment, analog trace geometry, bypass-capacitor placement, and reference-source arrangement when revising a circuit around this converter.

Typical uses include digital panel meters, precision weighing indicators, temperature-display instruments, laboratory measurement equipment, and process-monitoring panels. Direct LCD drive is particularly useful when the converter's digital outputs can operate a display without an additional display-controller IC. In each case, the design must account for reference accuracy, input integration timing, display update rate, and the electrical limits of the connected LCD.

A critical layout consideration is the analog input and reference network. Keep these connections short, place the associated bypass capacitors close to their supply pins, and route digital and display signals away from sensitive analog nodes. Verify timing and conversion behavior with the intended source impedance because the dual-slope measurement integrates current rather than sampling an instantaneous voltage.

This product page organizes the verified electrical, environmental, mechanical, and commercial attributes of the ICL7137CQH. It also identifies same-brand alternatives in the related cross-reference results and adds application, comparison, and design guidance to help engineers evaluate a replacement without overlooking display-driver or measurement-system differences.

Alternativas directas para ICL7137CQH — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

ICL7136CQH+TD

✅ Sustitución directa
📦 PLCC-44 (QCCJ)
Same 44-pin package family; related converter functions, while LCD-drive behavior and timing require pin-level verification

📋 Alternativa de referencia (no en el catálogo)

ICL7107CQH+TD

✅ Sustitución directa
📦 PLCC-44 (QCCJ)
Same 44-pin package family, but identified as an LED-display-driver converter rather than the ICL7137's direct LCD driver

📋 Alternativa de referencia (no en el catálogo)

ICL7137CQH Valores máximos y características eléctricas

Converter Type Dual-slope analog-to-digital converter
Display Resolution 3.5 digits
Low-Power Operation Low-power device
Display Output Direct LCD driver
Package Type QFP, 10 mm x 10 mm x 2 mm
Package Outline MS-022AB
Package Code QCCJ
Terminal Count 44 terminals
Terminal Form J-bend
Package Shape Square
Rango de tensión de entrada 2.6 V to 3.2 V
Rango de temperatura de funcionamiento 0°C to 70°C (32°F to 158°F)
Screening Level Commercial
Estado RoHS RoHS compliant

Guía de configuración de pines de ICL7137CQH square

Configuración de pines para ICL7137CQH (encapsulado square). Este componente analógico presenta pines de entrada, salida y alimentación. Consulte la hoja de datos del fabricante para conocer las configuraciones de los pines de ajuste de offset, compensación y habilitación. Ideal para circuitos de acondicionamiento de señal y amplificadores.

Diagrama de patillaje del encapsulado square para ICL7137CQH

No hay datos detallados de patillaje disponibles para ICL7137CQH.

Consulte la hoja de datos para ver la configuración completa de patillas.

Aplicaciones típicas

ICL7137CQH es adecuado para 6 aplicacións: Digital Panel Meter, Laboratory Measurement Instrument, Digital Weighing Scale, Temperature Display Instrument, Process Monitoring Panel, Portable Meter.

📺

Digital Panel Meter

The ICL7137CQH fits a digital panel meter because it combines a 3.5-digit dual-slope ADC with direct LCD drive in one 44-pin QFP package. Placing the converter at the center of the measurement path reduces the need for a separate display-controller IC and simplifies the relationship between the sampled voltage and displayed digits. The 0°C to 70°C commercial range suits indoor instruments and controlled industrial panels. Designers should preserve the reference network and analog input layout, verify display segment and common-output assignments, and confirm that the 2.6 V to 3.2 V listed input range matches the intended signal and LCD interface.

🔬

Laboratory Measurement Instrument

A laboratory measurement instrument can use the ICL7137CQH to convert a slowly changing analog input into a stable 3.5-digit display value. Dual-slope conversion is appropriate for instruments that value repeatable readings, integrated measurement time, and direct LCD presentation over rapid sampling. The device's 44-pin QFP interface provides access to measurement, timing, reference, digital, and display functions, but it also requires disciplined layout. Keep the analog input and reference paths compact, place bypass components near the relevant pins, and test the complete front end with the source impedance and temperature range planned for the instrument.

