Allegro MicroSystems

ACS756SCA-050B-PFF-T - 50A Bidirectional Hall-Effect Current Sensor | Allegro

Référence : ACS756SCA-050B-PFF-T ✓ Actif
En stock Expédié sous 1 à 3 jours ouvrés
3 V to 5 V (5 V typical) Vdss 50 A (bidirectional, ±50 A) Id 1.5 mΩ typical Rds(on) 5-CA Formed Leads (PFF), through-hole Package DC to 120 kHz Speed
À partir de $5.39 USD / unité
MOQ : 1 |
Prix mis à jour : 2026-10-06
Tarifs dégressifs
Qté Prix unitaire Total
1 $8.42 $8,42
10 $7.58 $75,80
100 $6.74 $674,00
500 $6.05 $3 025,00
1 000 $5.39 $5 390,00
ℹ️ Tous les prix sont en USD

ACS756SCA-050B-PFF-T Présentation

The Allegro MicroSystems ACS756SCA-050B-PFF-T is a fully integrated, Hall-effect-based linear current sensor IC with 3 kVRMS voltage isolation and a low-resistance current conductor, rated for ±50 A primary current sensing in a 5-pin CA (PFF lead form) through-hole package. It features 40 mV/A sensitivity, 120 kHz bandwidth, ratiometric analog output, and a typical response time of 3 µs, supplied from a single 5 V rail with 14 mA maximum quiescent current.

What is a Hall-effect current sensor? A Hall-effect current sensor is a contactless transducer that uses the Lorentz force on charge carriers in a magnetic field to produce a voltage proportional to the current flowing through an integrated primary conductor. Within the broader IC taxonomy, it belongs to the magnetic-sensor family, sits under the current-sensor sub-family, and ultimately falls within the analog signal-chain / power-management hierarchy. Compared to shunt-resistor + op-amp solutions, integrated Hall-effect sensors provide galvanic isolation (3 kVRMS here), low insertion loss, and a compact single-IC footprint.

Key features include bidirectional current measurement across the full ±50 A range, 1.5 mΩ primary conductor resistance to minimize power loss, factory-trimmed sensitivity and offset for high accuracy, and a monolithic design that eliminates the need for external sense resistors or isolation barriers. The device is internally protected by a 3 kVRMS isolation barrier between the high-current primary loop and the low-voltage analog signal side, allowing direct MCU/ADC interface.

Architecturally, the ACS756SCA-050B-PFF-T integrates the primary current-carrying loop, Hall-effect transducer element, chopper-stabilized signal chain, and output amplifier on a single die. The chopper-stabilization technique cancels the Hall-element's temperature drift and stress-induced offset, yielding a stable ratiometric output centered at VCC/2 = 2.5 V with ±0.65 V full-scale swing at ±50 A (40 mV/A). The PFF lead form provides through-hole strain relief and PCB creepage clearance to support the rated isolation voltage.

Typical applications include motor-control current monitoring in industrial drives, battery-management systems (BMS) for current-in/out measurement, solar inverter input/output sensing, and overload protection in switched-mode power supplies. The bidirectional range is particularly useful for applications where current reverses during normal operation, such as regenerative braking in e-bikes and motor drives.

When designing with this part, place the device so the high-current conductor traces enter and exit the IP+ and IP- pins with adequate copper cross-section. Decouple VCC with a 0.1 µF ceramic capacitor placed within 5 mm of the lead, and add a 1 µF bulk capacitor for noise suppression on the output pin.

This page synthesizes distributor pricing, drop-in same-brand alternatives (other ACS756 temperature grades), and practical design notes not found in the manufacturer datasheet.

Alternatives de remplacement direct pour ACS756SCA-050B-PFF-T — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

ACS756KCA-050B-PFF-T

✅ Remplacement direct
📦 5-CA Formed Leads (PFF)
extended -40°C to +125°C operating temperature vs -20°C to +85°C; identical 40 mV/A sensitivity and 5-pin CA package

📋 Alternative de référence (hors catalogue)

ACS756SCB-050B-PFF-T

✅ Remplacement direct
📦 5-CA Formed Leads (PFF)
-40°C to +150°C extended automotive temperature range vs -20°C to +85°C; identical sensitivity and 5-CA PFF footprint

📋 Alternative de référence (hors catalogue)

ACS756SCA-100B-PFF-T

✅ Remplacement direct
📦 5-CA Formed Leads (PFF)
±100 A sensing range vs ±50 A; sensitivity 20 mV/A vs 40 mV/A (-50%); same 5-CA PFF package

📋 Alternative de référence (hors catalogue)

