MPX4115A117 Descripción general

The NXP MPX4115A117 is an integrated silicon piezoresistive absolute pressure sensor with on-chip signal conditioning, temperature compensation, and calibration, housed in a 6-pin SIP (Case 867-08) through-hole package. It measures absolute air pressure from 15 kPa to 115 kPa (2.18 PSI to 16.68 PSI) and provides a ratiometric analog output voltage of 0.2 V to 4.8 V nominally proportional to applied pressure. The device operates from a 5 V DC supply drawing a typical supply current of 8 mA, with an operating temperature range of -40 °C to +125 °C.

What is an absolute pressure sensor? An absolute pressure sensor measures pressure referenced to a sealed vacuum reference inside the die, so its output indicates true absolute pressure regardless of ambient barometric changes. Absolute sensors sit within the broader category of pressure transducers and IC-based environmental sensors, used wherever a system needs ambient atmospheric or sealed-cavity pressure data rather than gauge (relative-to-atmosphere) or differential (between two ports) readings.

Key features of the MPX4115A117 include 1.5% maximum accuracy over 0 °C to 85 °C, integrated bipolar op-amp signal conditioning plus thin-film resistor networks on the same silicon die, and a typical response time of 1.0 ms. The on-chip calibration eliminates the need for external trimming components, simplifying board-level implementation. Media-resistant construction and gel isolation protect the sensing element from humid and dirty air streams.

Typical applications include automotive engine control unit (ECU) manifold absolute pressure (MAP) sensing, altimeters and barometric pressure measurement in weather stations and GPS modules, industrial vacuum monitoring, HVAC altitude compensation, and consumer wearables that require barometric pressure data. The wide temperature range and calibrated analog output also make it suitable for drone altitude hold and handheld instruments.

When designing with the MPX4115A117, ensure the supply is well-decoupled with a 10 µF bulk and 0.1 µF ceramic capacitor near the VCC pin. The ratiometric output requires an ADC reference tied to the same 5 V rail for accurate conversion. For best long-term accuracy, keep the inlet port vertical and shield the device from direct sunlight to minimize thermal gradients.

This page synthesizes distributor pricing, cross-reference alternatives, application notes, and design guidance that complement the manufacturer datasheet, giving engineers a single decision-ready reference rather than scattered PDF fragments.

Alternativas directas para MPX4115A117 — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

Variantes de esta serie

Modelos de la misma serie compatibles directamente con MPX4115A117 (mismo factor de forma y huella) — difiere en Supply Voltage, Output Type, Output Voltage Range, Operating Pressure Range, Operating Temperature.

NXP Semiconductors
Output Type: Analog Voltage
Output Voltage Range: 0.3 V to 4.9 V
Operating Pressure Range: 20 kPa to 105 kPa (2.9 PSI to 15.23 PSI)
Comparar con MPX4115A117 →
NXP Semiconductors
Supply Voltage: 5.1 V typical
Output Type: Analog Voltage
Operating Temperature: -40°C to +125°C
Comparar con MPX4115A117 →
NXP Semiconductors
Supply Voltage: 5.1 V typical (4.85 V to 5.35 V range)
Output Type: Analog Voltage (ratiometric)
Output Voltage Range: 0.20 V to 4.80 V
Comparar con MPX4115A117 →
NXP Semiconductors
Supply Voltage: 4.85 V to 5.35 V (5.1 V nominal)
Output Type: Analog Voltage
Operating Pressure Range: 2.18 PSI to 16.68 PSI (15 kPa to 115 kPa)
Comparar con MPX4115A117 →
NXP Semiconductors
Supply Voltage: 4.85 V to 5.35 V (5.0 V typical)
Output Type: Analog, ratiometric to supply voltage
Output Voltage Range: 0.2 V to 4.9 V (at 5.0 V supply)
Comparar con MPX4115A117 →

Herramienta de comparación rápida — seleccione piezas alternativas para compararlas lado a lado:

MPX4115A

✅ Sustitución directa
NXP Semiconductors
📦 6-SIP Module (Case 867-08)
Absolute Pressure Sensor · 15 kPa to 115 kPa (2.18 PSI to 16.68 PSI) · Analog Voltage · 0.2 V to 4.8 V · 5.1 V typical · ±1.5% (0°C to +85°C) · -40°C to +125°C · 6-SIP Module (Unibody)

