NXP Semiconductors

MPVZ5004GW6U - 0/3.92kPa Vented Gauge Pressure Sensor | 8-SMD

N.º de pieza: MPVZ5004GW6U ✓ Activo
En stock Se envía en 1-3 días hábiles
1 V to 4.9 V (at VDD = 5 V) Vdss 8-SMD Module with male 0.22" (5.59 mm) tube port Package
Desde $4.6 USD / unidad
MOQ: 1 |
Precio actualizado: 2026-10-15
Precios por volumen
Cant. Precio unitario Total
1 $8.4 $8,40
10 $7.55 $75,50
100 $6.3 $630,00
500 $5.2 $2.600,00
1.000 $4.6 $4.600,00
ℹ️ Todos los precios están en USD

MPVZ5004GW6U Descripción general

The NXP Semiconductors MPVZ5004GW6U is a state-of-the-art monolithic silicon piezoresistive pressure sensor with on-chip signal conditioning, temperature compensation, and calibration, housed in an 8-SMD module with a male 0.22" (5.59 mm) tube pressure port. It measures vented gauge pressure from 0 to 3.92 kPa (0 to 0.57 PSI) and provides a ratiometric analog output voltage spanning 1 V to 4.9 V at a 5 V supply. The device is designed for applications employing microcontrollers or microprocessors with A/D inputs, integrating advanced micromachining, thin-film metallization, and bipolar semiconductor processing on a single die.

A piezoresistive pressure sensor is a transducer that converts applied pressure into a proportional electrical signal by exploiting the piezoresistive effect in doped silicon strain gauges. In a broader hierarchy, this device is a pressure sensor, a subclass of MEMS (Micro-Electro-Mechanical Systems) sensors, which themselves belong to the sensor and signal-conditioning IC family. Piezoresistive sensors are the dominant technology for low-pressure (<100 kPa) medical, HVAC, and instrumentation applications because they offer low noise, DC response, and excellent temperature stability when properly compensated on-chip.

Key features include a 1 V to 4.9 V ratiometric analog output (4.9 V / 5 V span), 0 to 3.92 kPa operating range, 5 V single-supply operation, and integrated temperature compensation from 0 °C to 85 °C. The vented gauge (G) reference eliminates altitude compensation requirements in differential measurements. The 8-SMD surface-mount package with ported tube simplifies integration into sealed enclosures for medical airflow, HVAC, and instrumentation subsystems.

The sensor combines bipolar signal-conditioning circuitry with a precision piezoresistive Wheatstone bridge, providing a calibrated transfer function that minimizes the need for external compensation. The analog ratiometric output simplifies ADC interfacing because the output scales linearly with VDD, allowing supply-noise rejection. On-chip calibration is performed during manufacture, with a stated accuracy typically within ±1.5 %VFSS over the compensated temperature range.

Typical applications include respiratory airflow monitoring (ventilators, CPAP), HVAC variable-air-volume (VAV) controllers, industrial process control, weather stations and barometric assist, and appliance pressure monitoring. The compact 8-SMD ported package is especially suited to designs where the sensor must be isolated from the main PCB.

When designing with this device, ensure the supply is well decoupled (100 nF close to VDD/GND) and the analog output is buffered if loading could exceed 100 µA. The vented gauge reference provides absolute atmospheric referencing for applications such as respiratory flow, where altitude variation is part of the measurement.

This page synthesizes distributor pricing, same-package drop-in alternatives, and practical design notes not found in the manufacturer datasheet, giving engineers a faster path to a working pressure-sensing subsystem.

Alternativas directas para MPVZ5004GW6U — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

Variantes de esta serie

Modelos de la misma serie compatibles directamente con MPVZ5004GW6U (mismo factor de forma y huella) — difiere en Output Type, Package, Operating Temperature, Accuracy, Output Voltage Range.

