Semtech Corporation

SX1276MB1MAS - LoRa 433/868MHz Mbed Shield | Semtech

N.º de pieza: SX1276MB1MAS ✓ Activo
En stock Se envía en 1-3 días hábiles
Shield-format evaluation board Package 433 MHz and 868 MHz ISM bands Speed
Desde $26.3 USD / unidad
MOQ: 1 |
Precio actualizado: 2026-10-18
Precios por volumen
Cant. Precio unitario Total
1 $30.83 $30,83
10 $29.6 $296,00
100 $28.5 $2.850,00
500 $27.4 $13.700,00
1.000 $26.3 $26.300,00
ℹ️ Todos los precios están en USD

SX1276MB1MAS Descripción general

The Semtech SX1276MB1MAS is a LoRa Connect Mbed shield development board featuring the SX1276 sub-GHz LoRa transceiver, configured for the 433 MHz (LF) or 868 MHz (HF) ISM bands, with a U.FL antenna connector (antenna not included) and a through-hole shield form factor.

A sub-GHz RF transceiver module is a radio device that transmits and receives data in the license-free frequency bands below 1 GHz. Within the wireless connectivity hierarchy, it belongs to the category of ISM-band transceivers, which sits under RF transceivers, RF and wireless components, and semiconductors. The SX1276 device on this shield implements LoRa (Long Range) spread-spectrum modulation, the leading LPWAN physical-layer technology.

Key features include the SX1276 LoRa modem with ultra-long-range spread-spectrum communication, dual-band 433 MHz and 868 MHz configuration, LoRa modulation with high interference immunity, and a standard Mbed-compatible shield format for rapid prototyping with Mbed-enabled microcontroller boards. The U.FL (MHF) connector allows connection of an external antenna matched to the selected band.

Technically, the SX1276 integrates the LoRa modem plus a high-performance FSK/OOK modem in a single device, covering 137 MHz to 1020 MHz, with low active and sleep current consumption suited to battery-powered long-range links. The shield exposes the transceiver through the Mbed shield connector (SPI interface), letting developers evaluate LoRa link budgets, range, and modulation settings before committing to a custom PCB.

Typical applications include LPWAN node prototyping, smart agriculture and smart city sensor links, industrial telemetry, and long-range IoT gateways in the 433 MHz and 868 MHz ISM bands.

Design consideration: always attach a correctly tuned 433 MHz or 868 MHz antenna before transmitting; operating the SX1276 into an unmatched or absent load can stress the PA output stage.

This page synthesizes distributor pricing, related-module alternatives, and practical design notes not found in the manufacturer product page. Pricing references are as of 2026-10-19.

Alternativas directas para SX1276MB1MAS — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

Herramienta de comparación rápida — seleccione piezas alternativas para compararlas lado a lado:

SX1276MB1LAS

✅ Sustitución directa ⚠️ Especificaciones sin verificar
📦 Mbed shield, U.FL, through hole
same SX1276 Mbed shield, HF 868 MHz band configuration as primary config (vs 433 MHz LF), pin-to-pin identical board

📋 Alternativa de referencia (no en el catálogo)

SX1272MB2EAS

✅ Sustitución directa ⚠️ Especificaciones sin verificar
📦 Mbed shield, U.FL, through hole
SX1272 transceiver instead of SX1276 - lower max data rate and slightly reduced sensitivity (~-3 dB class), same shield footprint

📋 Alternativa de referencia (no en el catálogo)

SX1278MB1LAS

✅ Sustitución directa ⚠️ Especificaciones sin verificar
📦 Mbed shield, U.FL, through hole
SX1278 variant with different band-market configuration (433 MHz focus), same shield format and pinout family

📋 Alternativa de referencia (no en el catálogo)

SX1268

✅ Sustitución directa
📦 [DATA_NEEDED: package]
flagged as equivalent by distributor cross-reference (Xecor); newer generation, lower RX current, but different device family - verify shield-level compatibility before substitution

📋 Alternativa de referencia (no en el catálogo)

SX1276MB1MAS Especificaciones (publicadas por el fabricante)

Product Type LoRa Connect Mbed Shield (evaluation module)
Core Transceiver IC Semtech SX1276
Frequency Band 433 MHz and 868 MHz ISM bands
SX1276 Tuning Range 137 MHz to 1020 MHz
Modulation LoRa spread spectrum, FSK, OOK, GFSK
Antenna Connector U.FL (antenna not included)
Tipo de montaje Through Hole (Mbed shield form factor)
Technology LoRa LPWAN long-range spread spectrum
Interfaz SPI via Mbed shield connector
Application General ISM < 1 GHz transceiver evaluation
Compatible Ecosystem ARM Mbed-enabled development boards
Encapsulado Shield-format evaluation board

Interfaces y conectores de SX1276MB1MAS

No hay disponible una lista de interfaces publicada por el fabricante para SX1276MB1MAS. Consulte la documentación del fabricante para obtener detalles sobre conectores y cabeceras.

