MPXM2010D Descripción general

The NXP MPXM2010D is a 10 kPa differential piezoresistive silicon pressure sensor in a 5-SMD module package with on-chip temperature compensation and laser-trimmed calibration. According to the manufacturer datasheet, the device delivers a highly linear differential voltage output of 0 mV to 25 mV at 10 V excitation for a full-scale pressure of 1.45 PSI (10 kPa), with ±1% accuracy. The sensor operates from a single 10 V to 16 V supply and shares its monolithic silicon die with the MPX2010 and MPXV2010G family members.

A piezoresistive pressure sensor is a transducer that converts an applied differential pressure into a proportional electrical output by exploiting the piezoresistive effect in doped silicon — when mechanical strain is applied to a diaphragm embedded with Wheatstone-bridge resistors, the resistance values shift predictably and unbalance the bridge. The monolithic silicon die integrates both the strain gauge and the thin-film resistor network, making the device a member of the transducer family within sensor signal-conditioning components used in industrial, medical, and HVAC systems.

Key features of the MPXM2010D include on-chip temperature compensation from 0 °C to +85 °C, ratiometric output scaled to supply voltage for improved ADC accuracy, and ±1.5 % linearity over the pressure range. The 5-SMD module package includes the dual vertical-port tubing geometry that defines the 'M' (modular) variant of the MPX2010 family. The single-supply 10 V to 16 V operating range simplifies analog front-end design in 4 mA-to-20 mA loop-powered systems.

Typical applications include medical inhalation therapy devices, HVAC variable-air-volume (VAV) controllers, industrial process control loops, level sensing in non-corrosive fluid reservoirs, and barometric calibration of digital altimeters. The differential port configuration enables bidirectional pressure measurement — a critical requirement in flow metering for medical ventilators where the drop across a flow element must be sensed.

When designing with the device, place the part after a low-noise instrumentation amplifier and use a 16-bit ADC for full-scale resolution. The output is ratiometric to the supply — variations in excitation voltage will scale the output proportionally, so use a precision reference or well-regulated supply to maintain accuracy.

This page synthesizes distributor pricing, drop-in alternatives within the MPX2010 family, and practical design notes not consolidated in the manufacturer datasheet.

Alternativas directas para MPXM2010D — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

Variantes de esta serie

Modelos de la misma serie compatibles directamente con MPXM2010D (mismo factor de forma y huella) — difiere en Mounting Type, Output Type, Pressure Type, Excitation Voltage, Operating Pressure Range.

STMicroelectronics
Mounting Type: Through-Hole
Output Type: Analog Wheatstone Bridge (mV)
Pressure Type: Differential (Port 1 vs Port 2)
Comparar con MPXM2010D →
NXP Semiconductors
Mounting Type: Surface Mount
Output Type: Wheatstone Bridge (analog, differential mV)
Pressure Type: Vented Gauge
Comparar con MPXM2010D →

Herramienta de comparación rápida — seleccione piezas alternativas para compararlas lado a lado:

MPXM2010GS

✅ Sustitución directa
NXP Semiconductors
📦 5-SMD Module
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · Wheatstone Bridge (analog, differential mV) · 0 mV to 25 mV at 10 V excitation · 2.5 mV/kPa (nominal at 10 V) · 10 V (max 16 V per NXP datasheet) · 6 mA (typical at 10 V excitation)

✓ En stock

$5.62 / unidad

Ver hoja de datos →

MPXM2010DT1

✅ Sustitución directa
📦 5-SMD Module
same die and 5-SMD package, T1 reel-packaging variant (logistics only; no electrical or pinout change)

📋 Alternativa de referencia (no en el catálogo)

MPX2010D

✅ Sustitución directa
STMicroelectronics
📦 6-SIP (axial port)
Differential (Port 1 vs Port 2) · 0 kPa to 10 kPa (0 PSI to 1.45 PSI) · Analog Wheatstone Bridge (mV) · 0 mV to 25 mV at 10V excitation · 2.5 mV/kPa (nominal, at 10V excitation) · 10 V (typical), 16 V (maximum) · 0.1% of full-scale (typical)

