NXP Semiconductors

MPX2053DP - 50 kPa Differential Pressure Sensor | NXP | 4-SIP Module

N.º de pieza: MPX2053DP ✓ Activo
En stock Se envía en 1-3 días hábiles
0 mV to 40 mV Vdss 4-SIP Module (Case 344-15) Package
Desde $12.95 USD / unidad
MOQ: 1 |
Precio actualizado: 2026-10-15
Precios por volumen
Cant. Precio unitario Total
1 $24.5 $24,50
10 $21.8 $218,00
100 $18.6 $1.860,00
500 $15.4 $7.700,00
1.000 $12.95 $12.950,00
ℹ️ Todos los precios están en USD

MPX2053DP Descripción general

The NXP MPX2053DP is a 50 kPa (7.25 PSI) on-chip temperature-compensated and calibrated silicon piezoresistive pressure sensor housed in a 4-SIP module with dual barbed ports for differential pressure measurement. It delivers a linear, ratiometric analog voltage output of 0 mV to 40 mV at 10 V excitation, corresponding to a sensitivity of 0.8 mV/kPa over a 0 kPa to 50 kPa differential operating range. The monolithic silicon diaphragm integrates the strain gauge and thin-film resistor network on a single die.

A piezoresistive pressure sensor is a MEMS device whose Wheatstone-bridge strain gauges are diffused into a silicon diaphragm that flexes under applied pressure, producing a differential output voltage proportional to the pressure differential across its two ports. In the broader sensor hierarchy, the MPX2053DP sits within pressure sensors -> MEMS sensors -> transducers -> sensors, and is commonly interfaced to instrumentation amplifiers or ADC front ends. Temperature compensation and span/offset calibration are performed by laser-trimmed thin-film resistors on-chip, eliminating the need for external compensation networks in many applications.

The MPX2053DP features a typical full-scale span of 40 mV at 10 V supply, a maximum offset of ±1.0 mV, and a response time of 1.0 ms. The device operates from a single 10 V typical supply (maximum 16 V) and is specified over 0 °C to +85 °C. Ratiometric output means the span scales linearly with supply voltage, simplifying ADC interfacing. The dual-port SIP package (Case 344-15) accepts 4.93 mm (0.19 inch) tubing for pneumatic or hydraulic differential measurement.

Typical applications include medical instrumentation (respiratory monitors, ventilators, blood pressure monitors), HVAC airflow and filter monitoring, industrial process control, level detection, and barometric differential measurement. The 0.8 mV/kPa sensitivity makes the device well-suited for low-pressure biomedical and environmental sensing.

Designers should use a high-precision instrumentation amplifier (such as an INA126 or AD620) to boost the 40 mV full-scale output to a usable 0-5 V or 4-20 mA range. Add 100 nF supply decoupling close to the sensor pins and a resistive bridge-drive configuration if ratiometric ADC sampling is required.

This page synthesizes distributor pricing, drop-in alternative cross-references, and practical signal-conditioning guidance not found in the manufacturer datasheet alone.

Alternativas directas para MPX2053DP — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

Variantes de esta serie

Modelos de la misma serie compatibles directamente con MPX2053DP (mismo factor de forma y huella) — difiere en Output Type, Technology, Operating Temperature, Supply Voltage, Operating Pressure Range.

NXP Semiconductors
Output Type: Analog voltage, Wheatstone bridge (mV level)
Technology: Piezoresistive (silicon strain gauge bridge)
Operating Temperature: -40 °C to +125 °C
Comparar con MPX2053DP →
STMicroelectronics
Output Type: Analog, Wheatstone bridge
Technology: Silicon piezoresistive, laser-trimmed
Operating Temperature: -40C to +125C
Comparar con MPX2053DP →
NXP Semiconductors
Output Type: Wheatstone Bridge (analog voltage, ratiometric)
Technology: Silicon piezoresistive (MEMS)
Operating Temperature: 0°C to +85°C
Comparar con MPX2053DP →
NXP Semiconductors
Output Type: Analog mV (Wheatstone Bridge)
Technology: Silicon piezoresistive, on-chip temperature compensation
Operating Temperature: 0C to +85C (compensated)
Comparar con MPX2053DP →
NXP Semiconductors
Output Type: Analog Wheatstone Bridge (ratiometric mV)
Technology: On-chip Temperature Compensated Silicon
Operating Pressure Range: 0 kPa to 100 kPa (0 PSI to 14.5 PSI)
Comparar con MPX2053DP →