Consulte la documentación del fabricante para ver el patillaje completo del conector de expansión y la numeración de pines del conector.

Aplicaciones típicas

SX1276MB1MAS es adecuado para 6 aplicacións: LPWAN IoT Node Prototyping, Smart Agriculture Sensor Networks, Smart City Metering and Infrastructure, Industrial Telemetry and SCADA Links, Long-Range IoT Gateways and Backhaul Evaluation, RF Education and Wireless Lab Courses.

🧩

LPWAN IoT Node Prototyping

The SX1276MB1MAS is the fastest way to validate a LoRa LPWAN node design. The SX1276 transceiver provides ultra-long-range spread-spectrum communication with high interference immunity, and the Mbed shield format plugs directly onto any Mbed-enabled MCU board, removing RF layout risk from the prototype phase. Developers typically achieve kilometre-scale range in the 433 MHz or 868 MHz ISM bands using LoRa spreading factors of 7 to 12, trading data rate for link budget. Because the production SX1276 silicon is on board, firmware and RF parameters validated here carry directly into a custom PCB. Battery-life modeling using the SX1276's low sleep and RX currents can begin immediately, and Semtech's Mbed LoRa libraries accelerate first-packet time to under an hour.

🌾

Smart Agriculture Sensor Networks

Farm and greenhouse telemetry nodes span large areas with sparse infrastructure, making sub-GHz LoRa ideal. The SX1276MB1MAS lets agricultural engineers prototype soil-moisture, weather-station, and irrigation-controller links in the 433 MHz band, which penetrates vegetation better than 868 MHz or 2.4 GHz alternatives. The SX1276's high interference immunity maintains link integrity near metal irrigation equipment, and its chirp spread spectrum operates below the noise floor for maximum range. A typical workflow pairs the shield with a low-power MCU, logs RX sensitivity versus spreading factor in the field, and uses the results to size solar panels and batteries for the production node. U.FL antenna connection supports gain antennas for long hub-to-field links.

🏙️

Smart City Metering and Infrastructure

Water, gas, and electricity metering deployments in the 868 MHz band demand long battery life and robust urban penetration. The SX1276MB1MAS enables pre-deployment link testing across real city blocks before committing to hardware. The SX1276 LoRa modem's sensitivity allows multi-kilometre urban links at low transmit power, satisfying regional 868 MHz duty-cycle regulations while keeping cells large. Engineers use the shield to measure packet error rate versus distance, evaluate gateway placement, and tune spreading factor and coding rate per morphology class. Because LoRa has become the leading LPWAN choice for smart city LPWAN connectivity, ecosystem support, gateways, and network servers are mature, shortening time from prototype to pilot deployment.

🏭

Industrial Telemetry and SCADA Links

Factories and remote industrial sites need cable-free links for tank levels, pump status, and machine counters where wiring is costly. The SX1276MB1MAS supports evaluation of 433 MHz links, which handle obstructions and RF-noisy industrial environments well. The SX1276's FSK/OOK modem offers a low-latency fallback mode alongside LoRa, letting designers choose per-message between range and throughput. Typical bench tests measure link margin at 868 MHz with 10 mW output, confirming reliable operation through walls and machinery. Interference immunity of the LoRa modulation keeps telemetry stable near variable-frequency drives and welders. Once validated, the same SX1276 configuration migrates to a sealed production module with conformal-coated PCB.

🌐

Long-Range IoT Gateways and Backhaul Evaluation

Before building a LoRa gateway, engineers validate uplink performance with a node side of the SX1276MB1MAS. The shield characterizes receiver sensitivity, spreading-factor reach, and duty-cycle behavior of the 433/868 MHz bands that a production gateway must serve. LoRa's leading position in LPWAN means gateway silicon and network-server software are widely available, and range data collected with this shield directly informs antenna height and placement choices. The U.FL connector permits swept antenna testing with professional measurement gear, and dual-band configuration lets one bench setup cover both regional plans. Results feed directly into link-budget spreadsheets for star-of-stars network architecture planning across campus or district scale deployments.

