AD4130-4BCPZ Présentation
An ADC (analog-to-digital converter) is a device that converts continuous analog signals into discrete digital numbers. The AD4130-4 is a sigma-delta ADC, which uses oversampling and noise shaping to achieve high resolution (24 bits) and excellent noise performance for low-bandwidth signals. It belongs to the family of precision data converters, which are essential in industrial process control, medical instrumentation, and smart sensor nodes. The integration of a PGA and multiplexer reduces external component count and simplifies system design.
Key features include 4 differential or 8 single-ended/pseudo-differential inputs, a crosspoint multiplexer that allows any input pair to be routed to the PGA and ADC, and built-in diagnostic functions such as open-wire detection, internal temperature sensor, reference detection, and analog input overvoltage/undervoltage detection. The device also supports duty cycling modes (1/4 or 1/16) to reduce average current to as low as 5 μA, and a standby mode at 0.5 μA and power-down mode at 0.1 μA.
The AD4130-4 uses a 24-bit sigma-delta modulator with a digital filter, providing high accuracy and noise rejection. The smart sequencer and per-channel configuration minimize host processor load, while the deep 256-sample FIFO allows autonomous data collection. The SPI interface enables easy integration with microcontrollers. The device is specified for operation from -40°C to +125°C, suitable for industrial environments.
Typical applications include industrial process control (4-20 mA loops), temperature and pressure measurement, battery monitoring, and portable medical devices. Its ultra-low power consumption and integrated diagnostics make it particularly suited for smart transmitters and IoT sensor nodes.
When designing with the AD4130-4, ensure proper decoupling of the analog supply and reference pins, and use a clean ground plane to minimize noise. The SPI interface should be isolated if used in noisy industrial environments.
Alternatives de remplacement direct pour AD4130-4BCPZ — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :
AD4130-4BCPZ-RL7
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
AD4130-8BCPZ
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
AD4130-4BCPZ Valeurs maximales et caractéristiques électriques
| Résolution | 24 Bit |
| Number of Inputs | 4 Differential or 8 Single-Ended/Pseudo-Differential |
| Input Type | Differential, Single-Ended, Pseudo-Differential |
| Data Interface | SPI |
| Architecture | Sigma-Delta |
| Supply Voltage Range | 1.71 V to 3.6 V |
| Current Consumption (Gain=1) | 28.5 μA |
| Current Consumption (Gain=128) | 32.5 μA |
| Duty Cycling Current (1/16) | 5 μA |
| Standby Current | 0.5 μA |
| Power-Down Current | 0.1 μA |
| Plage de température de fonctionnement | -40°C to +125°C |
| Boîtier | 32-LFCSP (5x5 mm) |
| Type de montage | Surface Mount |
| FIFO Depth | 256 Samples |
| Diagnostics | Open-Wire Detection, Internal Temp Sensor, Reference Detection, Overvoltage/Undervoltage Detection |
Configuration des broches de AD4130-4BCPZ
| Broche 1 | AVDD — Analog power supply |
| Broche 2 | AVSS — Analog ground |
| Broche 3 | AIN0 — Analog input 0 |
| Broche 4 | AIN1 — Analog input 1 |
| Broche 5 | AIN2 — Analog input 2 |
| Broche 6 | AIN3 — Analog input 3 |
| Broche 7 | AIN4 — Analog input 4 |
| Broche 8 | AIN5 — Analog input 5 |
| Broche 9 | AIN6 — Analog input 6 |
| Broche 10 | AIN7 — Analog input 7 |
| Broche 11 | REFIN+ — Positive reference input |
| Broche 12 | REFIN- — Negative reference input |
| Broche 13 | DVDD — Digital power supply |
| Broche 14 | DGND — Digital ground |
| Broche 15 | SCLK — SPI clock |
| Broche 16 | DIN — SPI data input |
| Broche 17 | DOUT — SPI data output |
| Broche 18 | CS — Chip select |
| Broche 19 | SYNC — Synchronization input |
| Broche 20 | GPIO0 — General purpose I/O |
| Broche 21 | GPIO1 — General purpose I/O |
| Broche 22 | GPIO2 — General purpose I/O |
| Broche 23 | GPIO3 — General purpose I/O |
| Broche 24 | RESET — Reset input |
| Broche 25 | PDR — Power-down reset |
| Broche 26 | CLK — External clock input |
| Broche 27 | VIO — I/O supply voltage |
| Broche 28 | AVDD — Analog power supply |
| Broche 29 | AVSS — Analog ground |
| Broche 30 | EP — Exposed pad (thermal) |
| Broche 31 | NC — No connect |
| Broche 32 | NC — No connect |
Applications typiques
AD4130-4BCPZ convient pour 6 applications: Industrial Process Control, Battery-Powered IoT Sensors, Medical Instrumentation, Smart Agriculture, Test and Measurement, Energy Monitoring.
Industrial Process Control
The AD4130-4BCPZ is ideal for 4-20 mA loop-powered transmitters and industrial process control. Its ultra-low power consumption (28.5 μA) allows operation from loop power, and the integrated diagnostics (open-wire detection, overvoltage/undervoltage) enhance system reliability. The 24-bit resolution and PGA enable precise measurement of temperature, pressure, and flow. The SPI interface simplifies connection to a host microcontroller, and the smart sequencer reduces processor load. With a supply range of 1.71 V to 3.6 V, it can be powered directly from the loop's voltage regulator.