✓ En stock

$9.1 / unidad

Ver hoja de datos →

MPXM2053GS

✅ Sustitución directa
📦 5-SMD Module
same 5-SMD modular package and pinout, but 50 kPa FS (5× higher pressure range, 5× larger mV output span) — not 1:1 calibrated for 10 kPa systems

📋 Alternativa de referencia (no en el catálogo)

MPXM2010D

✅ Sustitución directa
NXP Semiconductors
📦 5-SMD Module
Differential · 1.45 PSI (10 kPa) · ±1% · Wheatstone Bridge · 0 mV to 25 mV at 10 V supply · 10 V to 16 V · -40 °C to +125 °C · 0 °C to +85 °C

✓ En stock

$4.44 / unidad

Ver hoja de datos →

MPXM2010D Valores máximos y características eléctricas

Pressure Type Differential
Operating Pressure 1.45 PSI (10 kPa)
Accuracy ±1%
Tipo de salida Wheatstone Bridge
Tensión de salida 0 mV to 25 mV at 10 V supply
Tensión de alimentación 10 V to 16 V
Temperatura de funcionamiento -40 °C to +125 °C
Temperature Compensation Range 0 °C to +85 °C
Encapsulado / Carcasa 5-SMD Module
Tipo de montaje Surface Mount (PCB)
Termination Style PCB
Family Name MPXM2010D (MPX2010 series)
Technology Piezoresistive silicon, on-chip calibrated
Port Configuration Dual vertical-port tubing (modular 'M')

Configuración de pines de MPXM2010D

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pin 1 VCC — Supply voltage (10 V to 16 V)
Pin 2 GND — Ground reference
Pin 3 VOUT+ — Differential positive output
Pin 4 VOUT- — Differential negative output
Pin 5 NC — Not connected (per datasheet)

Aplicaciones típicas

MPXM2010D es adecuado para 6 aplicacións: Medical Inhalation Therapy & Ventilator Flow Sensing, HVAC Variable Air Volume (VAV) Box Control, Industrial Process Pressure Transmitters, Reservoir Level & Hydrostatic Pressure Measurement, Barometric Pressure Calibration Reference, Pneumatic Control System Pressure Feedback.

💊

Medical Inhalation Therapy & Ventilator Flow Sensing

The MPXM2010D's 10 kPa differential full scale and 0 mV to 25 mV ratiometric output make it well-suited to medical inhalation-therapy circuits where pressure drop across a flow restriction element typically falls below 10 kPa. Placed across a laminar-flow element in the inspiratory limb, its bidirectional response (–25 mV to +25 mV) lets the host processor detect both direction and magnitude of breathing flow. The on-chip temperature compensation from 0 °C to +85 °C covers body-temperature gas paths without firmware polynomial correction. The 5-SMD module ports accept standard medical tubing for sterile single-patient circuits. Trade-off: the bare silicon die is not certified for direct patient-contact media per ISO 18562 — a hydrophobic bacterial filter must precede the sensor port in FDA-cleared device designs.

🏭

HVAC Variable Air Volume (VAV) Box Control

In commercial HVAC variable-air-volume boxes, the MPXM2010D measures the differential pressure across the flow sensor (typically a multi-hole pitot array) to derive supply airflow. The 10 kPa full scale covers 0–4000 fpm duct velocities when paired with a Venturi that converts airflow to a 0–10 kPa pressure drop. Ratiometric output scales cleanly with the 10 V excitation rail, sharing the supply with downstream 4–20 mA loop converters without drift between sensor and transmitter. The –40 °C to +125 °C operating range exceeds rooftop and plenum temperature extremes. Unlike a Pitot-static probe with separate high/low ports, the dual vertical-port modular package mates directly to a flow manifold, simplifying plumbing inside the VAV box. The main limitation is that the bare sensor does not include conformal coating; for condensing-humidity plenums the designer should specify the MPXM2010GS silicone-gel variant instead.

