ISO122U vs ISO122P Comparaison
Comparaison détaillée côte à côte de ISO122U par Texas Instruments et ISO122P par Texas Instruments. Comparez les spécifications clés, les paramètres électriques, le conditionnement, le statut de cycle de vie, les prix et la disponibilité pour déterminer le meilleur composant pour vos exigences de conception.
Comparaison des spécifications
| Paramètre | ISO122U | ISO122P |
|---|---|---|
| Marque | Texas Instruments | Texas Instruments |
| Catégorie | Amplifier ICs | Amplifier ICs |
| Statut du cycle de vie | Actif | Actif |
| Statut du stock | In Stock | In Stock |
| Prix unitaire (USD) | $0,00 | $0,00 |
| Device Type | Precision isolation amplifier | — |
| Number of Channels | 1 circuit | — |
| Input Signal Range | ±10 V | — |
| Maximum Nonlinearity | 0.020% | 0.020% |
| Signal Bandwidth | 50 kHz | 50 kHz |
| Input Offset-Voltage Drift | 200 V/°C | 200 V/°C maximum |
| Isolation Voltage | 1500 Vrms | — |
| Power-Supply Range | 4.5 V to 18 V | — |
| VS1 Quiescent Current | 5 mA | 5 mA |
| VS2 Quiescent Current | ±5.5 mA | ±5.5 mA |
| Gain Configuration | Fixed unity gain | Fixed unity gain |
| External Components Required | None | — |
| High-Voltage Breakdown Test Coverage | 100% | — |
| Boîtier | 8-pin SOIC | — |
| Type de montage | Surface mount | Through-hole |
| Operating Voltage | ±4.5 V to ±18 V | — |
| Statut RoHS | [DATA_NEEDED: RoHS compliance status] | — |
| Plage de température de fonctionnement | [DATA_NEEDED: operating temperature range] | — |
| Product Type | — | Precision isolation amplifier |
| Number of Circuits | — | 1 circuit |
| Power Supply Range | — | 4.5 V to 18 V |
| Bipolar Supply Operation | — | ±10 V |
| High-Voltage Breakdown Rating | — | 1500 Vrms |
| Isolation Method | — | Duty-cycle modulation and demodulation |
| Differential Capacitive Barrier | — | 2 pF |
| ISO122P Package | — | 8-pin plastic DIP |
| Single-Supply Operation | — | Supported on the high-voltage side with a 5.1 V Zener-generated negative supply |
| High-Voltage Testing | — | 100% tested for rated high-voltage breakdown |