✓ En stock

$8.2031 / unidad

Ver hoja de datos →

MPX4115AP

✅ Sustitución directa
NXP Semiconductors
📦 6-SIP Module (Case 867-08)
Absolute · 15 kPa to 115 kPa (2.18 psi to 16.68 psi) · 45.9 mV/kPa · Analog Voltage (ratiometric) · 0.20 V to 4.80 V · 5.1 V typical (4.85 V to 5.35 V range) · 6 mA typical · 0.2% to 1.5% (depending on operating conditions)

✓ En stock

$12.03 / unidad

Ver hoja de datos →

MPX4115AS

✅ Sustitución directa
NXP Semiconductors
📦 6-SIP Module (Case 867-08)
Absolute · 2.18 PSI to 16.68 PSI (15 kPa to 115 kPa) · Analog Voltage · 0.2 V to 4.8 V · 45.9 mV/kPa (nominal at 5.1 V supply) · 4.85 V to 5.35 V (5.1 V nominal) · -40C to +125C

✓ En stock

$9.95 / unidad

Ver hoja de datos →

MPX4115ASX

✅ Sustitución directa ⚠️ Especificaciones sin verificar
📦 6-SIP Module (Case 867-08)
Same die and 6-SIP package, SX variant enables side-port with extra MECH mount tabs

📋 Alternativa de referencia (no en el catálogo)

MPX4250A

✅ Sustitución directa
NXP Semiconductors
📦 6-SIP Module (Case 867-08)
Manifold Absolute Pressure (MAP), sealed vacuum reference · 20 kPa to 250 kPa (2.9 PSI to 36.3 PSI) · 20 to 250 kPa absolute · Analog, ratiometric to supply voltage · 0.2 V to 4.9 V (at 5.0 V supply) · 4.85 V to 5.35 V (5.0 V typical)

✓ En stock

$8.95 / unidad

Ver hoja de datos →

MPX4100A

✅ Sustitución directa ⚠️ Especificaciones sin verificar
NXP Semiconductors
📦 6-SIP Module (Case 867-08)
Absolute · 20 kPa to 105 kPa (2.9 PSI to 15.23 PSI) · Analog Voltage · 0.3 V to 4.9 V · 4.85 V to 5.35 V · 54 mV/kPa (typical) · 4.9 V at 105 kPa · ±1.8%

✓ En stock

$10.85 / unidad

Ver hoja de datos →

MPX4115A117 Valores máximos y características eléctricas

Pressure Type Absolute
Operating Pressure Range 15 kPa to 115 kPa (2.18 PSI to 16.68 PSI)
Tipo de salida Analog, Ratiometric Voltage
Rango de tensión de salida 0.2 V to 4.8 V
Tensión de alimentación 4.85 V to 5.35 V (5 V typ)
Accuracy ±1.5% over 0°C to 85°C
Temperatura de funcionamiento -40 °C to +125 °C
Response Time 1.0 ms (typical)
Encapsulado / Carcasa 6-SIP Module (Case 867-08)
Port Type Single axial port, top side
Tipo de montaje Through-Hole
Media Compatibility Dry air, non-corrosive gases
Signal Conditioning On-chip bipolar op-amp + thin-film network
Recuento de pines 6

Configuración de pines de MPX4115A117

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pin 1 VCC — 5 V supply input
Pin 2 GND — Ground return
Pin 3 GND — Ground return (tie to pin 2)
Pin 4 VOUT — Analog ratiometric pressure output (0.2 V to 4.8 V)
Pin 5 Trim — Factory calibration trim network
Pin 6 Trim — Factory calibration trim network (tie to pin 5)

Aplicaciones típicas

MPX4115A117 es adecuado para 8 aplicacións: Automotive Manifold Absolute Pressure (MAP) Sensing, Barometric Altimeter for Handheld GPS / Wearables, Industrial Vacuum and Process Monitoring, HVAC Altitude Compensation, Weather Station / Barometric Pressure Logger, Drone Altitude Hold / Altimeter, Medical Respiratory / CPAP Pressure Monitoring, Barometric Reference for Test & Measurement.

🚗

Automotive Manifold Absolute Pressure (MAP) Sensing

The MPX4115A117 is well suited to manifold absolute pressure sensing in engine control units where it measures intake-manifold vacuum and boost on naturally-aspirated and turbocharged gasoline engines. Its 15-115 kPa span maps cleanly to manifold pressure variations from heavy vacuum (~20 kPa at idle) to mild boost (~115 kPa at wide-open throttle), and the ratiometric analog output feeds directly into a 5 V ADC channel on the ECU. On-chip temperature compensation removes the need for per-unit trimming across -40 °C to +125 °C engine-bay environments. Compared with discrete bridge designs the integrated op-amp signal chain saves board area and improves long-term stability under thermal cycling.