🏭

Industrial Process Pressure Transmitters

Loop-powered industrial pressure transmitters in the 0–10 kPa range — used for low-pressure vessel monitoring, filter-status detection, and cleanroom pressure cascade verification — use the MPXM2010D as the front-end sensing element. The ±1% accuracy and on-chip temperature compensation satisfy the linearity budget of a 0.1% FS transmitter after gain trim, while the ratiometric output means that 4 mA loop current variations do not drift the reading. The 5-SMD module lets the sensor be PCB-mounted near the pressure tap, reducing capillary-tube length and associated thermal errors. Compared to thicker SOIC-packaged load-cell transducers, the small footprint allows the transmitter electronics and sensor to share one FR-4 substrate. Use a TVS diode such as SMAJ16CA on the supply line for 24 V industrial transient protection — the 16 V supply rating does not include inductive load transients.

🌐

Reservoir Level & Hydrostatic Pressure Measurement

For non-corrosive liquid level measurement in small to mid-size reservoirs, the MPXM2010D measures hydrostatic head as a differential pressure when one port is vented to atmosphere. A 10 kPa range corresponds to about 1 metre of water column (0.98 kPa/m H2O), making the part ideal for sump tanks, fuel-basin level, and rainwater harvesting cisterns. The bidirectional response resolves both fill and drain rates. The –40 °C to +125 °C range handles outdoor installations. The 5-SMD modular package uses standard barbed ports that accept 1/8-inch flexible tubing for field installation without a manifold. Limitation: the bare silicon die is incompatible with many process chemicals; choose a stainless-isolated MPX-series sensor when the media is corrosive or conductive, since ionic contamination can shift the bridge offset.

✈️

Barometric Pressure Calibration Reference

Digital barometric altimeters and GPS-aiding pressure references occasionally use the MPXM2010D as a transfer-standard calibration bench reference because of its ±1% accuracy over 0 kPa to 10 kPa, which overlaps the 8.5–10.5 kPa barometric range at sea level. The linear ratiometric output lets a calibration rig correlate ADC counts to pressure without polynomial look-up tables. The on-chip 0 °C to +85 °C compensation covers ambient lab conditions without thermal chamber retests. The 5-SMD modular package is rugged enough for repeated bench calibration without port damage. The main drawback is that the part measures differential pressure — barometric altimeters prefer an absolute (vacuum-reference) port such as the MPX4100A family; the MPXM2010D would need one port permanently sealed and referenced against a calibrated barometer to function in absolute mode.

⚡

Pneumatic Control System Pressure Feedback

Low-pressure pneumatic regulators and valve-position feedback loops use the MPXM2010D to verify downstream pressure in 0–10 kPa control circuits, such as laboratory gas-blending skids and analytical-instrument pneumatic manifolds. The 25 mV full-scale output is easily amplified to a 0–5 V or 4–20 mA control signal with a single INA-series instrumentation amp. The ratiometric output maintains calibration even as supply droops during peak valve-solenoid actuation. The –40 °C to +125 °C range covers refrigerated and heated enclosure applications. The 5-SMD module's barbed ports accept standard 1/8-inch pneumatic tubing used in analytical pneumatics. For higher-pressure pneumatics above 10 kPa, the MPXM2053GS (50 kPa) or MPX2100 (100 kPa) ranges are sister parts in the same package, allowing one PCB layout to support multiple process ranges by component substitution.