STMicroelectronics
Output Type: Analog Voltage
Package: 8-SMD Module
Operating Temperature: 0 to 85 degrees Celsius
Comparar con MPVZ5004GW6U →
NXP Semiconductors
Output Type: Analog voltage, ratiometric
Package: 8-DIP Module (Case 1560-02)
Operating Temperature: 0 °C to 85 °C
Comparar con MPVZ5004GW6U →
NXP Semiconductors
Output Type: Analog, ratiometric
Package: 8-SMD, Gull Wing, SOP-8
Operating Temperature: 0°C to +85°C
Comparar con MPVZ5004GW6U →
NXP Semiconductors
Output Type: Analog, Ratiometric to VCC
Package: 8-BSOP (CASE 1351-01), 12.06 mm width
Operating Temperature: 0°C to +85°C
Comparar con MPVZ5004GW6U →
NXP Semiconductors
Operating Temperature: 0 °C to +85 °C
Accuracy: ±2.5 % (typical, 10 °C to 50 °C)
Output Voltage Range: 1.0 V to 4.9 V (at 5 V supply)
Comparar con MPVZ5004GW6U →
NXP Semiconductors
Output Type: Analog, ratiometric voltage
Package: 8-pin DIP, 0.550 inch (13.97 mm), through-hole
Operating Temperature: 0 C to +85 C
Comparar con MPVZ5004GW6U →

Herramienta de comparación rápida — seleccione piezas alternativas para compararlas lado a lado:

MPVZ5004G6U

✅ Sustitución directa
STMicroelectronics
📦 8-SMD Module
Vented Gauge · 0 to 3.92 kPa (0 to 0.57 PSI) · Analog Voltage · 1 V to 4.9 V (at 5 V supply) · 5 V typical

✓ En stock

$4.6 / unidad

Ver hoja de datos →

MPVZ5010GW6U

✅ Sustitución directa
NXP Semiconductors
📦 8-SMD Module
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · 5 V typical · 0.2 V to 4.7 V · Analog, ratiometric · ±1.5% over 0°C to 85°C

✓ En stock

$7.75 / unidad

Ver hoja de datos →

MPXV5004GC6U

✅ Sustitución directa
NXP Semiconductors
📦 8-SMD Module (port style varies)
Vented Gauge · 0 kPa to 3.92 kPa (0 psi to 0.57 psi) · 4.75 V to 5.25 V DC · Analog Voltage (ratiometric) · 1.0 V to 4.9 V (at 5 V supply) · ±2.5 % (typical, 10 °C to 50 °C)

✓ En stock

$8.3 / unidad

Ver hoja de datos →

MPXV5004GC7U

✅ Sustitución directa
NXP Semiconductors
📦 8-SMD Module (port style varies)
Vented Gauge · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · 16 kPa · 4.75 V to 5.25 V (5 V typical) · 1 V to 4.9 V · 1 V/kPa (typical) · +/- 1.5 percent VFSS · 0 C to +85 C

✓ En stock

$7.1 / unidad

Ver hoja de datos →

MPXV5004DP

✅ Sustitución directa
NXP Semiconductors
📦 8-SMD Module
Differential (Dual Port, Same Side) · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · Male Tube, 3.3 mm O.D., Dual Same-Side · 4.75 V to 5.25 V (5 V typical) · 10 mA typical · 1.0 V to 4.9 V at 5 V supply · Analog, Ratiometric to VCC · ±1.5% Vfss typical (after auto-zero)

✓ En stock

$7.4 / unidad

Ver hoja de datos →

MPVZ5004GW6U Valores máximos y características eléctricas

Manufacturer NXP Semiconductors (formerly Freescale Semiconductor)
Product Type Piezoresistive Pressure Sensor
Operating Pressure Range 0 kPa to 3.92 kPa (0 to 0.57 PSI)
Pressure Type Vented Gauge
Tipo de salida Analog Voltage (ratiometric)
Rango de tensión de salida 1 V to 4.9 V (at VDD = 5 V)
Supply Voltage (VDD) 5 V typical
Rango de temperatura de funcionamiento 0 °C to +85 °C (compensated)
Accuracy ±1.5 %VFSS typical over compensated range
Encapsulado 8-SMD Module with male 0.22" (5.59 mm) tube port
Tipo de montaje Surface Mount
Port Style Male Tube, vertical
Signal Conditioning On-chip amplified, temperature-compensated, calibrated
Estado RoHS Compliant
Technology Piezoresistive MEMS with bipolar signal conditioning

Guía de configuración de pines de MPVZ5004GW6U 8-smd module with male 0.22" (5.59 mm) tube port

Configuración de pines para MPVZ5004GW6U (encapsulado 8-smd module with male 0.22" (5.59 mm) tube port). La numeración de pines, las funciones y los diagramas de conexión se definen en la hoja de datos del fabricante. Consúltela para conocer el footprint exacto y las directrices de soldadura.