Recommandé
Battery-Powered IoT Sensors
For battery-powered IoT sensor nodes, the AD4130-4BCPZ's ultra-low power consumption is critical. With duty cycling, average current can be reduced to 5 μA, extending battery life. The device supports 8 single-ended inputs, allowing multiple sensors (temperature, humidity, gas) to be monitored. The integrated FIFO and sequencer enable autonomous data collection, minimizing host wake-ups. The 24-bit resolution ensures accurate measurement of small sensor signals. The wide operating temperature range (-40°C to +125°C) suits outdoor deployments.
Recommandé
Medical Instrumentation
In medical devices like wearable monitors and diagnostic equipment, the AD4130-4BCPZ provides high precision and low power. Its 24-bit resolution and low noise are suitable for biopotential measurements (ECG, EEG) when combined with an external instrumentation amplifier. The integrated diagnostics help ensure patient safety. The small 5x5 mm LFCSP package is ideal for space-constrained designs. The SPI interface allows easy integration with medical-grade microcontrollers. The device's low current consumption is essential for battery-operated portable devices.
Recommandé
Smart Agriculture
The AD4130-4BCPZ is well-suited for smart agriculture applications such as soil moisture and weather monitoring. Its ultra-low power consumption enables solar-powered or battery-operated nodes. The multiple input channels allow connection of various sensors (soil moisture, temperature, rain gauge). The duty cycling mode reduces average current, extending field life. The device's wide temperature range and robust diagnostics ensure reliable operation in harsh outdoor environments. The SPI interface simplifies data collection to a central gateway.
Recommandé
Test and Measurement
In portable test and measurement equipment, the AD4130-4BCPZ offers high resolution and low power. Its 24-bit sigma-delta architecture provides accurate DC measurements, and the integrated PGA allows scaling of small signals. The device's fast settling time and SPI interface enable high-speed data acquisition. The small package and low power make it ideal for handheld multimeters and data loggers. The diagnostics help detect sensor faults. The device can be powered from a single lithium-ion cell (3.6 V) with a low-dropout regulator.
Recommandé
Energy Monitoring
The AD4130-4BCPZ can be used in energy monitoring systems for measuring voltage and current with high accuracy. Its 24-bit resolution and low noise enable precise power calculations. The multiple input channels allow simultaneous measurement of multiple phases. The ultra-low power consumption is beneficial for smart meters that operate on batteries or energy harvesting. The integrated diagnostics help detect tampering or faults. The SPI interface allows connection to a metering SoC. The device's wide temperature range suits outdoor installation.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour AD4130-4BCPZ — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | AD4130-4BCPZ-RL7 | AD4130-8BCPZ | AD7124-4BRUZ | AD7124-8BCPZ | MAX11254 |
|---|---|---|---|---|---|---|
| Package | 32-LFCSP (5x5 mm) | 32-LFCSP (5x5 mm) - same | 32-LFCSP (5x5 mm) - same | 24-Lead TSSOP | 32-Lead LFCSP | 32-TQFN |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Maxim Integrated |
| Resolution | 24 Bit | 24 Bit | 24 Bit | 24 Bit | 24 Bit | 24 Bit |
| Supply Voltage Range | 1.71 V to 3.6 V | 1.71 V to 3.6 V | 1.71 V to 3.6 V | 2.7 V to 3.6 V | 2.7 V to 3.6 V | 2.7 V to 3.6 V |
| Current Consumption (Gain=1) | 28.5 μA | 28.5 μA | 28.5 μA | 350 μA | 350 μA | 25 μA |
| Number of Inputs | 4 Differential or 8 Single-Ended | 4 Differential or 8 Single-Ended | 8 Differential or 16 Single-Ended | 4 Differential or 8 Single-Ended | 8 Differential or 16 Single-Ended | 2 Differential or 4 Single-Ended |
| Duty Cycling | Yes (1/4, 1/16) | Yes (1/4, 1/16) | Yes (1/4, 1/16) | No | No | No |
| Integrated Diagnostics | Yes | Yes | Yes | No | No | No |
Principaux différenciateurs
- Ultra-low power consumption of 28.5 μA at gain=1 (vs AD7124-4BRUZ)
- Integrated duty cycling reduces average current to 5 μA (vs AD7124-4BRUZ)
- Built-in diagnostics for safety-critical applications (vs MAX11254)
Notes de conception
The AD4130-4BCPZ operates from a single analog supply of 1.71 V to 3.6 V. Use a low-noise LDO such as the ADP150 to provide a clean supply. Decouple AVDD and DVDD with 0.1 μF and 10 μF capacitors placed close to the pins. The reference inputs should be decoupled with 0.1 μF and 1 μF capacitors to ensure stable operation.
For optimal performance, use a solid ground plane and separate analog and digital ground planes if necessary. Place the ADC close to the sensor to minimize trace length. Route analog inputs away from digital signals to reduce noise coupling. Use a 4-layer PCB with dedicated power and ground planes for best results.
Avoid exceeding the absolute maximum ratings on any pin. Ensure the SPI lines are not driven above VIO. The exposed pad (EP) must be soldered to the ground plane for thermal and electrical performance. Do not leave unused inputs floating; connect them to AVSS or configure them as outputs. Use the internal temperature sensor for diagnostics if needed.
Informations de conformité
RoHS compliant per Analog Devices product page. Not AEC-Q100 qualified.