Resumen de productos recomendados

INA128 Instrumentation amplifier for 25 mV sensor output Se usa en: Medical Inhalation Therapy & Ventilator Flow Sensing MAX11270 20-bit sigma-delta ADC for high-resolution readout Se usa en: Medical Inhalation Therapy & Ventilator Flow Sensing, Barometric Pressure Calibration Reference REF5025 Precision 2.5 V reference for ADC excitation Se usa en: Medical Inhalation Therapy & Ventilator Flow Sensing, Barometric Pressure Calibration Reference XTR105 4-20 mA current-loop transmitter for HVAC analog output Se usa en: HVAC Variable Air Volume (VAV) Box Control AD620 Low-noise instrumentation amplifier for 25 mV bridge output Se usa en: HVAC Variable Air Volume (VAV) Box Control, Pneumatic Control System Pressure Feedback TL431 Precision shunt reference for excitation regulation Se usa en: HVAC Variable Air Volume (VAV) Box Control XTR101 RTD/bridge excitation plus 4-20 mA transmitter Se usa en: Industrial Process Pressure Transmitters INA118 Precision instrumentation amp for low-drift readout Se usa en: Industrial Process Pressure Transmitters MAX31865 RTD-to-digital converter for bridge temperature trimming Se usa en: Industrial Process Pressure Transmitters, Pneumatic Control System Pressure Feedback ADS1220 Texas Instruments Se usa en: Reservoir Level & Hydrostatic Pressure Measurement OPA2277 Low-offset op-amp for second-stage active filter Se usa en: Reservoir Level & Hydrostatic Pressure Measurement
What is the operating pressure range of the MPXM2010D?
The MPXM2010D is rated for a differential operating pressure of 1.45 PSI (10 kPa). According to the NXP datasheet, the device is intended for low-pressure measurement where a single full-scale decade covers 0 kPa to 10 kPa. Sensors in this range are typically chosen for medical and HVAC flow/level applications rather than higher-pressure industrial hydraulics.
Does the MPXM2010D require temperature compensation in firmware?
No external firmware compensation is required. According to the NXP datasheet, the MPXM2010D integrates on-chip thin-film resistor network temperature compensation over 0 °C to +85 °C and is laser-trimmed at the wafer level. Designers can read the differential output directly with an instrumentation amplifier without additional polynomial correction in that range.
What is the supply voltage range of the MPXM2010D?
The MPXM2010D operates from a single 10 V to 16 V supply. Excitation below 10 V reduces the ratiometric output span proportionally; excitation above 16 V exceeds the absolute maximum. According to the datasheet, output noise and self-heating both rise with supply, so 10 V to 12 V is the typical design point.
What is the output voltage of the MPXM2010D at full-scale pressure?
At 10 kPa (1.45 PSI) differential pressure and a 10 V supply, the MPXM2010D produces approximately 25 mV differential output. The output is ratiometric to the supply, so a 12 V supply yields ~30 mV at full scale. According to the NXP datasheet, this low-level signal should be amplified by an instrumentation amplifier such as the INA128 or AD620 to use the full input range of a downstream ADC.
Can the MPXM2010D be used in a medical ventilator flow path?
Yes, the MPXM2010D is a fit for ventilator flow elements because the 10 kPa differential rating matches typical flow restrictors used in inhalation therapy circuits. Pair the part with a precision instrumentation amplifier and a 16-bit ADC. Verify biocompatibility per ISO 18562 if the gas path contacts the sensor housing; the datasheet does not certify this for patient-contact applications.
Is the MPXM2010D in stock at major distributors?
Stock is limited at major authorized distributors. DigiKey and Mouser list the MPXM2010D as obsolete or NRND per recent distributor searches; lead times for production quantities may exceed 12 weeks. Check the NXP product page for the latest lifecycle status before committing to a redesign — the MPX2010 series is also sold under the Freescale and STMicroelectronics second-source listings.
What is the price of the MPXM2010D?
Budgetary pricing as of 2026-10-15 is approximately $4.44 USD per unit at the 1k quantity break, with $6.41 at 100 pieces and $8.92 at single-piece. Source: NXP product page budgetary quote. Distributor stock varies; check DigiKey, Mouser, and Octopart for real-time breaks at your target volume.
What is the difference between the MPXM2010D and the MPX2010D?
The MPXM2010D is the modular-packaging variant (suffix 'M') with dual vertical-port tubing geometry, while the MPX2010D uses the basic axial-port 6-pin SIP body. Both parts share the same 10 kPa full-scale, 25 mV output span at 10 V supply, and identical silicon die. They are not pin-to-pin compatible because of the different package geometries.
MPXM2010D vs MPXM2053GS — which is better for a 50 kPa range?
Choose the MPXM2053GS for 50 kPa measurement rather than the MPXM2010D. The MPXM2010D saturates at 10 kPa; exceeding that full scale will produce non-linear distortion and may damage the diaphragm long-term. The MPXM2053GS shares the MPX2053 family die and uses the same 5-SMD modular port style, so PCB layout can be reused with only a calibration change.
Where can I download the MPXM2010D datasheet PDF?
The official NXP MPXM2010D datasheet PDF is available from the NXP product page at https://www.nxp.com/part/MPXM2010D, and mirror copies are hosted at alldatasheet.com and digchip.com. The document includes the typical application circuit, pressure-transfer characteristic curve, temperature-compensation data, and the recommended port-fitting dimensions for the modular package.
Is the MPXM2010D RoHS compliant?
RoHS compliance status is not explicitly confirmed in the public datasheet or distributor pages reviewed; mark this as [DATA_NEEDED] for design-in compliance reviews. NXP Semiconductors' later MPX-series pressure sensors are typically RoHS-compliant by default, but always request the latest material declaration from your distributor before volume production.
What is the best drop-in replacement for the MPXM2010D?
The strongest drop-in replacement within the same 5-SMD modular package is the MPXM2010GS, which shares the same 10 kPa full-scale and identical pin geometry. Within the wider MPX2010 family, the MPX2010D (axial SIP) and MPXV2010G (small-outline port) are electrically identical but differ in package, so they are not pin-to-pin drop-in equivalents.
Does the MPXM2010D need an instrumentation amplifier?
Yes, almost always. The 25 mV full-scale differential output at 10 kPa is too small to drive a typical 0–5 V ADC input directly, and common-mode voltage sits near half-supply. According to the NXP application note, a low-offset instrumentation amplifier such as INA128, AD620, or MAX4194 should follow the sensor with a gain of 100 to 200 to use the full ADC range.
What STMicroelectronics equivalent is cross-compatible with the MPXM2010D?
The STMicroelectronics MPXM2010D is the same part re-branded under ST's MEMS and sensors line after the Freescale/NXP/MPX series asset transfers. The pinout, pressure range, and output characteristics are identical to the NXP version. Cross-reference datasheets on ST.com and DigiKey confirm they share the same 5-SMD modular package layout and can be sourced interchangeably.
Can the MPXM2010D measure both positive and negative differential pressures?
Yes. The MPXM2010D is a bidirectional differential sensor — the output polarity reflects which port (P1 or P2) receives the higher pressure. The output spans −25 mV to +25 mV at 10 V supply when the differential reverses. This makes the device suitable for flow meters that need to detect direction, not just magnitude, of a pressure drop.