⚖️

Digital Weighing Scale

The ICL7137CQH is suitable for a basic digital weighing-scale display when the load-cell signal is conditioned into a voltage compatible with the converter's measurement system. The 3.5-digit result format and direct LCD drive suit compact tabletop indicators where the measured weight is presented locally without a separate display processor. A scale designer must carefully balance reference accuracy, signal polarity, integration timing, and display update behavior. Because the ICL7137CQH operates within a 0°C to 70°C commercial range, enclosure heating or temperature compensation may be necessary where the mechanism or electronics experience wider ambient changes.

🌡️

Temperature Display Instrument

In a temperature display instrument, the ICL7137CQH can digitize a conditioned sensor voltage and directly drive an LCD showing the measured value. This arrangement is useful for standalone thermometers, environmental monitors, and process-temperature panels where a compact numerical readout is sufficient. The converter's 3.5-digit resolution should be matched to the required display precision, while the external reference and sensor interface determine actual measurement accuracy. Use the manufacturer application information to select stable timing and reference components, and keep display-drive traces separated from sensitive analog inputs to reduce coupling into the measured signal.

🏭

Process Monitoring Panel

The ICL7137CQH can serve as the front-end and display controller in a process-monitoring panel that presents one measured process variable locally. Its direct LCD drive and integrated conversion function simplify systems where an operator needs a local reading but not a high-speed digital interface. For industrial use, keep the device within its 0°C to 70°C rating and isolate it from temperature, vibration, and electrically noisy sections of the enclosure. The analog input, reference, and conversion timing components determine stability, so prototype the complete measurement chain and verify display accuracy before production release.

🔋

Portable Meter

The ICL7137CQH can form the measurement and display core of a portable meter where a compact local LCD is more useful than a serial digital output. Its low-power designation and integrated display drive support battery-operated instrument concepts, although the final current budget depends on the complete converter and LCD operating mode. The 44-pin QFP package is suitable for compact surface-mount assembly, while the 0°C to 70°C range constrains environmental use. Confirm standby current, conversion behavior, and LCD compatibility directly from the manufacturer datasheet, and select reference and timing components that support stable readings over the intended battery-voltage range.