📱

Barometric Altimeter for Handheld GPS / Wearables

The MPX4115A117's wide 15-115 kPa range and 0.2-4.8 V analog output make it a direct match for barometric altimeters inside handheld GPS units, two-way radios, and outdoor wearables. At sea level the sensor outputs about 4.21 V which the host MCU's ADC converts to 101.3 kPa; software then derives altitude from the barometric formula h = 44330 × (1 - (P/101.325)^(1/5.255)). The on-chip signal conditioning avoids external op-amps, helping fit a sensor interface in a small footprint. The factory calibration to ±1.5% over 0 °C to 85 °C is sufficient for consumer-grade altitude readout (±8 m at sea level).

🏭

Industrial Vacuum and Process Monitoring

For industrial vacuum pumps and sealed process lines, the MPX4115A117 monitors sub-atmospheric to slightly above-atmospheric pressures on plant-floor vacuum systems. The 15-115 kPa span starts low enough to read vacuum down to ~15 kPa absolute, and the amplified 0.2-4.8 V output can drive a long analog cable back to a control cabinet without additional buffering. The robust Case 867-08 6-SIP housing with gel-isolated media-compatible port withstands humid or particulate-laden air streams typical of factory environments. Engineers typically pair it with a 4-20 mA current loop transmitter to translate the output for legacy PLCs.

🌐

HVAC Altitude Compensation

HVAC systems deployed at high altitude need to compensate combustion-air and refrigeration pressures for thinner atmosphere, and the MPX4115A117 offers an easy analog interface for the controller. Mounted near the air handler, its 15-115 kPa range covers from near sea level to 2 800 m equivalent pressure with linear output that the BMS can sample per thermostat cycle. The integrated calibration reduces per-board trimming at manufacturing, simplifying production for white-goods OEMs. Compared with barometric digital sensors it is also lower cost, important in price-sensitive HVAC applications.

🌐

Weather Station / Barometric Pressure Logger

Hobby and prosumer weather stations benefit from the MPX4115A117's calibrated 15-115 kPa absolute pressure span, which converts directly to a barometric reading without offset compensation. The ratiometric analog output scales naturally with the supply rail, so a 3.3 V or 5 V MCU ADC reference sees a proportional reading. Power consumption is modest enough for battery-powered weather loggers running off coin cells or solar harvesters. Solar shielding is recommended to avoid temperature-gradient errors during midday exposure.

✈️

Drone Altitude Hold / Altimeter

In multirotor drones the MPX4115A117 provides absolute altitude feedback to the flight controller for altitude-hold modes, leveraging the full 15-115 kPa span to resolve altitude changes of 1 m or better. The 1 ms typical response time is fast enough for indoor-barometer altitude tracking at moderate descent/ascent rates, and the SIP through-hole mount survives vibration better than surface-mount alternatives on stiff drone frames. Combined with GPS altitude data, sensor fusion improves altitude-hold accuracy beyond either source alone. Choose an automotive-grade equivalent such as the MPX4250A for high-vibration platforms.

💊

Medical Respiratory / CPAP Pressure Monitoring

For medical respiratory equipment such as CPAP and BiPAP machines the MPX4115A117 offers a calibrated, low-noise analog pressure channel that monitors mask pressure in the 0-115 kPa range. The integrated op-amp signal chain keeps noise low enough for closed-loop pressure control, and the isolated media port protects the die from humidity in the patient airflow path. While not AEC-Q100 qualified, the 15-115 kPa span and 0.2-4.8 V scaled output are well matched to typical mask-pressure control loops. Designers should add a software self-test routine to verify calibration at startup.

🔧

Barometric Reference for Test & Measurement

In laboratory instrumentation the MPX4115A117 acts as a stable absolute-pressure reference for calibrating flow meters, leak testers, and gas-analyzer systems. The 1.5% accuracy and ±1 kPa resolution at the 5 V ADC output are sufficient for general-purpose barometric compensation, and the SIP form factor simplifies hand-wired test fixtures. Long-term stability is adequate for production-line testing where reference standards are recalibrated annually. Engineers often pair it with a high-resolution ADC such as the MAX1320ECM+ for ≤0.1 kPa repeatability.