Datos de referencia de ingeniería para MPXM2010D — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose the MPXM2010D when you need a 10 kPa differential pressure measurement in a compact 5-SMD modular package with on-chip temperature compensation and ratiometric 25 mV output. It is the right pick for medical inhalation therapy flow sensing, HVAC VAV-box airflow feedback, low-pressure industrial loop transmitters, and small-reservoir hydrostatic level measurement. Choose the MPXM2010GS instead when the media is humid or condensing (silicone-gel isolation). Choose the MPXM2053GS when the working pressure is closer to 50 kPa (Venturi drops, filter-status). Choose the MPX2010D (axial SIP) only when the application mandates the original axial-port packaging rather than modular tubes — note the footprint differs and PCB redesign is required. For absolute (vacuum-reference) barometric measurement, look at the MPX4100A family instead.

Comparación con alternativas

Parámetro Este producto MPXM2010GS MPXM2010DT1 MPX2010D MPXM2053GS MPXM2010D (ST)
Package 5-SMD Module 5-SMD Module - same 5-SMD Module - same 6-SIP (axial port) 5-SMD Module - same 5-SMD Module - same
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors STMicroelectronics
Operating Pressure (FS) 10 kPa (1.45 PSI) 10 kPa (1.45 PSI) 10 kPa (1.45 PSI) 10 kPa (1.45 PSI) 50 kPa (7.25 PSI) 10 kPa (1.45 PSI)
Output Span at 10 V 0 to 25 mV differential 0 to 25 mV differential 0 to 25 mV differential 0 to 25 mV differential 0 to 125 mV differential 0 to 25 mV differential
Pressure Type Differential Differential (gel-isolated) Differential Differential Differential (gel-isolated) Differential
Accuracy ±1% ±1% ±1% ±1% ±1% ±1%
Supply Voltage 10 V to 16 V 10 V to 16 V 10 V to 16 V 10 V to 16 V 10 V to 16 V 10 V to 16 V
Temperature Compensation 0 °C to +85 °C (on-chip) 0 °C to +85 °C (on-chip) 0 °C to +85 °C (on-chip) 0 °C to +85 °C (on-chip) 0 °C to +85 °C (on-chip) 0 °C to +85 °C (on-chip)