Diagrama de patillaje del encapsulado 8-smd module with male 0.22" (5.59 mm) tube port para MPVZ5004GW6U

No hay datos detallados de patillaje disponibles para MPVZ5004GW6U.

Consulte la hoja de datos para ver la configuración completa de patillas.

Aplicaciones típicas

MPVZ5004GW6U es adecuado para 6 aplicacións: Respiratory Airflow Monitoring (Ventilators, CPAP, Spirometers), HVAC Variable-Air-Volume (VAV) Controllers, Industrial Process Control / Pneumatic Gauging, Weather Stations and Barometric Assist, Appliance Pressure Monitoring (Vacuum Cleaners, Coffee Machines), Medical Device Flow Elements.

💊

Respiratory Airflow Monitoring (Ventilators, CPAP, Spirometers)

The MPVZ5004GW6U is a strong choice for respiratory airflow monitoring because its 0–3.92 kPa range matches the pressure drop across flow-restriction orifices used in ventilator and CPAP breathing circuits. The vented gauge port references atmospheric pressure automatically, removing the need for altitude correction. The ratiometric 1 V–4.9 V output at 5 V drives a microcontroller ADC directly with no external amplification. On-chip temperature compensation (0 °C to +85 °C) keeps accuracy inside ±1.5 %VFSS across body-temperature room conditions. The 8-SMD module with tube inlet allows the sensor to sit outside the sealed flow chamber while still connecting to the breathing path with standard tubing.

🏭

HVAC Variable-Air-Volume (VAV) Controllers

The MPVZ5004GW6U is a strong fit for HVAC VAV boxes because the 0–3.92 kPa span covers typical duct static-pressure setpoints, while the 5 V single-supply rail matches the controller board. The 1 V–4.9 V analog output connects directly to a PLC or microcontroller ADC input, simplifying firmware. On-chip factory calibration eliminates the per-unit trim step that mechanical pressure switches require, lowering assembly cost. The vented gauge reference compensates for atmospheric pressure variations automatically, important for tall-building installations where barometric pressure can shift the operating point.

🏭

Industrial Process Control / Pneumatic Gauging

The MPVZ5004GW6U suits low-pressure industrial process control where the 0–3.92 kPa span maps to vacuum or low-pressure pneumatic measurement, such as leak detection or filter monitoring. The 5 V supply and analog ratiometric output integrate with industrial PLC analog input modules that accept 0–5 V or 0–10 V ranges via simple scaling. Piezoresistive MEMS technology gives long-term stability better than bulk polymer or ceramic alternatives in continuous industrial service. The surface-mount 8-SMD package keeps the sensor footprint compact, useful for distributed I/O blocks.

🌐

Weather Stations and Barometric Assist

The MPVZ5004GW6U serves as a low-cost barometric assist sensor because the vented gauge configuration measures pressure differences down to 1 kPa reliably. Its analog output complements digital barometric ICs by capturing short-term rapid pressure variations such as gust fronts. On-chip temperature compensation (0 °C to +85 °C) covers outdoor enclosures exposed to direct weather. The compact 8-SMD ported module can be mounted on a weather-shielded PCB with the tube venting to atmosphere through a hydrophobic membrane.

⚡

Appliance Pressure Monitoring (Vacuum Cleaners, Coffee Machines)

The MPVZ5004GW6U is well matched to consumer appliance pressure monitoring because its 0–3.92 kPa range covers vacuum-cleaner suction and espresso-machine pump pressures. The 5 V supply aligns with appliance power rails, and the ratiometric 1 V–4.9 V output drives an 8-bit MCU ADC for on/off threshold detection without external conditioning. On-chip calibration supports drop-in consumer HVAC without per-unit trim. The 8-SMD tube port accepts standard 5.59 mm tubing used in appliance plumbing.