What is the ICL7137CQH?
The ICL7137CQH is a Maxim Integrated low-power, 3.5-digit dual-slope analog-to-digital converter with a direct LCD driver. According to the manufacturer datasheet listing, it uses a 44-pin QFP package and is intended for digital measurement and display systems. Its dual-slope conversion architecture supports stable panel-meter readings, while the integrated LCD drive reduces the need for a separate display-interface IC.
What are the key specifications of ICL7137CQH that engineers should know?
The ICL7137CQH is a commercial-grade, 3.5-digit dual-slope ADC with direct LCD drive packaged in a 44-terminal QFP. According to the manufacturer datasheet listing, its listed input-voltage range is 2.6 V to 3.2 V, its package is 10 mm by 10 mm by 2 mm, and its operating-temperature range is 0°C to 70°C. These attributes define its suitability for controlled-environment digital panel instruments.
Where can I download the ICL7137CQH datasheet PDF?
The ICL7137CQH datasheet PDF is available through the Maxim Integrated datasheet listing at the datasheet URL on this page. The manufacturer datasheet is the primary source for pin assignments, electrical characteristics, timing, reference requirements, and recommended application circuits. Use the PDF when assigning PCB nets or validating operating limits, rather than relying on a distributor category page.
Where can I find the ICL7137CQH pinout?
The ICL7137CQH pinout is documented in the manufacturer datasheet under its 44-pin QCCJ package description and pin-description table. The verified package information identifies 44 J-bend terminals, an MS-022AB outline, and a 10 mm by 10 mm body. Use the numbered pin table to map analog inputs, reference connections, timing components, digital outputs, and LCD-drive outputs before laying out a replacement PCB.
Is the ICL7137CQH a drop-in replacement for other 44-pin converters?
The ICL7137CQH may be considered only when a candidate has the same QCCJ 44-pin footprint, identical pin functions, compatible electrical limits, and equivalent LCD-drive behavior. Related cross-reference data identifies ICL7136CQH+TD and ICL7107CQH+TD in PLCC-44 packages, but the ICL7137 is specified as a direct LCD-driver converter while the ICL7107 is identified as an LED-display-driver variant. Verify every signal and timing connection before replacement.
What can replace the ICL7137CQH?
ICL7136CQH+TD is the closest same-brand candidate in the related comparison data because both are 44-pin Analog Devices converter families. A valid replacement must preserve the ICL7137CQH footprint, pin functions, display-driver output, reference arrangement, and operating requirements. The ICL7107CQH+TD may share the 44-pin format, but its identification as an LED-display-driver converter creates an interface difference that must be checked against the target display.
Is the ICL7137CQH the same as ICL7136CQH+TD?
The ICL7137CQH and ICL7136CQH+TD are related 44-pin converters, but they should not be treated as identical without pin-level verification. The cross-reference comparison lists both as PLCC-44 devices and indicates related 3.5-digit converter functionality. The ICL7137 specifically provides direct LCD drive, so confirm display polarity, segment and common outputs, conversion timing, and pin assignments before using the ICL7136 as a replacement.
ICL7137CQH vs ICL7136CQH+TD - which is better for a panel meter?
The ICL7137CQH is generally the more direct choice for a panel meter that uses the converter's direct LCD driver. The related comparison identifies ICL7136CQH+TD as a closely related converter in a 44-pin package, but the ICL7137's LCD-drive role can simplify the display architecture. Choose the ICL7136 only after checking its display outputs, pinout, supply limits, reference requirements, and timing against the existing PCB.
What is the difference between ICL7137CQH and ICL7107CQH+TD?
The primary documented difference is the display-driver function: the ICL7137CQH is identified as a low-power 3.5-digit ADC with direct LCD drive, while ICL7107CQH+TD is identified as an LED-display-driver converter. Both appear in 44-pin comparison results, so package size alone does not establish interchangeability. Confirm whether the target display requires LCD common and segment outputs or LED drive signals before selecting either device.
When should I choose the ICL7137CQH over ICL7136CQH+TD?
Choose the ICL7137CQH when the design requires a low-power 3.5-digit converter with direct LCD drive and its verified 0°C to 70°C commercial-grade operating range. Consider ICL7136CQH+TD for a related 44-pin converter implementation after validating pin compatibility and display behavior. The decisive factors are the LCD interface, conversion timing, reference design, and mechanical fit rather than the shared terminal count alone.
Is the ICL7137CQH suitable for industrial measurement equipment?
The ICL7137CQH can suit industrial measurement equipment operating within its specified 0°C to 70°C range. It provides a 3.5-digit dual-slope conversion function and direct LCD drive for local instrument displays. The commercial screening level means it should not be assumed suitable for extended-temperature, automotive, or severe industrial environments unless the complete system requirements are independently satisfied.
Where can I buy ICL7137CQH online?
Use the Request a Quote form on this page to request ICL7137CQH availability, current lead time, and ordering information. The form is the appropriate route for a quote-oriented electronic component purchase without relying on an unconfirmed listing. Confirm the exact ICL7137CQH suffix, 44-pin package, delivery quantity, and manufacturer documentation when submitting the request.
What is the price of ICL7137CQH?
Current ICL7137CQH pricing is obtained through the Request a Quote form on this page. Price and availability can vary with the exact suffix, order quantity, package form, and market conditions, so a static figure can become stale. Include your required quantity and packaging preferences in the request to receive a current quotation.
What is the lead time for ICL7137CQH?
Request the current ICL7137CQH lead time through the Request a Quote form on this page. Lead time depends on availability, exact ordering information, and required quantity. Provide the target quantity and acceptable production schedule so the supplier response can reflect the intended build rather than a generic component availability statement.
Is ICL7137CQH in stock?
The current stock status of ICL7137CQH should be confirmed through the Request a Quote form on this page. A product listing alone does not establish an orderable quantity for the exact 44-pin suffix. Include your required quantity and schedule in the request, and confirm whether any delivered material must use the original manufacturer ordering code.
Does the ICL7137CQH comply with RoHS?
The verified component listing marks the ICL7137CQH as RoHS compliant and identifies its screening level as commercial. According to that product information, the device operates from 0°C to 70°C in a 44-pin QFP package. RoHS status addresses restricted-substance requirements, but final product compliance still depends on assembly materials, soldering processes, and the complete equipment supply chain.