Herramienta de comparación rápida — seleccione piezas alternativas para compararlas lado a lado:

MPX2050DP

✅ Sustitución directa
📦 4-SIP Module (Case 344-15)
lower sensitivity 0.4 mV/kPa vs 0.8 mV/kPa (-50%) but same 4-SIP package, pin-compatible

📋 Alternativa de referencia (no en el catálogo)

MPX2052DP

✅ Sustitución directa
📦 4-SIP Module (Case 344-15)
slightly different calibration range but same 4-SIP Case 344-15 package, pin-compatible

📋 Alternativa de referencia (no en el catálogo)

MPX2010DP

✅ Sustitución directa
NXP Semiconductors
📦 4-SIP Module (Case 344-15)
Differential Pressure Sensor · 0 to 10 kPa (0 to 1.45 PSI) · Piezoresistive (silicon strain gauge bridge) · Analog voltage, Wheatstone bridge (mV level) · 25 mV at 10 V excitation · 0 mV nominally (±1.0 mV max) · 10 V DC typical (max 16 V) · ±0.05% (typ)

✓ En stock

$8.5 / unidad

Ver hoja de datos →

MPX2202DP

✅ Sustitución directa
NXP Semiconductors
📦 4-SIP Module (Case 344-15)
0 to 200 kPa (0 to 29.01 PSI) · Differential (dual port, tube inlet) · 10 V typical · 40 mV typical at 10 V supply · 0 mV typical · 1.0% typical · 2.0% maximum · 0 C to 85 C

✓ En stock

$25.14 / unidad

Ver hoja de datos →

MPX2100DP

✅ Sustitución directa
NXP Semiconductors
📦 4-SIP Module (Case 344-15)
Differential · 0 kPa to 100 kPa (0 to 14.5 psi) · 40 mV (at 10 V excitation) · 1% typical · 10 V DC typical

✓ En stock

$5.95 / unidad

Ver hoja de datos →

MPX2053DP Valores máximos y características eléctricas

Pressure Type Differential
Operating Pressure Range 0 kPa to 50 kPa (0 PSI to 7.25 PSI)
Sensitivity 0.8 mV/kPa (typical)
Full-Scale Span (10 V supply) 0 mV to 40 mV
Tipo de salida Analog voltage, ratiometric
Tensión de alimentación 10 V typical, 16 V maximum
Maximum Offset ±1.0 mV
Response Time 1.0 ms (typical)
Temperatura de funcionamiento 0 °C to +85 °C
Port Configuration Dual barbed ports, 0.19 in (4.93 mm) tube
Encapsulado / Carcasa 4-SIP Module (Case 344-15)
Tipo de montaje Through-hole, PCB mount
Technology Silicon piezoresistive MEMS, on-chip temperature compensated
Estado RoHS Compliant
Lead-Free Yes

Configuración de pines de MPX2053DP

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pin 1 VS — Supply voltage (10 V typical, 16 V max)
Pin 2 GND — Ground reference
Pin 3 VOUT — Differential output positive (0-40 mV at 10 V)
Pin 4 VOUT2 — Differential output negative / complementary half-bridge

Aplicaciones típicas

MPX2053DP es adecuado para 6 aplicacións: Medical Respiratory Flow Monitoring, HVAC Filter and Duct Pressure Monitoring, Industrial Process Control and Level Detection, Barometric and Altitude Measurement, Blood Pressure Monitor Front-End, Environmental Air Quality and Flow Sensing.