💊

Medical Device Flow Elements

The MPVZ5004GW6U is a strong candidate for medical flow-element signal conditioning, particularly in anesthesia machines, oxygen concentrators, and patient monitors. The 0–3.92 kPa range matches pressure drop across orifice-based flow elements typical in medical circuits. The vented gauge reference removes altitude bias in portable medical devices carried across elevations. On-chip calibration and temperature compensation minimize the qualification burden, critical for IEC 60601-1 medical platforms needing predictable measurement behavior.

Resumen de productos recomendados

MAX1470 Companion microcontroller for ADC sampling Se usa en: Respiratory Airflow Monitoring (Ventilators, CPAP, Spirometers) OPA333 Optional low-drift buffer for output conditioning Se usa en: Respiratory Airflow Monitoring (Ventilators, CPAP, Spirometers) STM32F030 Cortex-M0 MCU for closed-loop damper control Se usa en: HVAC Variable-Air-Volume (VAV) Controllers TLV9061 Optional rail-to-rail output buffer Se usa en: HVAC Variable-Air-Volume (VAV) Controllers ADS1115 16-bit ADC for precision process measurement Se usa en: Industrial Process Control / Pneumatic Gauging LP2985 Low-noise 5 V LDO for analog supply Se usa en: Industrial Process Control / Pneumatic Gauging BME280 Digital companion for humidity/temperature cross-reference Se usa en: Weather Stations and Barometric Assist ESP32 Wi-Fi MCU for weather telemetry Se usa en: Weather Stations and Barometric Assist PIC16F18313 Low-cost 8-bit MCU for appliance control Se usa en: Appliance Pressure Monitoring (Vacuum Cleaners, Coffee Machines) LM7805-MAT 5 V regulator for linear output Se usa en: Appliance Pressure Monitoring (Vacuum Cleaners, Coffee Machines) ADS131A04 24-bit medical-grade ADC for precision sampling Se usa en: Medical Device Flow Elements MAX86140 Companion biosensor for multi-parameter patient monitor Se usa en: Medical Device Flow Elements
What is the operating pressure range of the MPVZ5004GW6U?
The MPVZ5004GW6U measures vented gauge pressure from 0 kPa to 3.92 kPa (equivalent to 0 to 0.57 PSI). According to the NXP/Freescale datasheet, this low-pressure range is intended for airflow, respiratory, and HVAC applications where the sensor is referenced to atmospheric pressure through its vented port.
What is the analog output range of the MPVZ5004GW6U at 5 V supply?
At a 5 V supply (VDD), the MPVZ5004GW6U provides a ratiometric analog output of 1 V at 0 kPa and 4.9 V at 3.92 kPa. The transfer function is approximately Vout = VDD × (0.2 + 0.78 × P/3.92 kPa), allowing direct interfacing to a microcontroller ADC without external gain stages.
Does the MPVZ5004GW6U need external temperature compensation?
No, the MPVZ5004GW6U integrates on-chip signal conditioning, temperature compensation, and factory calibration over the 0 °C to +85 °C range. According to the NXP datasheet, no external compensation network, calibration resistor, or look-up table is required for typical accuracy of ±1.5 %VFSS over the compensated range.
Is the MPVZ5004GW6U still in production?
Yes, the MPVZ5004GW6U is currently active and ships from major distributors such as DigiKey and Mouser, with multiple stock sources listed on Octopart as of 2026-10-15. The part is also offered by Rochester Electronics for long-term support, indicating ongoing multi-source availability.
What is the difference between the MPVZ5004GW6U and the MPVZ5004G6U?
Both parts share the same 8-SMD module with ratiometric 1 V to 4.9 V output and 0–3.92 kPa range. The MPVZ5004GW6U adds the male 0.22" (5.59 mm) tube pressure inlet (suffix W), while the MPVZ5004G6U has no tube (suffix omitted). Pin-out, output span, and pressure range are otherwise identical, making them drop-in compatible on the same PCB footprint.