🔧

RF Education and Wireless Lab Courses

Universities and training labs use the SX1276MB1MAS to teach spread-spectrum communication and LPWAN concepts hands-on. Students configure the SX1276's LoRa parameters - spreading factor, bandwidth, coding rate - over SPI and directly observe the range-versus-data-rate trade-off, something not visible with pre-integrated modules. The 433 MHz configuration is legal for experimentation in most regions without licenses under ISM rules, and the U.FL connector supports spectrum-analyzer observation of chirp signals. The Mbed ecosystem provides free online compiler and libraries, eliminating toolchain setup cost. Labs typically measure packet delivery ratio at fixed range across SF7 to SF12, concretely demonstrating the 20-plus dB link-budget spread available in LoRa modulation.

What is the Semtech SX1276MB1MAS?
The SX1276MB1MAS is a LoRa Connect Mbed shield from Semtech featuring the SX1276 sub-GHz transceiver, configured for the 433 MHz (LF) or 868 MHz (HF) ISM frequency bands. It provides a through-hole shield format with a U.FL antenna connector (antenna not included), allowing engineers to evaluate LoRa long-range spread-spectrum communication on any Mbed-compatible microcontroller board before designing a custom PCB. According to the Semtech product page, it is part of the LoRa Connect family of development tools.
What frequency bands does the SX1276MB1MAS support?
The SX1276MB1MAS is configured for the 433 MHz low band (LF) and the 868 MHz high band (HF) ISM bands. The underlying SX1276 transceiver IC itself tunes from 137 MHz to 1020 MHz, so the shield covers the license-free sub-GHz allocations used across Europe, China, and other regions for LPWAN deployments. Per Semtech documentation, the dual-band configuration lets one shield serve both 433 MHz and 868 MHz regulatory domains with an appropriate band-specific antenna.
Where can I buy the SX1276MB1MAS and how much does it cost?
The SX1276MB1MAS is available from major distributors including DigiKey, Mouser, LCSC, Arrow, and Ampheo. According to LCSC, pricing starts at approximately $30.83 per unit (as of 2026-10-19), with stock typically available for same-day shipment from DigiKey. Octopart lists 8 distributors carrying the part, so availability is generally good. Bulk discounts are modest for this development-tool class product; check each distributor for current quantity price breaks and lead times.
Where can I download the SX1276MB1MAS datasheet PDF?
The SX1276MB1MAS datasheet is available as a free PDF download from the Semtech official product page at semtech.com/products/wireless-rf/lora-connect/sx1276mb1mas, as well as from distributor pages on DigiKey, Mouser, and LCSC. A datasheet PDF of roughly 3.1 MB published 2015-05-04 is indexed by findic.us. The detailed SX1276 transceiver electrical specifications are in the separate SX1276 datasheet on the Semtech SX1276 product page, since the shield datasheet focuses on the board itself.
Does the SX1276MB1MAS include an antenna?
No, the SX1276MB1MAS does not include an antenna. Per the DigiKey product listing, the board provides a U.FL (MHF) antenna connector and is explicitly marked Antenna Not Included. You must attach an external antenna tuned to your operating band - a 433 MHz antenna for LF operation or an 868 MHz antenna for HF operation - via a U.FL-to-SMA pigtail or similar cable. Never transmit without an antenna connected, as an unmatched load can damage the SX1276 power amplifier output stage.
Is the SX1276MB1MAS compatible with Arduino boards?
The SX1276MB1MAS is designed as an ARM Mbed shield, so native compatibility targets Mbed-enabled boards. It can be adapted to Arduino-form-factor hosts with carrier adapters, since the SX1276 communicates over SPI, but wiring is not plug-and-play. For Arduino-specific prototyping, engineers often use dedicated SX1276/LoRa Arduino shields instead. For Mbed users, the shield connects directly and is supported by Mbed LoRa libraries and Semtech reference software, making it the fastest path to a working 433/868 MHz LoRa link.
What is the difference between SX1276MB1MAS and SX1276MB1LAS?
The SX1276MB1MAS and SX1276MB1LAS are the same Mbed shield platform built around the same SX1276 transceiver, differing in band configuration: the MAS variant targets the 433 MHz low band (LF), while the LAS variant is configured for the 868 MHz high band (HF) band plan. Both share the U.FL antenna connector, through-hole shield format, and LoRa modulation capability. Choose the MAS for 433 MHz-first designs and the LAS for 868 MHz deployments; the datasheet indicates the MAS can also serve the 868 MHz HF configuration.
What is the best drop-in replacement for the SX1276MB1MAS?