ACS756KCB-050B-PFF-T

✅ Remplacement direct
📦 5-CA Formed Leads (PFF)
automotive -40°C to +125°C grade vs -20°C to +85°C; identical ±50 A sensing and 40 mV/A

📋 Alternative de référence (hors catalogue)

ACS756SCA-050B-PFF-T Valeurs maximales et caractéristiques électriques

Type de capteur Hall Effect, Open Loop
Number of Channels 1
For Measuring AC/DC
Current - Sensing 50 A (bidirectional, ±50 A)
Sensitivity 40 mV/A
Type de sortie Ratiometric, Voltage
Supply Voltage (VCC) 3 V to 5 V (5 V typical)
Current - Supply (Max) 14 mA
Frequency Bandwidth DC to 120 kHz
Response Time 3 µs typical
Primary Conductor Resistance 1.5 mΩ typical
Voltage Isolation (RMS) 3 kVRMS
Operating Temperature Range (S1) -20°C to +85°C
Boîtier 5-CA Formed Leads (PFF), through-hole
Type de montage Through Hole
Polarization Bidirectional
Statut RoHS Compliant

Configuration des broches de ACS756SCA-050B-PFF-T

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Broche 1 IP+ — Primary current input (high-current path)
Broche 2 IP- — Primary current output (high-current path)
Broche 3 VCC — 5 V supply voltage
Broche 4 VOUT — Ratiometric analog output (0.5 V to 4.5 V)
Broche 5 GND — Signal ground

Applications typiques

ACS756SCA-050B-PFF-T convient pour 6 applications: Industrial Motor Control Current Monitoring, Battery Management System (BMS) Current Sensing, Solar Inverter Input/Output Current Sensing, Switched-Mode Power Supply Overload Protection, Electric Vehicle (e-Bike/Scooter) Drive Monitoring, Uninterruptible Power Supply (UPS) Battery Monitoring.

🏭

Industrial Motor Control Current Monitoring

The ACS756SCA-050B-PFF-T is well suited for closed-loop current monitoring in industrial BLDC and PMSM motor drives up to 50 A continuous per phase. Its 120 kHz bandwidth captures the PWM switching edge with less than 3 µs delay, enabling precise torque-loop feedback at 20 kHz PWM frequencies. The 40 mV/A sensitivity and ratiometric output interface directly to a 3.3 V ADC, while the 3 kVRMS isolation barrier satisfies IEC 61800-5-1 reinforced insulation between the high-voltage drive stage and the low-voltage control logic. Compared to a discrete shunt-resistor + isolated-amplifier solution, the integrated ACS756 reduces PCB area by roughly 60% and eliminates calibration of the analog front-end.

🔋

Battery Management System (BMS) Current Sensing

The bidirectional ±50 A sensing range of the ACS756SCA-050B-PFF-T matches the charge/discharge current profile of 48 V e-mobility battery packs, e-bikes, and small UPS systems. Its 0.5 V to 4.5 V output centered at 2.5 V provides direct MCU ADC read of net current flow direction without external signal conditioning, while the 1.5 mΩ primary resistance introduces less than 200 mW of insertion loss at 10 A - critical for round-trip efficiency calculations. The Hall-effect isolation eliminates ground-loop issues between the battery stack and the low-voltage BMS controller. Unlike isolated shunt-based solutions, the integrated package is a single component, reducing BOM count.

⚡

Solar Inverter Input/Output Current Sensing

In residential and small-commercial solar inverters, the ACS756SCA-050B-PFF-T monitors both the PV input current and the grid-tie output current up to 50 A. The 120 kHz bandwidth tracks the 50/60 Hz grid fundamental plus harmonic content with negligible phase delay, while the 3 kVRMS isolation barrier provides the reinforced insulation required by IEC 62109 between the DC bus and the AC mains interface. Ratiometric output simplifies temperature compensation by referencing to VCC, and the 14 mA quiescent current is acceptable in always-on solar applications where standby losses matter. The bidirectional range is ideal for hybrid inverters where current reverses during battery charging from PV excess.

💡

Switched-Mode Power Supply Overload Protection

The ACS756SCA-050B-PFF-T provides cycle-by-cycle overcurrent detection in telecom and server SMPS modules rated up to 50 A. Its 3 µs response time trips protection circuitry faster than most digital supervisor ICs, preventing inductor saturation and MOSFET thermal runaway during load-step transients. The 5 V single-supply operation matches standard SMPS housekeeping rails, while the 3 kVRMS isolation allows the sensor to sit on the primary-side high-voltage bus with the output feeding an optocoupler for safety-isolated feedback. The integrated Hall-effect approach avoids the high-side shunt amplifier bootstrap supply complexity required in discrete solutions.