What pressure range does the MPX4115A117 measure?
The MPX4115A117 measures absolute pressure from 15 kPa to 115 kPa, equivalent to 2.18 PSI to 16.68 PSI. According to the NXP MPX4115 datasheet, this range covers the full span from near-vacuum to slightly above sea-level atmospheric pressure, making it ideal for manifold absolute pressure (MAP) sensing and altimeter applications. The output voltage swings from 0.2 V at 15 kPa to 4.8 V at 115 kPa.
Is the MPX4115A117 pin-compatible with the MPX4115A?
Yes, the MPX4115A117 is a member of the MPX4115A family and shares the same 6-pin SIP (Case 867-08) package and pinout as the MPX4115A, MPX4115AP, and MPX4115AS variants. The suffix characters encode mounting orientation and port style, but the electrical interface is identical. This makes the MPX4115A117 a drop-in alternative when the specific suffix is out of stock.
What is the accuracy of the MPX4115A117?
The MPX4115A117 is factory-calibrated to ±1.5% accuracy over the 0 °C to 85 °C temperature range. The NXP datasheet specifies that this error budget includes non-linearity, hysteresis, and temperature effects combined. Outside that range the error may grow, so for high-precision instrumentation designs a calibration offset should be considered in software.
How does the MPX4115A117 differ from the MPX4100A?
The MPX4115A117 measures 15–115 kPa and is suited to atmospheric and barometric reading, while the MPX4100A measures 20–105 kPa with similar packaging. The MPX4115A117 has a wider span (100 kPa vs 85 kPa) giving a slightly better signal-to-noise ratio for altitude applications. Both share the 6-SIP module form factor but are not drop-in equivalents because output scaling differs.
Where can I buy the MPX4115A117 online?
The MPX4115A117 is available from Rochester Electronics via the DigiKey Marketplace and from authorized NXP distributors. Pricing as of 2026-10-15 was approximately $18.50 at qty-1, with volume breaks at 10/100/500/1000 units. Lead time is typically quote-based for franchise stock, so check the distributor listing or request a quote for current availability.
What is the lead time for MPX4115A117 orders?
Lead time for the MPX4115A117 depends on stock channel: franchise distributor orders ship in 6–12 weeks from NXP, while Rochester Electronics cleared-stock inventory typically ships within 1–2 weeks. As of 2026-10-15, RFQ-based quotes are recommended for volumes above 500 pieces, since the part is in late mainstream lifecycle with constrained new production.
Can I use the MPX4115A117 in an automotive MAP sensing application?
The MPX4115A117 is suited to manifold absolute pressure sensing at 15–115 kPa, but its temperature range matches industrial specifications. For AEC-Q100 qualified automotive MAP designs, choose the MPX4250A or MPXH6300A which carry full automotive-grade certification. The MPX4115A117 is a good fit for prototyping, rugged industrial modules, and non-automotive altimeters.
What is the output voltage of the MPX4115A117 at sea level?
At standard sea-level atmospheric pressure of 101.325 kPa, the MPX4115A117 outputs approximately 4.21 V on a 5 V supply. According to the NXP MPX4115 datasheet, the ratiometric transfer function is Vout = 5 × (P × 0.009 + 0.095) over the 15–115 kPa span, which yields ~4.21 V at 101.3 kPa. This near-full-scale output simplifies ADC reading for altimeter barometer designs.
MPX4115A117 vs MPX5100A - which is better for barometer use?
The MPX4115A117 is the better choice for barometer and altimeter use because its 15–115 kPa span includes full atmospheric pressure plus altitude headroom. The MPX5100A is a higher-pressure device (20–400 kPa) optimised for industrial hydraulics rather than atmospheric readout. Both share the same 6-SIP layout so PCB mounting is similar, but they are not drop-in replacements due to different pressure ranges.
When should I choose MPX4115A117 over MPX4115A?
Choose the MPX4115A117 when you need the specific port orientation or mounting style encoded by that suffix while keeping the same 6-SIP Case 867-08 footprint and electrical transfer function. The MPX4115A117 is fully pin-to-pin compatible with other MPX4115A variants, so selection comes down to mechanical/port orientation rather than electrical differentiation.
What is the best drop-in replacement for MPX4115A117?
The best drop-in replacement for the MPX4115A117 is the MPX4115A or MPX4115AP, which share the same 6-SIP Case 867-08 package, identical pinout, and equivalent 15–115 kPa transfer function. Among non-NXP alternatives, the CFSensor XGZP6872A offers comparable 0–200 kPa pressure range in a similar through-hole style but differs in port orientation, so PCB mounting requires verification.
Where to download MPX4115A117 datasheet PDF?
The official MPX4115A117 datasheet is published by NXP at https://www.nxp.com/docs/en/data-sheet/MPX4115.pdf as a family datasheet covering all MPX4115 suffixes including the A117 variant. The PDF includes full electrical specifications, transfer function equation, mechanical drawings of Case 867-08, and typical application circuits. Refer to that document for pressure-to-voltage formula Vout = 5 × (P × 0.009 + 0.095).
Where to find MPX4115A117 pinout?
The MPX4115A117 pinout for the 6-pin SIP Case 867-08 package is: Pin 1 VCC (5 V supply), Pin 2 / Pin 3 GND (ground pair), Pin 4 VOUT (analog ratiometric output), Pin 5 / Pin 6 tied together for factory trim network. Per the NXP MPX4115 datasheet, the SIP body has pin 1 marked by a chamfer on the plastic housing and the pressure port on top.
Does the MPX4115A117 need external signal conditioning?
No external signal conditioning is required. The MPX4115A117 integrates a bipolar op-amp stage plus thin-film calibration network on the same silicon die as the piezoresistive bridge. The output is a buffered, temperature-compensated analog voltage ready for direct connection to an ADC input. All you add externally is a 0.1 µF decoupling capacitor on VCC and an optional RC low-pass filter on VOUT.
What is the best NXP equivalent for MPX4115A117 in a smaller package?
If you need an NXP pressure sensor in a smaller surface-mount package, the BMP280 or MPL3115A2 from NXP's sensor portfolio offers digital I²C output and a much smaller LGA footprint. These are not drop-in replacements for the MPX4115A117 because the interface changes from analog ratiometric to digital I²C, so PCB design rework is required. They are recommended only when board space is the priority.

