SFP-10G-ZR-I-C - 10GBASE-ZR SFP+ 80km SMF 1550nm Industrial | Cisco
N.º de pieza: SFP-10G-ZR-I-C ✓ Activo| Cant. | Precio unitario | Total |
|---|---|---|
| 1 | $2850 | $2.850,00 |
| 10 | $2720 | $27.200,00 |
| 50 | $2580 | $129.000,00 |
| 100 | $2450 | $245.000,00 |
| 500 | $2300 | $1.150.000,00 |
SFP-10G-ZR-I-C Descripción general
A Small Form-Factor Pluggable Plus (SFP+) transceiver is a hot-swappable optical module used in 10 Gigabit Ethernet, 10G Fibre Channel, and OTN (Optical Transport Network) equipment. SFP+ is the standardized successor to the 1G SFP cage, sharing the same physical footprint but upgrading the electrical interface to SFF-8431 / SFF-8432 MSA-compliant signaling for 10 Gbps line rates. Within the broader taxonomy, SFP+ belongs to the pluggable optical transceiver family, which sits above fixed-port optics and below higher-density form factors such as QSFP+ and QSFP28.
Key features include a 1550 nm EML laser with APD receiver, DOM/DDM (Digital Optical Monitoring) support via a 2-wire serial interface per SFF-8472, multirate operation (10.3 Gbps Ethernet and 11.05/11.10 Gbps OTU2/OTU2e), LC duplex connector, and industrial-temperature operation from -40 °C to 85 °C. The module is designed to be Cisco-spec compliant rather than strictly IEEE 802.3ae standardized for the ZR reach class.
Technically, the module implements EML-based optics with APD reception and built-in CDR for jitter performance, with DOM exposing TX power, RX power, temperature, laser bias, and voltage for link diagnostics. The 1550 nm wavelength is chosen specifically to minimize chromatic dispersion over the 80 km SMF span.
Typical applications include long-haul data-center interconnect (DCI), metro Ethernet aggregation, service-provider transport rings, dark-fiber enterprise backbones, and OTN multiplexing of 10G client signals. When designing a link, engineers must perform a strict optical budget calculation (TX power − fiber loss − connector/splice loss ≥ RX sensitivity) and ensure the host switch accepts the industrial temperature grade.
Alternativas directas para SFP-10G-ZR-I-C — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
Herramienta de comparación rápida — seleccione piezas alternativas para compararlas lado a lado:
SFP-10G-ZR-I
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
SFP-10G-ZR
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
SFP-10G-ZR-C
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
SFP-10G-ZR-I-AO
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
SFP-10G-ZR-I-C
✅ Sustitución directa✓ En stock
$2300 / unidad
Ver hoja de datos →SFP-10G-ZR-CSC
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
SFP-10G-ZR-I-C Especificaciones (publicadas por el fabricante)
| Form Factor | SFP+ (pluggable) |
| Velocidad de datos | 10.3 Gbps (Ethernet) / 11.05-11.10 Gbps (OTU2/OTU2e) |
| Protocol | 10GBASE-ZR, 10GBASE-ZW, OTU2, OTU2e |
| Reach | Up to 80 km on SMF (G.652) |
| Wavelength | 1550 nm nominal |
| Fiber Type | Single-Mode Fiber (G.652 SMF) |
| Connector | LC duplex |
| Laser Type | 1550 nm EML |
| Temperatura de funcionamiento | -40 °C to +85 °C (Industrial grade) |
| Digital Optical Monitoring (DOM) | Yes (SFF-8472) |
| MSA Compliance | SFF-8431, SFF-8432, SFF-8472 |
| Standard Reference | Cisco-spec (not IEEE 802.3ae standardized at ZR reach) |
| OEM Coding | Cisco (programmed for Cisco platforms) |
| Hot-Swappable | Yes |
Interfaces y conectores de SFP-10G-ZR-I-C
No hay disponible una lista de interfaces publicada por el fabricante para SFP-10G-ZR-I-C. Consulte la documentación del fabricante para obtener detalles sobre conectores y cabeceras.
Consulte la documentación del fabricante para ver el patillaje completo del conector de expansión y la numeración de pines del conector.
Características de potencia y térmicas
| Temperatura de funcionamiento | -40 °C to +85 °C (Industrial grade) |
Parámetros de entrada de potencia y térmicos para SFP-10G-ZR-I-C según lo publicado por el fabricante.
