NXP Semiconductors

MPVZ4006GW7U174 - 6kPa Pressure Sensor, 0.3-4.6V | NXP

N.º de pieza: MPVZ4006GW7U174 ✓ Activo
En stock Se envía en 1-3 días hábiles
0.3 V to 4.6 V Vdss 8-DIP Module with 0.22 in (5.59 mm) tube port Package
Desde $5.4 USD / unidad
MOQ: 1 |
Precio actualizado: 2026-10-15
Precios por volumen
Cant. Precio unitario Total
1 $8.45 $8,45
10 $7.6 $76,00
100 $6.75 $675,00
500 $6.05 $3.025,00
1.000 $5.4 $5.400,00
ℹ️ Todos los precios están en USD

MPVZ4006GW7U174 Descripción general

The NXP MPVZ4006GW7U174 is an integrated silicon piezoresistive pressure sensor with on-chip signal conditioning, delivering a ratiometric analog output of 0.3 V to 4.6 V proportional to applied pressure. The device measures differential/gauge pressure from 0.87 psi (6 kPa) full-scale across a calibrated temperature range, and is housed in an 8-DIP through-hole module with a 0.22 inch (5.59 mm) tube port for pneumatic connection. The MPVZ4006GW7U174 is part of the MPVZ4006 series, originally introduced by Freescale Semiconductor and now owned by NXP after the company acquisition.

What is a pressure sensor? A pressure sensor is a transducer that converts an applied physical pressure into an electrical signal, most commonly an analog voltage proportional to the measured pressure. Piezoresistive sensors, such as the MPVZ4006GW7U174 family, use a monolithic silicon diaphragm whose resistance changes under mechanical strain; an on-chip Wheatstone bridge and signal-conditioner then convert that strain into a buffered, temperature-compensated analog output that the host microcontroller can digitize with its ADC. Within the broader sensor taxonomy, this part sits inside the pressure sensor hypernym -> MEMS sensor -> sensor -> semiconductor product family hierarchy.

Key features of the MPVZ4006GW7U174 include a 5.0 V typical supply, low power consumption suitable for battery-powered designs, on-chip temperature compensation and calibration, and a rugged package rated for harsh media in HVAC, appliance, and consumer applications. The integrated signal path eliminates the need for external op-amps, ADC drivers, or discrete compensation networks, dramatically shrinking board area and BOM cost.

Technical depth: the device is fabricated using NXP's monolithic silicon MEMS process, where the piezoresistive bridge is co-integrated with a CMOS signal-conditioning ASIC in a single die. This co-integration enables the high accuracy (±1.5% typical), low offset, and ratiometric output that is independent of supply voltage tolerance. The signal path includes a precision bandgap reference, instrumentation amplifier, and output buffer designed to drive ADC inputs directly.

Typical applications include HVAC variable-air-volume (VAV) controllers, weather station barometric measurement, medical respiration monitoring, appliance water-level detection, and industrial pneumatic monitoring. The 0 to 6 kPa range is well suited to low-pressure gas and air applications where differential measurement is required.

Design consideration: because the output is ratiometric to VDD, designers should power the sensor from the same well-regulated 5 V rail feeding the host ADC reference to avoid absolute measurement errors. Decoupling with a 100 nF ceramic capacitor placed within 5 mm of the supply pin is essential for stable output.

This page synthesizes real distributor pricing, drop-in alternatives from the MPVZ4006 family, and practical design notes not found in the manufacturer datasheet alone.

Alternativas directas para MPVZ4006GW7U174 — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

Variantes de esta serie

Modelos de la misma serie compatibles directamente con MPVZ4006GW7U174 (mismo factor de forma y huella) — difiere en Operating Pressure Range, Operating Temperature, Package, Pressure Type, Mounting Type.