💊

Medical Respiratory Flow Monitoring

The MPX2053DP's 0-50 kPa differential range and 0.8 mV/kPa sensitivity make it well suited for spirometry and respiratory monitoring where flow head is created by a pneumotachograph. In this role, the sensor measures the pressure drop across a flow restriction, which an external circuit converts to volumetric flow. Its 1 ms response time resolves individual breath cycles, and on-chip temperature compensation keeps readings stable across 0 °C to +85 °C ambient shifts in clinical and home-care equipment.

🏭

HVAC Filter and Duct Pressure Monitoring

Commercial HVAC systems use differential pressure sensors to monitor air filter loading and duct static pressure. The MPX2053DP's 7.25 PSI full-scale and 0-50 kPa range cover the typical 0.1-2.0 inch H2O pressure drops used for filter diagnostics, while its dual barbed ports accept standard 0.19 inch tubing for inline duct installation. Ratiometric output simplifies the ADC interface when driven from the same 10 V reference, eliminating supply-drift errors during long measurement campaigns.

🏭

Industrial Process Control and Level Detection

The MPX2053DP measures differential pressure in closed vessels, hydrostatic tank levels, and pipe flow via orifice plates. Its 50 kPa range covers most low-pressure industrial process loops below 7 PSI, and its 4-93 mm dual-port SIP accepts the standard pneumatic fittings found in process plants. The ratiometric 0-40 mV output is easily scaled by an isolated 4-20 mA transmitter front-end for plant-wide SCADA integration and certified regulators.

✈️

Barometric and Altitude Measurement

For portable weather stations and drone altimeters, the MPX2053DP can be configured as a sealed-gauge reference with one port capped to ambient, providing a low-cost barometric pressure measurement. Although designed primarily for differential sensing, the single-port reference technique yields useful readings up to 50 kPa above the sealed reference. Combined with a temperature sensor, the device enables altitude calculation for unmanned aerial vehicles and recreational GPS instruments.

💊

Blood Pressure Monitor Front-End

The MPX2053DP is a long-established choice for electronic sphygmomanometers, where its 0-50 kPa range covers cuff pressures up to 300 mmHg. The 0.8 mV/kPa sensitivity yields sufficient resolution to resolve systolic and diastolic events when amplified by an instrumentation amplifier. On-chip temperature compensation and laser-trimmed calibration deliver accuracy suitable for consumer health devices and ambulatory blood pressure monitors used by patients at home.

🧩

Environmental Air Quality and Flow Sensing

Building automation and indoor air-quality systems use differential pressure sensors to detect airflow across ventilation grilles, fan operation, and cleanroom pressure cascades. The MPX2053DP's dual barbed ports accept standard pneumatic tubing for inline measurement, and its 1 ms response enables detection of rapid fan startups. Ratiometric output allows direct ADC sampling using the same reference that drives the sensor, simplifying the BOM and improving long-term stability.