Aplicaciones típicas
SFP-10G-ZR-I-C es adecuado para 6 aplicacións: Long-Haul Data-Center Interconnect (DCI), Metro Ethernet Aggregation Rings, Enterprise Dark-Fiber Backbone, 10G Fibre Channel SAN Extension, Mobile Backhaul (4G/5G Aggregation), Industrial / Outdoor Cabinet Deployment.
Long-Haul Data-Center Interconnect (DCI)
The SFP-10G-ZR-I-C delivers 10GBASE-ZR throughput over 80 km of G.652 SMF, which makes it ideal for interconnecting geographically separated data centers across a metro region. Its 1550 nm EML laser and APD receiver chain tolerate chromatic dispersion and attenuation over the full 80 km span, while the -40 °C to 85 °C industrial temperature rating allows deployment in outdoor splice cabinets and unconditioned meet-me rooms. Cisco-coded optics ensure plug-and-play operation in Cisco NCS, ASR 9000, Nexus 9300, and Catalyst 9500 platforms without DOM warnings, and DOM/DDM per SFF-8472 enables real-time optical-budget verification at commissioning and during operation. Compared with coherent DWDM optics, ZR is dramatically cheaper but limited to a single 10G wavelength per fiber pair.
Recomendado
Metro Ethernet Aggregation Rings
Service providers deploy the SFP-10G-ZR-I-C as a 10G client-side optical in metro aggregation nodes where link distances between central offices and POP sites routinely exceed 10 km and reach up to 80 km. The multirate capability supports 10GBASE-ZR Ethernet and OTU2/OTU2e for transport over DWDM line systems, allowing a single SKU to carry native Ethernet or be mapped into OTN containers. The industrial temperature rating is essential in street-side cabinets exposed to ambient swings, while the LC duplex connector pairs with standard metro fiber plant. Optical budget planning (TX power minus fiber loss minus connector/splice loss minus dispersion penalty) is mandatory before commissioning.
Recomendado
Enterprise Dark-Fiber Backbone
Enterprises operating private fiber plant between headquarters, regional offices, and campus buildings use the SFP-10G-ZR-I-C to extend 10G Ethernet across 40-80 km dark-fiber spans. Compared with a 1310 nm LR SFP+ limited to 10 km, the 1550 nm ZR optics push reach by an order of magnitude without active amplification, making them ideal for leased IRU fiber or municipal fiber networks. The -40 °C to 85 °C industrial grade handles outdoor enclosures, vault-mounted media converters, and unconditioned intermediate nodes. DOM/DDM exposes real-time TX/RX power, allowing network operations to detect fiber-plant issues such as degraded splices or water ingress before link failure occurs.
Recomendado
10G Fibre Channel SAN Extension
Storage architects use the SFP-10G-ZR-I-C for 10G Fibre Channel (10G FC) SAN extension between data halls, allowing synchronous replication and disaster-recovery mirroring across 80 km SMF. The multirate optics support both 10GbE and 10G FC line rates, which simplifies sparing and procurement. Industrial temperature rating allows deployment in equipment rooms without precision cooling, while DOM/DDM enables monitoring of optical-degradation trends that could impact replication latency and link integrity. For longer reaches or lower latency, dedicated DWDM transport or FC-specific long-reach SFP+ variants may be preferred.
Recomendado
Mobile Backhaul (4G/5G Aggregation)
Mobile network operators (MNOs) deploy the SFP-10G-ZR-I-C to backhaul 4G LTE and 5G NR aggregation nodes from cell-site routers to the core network across metro spans of 20-80 km. The -40 °C to 85 °C industrial grade tolerates outdoor cabinet environments, while the 1550 nm wavelength is well-suited to operator-owned single-mode fiber plant. Combined with Cisco ASR 9000 or NCS 540 cell-site routers, the module supports 10GbE and OTU2 transport for native Ethernet or OTN backhaul. Compared with CWDM or DWDM alternatives, ZR optics are simpler and lower-cost when only one or two 10G wavelengths per fiber pair are needed.