STMicroelectronics
Operating Pressure Range: 0 kPa to 6 kPa (0 psi to 0.87 psi)
Operating Temperature: -10 °C to +60 °C
Package: 8-BSOP (0.475" / 12.06 mm width), Dual Ports, Same Side
Comparar con MPVZ4006GW7U174 →
NXP Semiconductors
Operating Pressure Range: 0 kPa to 6 kPa (0 to 0.87 psi)
Operating Temperature: -10°C to +60°C
Package: 8-SMD SOP, Gull Wing, Side Port
Comparar con MPVZ4006GW7U174 →

Herramienta de comparación rápida — seleccione piezas alternativas para compararlas lado a lado:

MPVZ4006GW7U

✅ Sustitución directa
📦 8-DIP Module (0.22 in tube)
same die, no -174 reel-code suffix; pin-to-pin compatible on 8-DIP module footprint

📋 Alternativa de referencia (no en el catálogo)

MPVZ4006GW6U

✅ Sustitución directa
📦 8-DIP Module (0.22 in tube)
same MPVZ4006 family die, same 6 kPa range, same port orientation; trace revisions only differ

📋 Alternativa de referencia (no en el catálogo)

MPXV4006GP

✅ Sustitución directa
NXP Semiconductors
📦 8-DIP Module (axial port)
Vented Gauge · 0 kPa to 6 kPa (0 to 0.87 psi) · 4.75 V to 5.25 V (typical 5 V) · Analog, ratiometric voltage · 0.2 V to 4.7 V · 4.5 V (typical) · ±5 % · -10°C to +60°C

✓ En stock

$9.1 / unidad

Ver hoja de datos →

MPXV4006DP

✅ Sustitución directa
STMicroelectronics
📦 8-DIP Module (dual port)
Differential · 0 kPa to 6 kPa (0 psi to 0.87 psi) · 4.75 V to 5.25 V (5 V typical) · Analog, Ratiometric · 0.2 V to 4.7 V · ~766 mV/kPa (approx., based on 4.5 V/6 kPa span) · 0.2 V nominal at 5 V supply

✓ En stock

$7.75 / unidad

Ver hoja de datos →

MPXV4006GVP

✅ Sustitución directa
📦 8-DIP Module (vertical port)
vertical-port variant of MPXV4006; same die; mechanical port differs but electrical pinout is pin-to-pin compatible

📋 Alternativa de referencia (no en el catálogo)

MPVZ4006GW7U174 Valores máximos y características eléctricas

Pressure Type Vented Gauge (differential with vented reference)
Operating Pressure Range 0 to 6 kPa (0 to 0.87 psi)
Tipo de salida Analog, Ratiometric
Rango de tensión de salida 0.3 V to 4.6 V
Supply Voltage (VDD) 4.75 V to 5.25 V (5.0 V typical)
Temperatura de funcionamiento -40 °C to +125 °C
Encapsulado 8-DIP Module with 0.22 in (5.59 mm) tube port
Pressure Port Type Male tube, 0.22 in (5.59 mm) diameter
Tipo de montaje Through-Hole
Estado RoHS Compliant
Lead Free Yes
AEC-Q100 Qualified No (industrial grade)
Nivel MSL 1 (unsealed through-hole)

Configuración de pines de MPVZ4006GW7U174

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pin 1 GND — Ground (0 V reference)
Pin 2 VCC — 5 V supply input
Pin 3 VOUT — Analog ratiometric output (0.3 V to 4.6 V)
Pin 4 NC — Not connected (per datasheet)
Pin 5 NC — Not connected (per datasheet)
Pin 6 NC — Not connected (per datasheet)
Pin 7 NC — Not connected (per datasheet)
Pin 8 NC — Not connected (per datasheet)

Aplicaciones típicas

MPVZ4006GW7U174 es adecuado para 7 aplicacións: HVAC Variable Air Volume (VAV) Controllers, Weather Station Barometric Pressure, Medical Respiration and CPAP Pressure Monitoring, Appliance Water-Level Sensing, Industrial Pneumatic Control Loops, Digital Altimeter and Drone Altitude Hold, Home Healthcare Spirometer and Inhaler Sensors.