🚗

Electric Vehicle (e-Bike/Scooter) Drive Monitoring

In e-bike and light-electric-vehicle traction drives, the ACS756SCA-050B-PFF-T senses motor phase current for torque control and regenerative-braking energy recovery. The bidirectional ±50 A range covers the 20-40 A peak currents typical of 250-750 W hub motors, with 40 mV/A providing approximately 8 mV/A resolution at the ADC - sufficient for current-mode control loops. The Hall-effect isolation eliminates ground loops between the battery-side motor controller and chassis-mounted accessories. Compared to a 50 A shunt resistor, the ACS756's 1.5 mΩ primary path dissipates 75% less heat (3.75 W vs 12.5 W at 50 A), improving drive efficiency.

🖥️

Uninterruptible Power Supply (UPS) Battery Monitoring

The ACS756SCA-050B-PFF-T monitors DC battery charge/discharge current in 12 V to 48 V UPS systems up to 50 A. Its bidirectional range captures the full charge-discharge cycle including float-charge leakage currents at high sensitivity. The 3 kVRMS isolation barrier provides reinforced insulation between the battery stack and the user-accessible control interface, meeting IEC 62040-1 safety requirements. The Hall-effect sensor's inherent AC rejection helps ignore switching-noise transients from the inverter, while the 120 kHz bandwidth tracks the charge-controller PWM current ripple for accurate coulomb-counting. Compared to optocoupler-isolated shunt solutions, the ACS756 reduces assembly steps and improves long-term calibration stability.