Resumen de productos recomendados

INA128 Instrumentation amplifier for 40 mV full-scale signal conditioning Se usa en: Medical Respiratory Flow Monitoring ADS1115 16-bit ADC for ratiometric pressure digitization Se usa en: Medical Respiratory Flow Monitoring MAX31865 RTD-to-digital converter for combined temperature/pressure readout Se usa en: HVAC Filter and Duct Pressure Monitoring INA126 Low-noise instrumentation amplifier for 4-20 mA loop output stage Se usa en: Industrial Process Control and Level Detection BMP280 Companion barometric pressure sensor for higher-altitude reference Se usa en: Barometric and Altitude Measurement AD620 Low-drift instrumentation amplifier for cuff pressure signal chain Se usa en: Blood Pressure Monitor Front-End MAX4475 Low-noise op-amp for pulse-oscillometric detection circuit Se usa en: Blood Pressure Monitor Front-End SHT31 Companion humidity/temperature sensor for combined air-quality module Se usa en: Environmental Air Quality and Flow Sensing
What is the operating pressure range of the MPX2053DP?
The MPX2053DP operates from 0 kPa to 50 kPa (0 PSI to 7.25 PSI) differential pressure. According to the NXP MPX2053 datasheet, the device provides a linear ratiometric analog output of 0 mV to 40 mV at a 10 V supply across this full range, with a sensitivity of 0.8 mV/kPa. It is intended for low-pressure differential applications such as medical respiratory and HVAC monitoring.
Where can I download the MPX2053DP datasheet PDF?
The official MPX2053DP datasheet is hosted on NXP's website at https://www.nxp.com/docs/en/data-sheet/MPX2053.pdf. The document covers electrical characteristics, mechanical dimensions for the 4-SIP Case 344-15 package, port tubing specifications, and reference circuits for signal conditioning. Mirror copies are also available on alldatasheet.com and digchip.com for backup reference.
What is the pinout of the MPX2053DP 4-SIP module?
The MPX2053DP is housed in a 4-pin SIP module (Case 344-15). Pin 1 is VS (supply voltage, 10 V typical), Pin 2 is GND, Pin 3 is VOUT (ratiometric analog output, 0-40 mV), and Pin 4 is VOUT2 (the complementary half-bridge output referenced to GND). Both output pins are used differentially by an external instrumentation amplifier to reject common-mode noise and supply ripple.
How much does the MPX2053DP cost?
As of 2026-10-15, the MPX2053DP lists at approximately $24.50 per unit at qty 1 on authorized distributors such as DigiKey and Mouser. Volume pricing drops to $18.60 at qty 100 and $12.95 at qty 1000. Third-party sourcing on LCSC starts near $1.00, but only NXP-authorized stock carries the full datasheet traceability and warranty.
Is the MPX2053DP in stock at major distributors?
Yes, the MPX2053DP is currently in stock at distributors including DigiKey, Mouser, Heisener (2,412 pieces reported), and Xecor. Lead time for direct NXP-authorized orders is typically 8-12 weeks, but distributor shelves support same-day shipping for small quantities. The part is listed as Active in NXP's product lifecycle, with no EOL announcement on file as of 2026-10-15.
What is the best drop-in replacement for the MPX2053DP?
The most direct drop-in equivalents are the NXP MPX2050DP (lower sensitivity variant in the same family) and MPX2052DP for applications accepting slightly different calibration. Both share the same Case 344-15 4-SIP package and identical pinout. For pin-compatible parts from other manufacturers, evaluate the Honeywell 24PC series with the same 0.5-1.0 inch port spacing after verifying electrical compatibility.
MPX2053DP vs MPX2050DP - which should I choose?
The MPX2053DP delivers 40 mV full-scale span (higher sensitivity, 0.8 mV/kPa) while the MPX2050DP delivers only 20 mV (lower sensitivity, 0.4 mV/kPa) at the same 10 V supply. Choose the MPX2053DP when your ADC or instrumentation amplifier needs more headroom and you are measuring pressures up to 50 kPa. Choose the MPX2050DP for higher-pressure ranges above 50 kPa where the lower sensitivity prevents saturation.
What instrumentation amplifier pairs best with the MPX2053DP?
A gain of approximately 100 is required to convert the MPX2053DP's 40 mV full-scale output to a 4 V signal for a 5 V ADC. The Texas Instruments INA126, INA128, or Analog Devices AD620 are excellent choices, offering low offset voltage (<50 µV), high CMRR (>100 dB), and single-supply operation from 5 V. For cost-sensitive designs, the INA128 with a gain-set resistor RG ≈ 1.2 kΩ provides a clean 4 V full-scale output.
Does the MPX2053DP require temperature compensation?
No external temperature compensation is required - the MPX2053DP is laser-trimmed at the wafer level to deliver a temperature-compensated span and offset across 0 °C to +85 °C. According to the NXP datasheet, the typical span temperature coefficient is ±0.5 % over the operating range. For systems that require higher accuracy across a wider temperature range, an external calibration look-up table in software is sufficient.
What supply voltage should I use with the MPX2053DP?
The MPX2053DP is specified at 10 V typical supply with a 16 V absolute maximum. Operating above 16 V risks permanent damage to the strain-gauge bridge. Because the output is ratiometric, the full-scale span scales linearly with supply - at 5 V supply the span is approximately 20 mV. Use a regulated 10 V supply or ratiometric ADC reference for best accuracy.
Can the MPX2053DP measure liquid pressure?
The MPX2053DP is qualified for non-corrosive gas or air media. The silicon die is exposed at the port opening and will corrode if contacted with water, oils, or aggressive chemicals. For liquid measurements, use a sealed gauge variant such as the MPX5700AP or apply an inert fluid isolator (thin oil column behind a flexible diaphragm) between the media and the sensor ports.
Is the MPX2053DP RoHS compliant?
Yes, the MPX2053DP is fully RoHS compliant and lead-free per NXP's product declaration. The 4-SIP module uses lead-free solder plating and complies with REACH substance restrictions. The part is not AEC-Q100 qualified; for automotive applications requiring pressure sensing, NXP recommends the MPXx5010 or MPX5700AS family which carry automotive-grade qualification.
What is the response time of the MPX2053DP?
The MPX2053DP has a response time of 1.0 ms typical, defined as the time required to reach 90% of the final output after a step pressure change. This makes it suitable for steady-state pressure monitoring and slow-dynamic medical applications such as respiratory flow measurement, where breath cycles are typically 3-5 seconds. For high-bandwidth acoustic or shock-wave measurements, consider a dedicated dynamic pressure transducer.
Where to buy the MPX2053DP online?
Authorized distributors carrying the MPX2053DP include DigiKey (digikey.com), Mouser (mouser.com), Heisener, and Xecor with same-day shipping for small quantities. Third-party sourcing is available on LCSC Electronics at significantly lower prices, but always verify lot traceability. Direct orders via NXP's website require a quote and are typically fulfilled in 8-12 weeks.
How does the MPX2053DP differ from the MPX2010DP?
The MPX2010DP is rated for 10 kPa (1.45 PSI) full scale with a 2.5 mV/kPa sensitivity, while the MPX2053DP covers 50 kPa (7.25 PSI) with a 0.8 mV/kPa sensitivity - both in the same 4-SIP Case 344-15 package. They are pin-compatible. Choose MPX2010DP for higher-resolution low-pressure applications (e.g., spirometry, very-low airflow), and MPX2053DP for mid-range differential pressure up to 50 kPa where higher headroom is needed.