The closest drop-in replacement is the Semtech SX1276MB1LAS, the same Mbed shield package configured for the 868 MHz HF band - pin-to-pin identical, with only the band configuration differing. The SX1272MB2EAS shield is a same-format alternative based on the SX1272 transceiver with slightly reduced link budget. For newer designs, Semtech recommends evaluating the SX1268/SX1262 family, which offers lower RX current, but these use a different device and are not pin-compatible shields. All replacement options should be verified against your regulatory band requirements.
What can replace the SX1276MB1MAS?
Depending on your goal, the SX1276MB1MAS can be replaced by: the SX1276MB1LAS (same shield, HF band configuration), the SX1272MB2EAS (same shield format, SX1272-based, lower cost with modestly less sensitivity), or a third-party SX1276 breakout board wired over SPI. Distributor cross-reference tools such as DigiKey Cross Reference and LCSC Cross Reference also surface these candidates. Note the SX1268 mentioned by some cross-reference listings is a functional successor, not a shield-level drop-in replacement.
Is the SX1276MB1MAS suitable for LPWAN IoT node prototyping?
Yes, the SX1276MB1MAS is purpose-built for LPWAN prototyping. It combines the SX1276 LoRa transceiver - offering ultra-long-range spread-spectrum communication with high interference immunity - with the plug-on Mbed shield format, so a working 433/868 MHz LoRa node can be assembled in minutes. Typical prototype use cases include smart agriculture sensors, smart meters, and industrial telemetry. Because the SX1276 is the production silicon, RF and firmware work validated on this shield transfers directly to a custom PCB using the discrete SX1276 chip.
Which is better for 433 MHz designs, SX1276MB1MAS or SX1272MB2EAS?
For 433 MHz designs, the SX1276MB1MAS is the better choice. The SX1276 device tunes from 137 MHz to 1020 MHz and the MAS shield is explicitly configured for the 433 MHz LF band, whereas the SX1272 on the SX1272MB2EAS is optimized for higher bands and offers a lower maximum data rate and slightly reduced sensitivity. Semtech positions the SX1276 as the higher-performance part of the LoRa Connect generation. Both share the same Mbed shield footprint, so migration later is straightforward if your band plan changes.
When should I choose the SX1276MB1MAS over the SX1276 chip alone?
Choose the SX1276MB1MAS during evaluation and prototyping: it saves you from designing RF matching networks, antenna feeds, and crystal circuits, and its Mbed shield format lets you validate LoRa range, data rate, and link budget immediately. Choose the bare SX1276 chip only after your proof of concept is complete and you are ready for volume production, since the chip requires RF layout expertise. The shield typically costs around $30.83 (as of 2026-10-19), a small price to de-risk RF design before PCB tooling.
What are the key specifications of the SX1276MB1MAS that engineers should know?
The SX1276MB1MAS is a Semtech LoRa Connect Mbed shield using the SX1276 transceiver, configured for 433 MHz and 868 MHz ISM bands, with a U.FL antenna connector (antenna not included) and through-hole Mbed shield mounting. The SX1276 device tunes 137 MHz to 1020 MHz and supports LoRa spread-spectrum, FSK, GFSK, and OOK modulation. It interfaces to the host MCU via SPI. Pricing starts around $30.83 per unit as of 2026-10-19 at LCSC, with stock at DigiKey, Mouser, and Arrow.
Is the SX1276MB1MAS in stock and what is the lead time?
Yes, the SX1276MB1MAS is generally in stock. DigiKey's listing states Buy now, ships today, indicating same-day shipment from warehouse stock, and LCSC also lists the part as in-stock at approximately $30.8291. Octopart aggregates 8 distributors carrying inventory, including Mouser, Arrow, and Ampheo, which reduces single-source risk. Lead times for in-stock development boards are typically a few days for standard shipping; verify real-time stock on the distributor site before ordering, as development-tool inventory fluctuates with demand.
What Semtech transceiver is used on the SX1276MB1MAS and how does it work?
The SX1276MB1MAS carries the Semtech SX1276 LoRa Connect transceiver, which implements a LoRa long-range modem providing ultra-long-range spread-spectrum communication and high interference immunity, alongside a conventional FSK/OOK modem in the same device. The host microcontroller configures and reads the SX1276 over SPI, setting parameters such as spreading factor, bandwidth, and coding rate. LoRa's chirp spread spectrum achieves receiver sensitivity well below the noise floor, enabling kilometre-scale links in the 433 MHz and 868 MHz bands at milliwatt transmit power.