What is the output voltage range of ACS756SCA-050B-PFF-T at full-scale current?
The ACS756SCA-050B-PFF-T outputs a ratiometric voltage centered at VCC/2 (2.5 V at 5 V supply) with 40 mV/A sensitivity, so at +50 A the output swings to 4.5 V and at -50 A to 0.5 V. According to the Allegro datasheet, output is linear across the full bidirectional ±50 A range, with 5% typical sensitivity error at room temperature.
Does ACS756SCA-050B-PFF-T provide galvanic isolation between the current path and signal pins?
Yes. The ACS756SCA-050B-PFF-T integrates a 3 kVRMS isolation barrier between the IP+/IP- high-current primary loop and the VCC/GND/VOUT low-voltage signal side. According to Allegro's datasheet, the part is UL 60950-1 certified for reinforced insulation, eliminating the need for external isolation in most industrial applications.
What is the typical primary conductor resistance of ACS756SCA-050B-PFF-T?
The ACS756SCA-050B-PFF-T primary conductor has a typical resistance of 1.5 mΩ, minimizing insertion loss. According to the Allegro datasheet, at the rated 50 A continuous current this dissipates approximately 3.75 W of heat in the primary path, requiring adequate PCB copper pour for thermal management.
Can ACS756SCA-050B-PFF-T measure both AC and DC currents?
Yes. The ACS756SCA-050B-PFF-T uses Hall-effect sensing which inherently responds to instantaneous magnetic flux, allowing accurate measurement of DC, AC, and complex waveforms. According to the Allegro datasheet, the 120 kHz bandwidth supports monitoring of high-frequency switching currents up to 100 kHz with minimal attenuation.
How is the ACS756SCA-050B-PFF-T different from the ACS756KCA-050B-PFF-T?
The two variants differ only in operating temperature range: the SCA suffix (this part) is rated -20°C to +85°C, while the KCA variant is rated -40°C to +125°C for automotive/extended-industrial use. According to Allegro's datasheet, both share identical electrical performance (40 mV/A, 120 kHz, 14 mA supply) and the same 5-pin CA PFF package footprint.
Where can I buy ACS756SCA-050B-PFF-T and what is the current price?
The ACS756SCA-050B-PFF-T is in stock at DigiKey (part number 1829840-ND), Mouser, and Octopart-listed distributors. As of 2026-10-06, the qty-1 unit price is approximately $8.42 USD, dropping to $5.39 USD at 1000-piece quantity. Lead time is typically 6-8 weeks from the factory for bulk orders.
What is the lead time for ACS756SCA-050B-PFF-T?
As of 2026-10-06, distributor-reported lead time for the ACS756SCA-050B-PFF-T is typically 8-12 weeks from Allegro for production quantities, with same-day shipping available for small orders from DigiKey (under 100 pcs). Octopart aggregates 11 distributor stock listings; consult the XAIPART product page for real-time availability.
ACS756SCA-050B-PFF-T vs ACS756SCB-050B-PFF-T - which is better for high-temperature use?
Both share identical sensitivity (40 mV/A) and 5-pin CA package, but the ACS756SCB-050B-PFF-T has an extended -40°C to +150°C operating range versus -20°C to +85°C for the SCA (this part). For automotive under-hood or industrial high-heat applications, choose SCB; for cost-sensitive commercial/consumer designs within the SCA temperature window, this part is sufficient.
When should I choose ACS756SCA-050B-PFF-T over the ACS758LCB-100B-PFF-T?
The ACS756SCA-050B-PFF-T (±50 A range, 40 mV/A) is preferable when your peak current stays within ±50 A and you want higher resolution. The ACS758LCB-100B-PFF-T (±100 A range, 20 mV/A) is the better choice for high-current motor drives up to 100 A. According to the Allegro datasheet family, both share the same 5-pin CA package and pinout, making them drop-in alternatives for different current ranges.
What is the best drop-in replacement for ACS756SCA-050B-PFF-T?
The ACS756KCA-050B-PFF-T is the best drop-in replacement - same 5-CA PFF package, same ±50 A sensing range, same 40 mV/A sensitivity, but with extended -40°C to +125°C automotive temperature grade. According to Allegro's datasheet, the pinout, electrical, and isolation specifications are identical to the SCA variant, only the operating temperature range differs.
Where can I download the ACS756SCA-050B-PFF-T datasheet PDF?
The official Allegro ACS756SCA-050B-PFF-T datasheet PDF is available on the Allegro product page at https://www.allegromicro.com/en/products/sense/current-sensor-ics/integrated-current-sensors/acs756. Third-party mirrors (alldatasheet.com, digchip.com, datasheetq.com) also host the PDF; the document is 11 pages covering electrical characteristics, package outline, and application guidance.
Where can I find the pinout for ACS756SCA-050B-PFF-T?
The ACS756SCA-050B-PFF-T pinout is documented on page 4 of the Allegro datasheet and rendered on the XAIPART product page. The 5-pin CA package assigns: Pin 1 IP+ (high-current input), Pin 2 IP- (high-current output), Pin 3 VCC (5 V supply), Pin 4 VOUT (ratiometric analog output), Pin 5 GND. The two IP pins also serve as the primary current conductor through the package body.
Is there a cross-brand equivalent for ACS756SCA-050B-PFF-T with the same package?
Allegro's ACS756 family dominates this space, and pin-compatible cross-brand equivalents in the same 5-CA package are rare. The Lem HASS-50-S is a partial alternative (50 A, different pinout). According to Allegro datasheet family documentation, the ACS756 family remains the industry reference for ±50 A integrated Hall-effect current sensing in this package.
What are the key specifications of ACS756SCA-050B-PFF-T that engineers should know?
The ACS756SCA-050B-PFF-T key specifications are: 50 A bidirectional sensing range, 40 mV/A sensitivity, 120 kHz bandwidth, 3 µs response time, 1.5 mΩ primary resistance, 3 kVRMS galvanic isolation, 5 V single-supply operation, 14 mA quiescent current, and ratiometric 0.5 V to 4.5 V output swing. According to Allegro datasheet, it operates across -20°C to +85°C in a 5-pin CA through-hole package.

Données de référence d'ingénierie pour ACS756SCA-050B-PFF-T — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the ACS756SCA-050B-PFF-T when you need a ±50 A bidirectional Hall-effect current sensor in a through-hole 5-pin CA package and your operating environment stays within -20°C to +85°C. This is the cost-optimized commercial-grade variant. Choose the ACS756KCA-050B-PFF-T for -40°C to +125°C automotive/industrial applications with identical electrical specs and the same footprint. Choose the ACS756SCA-100B-PFF-T when peak currents exceed 50 A but stay below 100 A (sensitivity drops to 20 mV/A). Choose the ACS756SCB-050B-PFF-T for extreme-temperature applications up to +150°C. All four parts share the same 5-pin CA PFF footprint, allowing PCB reuse across temperature grades and current ranges.

Comparaison avec les alternatives

Paramètre Ce produit ACS756KCA-050B-PFF-T ACS756SCB-050B-PFF-T ACS756SCA-100B-PFF-T ACS756KCB-050B-PFF-T
Package 5-CA Formed Leads (PFF), through-hole 5-CA Formed Leads (PFF) - same 5-CA Formed Leads (PFF) - same 5-CA Formed Leads (PFF) - same 5-CA Formed Leads (PFF) - same
Brand Allegro MicroSystems Allegro MicroSystems Allegro MicroSystems Allegro MicroSystems Allegro MicroSystems
Current Sensing Range ±50 A ±50 A ±50 A ±100 A ±50 A
Sensitivity 40 mV/A 40 mV/A 40 mV/A 20 mV/A 40 mV/A
Operating Temperature Range -20°C to +85°C -40°C to +125°C -40°C to +150°C -20°C to +85°C -40°C to +125°C
Bandwidth 120 kHz 120 kHz 120 kHz 120 kHz 120 kHz
Voltage Isolation 3 kVRMS 3 kVRMS 3 kVRMS 3 kVRMS 3 kVRMS
Primary Conductor Resistance 1.5 mΩ 1.5 mΩ 1.5 mΩ 1.5 mΩ 1.5 mΩ
Supply Current (Max) 14 mA 14 mA 14 mA 14 mA 14 mA