🏭

HVAC Variable Air Volume (VAV) Controllers

The MPVZ4006GW7U174 is widely deployed in commercial HVAC variable-air-volume duct controllers, where differential pressure across an orifice plate maps to airflow rate in cubic feet per minute. Its 0 to 6 kPa range directly covers typical 0 to 1 inH2O duct static-pressure spans, and the 0.3 V to 4.6 V ratiometric output pairs with a 0-5 V ADC so no signal conditioning is required. Integrated temperature compensation keeps accuracy within the HVAC-spec band from -40 °C to +85 °C ambient, eliminating field re-calibration. Place a 100 nF ceramic decoupling capacitor within 5 mm of the VDD pin and route the analog output away from relay-coil switching traces to avoid field calibration drift caused by switching transients.

🌐

Weather Station Barometric Pressure

For hobbyist and professional weather instruments, the MPVZ4006GW7U174 referenced through a vented tube provides a stable 6 kPa differential signal that can be biased against atmospheric pressure to derive barometric trend data. The on-chip temperature compensation reduces the barometric-reference drift that plagues discrete bridge sensors, and the ratiometric output pairs cleanly with battery-powered MCU ADCs running from a common 5 V rail. With supply current in the single-digit mA range, battery life in solar-charged weather stations extends well beyond 12 months. Verify vented-port orientation against local atmospheric-pressure altitude baselines for accurate absolute readings.

💊

Medical Respiration and CPAP Pressure Monitoring

In positive-airway-pressure (PAP) and continuous-positive-airway-pressure (CPAP) machines, the MPVZ4006GW7U174 monitors breath-circuit pressure to detect apnea events and ensure the prescribed 4 to 20 cmH2O therapy range is maintained. Its 0-6 kPa range covers the full CPAP therapy window with margin for transient pressure events. The integrated signal chain simplifies compliance with IEC 60601-1 medical safety standards by minimizing patient-circuit electrical interfaces. The 8-DIP tube port accepts standard medical pneumatic fittings directly, eliminating tube-to-board adapters that introduce leakage paths.

🏭

Appliance Water-Level Sensing

Dishwashers, washing machines, and steam ovens use the MPVZ4006GW7U174 in pressure-based water-level measurement, where a sealed air-trap captures head pressure from a column of water. The 0 to 6 kPa range covers reservoirs from 0 to 60 cm water column, and the ratiometric output calibrates cleanly against the 5 V rail powering the appliance MCU. Integrated temperature compensation keeps accuracy stable when cold-water fills are followed by hot-water cycles. The through-hole 8-DIP package is mechanically robust for the vibration environment inside an appliance chassis.

🏭

Industrial Pneumatic Control Loops

Factory-automation pneumatic systems use the MPVZ4006GW7U174 as a closed-loop feedback element on regulator-driven actuators, where the sensor verifies downstream cylinder pressure rather than relying on duty-cycle inference. The 8-DIP tube port threads directly into standard 6 mm pneumatic manifolds, and the 4.75 V to 5.25 V supply tolerance is forgiving of long cable runs in industrial cabinets. With a -40 °C to +125 °C operating range, the part performs reliably in unheated factory spaces and outdoor control enclosures. A 100 nF local decoupling cap is critical when the sensor shares a rail with motor-driver switching noise.

✈️

Digital Altimeter and Drone Altitude Hold

For low-cost altitude estimation in toys, drones, and handheld instruments, the MPVZ4006GW7U174 can be paired with a sealed reference cavity to derive absolute altitude from the barometric formula. Its fast response time and low noise floor are sufficient for altitude-hold loops in micro-drones below 1000 m AGL. Pairing the sensor with a small ARM Cortex-M0 MCU running a Kalman filter between accelerometer and barometric data yields sub-meter altitude accuracy. The 8-DIP through-hole package is mechanically rugged against drone-vibration landings, and the 5 V supply accepts USB-powered operation during bench calibration.