Datos de referencia de ingeniería para SX1276MB1MAS — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose the SX1276MB1MAS when you need to prototype or teach LoRa in the 433 MHz (LF) and/or 868 MHz (HF) ISM bands on an Mbed-enabled host - it puts production SX1276 silicon on a plug-on shield with a U.FL antenna feed, so field range tests can start the day the board arrives. Choose the SX1276MB1LAS instead if your deployment is 868 MHz-first with no 433 MHz requirement. Choose the SX1272MB2EAS only when lower cost matters more than maximum data rate and link budget. For new product starts where the board footprint is not fixed, seriously evaluate the newer SX1268/SX1262 family for lower receive current and better battery life - but note these are not shield-level drop-ins. For volume production, migrate from this shield to a custom PCB using the discrete SX1276 with the Semtech reference design.

Comparación con alternativas

Parámetro Este producto SX1276MB1LAS SX1272MB2EAS SX1278MB1LAS SX1268
Brand Semtech Semtech Semtech Semtech Semtech
Core Transceiver SX1276 SX1276 SX1272 SX1278 SX1268
Primary Frequency Band 433 MHz (LF) / 868 MHz (HF) 868 MHz (HF) primary 868/915 MHz class 433 MHz focus Sub-GHz (433/868 class)
Tuning Range 137 MHz to 1020 MHz (SX1276) 137 MHz to 1020 MHz 860 MHz to 930 MHz (SX1272) 137 MHz to 1020 MHz 150 MHz to 960 MHz
Modulation LoRa, FSK, GFSK, OOK LoRa, FSK, GFSK, OOK LoRa, FSK, GFSK, OOK LoRa, FSK, GFSK, OOK LoRa, FSK, GFSK
Relative Link Budget High (SX1276 class) High - identical silicon Moderately lower High (SX1278 class) High with lower RX current
Host Interface SPI via Mbed shield connector SPI via Mbed shield connector SPI via Mbed shield connector SPI via Mbed shield connector SPI (chip-level)

Diferenciadores clave

  • Dual-band LF/HF configuration on production silicon (frente a SX1272MB2EAS)
  • Mbed ecosystem integration (frente a Third-party SX1276 breakouts)
  • Trade-off: development tool pricing (frente a SX1276 chip)

Notas de diseño

Always connect a band-correct antenna (433 MHz for LF, 868 MHz for HF) via the U.FL connector before any transmit. The SX1276 PA is designed for a 50-ohm load; transmitting into an open or mismatched load raises VSWR and can degrade or destroy the output stage. Use a quality U.FL-to-SMA pigtail and verify antenna VSWR below 2:1 across your channel. Estimated: a 3 dB antenna mismatch alone can cost roughly half your radiated power and a proportional share of link budget.

The shield is an evaluation platform: keep RF wiring short when adapting to non-Mbed hosts via jumper wires, since long SPI lines above a few MHz SCLK pick up noise and cause CRC errors. Route MISO/MOSI/SCK/NSS away from switching regulators and add 100 nF decoupling at the host connector if the host board supply is shared. When migrating to production, copy the SX1276 reference-design matching network from the Semtech reference design rather than the shield schematic alone.

Respect regional duty-cycle limits: the European 868 MHz band enforces roughly 1 percent duty cycle per sub-band, which limits how aggressively you can test at high spreading factors. During bench range tests, sweep one parameter at a time (spreading factor, bandwidth, or coding rate) and log RSSI/SNR per packet; changing several at once makes link-budget attribution impossible. Also remember the antenna is not included - shipping delays on the correct 433 MHz antenna commonly stall first-light testing.

Información de cumplimiento

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Libre de plomo
Unknown
Libre de halógenos
Unknown
Minerales en conflicto
Unknown

Compliance data not stated in the provided web results for this development-tool product; consult the Semtech product page or distributor compliance certificates.

Datos verificados el: 2026-10-19 — datos verificados y seleccionados por el equipo de ingeniería de componentes de XAIPART

Búsquedas relacionadas

SX1276MB1MAS SX1276MB1MAS datasheet Semtech SX1276MB1MAS LoRa Mbed shield SX1276 433MHz 868MHz development board SX1276MB1MAS vs SX1276MB1LAS SX1276MB1MAS drop-in replacement LoRa Mbed shield 868 MHz buy price SX1276MB1MAS Arduino compatible SX1276 LoRa prototyping LPWAN evaluation what antenna for SX1276MB1MAS SX1276MB1MAS pinout U.FL is SX1276MB1MAS in stock

Componentes & términos relacionados

Semtech SX1276MB1MAS SX1276 SX1276MB1LAS SX1272MB2EAS SX1278MB1LAS SX1268 LoRa LoRa Connect LPWAN ARM Mbed sub-GHz transceiver ISM band 433 MHz 868 MHz U.FL connector chirp spread spectrum SPI RoHS IoT RF shield smart agriculture smart metering FSK modulation
RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
Total: $0.00 USD
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