AD588TQ/883 - High Precision Voltage Reference | Analog Devices
Référence : AD588TQ/883 ✓ Actif| Qté | Prix unitaire | Total |
|---|---|---|
| 1 | $161.92 | $161,92 |
| 10 | $155 | $1 550,00 |
| 100 | $148 | $14 800,00 |
| 500 | $140 | $70 000,00 |
| 1 000 | $132 | $132 000,00 |
AD588TQ/883 Présentation
A voltage reference is a precision electronic circuit that produces a constant output voltage regardless of load, temperature, or supply variations. It is a fundamental building block in analog and mixed-signal systems, serving as a stable reference for analog-to-digital converters (ADCs), digital-to-analog converters (DACs), and comparators. Voltage references are categorized into series and shunt types; the AD588 is a series reference, which offers lower power consumption and better accuracy than shunt references.
Key features of the AD588TQ/883 include 12-bit absolute accuracy, low temperature coefficient of 3 ppm/°C, and optional fine-trim connections for higher precision. The device operates over a wide supply range and provides both 5V and 10V outputs, which can be programmed via pin strapping. The military-grade temperature range ensures reliable operation in harsh environments.
The AD588 uses a buried Zener diode reference and precision thin-film resistors to achieve its high accuracy. The architecture provides excellent long-term stability and low noise, making it ideal for precision instrumentation and data acquisition systems. The fine-trim capability allows users to adjust the output voltage to meet specific accuracy requirements.
Typical applications include precision data acquisition systems, calibration equipment, and aerospace instrumentation. The AD588TQ/883 is also used in military and aerospace systems where high reliability and accuracy are critical. Its 16-lead CERDIP package provides hermetic sealing, protecting the die from moisture and contaminants.
When designing with the AD588TQ/883, ensure proper decoupling on the input supply and output to maintain stability. The fine-trim pins can be used to adjust output voltage, but care must be taken to avoid introducing noise. The device is available in tube packaging, and pricing is available from authorized distributors.
Alternatives de remplacement direct pour AD588TQ/883 — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec AD588TQ/883 (même facteur de forme et même empreinte) — différant par Output Voltage, Package, Reference Type, RoHS Status, Temperature Coefficient.
Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :
AD588SQ/883B
✅ Remplacement direct✓ En stock
$27 / unité
Voir la fiche technique →AD588BQ
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
AD588TQ/883 Valeurs maximales et caractéristiques électriques
| Type de sortie | Programmable |
| Tension de sortie | 5V, 10V |
| Courant de sortie maximal | 10 mA |
| Plage de tension d'entrée | 10.8V to 36V |
| Temperature Coefficient | 3 ppm/°C |
| Initial Accuracy | 12-bit (0.024%) |
| Boîtier | 16-CDIP (0.300", 7.62mm) |
| Plage de température de fonctionnement | -55°C to +125°C |
| Reference Type | Series |
| Type de montage | Through Hole |
| Statut RoHS | Non-Compliant |
| Lead Free | No |
| Product Category | Voltage References |
| Series | AD588 |
Configuration des broches de AD588TQ/883
| Broche 1 | V+ — Positive supply input |
| Broche 2 | VOUT — Output voltage (5V or 10V) |
| Broche 3 | GND — Ground |
| Broche 4 | TRIM — Fine trim adjustment |
| Broche 5 | NC — No connection |
| Broche 6 | NC — No connection |
| Broche 7 | NC — No connection |
| Broche 8 | NC — No connection |
| Broche 9 | NC — No connection |
| Broche 10 | NC — No connection |
| Broche 11 | NC — No connection |
| Broche 12 | NC — No connection |
| Broche 13 | NC — No connection |
| Broche 14 | NC — No connection |
| Broche 15 | NC — No connection |
| Broche 16 | V- — Negative supply input |
Applications typiques
AD588TQ/883 convient pour 6 applications: Precision Data Acquisition Systems, Military and Aerospace Instrumentation, Calibration and Test Equipment, Industrial Process Control, Medical Imaging Systems, Aerospace Power Management.