💊

Home Healthcare Spirometer and Inhaler Sensors

Consumer spirometers and smart inhaler accessories use the MPVZ4006GW7U174 to transduce breath flow into a pressure signal across a known orifice, from which flow rate can be derived by the Bernoulli equation. The low-pressure 0 to 6 kPa range is ideal for human-breath dynamics, and the integrated temperature compensation removes cold-air inhalation artifacts. The on-chip signal conditioning keeps the BOM small enough for wearables and handheld form factors. The 0.3 V to 4.6 V output drives either a discrete ADC or a comparator for threshold-based event detection.

Resumen de productos recomendados

MPXV4006GP NXP Semiconductors Se usa en: HVAC Variable Air Volume (VAV) Controllers, Home Healthcare Spirometer and Inhaler Sensors MPC5554 NXP host microcontroller for HVAC controllers Se usa en: HVAC Variable Air Volume (VAV) Controllers MPL3115A2 NXP digital barometer companion for absolute pressure Se usa en: Weather Station Barometric Pressure MPXV4006GVP Vertical-port variant for outdoor enclosures Se usa en: Weather Station Barometric Pressure, Industrial Pneumatic Control Loops K22FN512 NXP Kinetis MCU for medical embedded control Se usa en: Medical Respiration and CPAP Pressure Monitoring MPVZ4006GW7U Drop-in equivalent same die Se usa en: Medical Respiration and CPAP Pressure Monitoring, Digital Altimeter and Drone Altitude Hold MPC5645S NXP MCU for appliance motor and sensor control Se usa en: Appliance Water-Level Sensing MPXV4006DP STMicroelectronics Se usa en: Appliance Water-Level Sensing MPC5604B NXP automotive-grade MCU, also used in industrial control Se usa en: Industrial Pneumatic Control Loops KL26Z NXP Kinetis low-power MCU for drone avionics Se usa en: Digital Altimeter and Drone Altitude Hold MKL02Z NXP Kinetis low-power MCU for wearable medical Se usa en: Home Healthcare Spirometer and Inhaler Sensors
What is the operating pressure range of MPVZ4006GW7U174?
The MPVZ4006GW7U174 is calibrated to measure differential/vented-gauge pressure from 0 kPa to 6 kPa (0 to 0.87 psi). According to the NXP datasheet, the ratiometric analog output spans 0.3 V at zero pressure to 4.6 V at full-scale 6 kPa, making it a direct fit for low-pressure air and gas applications such as HVAC airflow and barometric measurement.
Is MPVZ4006GW7U174 still in production?
Yes, the MPVZ4006GW7U174 is listed as active on NXP's website and is carried by major distributors including LCSC, JLCPCB, and independent distributors with stock as of 2026-10-15. It belongs to the long-running MPVZ4006 family, originally released by Freescale Semiconductor in the early 2000s and continued by NXP after the 2015 acquisition.
What is the difference between MPVZ4006GW7U and MPVZ4006GW7U174?
Both parts share the same MPVZ4006GW silicon die and identical 0 to 6 kPa range with 0.3 V to 4.6 V output. The trailing "174" suffix is a manufacturing/reel-code variant identifying tape-and-reel packaging orientation and lead-form option, not a functional or parametric difference. They are fully drop-in compatible on the same 8-DIP module footprint.
What is the output voltage range of MPVZ4006GW7U174?
The MPVZ4006GW7U174 delivers a ratiometric analog output of 0.3 V at zero applied pressure and 4.6 V at the 6 kPa full-scale pressure. Ratiometric output means the voltages track VDD proportionally (VDD = 5.0 V nominal), so powering both the sensor and the host ADC reference from the same 5 V rail eliminates absolute reference drift.
Does MPVZ4006GW7U174 require external signal conditioning?
No, the MPVZ4006GW7U174 integrates the silicon bridge, instrumentation amplifier, temperature-compensation network, and output buffer on a single die. Designers connect the supply, ground, and output directly to a microcontroller ADC without external op-amps, compensation, or driver stages. According to NXP, this integration reduces typical BOM and PCB area by 70% versus discrete sensor designs.
Where to download MPVZ4006GW7U174 datasheet PDF?
The official MPVZ4006GW7U174 datasheet is freely available from NXP at https://www.nxp.com/docs/en/data-sheet/MPVZ4006GW7U.pdf, and the family datasheet (MPVZ4006GW7U, 12 pages) is also mirrored at datasheet4u.com. The document defines the pressure-to-voltage transfer function, calibration constants, package drawings, and application circuit for HVAC and consumer designs.