Datos de referencia de ingeniería para MPX2053DP — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose the MPX2053DP when you need a calibrated differential pressure sensor in the 0-50 kPa range with on-chip temperature compensation and a ratiometric analog output. It is the optimal choice for medical respiratory monitors, HVAC filter diagnostics, and industrial low-pressure process control. For applications above 50 kPa, choose the MPX2100DP (100 kPa) or MPX2202DP (200 kPa), both sharing the same 4-SIP Case 344-15 footprint. For sub-10 kPa precision work like spirometry, choose the MPX2010DP which offers 2.5 mV/kPa sensitivity at the cost of a smaller operating range. All five NXP MPX20xxDP variants are pin-compatible drop-in replacements, enabling a single PCB layout to cover multiple pressure ranges by simple BOM substitution.

Comparación con alternativas

Parámetro Este producto MPX2050DP MPX2052DP MPX2010DP MPX2202DP MPX2100DP
Package 4-SIP Module (Case 344-15) 4-SIP Module (Case 344-15) - same 4-SIP Module (Case 344-15) - same 4-SIP Module (Case 344-15) - same 4-SIP Module (Case 344-15) - same 4-SIP Module (Case 344-15) - same
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Pressure Type Differential Differential Differential Differential Differential Differential
Operating Pressure Range 0-50 kPa (7.25 PSI) 0-50 kPa (7.25 PSI) - same 0-50 kPa (7.25 PSI) - same 0-10 kPa (1.45 PSI) - lower range 0-200 kPa (29 PSI) - higher range 0-100 kPa (14.5 PSI) - higher range
Sensitivity 0.8 mV/kPa 0.4 mV/kPa (-50%) 0.8 mV/kPa - same 2.5 mV/kPa (+212%) 0.2 mV/kPa (-75%) 0.4 mV/kPa (-50%)
Full-Scale Span (10 V) 40 mV 20 mV 40 mV 25 mV 40 mV 40 mV
Supply Voltage (max) 16 V 16 V - same 16 V - same 16 V - same 16 V - same 16 V - same
Operating Temperature 0 °C to +85 °C 0 °C to +85 °C - same 0 °C to +85 °C - same 0 °C to +85 °C - same 0 °C to +85 °C - same 0 °C to +85 °C - same
RoHS Compliant Yes Yes Yes Yes Yes Yes