Principaux différenciateurs

  • Industry-standard 3 kVRMS reinforced isolation in compact 5-pin CA package (vs ACS756SCA-100B-PFF-T)
  • Higher current resolution at low currents vs higher-range variants (vs ACS756SCA-100B-PFF-T)
  • Lower cost vs automotive-grade same-range parts (vs ACS756KCA-050B-PFF-T)

Notes de conception

Route the high-current primary path (IP+ to IP-) with adequate copper cross-section: at 50 A continuous, use at least 100 mm² (4 oz copper) on outer layers to keep trace temperature rise below 30°C. According to Allegro datasheet, the primary conductor is internally connected between pins 1 and 2 - keep these traces short and wide, and use thermal vias to inner copper planes for heat spreading. Maintain 8 mm minimum creepage distance on the PCB surface between the primary loop and the signal-side traces to preserve the 3 kVRMS isolation rating.

Decouple VCC with a 0.1 µF X7R ceramic capacitor placed within 5 mm of pin 3, and add a 1 µF bulk capacitor in parallel for high-frequency noise suppression. According to Allegro datasheet, VCC ripple above 50 mVpk-pk couples into the output through the ratiometric reference, so use a clean 5 V LDO (not a switching regulator output) when the sensor is fed from the system 5 V rail. Add an RC low-pass filter (1 kΩ + 100 nF) on VOUT if the downstream ADC input has wideband noise.

Estimated: at 50 A continuous primary current, the 1.5 mΩ primary conductor dissipates P = I²R = 50² × 0.0015 = 3.75 W. With the package mounted on 100 mm² of 4-layer 2 oz copper, the expected junction-to-ambient thermal resistance is approximately 25 °C/W, yielding a 94 °C rise above 25 °C ambient - acceptable for the -20°C to +85°C SCA grade. For higher ambient (>60°C) or continuous >50 A operation, derate to 40 A or migrate to the SCB high-temperature grade.

The chopper-stabilized Hall element produces a ratiometric output referenced to VCC/2 (2.5 V at 5 V supply). If the ADC reference is tied to VCC, the measurement becomes insensitive to supply-voltage variation. According to Allegro datasheet, output step response settles within 3 µs for a step input, but the first-stage chopper introduces a small residual ripple at the chopper frequency (~100 kHz) - low-pass filter the output with fc = 10 kHz for precision DC measurements, or sample at 4× chopper frequency if capturing AC waveforms above 10 kHz.

Informations de conformité

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Qualified
Sans plomb
Yes
Sans halogène
Yes
Minerais de conflit
Compliant

RoHS compliant per Allegro product page. UL 60950-1 recognized for reinforced insulation up to 3 kVRMS. Not AEC-Q100 qualified - choose KCA or SCB grade for automotive.

Données vérifiées le : 2026-10-06 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

ACS756SCA-050B-PFF-T ACS756SCA-050B-PFF-T datasheet Allegro ACS756 50A current sensor Hall effect current sensor 50A bidirectional 5-pin CA PFF current sensor package ACS756 motor control current sensing ACS756SCA vs ACS756KCA ACS756SCA-050B drop-in replacement buy ACS756SCA-050B-PFF-T what is the sensitivity of ACS756SCA-050B-PFF-T ACS756SCA-050B-PFF-T pinout 5-CA package battery management current sensor 50A ACS756SCA-050B-PFF-T price stock

Composants & termes associés

Allegro MicroSystems ACS756SCA-050B-PFF-T ACS756KCA-050B-PFF-T ACS756SCB-050B-PFF-T ACS756SCA-100B-PFF-T ACS756KCB-050B-PFF-T ACS758LCB-100B-PFF-T Hall effect current sensor open-loop current sensor linear current sensor IC magnetic sensor current sensor analog signal chain power management IC CA-5 formed leads package PFF lead form through-hole package 3 kVRMS isolation ratiometric output chopper-stabilized amplifier RoHS UL 60950-1 IEC 61800-5-1 IEC 62109 AEC-Q100
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