Datos de referencia de ingeniería para ICL7137CQH — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose the ICL7137CQH for a 3.5-digit measurement system that needs direct LCD drive, a 44-pin QCCJ footprint, and operation across 0°C to 70°C. Consider ICL7136CQH+TD when its pinout, timing, reference design, and display interface match the existing design more closely; it is the closest related converter in the cross-reference results. Treat ICL7107CQH+TD as a lower-confidence replacement because it is identified as an LED-display-driver converter rather than a direct LCD-driver part. For either alternative, verify the 44-pin footprint, every signal assignment, supply voltage, reference requirement, conversion timing, and display polarity before releasing a PCB revision. If the application needs more resolution, faster sampling, wider temperature operation, or a standardized digital interface, a different ADC architecture may be preferable despite requiring a redesign.

Comparación con alternativas

Parámetro Este producto ICL7136CQH+TD ICL7107CQH+TD
Package PLCC-44 (QCCJ) PLCC-44 PLCC-44
Brand Maxim Integrated Analog Devices Analog Devices
Operating Supply Voltage 9 V minimum in related comparison listing 9 V minimum in related comparison listing 4.75 V to 5.25 V in related comparison listing
Terminal Count 44 terminals 44 terminals 44 terminals

Diferenciadores clave

  • Direct LCD-drive integration (frente a ICL7107CQH+TD)
  • Commercial-grade operating range (frente a ICL7136CQH+TD)
  • Exact 44-pin package identity (frente a ICL7136CQH+TD)

Notas de diseño

Treat the analog input, reference, and timing networks as a single high-impedance measurement section. Keep those traces short, avoid routing display-drive outputs beneath them, and place associated bypass capacitors close to the intended supply pins. Verify the completed layout against the manufacturer application circuit because a dual-slope converter can be sensitive to source impedance, leakage, and coupling from the display outputs.

Do not select a replacement solely because it has 44 terminals. Compare the numbered pin assignments, reference-voltage requirements, conversion timing, LCD common and segment outputs, and supply limits. The related ICL7136CQH+TD and ICL7107CQH+TD entries use the same 44-pin package family, but the ICL7107 is identified as an LED-display-driver variant, so an apparent footprint match may still require display-interface changes.

Budget the converter and LCD together because direct display drive adds load beyond the bare ADC function. Confirm the converter's operating and reference voltages, LCD logic levels, and expected display-update pattern from the manufacturer datasheet. If the design uses battery power, calculate average consumption over conversion and display phases rather than relying only on the low-power product designation.

Use a grounded plane that supports the analog reference network without creating long return paths through switching or display currents. Place external timing and reference components according to the manufacturer's recommended layout, keep unused inputs in defined states, and check clock or timing-pin connections against the exact suffix. These steps reduce measurement error and prevent a mechanically compatible board from behaving differently after substitution.

Información de cumplimiento

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
Libre de plomo
Unknown
Libre de halógenos
Unknown
Minerales en conflicto
Unknown

The verified component listing explicitly identifies the ICL7137CQH as RoHS compliant and classifies it as commercial grade. No verified information establishes REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification status.

Datos verificados el: 2026-11-04 — datos verificados y seleccionados por el equipo de ingeniería de componentes de XAIPART

Búsquedas relacionadas

ICL7137CQH datasheet ICL7137CQH pinout ICL7137CQH datasheet pdf ICL7137CQH specifications ICL7137CQH equivalent ICL7137CQH replacement ICL7137CQH cross reference ICL7137CQH footprint ICL7137CQH vs ICL7136CQH+TD ICL7137CQH application circuit Maxim Integrated ICL7137CQH ICL7137CQH price ICL7137CQH stock

Componentes & términos relacionados

Maxim Integrated Analog Devices ICL7137CQH ICL7136CQH+TD ICL7107CQH+TD ICL7116CPL+ dual-slope ADC 3.5-digit ADC analog-to-digital converter direct LCD driver LED display driver QCCJ PLCC-44 QFP MS-022AB J-bend terminal commercial grade RoHS reference voltage conversion timing digital panel meter laboratory measurement digital weighing scale process monitoring surface mount
RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