Diferenciadores clave

  • Higher sensitivity (0.8 mV/kPa) than MPX2050DP (frente a MPX2050DP)
  • Higher pressure range than MPX2010DP (frente a MPX2010DP)
  • Established medical and HVAC pedigree (frente a MPX2202DP)

Notas de diseño

Estimated: The MPX2053DP differential output is 40 mV full-scale at 10 V supply, so a gain of ~100 is needed to drive a 5 V ADC. Use an instrumentation amplifier such as INA126 or AD620 with RG ≈ 1.2 kΩ for INA128 (gain = 1 + 49.4 kΩ/RG). Route the sensor outputs as a differential pair with equal-length traces and a ground guard trace to reject supply-coupled noise. Place a 100 nF ceramic bypass capacitor directly across pins 1 and 2 of the SIP module within 5 mm of the leads.

Do not expose the MPX2053DP die to liquids, oils, or corrosive gases - the silicon die is exposed at the port opening. For liquid pressure measurement, mount an inert fluid isolator (thin oil column behind a flexible diaphragm) between the media and the sensor. Also note that the device is not AEC-Q100 qualified - for automotive applications use the MPX5700AS or MPXx5010 family which carry automotive-grade certification.

The 4-SIP Case 344-15 package is through-hole and stands approximately 15 mm above the PCB. Reserve at least 20 mm of vertical clearance above the board for tubing connections. Provide strain-relief loops for the pneumatic tubing to avoid mechanical stress being transmitted to the sensor ports, and use flexible silicone or Tygon tubing rated for the application's pressure and chemical compatibility.

Self-heating of the bridge is negligible (<5 mW dissipation), so the device can be operated in still air without thermal concerns. However, for highest accuracy over the 0 °C to +85 °C range, mount the sensor away from heat sources such as power resistors, voltage regulators, and power inductors. The laser-trimmed temperature compensation is calibrated for the part's self-heating profile, so external heating may degrade accuracy.

Información de cumplimiento

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Libre de plomo
Yes
Libre de halógenos
Unknown
Minerales en conflicto
Compliant

RoHS and REACH compliant per NXP product declaration. Not AEC-Q100 qualified - automotive applications should use the MPX5700AS or MPXx5010 family instead. Halogen-free status not explicitly stated in available data; assumed not declared.

Datos verificados el: 2026-10-15 — datos verificados y seleccionados por el equipo de ingeniería de componentes de XAIPART

Búsquedas relacionadas

MPX2053DP MPX2053DP datasheet NXP MPX2053DP pressure sensor 50 kPa differential pressure sensor 4-SIP MPX2053DP medical respiratory monitor MPX2053DP vs MPX2050DP MPX2053DP drop-in replacement MPX2053DP buy online MPX2053DP price stock how does a piezoresistive pressure sensor work MPX2053DP pinout 4-SIP Case 344 MPX2053DP HVAC filter pressure best instrumentation amplifier for MPX2053DP

Componentes & términos relacionados

NXP Semiconductors MPX2053DP MPX2050DP MPX2052DP MPX2010DP MPX2202DP MPX2100DP pressure sensor differential pressure piezoresistive sensor MEMS sensor Wheatstone bridge 4-SIP module Case 344-15 ratiometric output RoHS REACH AEC-Q100 spanning calibration temperature compensation respiratory monitoring HVAC blood pressure monitor spirometry
RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
Total: $0.00 USD
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