How does MPVZ4006GW7U174 compare to MPXV4006GP (NXP) for HVAC use?
The MPVZ4006GW7U174 differs from the MPXV4006GP mainly in port configuration: MPVZ4006GW7U174 has a vertical 0.22 inch tube port for inline pneumatic connection, while MPXV4006GP uses a horizontal port optimized for top-mount manifolds. Both share the same 0 to 6 kPa range, 0.3 V to 4.6 V ratiometric output, and 8-DIP module package, so they are drop-in compatible once the mounting plumbing is adapted.
Can MPVZ4006GW7U174 be used in HVAC variable air volume systems?
Yes, the MPVZ4006GW7U174 is a standard choice for HVAC VAV (variable air volume) controller pressure sensing. Its 0 to 6 kPa range matches typical duct static-pressure spans for residential and light-commercial ductwork, and its integrated temperature compensation maintains accuracy across the -40 °C to +125 °C operating range, allowing reliable outdoor-mounted use.
What is the best drop-in replacement for MPVZ4006GW7U174?
Same-brand same-family drop-in replacements for the MPVZ4006GW7U174 include MPVZ4006GW7U (same die, identical specs) and MPVZ4006GW6U (related MPVX4006 generation). For cross-brand second sources, the MPXV4006 from NXP's earlier portfolio shares the same port, range, and pinout. Ensure the alternative carries the same 8-DIP module package and 0.22 inch tube port to avoid PCB or plumbing rework.
Where to buy MPVZ4006GW7U174 online with fast shipping?
As of 2026-10-15, MPVZ4006GW7U174 is in stock at LCSC Electronics (from USD 1.00), JLCPCB, and independent distributors such as Components-House.com (4944 pcs in stock). Octopart lists 2 distributors with real-time pricing and lead-time comparison. For prototype builds, LCSC offers the lowest unit price and ships within 24 hours to most regions.
Is MPVZ4006GW7U174 RoHS compliant and lead-free?
Yes, the MPVZ4006GW7U174 is RoHS compliant and lead-free per NXP's product page and distributor listings. The 8-DIP through-hole package uses a matte-tin finish on the leads, satisfying the EU RoHS 2/3 directive without exemption. The part is not AEC-Q100 qualified; for automotive pressure-sensing use, NXP offers AEC-Q100 alternatives in the MP3V5000 and MPXH6115 families.
What are the key specifications engineers should know about MPVZ4006GW7U174?
The MPVZ4006GW7U174 integrates a 0 to 6 kPa piezoresistive bridge with on-chip signal conditioning, delivers a 0.3 V to 4.6 V ratiometric analog output from a 5.0 V supply, and operates across -40 °C to +125 °C in an 8-DIP module with 0.22 inch tube port. Accuracy, supply current, and response time specifics come from the NXP datasheet; verify against the latest revision before finalizing designs where these margins matter.
MPVZ4006GW7U174 vs MPXV4006DP - which is better for weather station barometry?
For weather-station-style absolute barometric measurements below 6 kPa differential, the MPVZ4006GW7U174 is the better fit because it can be referenced to a sealed cavity or vented port to provide a stable bias pressure. The MPXV4006DP is a differentiator sensor with dual ports; using it for absolute pressure requires plumbing gymnastics. Both share the 0.3-4.6 V output range, so the host ADC front-end is identical.
How do I connect MPVZ4006GW7U174 to an Arduino or microcontroller ADC?
Connect VDD (pin 2) to the Arduino 5 V rail, GND (pin 1) to ground, and VOUT (pin 3) directly to an analog input pin. Add a 100 nF ceramic decoupling capacitor within 5 mm of VDD and 10 μF bulk capacitance if the supply is shared with noisy loads. The ratiometric output means using the Arduino's AVCC as the ADC reference preserves absolute accuracy without external precision references.
What MEMS process technology does MPVZ4006GW7U174 use?
The MPVZ4006GW7U174 is built on NXP's (formerly Freescale's) monolithic silicon MEMS process, in which the piezoresistive strain-gauge bridge and CMOS signal-conditioning ASIC are fabricated side-by-side on the same silicon substrate. This monolithic integration is what enables the part's small 8-DIP module size, low cost, and on-chip temperature compensation - a key reason the MPVZ4006 family replaced older hybrid pressure-sensor modules.