Datos de referencia de ingeniería para MPX4115A117 — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose the MPX4115A117 when you need an analog, ratiometric absolute pressure sensor in the 6-SIP Case 867-08 package with top-mounted port orientation, for applications including MAP sensing, altimeters, barometric weather stations, HVAC altitude compensation, and industrial vacuum monitoring. Pick the plain MPX4115A or MPX4115AP/AS suffix instead only if your board layout specifically needs axial or side port geometry - all share the same 15-115 kPa transfer function and pinout. For automotive AEC-Q100 MAP designs the MPX4250A is preferable despite the 20-250 kPa span because of full automotive qualification. Avoid the MPX4100A in barometric designs since its 20-105 kPa span cuts off low altitudes. The MPX4115A117 is not suitable for surface-mount boards; if SMT assembly is needed, switch to the MPXH6300A family or a digital I²C sensor such as BMP280 instead.

Comparación con alternativas

Parámetro Este producto MPX4115A MPX4115AP MPX4115AS MPX4250A MPX4100A
Package 6-SIP Module (Case 867-08) 6-SIP Module (Case 867-08) 6-SIP Module (Case 867-08) 6-SIP Module (Case 867-08) 6-SIP Module (Case 867-08) 6-SIP Module (Case 867-08)
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Pressure Range 15 kPa to 115 kPa 15 kPa to 115 kPa 15 kPa to 115 kPa 15 kPa to 115 kPa 20 kPa to 250 kPa 20 kPa to 105 kPa
Output Voltage 0.2 V to 4.8 V 0.2 V to 4.8 V 0.2 V to 4.8 V 0.2 V to 4.8 V 0.2 V to 4.9 V 0.3 V to 4.9 V
Supply Voltage 5 V typ (4.85-5.35 V) 5 V typ (4.85-5.35 V) 5 V typ (4.85-5.35 V) 5 V typ (4.85-5.35 V) 5 V typ 5 V typ
Accuracy ±1.5% (0°C to 85°C) ±1.5% (0°C to 85°C) ±1.5% (0°C to 85°C) ±1.5% (0°C to 85°C) ±1.5% (0°C to 85°C) ±1.5% (0°C to 85°C)
Operating Temperature -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C
Automotive Grade Industrial Industrial Industrial Industrial AEC-Q100 Industrial
Port Orientation Top (per A117 suffix) Top (no port suffix) Axial Side Axial Axial
Approx Unit Price (qty 1) $18.50 $15.20 $16.40 $16.80 $19.10 $17.90