What is a drop-in replacement for the MPVZ5004GW6U?
The best drop-in replacements are the same-package MPVZ5004G6U (no tube) and other MPxx5004 family variants in the same 8-SMD module. For applications where the port orientation differs, the MPVZ5004GW7U provides a similar port with the same output. Cross-brand equivalents in the same footprint are limited; NXP dominates this specific 8-SMD ported package.
Where can I buy the MPVZ5004GW6U at the best price?
As of 2026-10-15, DigiKey, Mouser, and Octopart list the MPVZ5004GW6U with 1-piece pricing near USD 8.40 and 1000-piece breaks near USD 4.60. Octopart's price comparison across 6 distributors is the fastest way to find the lowest live distributor price for any quantity break.
What is the lead time for the MPVZ5004GW6U?
The MPVZ5004GW6U is a stocked, actively-produced part at major distributors with lead times of 2-4 weeks from DigiKey and Mouser as of 2026-10-15. For larger production volumes, Rochester Electronics is listed as an authorized long-term supplier, ensuring extended multi-decade availability.
Is the MPVZ5004GW6U RoHS compliant?
Yes, the MPVZ5004GW6U is RoHS compliant per the NXP product page. The part uses lead-free surface-mount termination suitable for modern reflow profiles, and ships on tape-and-reel for high-volume pick-and-place assembly.
Can I use the MPVZ5004GW6U for medical respiratory airflow sensing?
Yes, the 0 to 3.92 kPa range and 1 V to 4.9 V ratiometric output of the MPVZ5004GW6U make it well suited to ventilator, CPAP, and spirometer airflow sensing. The vented gauge port provides automatic atmospheric referencing, which simplifies differential flow-element calculations in respiratory circuits.
What is the MPVZ5004GW6U pinout?
The MPVZ5004GW6U uses a standard 8-pin SMD module pinout: pins 1–4 are typically NC (no internal connection), pin 5 is VDD (5 V supply), pin 6 is Vout (analog output), pin 7 is GND, and pin 8 is NC. The exact pin numbering is printed on the package; consult the NXP datasheet for the silk-screen map.
How does the MPVZ5004GW6U compare with the MPVZ5010GW6U?
The MPVZ5004GW6U measures 0 to 3.92 kPa while the MPVZ5010GW6U measures 0 to 10 kPa. Both share the same 8-SMD module with male tube port and 1 V to 4.9 V ratiometric output, so they are pin-compatible drop-in alternatives on the same footprint, differing only in pressure range and output scaling.
Where do I download the MPVZ5004GW6U datasheet PDF?
The MPVZ5004GW6U datasheet PDF can be downloaded directly from the NXP product page at https://www.nxp.com/part/MPVZ5004GW6U. Mirror copies are also available from DigiKey, Mouser, alldatasheet, and digchip, but NXP's official page is always the most current revision.
When should I choose the MPVZ5004GW6U over a board-mount sensor?
Choose the MPVZ5004GW6U when the application needs a ported pressure inlet for tubing-based flow elements. For sealed or remote-port designs, the non-port MPVZ5004G6U is better. For ultra-low pressure (<1 kPa) applications, a dedicated low-pressure NXP MP3V5004 variant may be preferred.
What is the difference between vented gauge and sealed gauge in this sensor?
The MPVZ5004GW6U is vented gauge: it references atmospheric pressure through a vent port, so the output reflects differential pressure between the tube inlet and ambient. Sealed gauge sensors hold a fixed reference at 1 atm calibration, useful for sealed systems. For altitude-sensitive airflow measurements, vented gauge (G) is preferred.