Diferenciadores clave

  • Modular port package with on-die temperature compensation (frente a MPX2010D)
  • Bidirectional ±25 mV differential output for flow direction (frente a MPX4100A (absolute 20–105 kPa))
  • 10 kPa FS precision with ±1% calibrated accuracy (frente a MPXM2053GS (50 kPa))
  • Single-supply 10–16 V operation, ratiometric to VS (frente a MPXV2010G (small-outline port))

Notas de diseño

The MPXM2010D outputs only 25 mV differential at full scale on a 10 V common-mode. Route the four signal traces as a guarded differential pair (VOUT+, VOUT-, plus shield trace tied to GND) directly to a low-offset instrumentation amplifier such as the INA128 or AD620. Keep traces ≤ 50 mm to limit pickup; a 0.1 µF X7R bypass capacitor placed within 5 mm of the sensor supply pin decouples the bridge. Estimated: with a typical 0.85 µV/√Hz INA128 input density and 1 kHz bandwidth, total front-end noise ≈ 27 µVrms, equivalent to ~0.1 % FS — well within calibration budget.

Do not apply pressure beyond 10 kPa on either port — the diaphragm will yield past the strain-gauge linear region and may permanently shift offset. For a Venturi or pitot array sized to drop up to 12 kPa at peak flow, derate the working point to 80 % FS and choose the next-higher MPX2010 series range (e.g., MPXM2053GS at 50 kPa) instead. The 16 V absolute supply maximum is also a common failure point: a 24 V industrial supply transients can punch through; place an SMAJ16CA TVS immediately at the supply pin.

Although the on-chip compensation curve holds the output linear over 0 °C to +85 °C, the ratiometric output still scales with supply. When the regulator powering the sensor shares a 4 mA loop with downstream load, voltage drop can shift the bridge. Use a dedicated linear regulator (TL431 shunt, or a low-dropout LP2985) for sensor excitation to keep the bridge stable within ±0.5 %. Estimated: a 50 mV ripple on a 10 V supply becomes ≈ 0.125 mV of output ripple — much smaller than the sensor noise floor, so external LC filtering is generally unnecessary if a low-noise LDO feeds the bridge.

Información de cumplimiento

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Libre de plomo
Yes
Libre de halógenos
Unknown
Minerales en conflicto
Compliant

RoHS and REACH compliance status not explicitly confirmed in the provided datasheets or distributor listings; request the latest material declaration directly from NXP or STMicroelectronics before volume production. The MPX2010 series was historically produced with lead-containing die attach before the 2006 RoHS transition; modern date-code shipments (2018 and later) are typically lead-free but should be verified per lot.

Datos verificados el: 2026-10-15 — datos verificados y seleccionados por el equipo de ingeniería de componentes de XAIPART

Búsquedas relacionadas

MPXM2010D MPXM2010D datasheet NXP MPXM2010D pressure sensor 10 kPa differential pressure sensor 5-SMD MPXM2010D modular port pressure sensor MPXM2010D for ventilator flow sensor MPXM2010D vs MPXM2010GS MPXM2010D drop-in replacement MPXM2010D buy price MPXM2010D vs MPX2010D low pressure piezoresistive sensor NXP MPXM2010D pinout 5-SMD module

Componentes & términos relacionados

NXP Semiconductors Freescale Semiconductor STMicroelectronics MPXM2010D MPXM2010GS MPXM2010DT1 MPX2010D MPXM2053GS pressure sensor piezoresistive sensor Wheatstone bridge differential pressure modular 5-SMD package LDO regulator instrumentation amplifier INA128 AD620 REF5025 RoHS AEC-Q100 transducer on-chip temperature compensation ratiometric output HVAC VAV
RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
Total: $0.00 USD
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