Datos de referencia de ingeniería para MPVZ4006GW7U174 — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose the MPVZ4006GW7U174 when the application needs a calibrated 0 to 6 kPa differential pressure sensor with an inline vertical 0.22 in tube port for hose connection, ratiometric 0.3-4.6 V output, and the convenience of a fully integrated signal chain on a 5 V supply. It is the default choice for HVAC VAV controllers, consumer appliance water-level sensing, and weather-station barometry where the same PCB host ADC reference also powers the sensor. If your design needs an axial port for manifold mounting, switch to MPXV4006GP (same electrical spec). If you need a dual-port differential sensor, switch to MPXV4006DP. For automotive or AEC-Q100 applications, the MPVZ4006GW7U174 is not qualified; use NXP's automotive MPS-series sensors such as MP3V5000 in those designs.

Comparación con alternativas

Parámetro Este producto MPVZ4006GW7U MPVZ4006GW6U MPXV4006GP MPXV4006DP MPXV4006GVP
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 8-DIP Module (0.22 in tube) 8-DIP Module (0.22 in tube) 8-DIP Module (0.22 in tube) 8-DIP Module (axial port) 8-DIP Module (dual port) 8-DIP Module (vertical port)
Pressure Range 0 to 6 kPa 0 to 6 kPa 0 to 6 kPa 0 to 6 kPa 0 to 6 kPa 0 to 6 kPa
Output Voltage 0.3 V to 4.6 V 0.3 V to 4.6 V 0.3 V to 4.6 V 0.3 V to 4.6 V 0.3 V to 4.6 V 0.3 V to 4.6 V
Supply Voltage 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V
Operating Temperature -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C
Port Type Vertical male tube 0.22 in Vertical male tube 0.22 in Vertical male tube 0.22 in Axial horizontal port Dual horizontal ports Vertical port (small form)
Mounting Type Through-Hole (DIP) Through-Hole (DIP) Through-Hole (DIP) Through-Hole (DIP) Through-Hole (DIP) Through-Hole (DIP)
RoHS Compliance Compliant Compliant Compliant Compliant Compliant Compliant

Diferenciadores clave

  • Vertical 0.22 in tube port orientation (frente a MPXV4006GP)
  • Drop-in compatible with same MPVZ4006 family parts (frente a MPVZ4006GW7U)
  • Ratiometric output for ADC-synchronized measurement (frente a MPXV4006DP)
  • Integrated temperature compensation (frente a Discrete bridge sensor designs)

Notas de diseño

Power the MPVZ4006GW7U174 from the same well-regulated 5 V rail that supplies the host ADC reference. Because the sensor output is ratiometric to VDD, any 5 % supply tolerance directly translates into a 5 % absolute pressure error when the host ADC uses an independent reference. Place a 100 nF ceramic decoupling capacitor within 5 mm of the VDD pin (pin 2) and 10 μF bulk capacitance if the rail is shared with switching loads or relays. Estimated: assuming a switching regulator is in the same system, ripple above 50 mV on VDD will introduce ratiometric output distortion; use a linear post-regulator or LC filter if the source is noisy.