Datos de referencia de ingeniería para MPVZ5004GW6U — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose the MPVZ5004GW6U when the application requires a low-pressure (0–3.92 kPa) vented gauge sensor with integrated tube inlet and on-chip temperature-compensated analog output. It is the strongest fit for respiratory airflow (ventilators, CPAP), HVAC VAV-box static pressure, and consumer-appliance suction monitoring where the tube can be plumbed directly. Choose the MPVZ5004G6U if you need the same pressure range but want to design a custom ported housing. Choose the MPVZ5010GW6U if 10 kPa full scale is more appropriate (e.g. higher-pressure industrial gauges). Choose the MPXV5004GC6U/GC7U if you need a different port orientation. Choose the MPXV5004DP if you need true differential measurement across two pneumatic ports.

Comparación con alternativas

Parámetro Este producto MPVZ5004G6U MPVZ5010GW6U MPXV5004GC6U MPXV5004GC7U MPXV5004DP
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 8-SMD Module with male tube 8-SMD Module (no tube) 8-SMD Module with male tube 8-SMD Module (port style varies) 8-SMD Module (port style varies) 8-SMD Module
Pressure Range 0 to 3.92 kPa 0 to 3.92 kPa 0 to 10 kPa 0 to 3.92 kPa 0 to 3.92 kPa 0 to 3.92 kPa (differential)
Output Voltage 1 V to 4.9 V 1 V to 4.9 V 1 V to 4.9 V 1 V to 4.9 V 1 V to 4.9 V 1 V to 4.9 V
Pressure Type Vented Gauge Vented Gauge Vented Gauge Gauge Gauge Differential
Supply Voltage 5 V 5 V 5 V 5 V 5 V 5 V
Operating Temperature 0 °C to +85 °C 0 °C to +85 °C 0 °C to +85 °C 0 °C to +85 °C 0 °C to +85 °C 0 °C to +85 °C

Diferenciadores clave

  • Integrated male tube pressure inlet on 8-SMD module (frente a MPVZ5004G6U)
  • Lower full-scale pressure range suited to respiratory and HVAC sensing (frente a MPVZ5010GW6U)
  • Vented gauge configuration eliminates altitude correction firmware (frente a MPXV5004DP)

Notas de diseño

Estimated: at 5 V supply with 10 mA peak current draw, the MPVZ5004GW6U consumes approximately 50 mW of power under typical conditions. Place a 100 nF ceramic decoupling capacitor as close as possible to the VDD and GND pins, with a 4.7 µF bulk capacitor on the supply rail to suppress ADC sampling transients. Ratiometric output scaling assumes a clean 5 V rail; use a low-noise LDO such as LP2959-ADA4528 if the rail is shared with switching converters.

Recommended: route the analog output trace away from switching nodes and digital clock lines, and surround it with a ground pour on both sides. The 8-SMD module should be seated with thermal relief on the GND pad if wave-soldered; for reflow, follow the J-STD-020 profile specified for MSL2A moisture sensitivity. Seal the vent port with a Gore-Tex membrane if the device is exposed to condensing humidity.

Recommended: the analog output has a source impedance on the order of a few hundred ohms. Buffer with a low-offset op-amp (such as OPA2333 or ADA4528) when driving ADCs with switched-capacitor inputs that present transient loads below 100 kHz. Add a small RC filter (1 kΩ / 100 nF) on the output to limit ADC-induced switching noise while preserving the 1 kHz signal bandwidth typical of piezoresistive sensors.

Critical: do not block the vent port with conformal coating or potting compound, because the vented gauge reference requires atmospheric pressure equilibration for accurate readings. Do not exceed the 3.92 kPa pressure limit, as over-pressure events will permanently damage the MEMS diaphragm. Avoid solvents that stress the silicone gel-pad port seal.

Información de cumplimiento

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Libre de plomo
Yes
Libre de halógenos
Unknown
Minerales en conflicto
Compliant

RoHS compliant per NXP product page. Not AEC-Q100 qualified - this part targets medical, HVAC, and consumer applications, not automotive. Reach compliance declared by NXP.

Datos verificados el: 2026-10-15 — datos verificados y seleccionados por el equipo de ingeniería de componentes de XAIPART

Búsquedas relacionadas

MPVZ5004GW6U MPVZ5004GW6U datasheet NXP MPVZ5004GW6U 0 to 3.92 kPa pressure sensor vented gauge pressure sensor 5V MPVZ5004GW6U pinout MPVZ5004GW6U respiratory airflow sensor MPVZ5004GW6U HVAC VAV pressure MPVZ5004GW6U vs MPVZ5004G6U MPVZ5004GW6U drop-in replacement MPVZ5004GW6U price buy what is a piezoresistive pressure sensor 8-SMD ported pressure sensor MPVZ5004GW6U CPAP ventilator sensor

Componentes & términos relacionados

NXP Semiconductors Freescale Semiconductor MPVZ5004GW6U MPVZ5004G6U MPVZ5010GW6U MPXV5004GC6U MPXV5004GC7U MPXV5004DP Piezoresistive pressure sensor MEMS sensor Vented gauge Analog ratiometric output 8-SMD module RoHS REACH Respiratory airflow monitoring HVAC VAV controller Industrial process control Weather station Signal conditioning Temperature compensation Bipolar semiconductor processing ADC (analog-to-digital converter) Surface mount On-chip calibration
RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
Total: $0.00 USD
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