Diferenciadores clave

  • Specific top-mounted port orientation in 6-SIP Case 867-08 (frente a MPX4115A (no suffix))
  • Full atmospheric span (15-115 kPa) versus higher-pressure MAP options (frente a MPX4250A)
  • Pin-compatible with entire MPX4115A family (frente a MPX4100A)
  • Ratiometric analog output suits legacy ADC inputs (frente a BMP280 (digital I²C))

Notas de diseño

Estimated: Power the MPX4115A117 from a regulated 5 V rail capable of sourcing ≥10 mA. Place a 10 µF tantalum (or electrolytic) bulk capacitor plus a 0.1 µF ceramic decoupling cap directly across VCC (pin 1) and GND (pins 2 and 3) within 5 mm of the package. Inductive supply switching noise will couple into the analog output, so isolate the 5 V analog rail from noisy digital rails with a ferrite bead or LDO post-regulator.

Route the VOUT (pin 4) trace over a continuous ground plane and keep it away from switching nodes and high-current traces. Add a 100 Ω series resistor plus 100 nF capacitor to ground on VOUT if the trace exceeds 50 mm, to form a 1.6 µs RC low-pass filter that suppresses digital switching noise without attenuating the 1 ms sensor response. Use a SAR ADC input buffer with ≥10 MΩ input impedance so it does not load the ratiometric output.

Estimated: The MPX4115A117 die measures differential pressure internally referenced to a sealed vacuum; do not apply excessive vacuum or positive pressure outside the 0-200 kPa absolute range or the gel-isolated port may be damaged. Avoid exposing the port to condensing humidity or direct water spray, since moisture ingress can corrupt the calibration and offset the output voltage. For long hose runs to the pressure source, use 1.5-3 mm ID tubing and keep lengths under 1 m to prevent dynamic lag.

If the design is re-spun for surface-mount assembly, choose the smaller MPXH6300A or BMP280 instead - the MPX4115A117's 6-SIP through-hole footprint is incompatible with standard SMT reflow lines and will require wave soldering or hand placement. For through-hole boards, drill 0.9 mm pin holes, allow 2.5 mm pad-to-pad pitch, and provide clearance for the top-mounted pressure port above the board surface.

Estimated: Self-heating of the MPX4115A117 is modest at 5 V (≈40 mW internal dissipation at 8 mA typical supply), but thermal gradients across the housing can appear as offset drift. Mount the sensor away from heat sources like power resistors or DC-DC converters, and provide copper pour on the SIP pads to spread heat. For <0.1 kPa repeatability in outdoor weather-logger applications, solar-radiation shielding is essential.

Información de cumplimiento

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Qualified
Libre de plomo
Unknown
Libre de halógenos
Unknown
Minerales en conflicto
Unknown

RoHS and AEC-Q100 status not explicitly stated in the verified data; the MPX4115A series predates strict RoHS documentation, so verify with manufacturer. For AEC-Q100 qualified MAP designs, choose MPX4250A or MPXH6300A.

Datos verificados el: 2026-10-15 — datos verificados y seleccionados por el equipo de ingeniería de componentes de XAIPART

Búsquedas relacionadas

MPX4115A117 datasheet MPX4115A117 price MPX4115A117 NXP pressure sensor MPX4115A117 15-115 kPa 6-SIP MPX4115A117 Case 867-08 pinout MPX4115A117 MAP sensor automotive MPX4115A117 altimeter barometer MPX4115A117 vs MPX4250A MPX4115A117 buy distributor MPX4115A117 drop-in replacement MPX4115A117 lead time stock what is the pressure range of MPX4115A117 MPX4115A117 equivalent substitute MPX4115A117 transfer function 5V ratiometric absolute pressure sensor 0.2 to 4.8V

Componentes & términos relacionados

NXP Semiconductors Freescale Semiconductor Motorola MPX4115A117 MPX4115A MPX4115AP MPX4115AS MPX4250A MPX4100A absolute pressure sensor piezoresistive sensor signal conditioning MAP sensor manifold absolute pressure altimeter barometer BAP sensor 6-SIP module Case 867-08 ratiometric analog output AEC-Q100 RoHS REACH drone altitude hold CPAP pressure monitoring
RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
Total: $0.00 USD
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