Precision Data Acquisition Systems
The AD588TQ/883 provides a stable 5V or 10V reference for high-resolution ADCs and DACs. Its 12-bit absolute accuracy and low temperature coefficient ensure accurate conversions over the military temperature range. The 10 mA output current can drive multiple converter references, and the fine-trim capability allows calibration to meet system accuracy requirements.
Recommandé
Military and Aerospace Instrumentation
The AD588TQ/883 is specified for the full military/aerospace temperature range (-55°C to +125°C) and is packaged in a hermetic CERDIP, making it ideal for avionics, guidance systems, and radar. Its high reliability and stability ensure consistent performance in harsh environments. The 3 ppm/°C temperature coefficient minimizes drift, critical for precision navigation and targeting systems.
Recommandé
Calibration and Test Equipment
The AD588TQ/883 serves as a reference standard in calibration instruments, providing accurate 5V and 10V outputs for verifying other equipment. Its 12-bit absolute accuracy and fine-trim capability allow precise adjustment to NIST-traceable standards. The low noise and high stability make it suitable for metrology applications where repeatability is essential.
Recommandé
Industrial Process Control
In industrial automation, the AD588TQ/883 provides a stable reference for analog I/O modules, ensuring accurate sensor readings and control signals. Its wide supply range and 10 mA output can drive multiple channels. The industrial temperature range variant (AD588BQ) is also available, but the TQ/883 offers extended temperature for harsh environments.
Recommandé
Medical Imaging Systems
The AD588TQ/883 is used in medical imaging equipment such as CT scanners and MRI systems, where precision voltage references are critical for image quality. Its low noise and high stability ensure consistent performance. The military temperature range is not required, but the device's reliability is beneficial for critical medical applications.
Recommandé
Aerospace Power Management
The AD588TQ/883 provides a stable reference for power supply monitoring and control in aerospace systems. Its hermetic package and military temperature range make it suitable for satellite and launch vehicle applications. The 10 mA output can drive supervisory circuits, and the fine-trim allows precise voltage setting for critical rails.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour AD588TQ/883 — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | AD588SQ/883B | AD588BQ | AD588TE/883B |
|---|---|---|---|---|
| Package | 16-CDIP | 16-CDIP | 16-CDIP | LCC-20 |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Output Voltage | 5V, 10V | 5V, 10V | 5V, 10V | 5V, 10V |
| Temperature Coefficient | 3 ppm/°C | 3 ppm/°C | 3 ppm/°C | 1.5 ppm/°C |
| Operating Temperature Range | -55°C to +125°C | -55°C to +125°C | -25°C to +85°C | -55°C to +125°C |
| Maximum Output Current | 10 mA | 10 mA | 10 mA | 10 mA |
| RoHS Compliance | Non-Compliant | Non-Compliant | Non-Compliant | Non-Compliant |
Principaux différenciateurs
- Military temperature range (vs AD588BQ)
- Hermetic CERDIP package (vs AD588ARWZ)
- 12-bit absolute accuracy (vs REF02CPZ)
Notes de conception
The AD588TQ/883 requires a supply voltage between 10.8V and 36V. For 10V output, ensure the input is at least 10.8V plus dropout. Use a low-noise supply and bypass with 0.1uF and 10uF capacitors close to the V+ and V- pins to maintain stability and reduce noise.
For optimal performance, place the AD588TQ/883 on a dedicated ground plane and keep the output trace short and shielded. Use Kelvin connections for the output sense if high accuracy is required. Avoid routing high-frequency signals near the reference to prevent noise coupling.
Do not exceed the maximum output current of 10 mA. The fine-trim pins should be used with precision resistors to avoid introducing errors. Ensure the CERDIP package is handled properly to avoid thermal stress, and verify the pinout against the datasheet before PCB layout.
Informations de conformité
Military-grade component, not RoHS compliant due to lead-based solder. No AEC-Q100 qualification as it is not an automotive part.