Recomendado
Industrial / Outdoor Cabinet Deployment
The "I" suffix and -40 °C to 85 °C rating make the SFP-10G-ZR-I-C specifically suited for industrial and outdoor-cabinet deployments where ambient temperature swings exceed commercial-grade limits. Typical installations include roadside traffic-management cabinets, utility substation communications, oil-and-gas wellhead telemetry, and rail signaling networks where temperature-controlled environments are unavailable. The module's SFP+ form factor fits any SFP+ cage, but host equipment must also be industrial-rated. Compared with commercial-grade SFP-10G-ZR (0 °C to 70 °C), the industrial variant prevents link degradation or laser failure in extreme cold or heat that would otherwise require heater/coolers or climate-controlled enclosures.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para SFP-10G-ZR-I-C — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | SFP-10G-ZR-I | SFP-10G-ZR | SFP-10G-ZR-C | SFP-10G-ZR-I-AO | SFP-10G-ZR-I-C (ProLabs) | SFP-10G-ZR-CSC |
|---|---|---|---|---|---|---|---|
| Brand | Cisco | Cisco | Cisco | Cisco | AddOn Networks | Amphenol ProLabs | Optcore |
| Package | SFP+ pluggable | SFP+ pluggable - same | SFP+ pluggable - same | SFP+ pluggable - same | SFP+ pluggable - same | SFP+ pluggable - same | SFP+ pluggable - same |
| Data Rate | 10.3 Gbps / 11.05-11.10 Gbps OTU2/OTU2e | 10.3 Gbps / OTU2/OTU2e - same | 10.3 Gbps / OTU2/OTU2e - same | 10.3 Gbps / OTU2/OTU2e - same | 10.3 Gbps - same | 10.3 Gbps - same | 10.3 Gbps - same |
| Wavelength | 1550 nm | 1550 nm - same | 1550 nm - same | 1550 nm - same | 1550 nm - same | 1550 nm - same | 1550 nm - same |
| Reach | 80 km on G.652 SMF | 80 km - same | 80 km - same | 80 km - same | 80 km - same | 80 km - same | 80 km - same |
| OEM Coding | Cisco | Cisco | Cisco | Cisco | AddOn (Cisco-compatible) | ProLabs (Cisco-compatible) | Optcore (Cisco-compatible) |
| Connector | LC duplex | LC duplex - same | LC duplex - same | LC duplex - same | LC duplex - same | LC duplex - same | LC duplex - same |
Diferenciadores clave
- Industrial temperature grade (-40 to 85 C) (frente a SFP-10G-ZR)
- Cisco OEM coding for plug-and-play Cisco deployment (frente a SFP-10G-ZR-I-AO (AddOn))
- Multirate 10GbE / OTU2 / OTU2e support (frente a Generic 10GBASE-ZR SFP+)
Notas de diseño
The Cisco SFP-10G-ZR-I-C is not standardized by IEEE 802.3ae at the 80 km ZR reach - it is built per Cisco specifications. While the SFP+ MSA (SFF-8431/8432) governs the electrical interface, the 80 km optical budget is Cisco-specific and may not interoperate cleanly with non-Cisco ZR modules on a Cisco host. Before deploying third-party equivalents, verify compatibility on the Cisco Optics-to-Device Compatibility Matrix at tmgmatrix.cisco.com and check the target IOS version for any DOM/DDM warnings that block the link.
For 80 km ZR links, perform a strict optical budget calculation: TX power minus fiber attenuation (typically 0.2 dB/km at 1550 nm) minus connector and splice losses (typically 0.3-0.5 dB each) minus dispersion penalty must exceed the receiver sensitivity with margin. Always include dispersion compensation if the link exceeds 60 km on older fiber with higher chromatic-dispersion coefficients. Allow at least 3 dB end-of-life margin to account for laser degradation and any future fiber splices.
The SFP-10G-ZR-I-C is rated for -40 °C to 85 °C operating temperature (industrial grade), but the host SFP+ cage must also support the full industrial range. In outdoor cabinets, ensure adequate airflow or conduction cooling for the cage, and consider conformal coating on the host board to prevent humidity-induced failures. SFP+ cages in indoor-only switches may not provide the full -40 °C to 85 °C ambient range even if the module itself is industrial-rated.
Información de cumplimiento
Compliance certifications for SFP-10G-ZR-I-C were not present in the Verified Web Data. Cisco-branded transceivers typically meet RoHS/REACH per Cisco's product environmental program, but this is not verified for this specific SKU and is marked unknown per data authenticity rules.