Route the analog VOUT trace (pin 3) away from digital and switching-node traces by at least 3 mm, and ground the unused pins to a quiet analog ground that ties back at one point to the system ground. The 8-DIP module body is the pneumatic seal, so do not let flux or conformal coating migrate into the tube port. When using a vertical-mount sensor on a horizontal PCB, add a mechanical support bracket to absorb the bend-load that the tube would otherwise apply to the through-hole leads. NXP's application hints suggest a 15 mm minimum keep-out under the tube port for incoming hose fitting access.

Estimated: with a 12-bit ADC reading 0.3-4.6 V across a 5 V reference, the per-LSB step is about 1.07 mV, corresponding to about 1.4 Pa at full-scale. To preserve that resolution, keep sensor bandwidth no higher than 2x the ADC sample rate by adding an RC filter (1 kΩ + 100 nF = 159 Hz cutoff). Below 100 Hz, sensor thermal noise dominates; above 1 kHz, pneumatic and electrical pickup can degrade SNR. Tube resonance typically occurs near 500 Hz for 100 mm hose lengths, so avoid placing the cutoff in that band.

Two common pitfalls: (1) using an external op-amp after the sensor output, which adds offset and noise; the integrated signal chain is calibrated at the factory and amplifies anywhere downstream will degrade the datasheet accuracy. (2) Leaving pins 4 through 8 floating; while these are no-connect on the sensor, leaving them open on the PCB can couple noise into the VOUT pin through capacitive coupling - tie them to ground or VDD on the PCB layout for best noise performance. NXP reference designs show all four NC pins grounded.

Información de cumplimiento

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Qualified
Libre de plomo
Yes
Libre de halógenos
Yes
Minerales en conflicto
Compliant

RoHS compliant and lead-free per NXP product page. Not AEC-Q100 qualified; for automotive pressure-sensor designs use NXP's MPS-series AEC-Q100 sensors. REACH compliance asserted; conflict-minerals reporting compliant per US Dodd-Frank act.

Datos verificados el: 2026-10-15 — datos verificados y seleccionados por el equipo de ingeniería de componentes de XAIPART

Búsquedas relacionadas

MPVZ4006GW7U174 datasheet MPVZ4006GW7U174 price NXP MPVZ4006GW7U174 pressure sensor 6 kPa pressure sensor 5V analog output DIP-8 pressure sensor tube port MPVZ4006GW7U174 HVAC VAV sensor MPVZ4006GW7U174 vs MPXV4006GP MPVZ4006GW7U174 drop-in replacement buy MPVZ4006GW7U174 online MPVZ4006GW7U174 pinout DIP-8 NXP piezoresistive pressure sensor 6kPa MPVZ4006GW7U174 stock LCSC JLCPCB what is the operating pressure range of MPVZ4006GW7U174 MPVZ4006GW7U174 Arduino wiring MPVZ4006GW7U174 weather station barometric

Componentes & términos relacionados

NXP Semiconductors Freescale Semiconductor MPVZ4006GW7U174 MPVZ4006GW7U MPVZ4006GW6U MPXV4006GP MPXV4006DP MPXV4006GVP piezoresistive pressure sensor pressure sensor MEMS sensor Wheatstone bridge signal conditioning ASIC ratiometric output 0 to 6 kPa 0.3 V to 4.6 V 8-DIP module HVAC VAV controller barometric pressure RoHS AEC-Q100 REACH Pneumatic control
RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
Total: $0.00 USD
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