AD629BNZ - High Common-Mode Difference Amplifier | Analog Devices
Référence : AD629BNZ ✓ ActifAD629BNZ Présentation
A difference amplifier measures the voltage difference between two inputs while rejecting voltage common to both inputs. In the product hierarchy, the AD629 is a precision difference amplifier within the broader family of current-sense amplifiers, instrumentation amplifiers, and operational amplifiers. This distinction matters in systems where a low-level differential signal must be extracted from a high-voltage bus, motor drive, or power-conversion node.
The AD629BNZ provides a single amplifier channel in an 8-pin PDIP package. Its principal engineering value is the combination of precision difference-amplifier behavior and an exceptionally high common-mode range. This allows a compact measurement chain to observe current or voltage information on high-energy electrical systems while maintaining separation between the useful differential component and the much larger common-mode component.
The manufacturer describes the AD629 as a precision device intended for accurate differential-signal measurement in the presence of common-mode voltages up to 270 V. Unlike a general-purpose operational amplifier connected directly across a high-voltage node, the AD629 is designed around the electrical conditions encountered in high-side current sensing and floating power systems. System-level accuracy still depends on the resistor network, input filtering, supply arrangement, and the common-mode voltage present at the measurement terminals.
Typical uses include motor-control phase current measurement, power-converter current feedback, industrial inverter monitoring, battery-management current sensing, and high-side sensing in systems where the voltage of interest rides on a substantial common-mode potential. In each case, the AD629 converts the differential sensor output into a low-level signal suitable for further amplification, filtering, isolation, or digital conversion.
The main design consideration is to keep input and output grounds, supply rails, and external resistor networks within their rated operating conditions. Signal-path components connected to the high-voltage inputs must have suitable voltage ratings, while the amplifier's supply pins and reference network determine output offset and scaling. PCB layout should preserve differential symmetry so that common-mode rejection and gain accuracy are not degraded by unequal traces or parasitic capacitance.
This product page combines the AD629BNZ device description, package information, manufacturer documentation, sourcing guidance, candidate drop-in alternatives, and practical design considerations. It is intended to help engineers identify whether the AD629BNZ's 8-pin PDIP format and high common-mode capability fit a particular measurement architecture before validating the complete circuit.
Alternatives de remplacement direct pour AD629BNZ — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec AD629BNZ (même facteur de forme et même empreinte) — différant par Package, Mounting Type, Product Type, Common-Mode Input Voltage Range, Differential Gain.
AD629BN
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →AD629ANZ
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →INA117P
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →AD629BNZ Valeurs maximales et caractéristiques électriques
| Product Type | High Common-Mode-Voltage Difference Amplifier |
| Common-Mode Input Voltage Range | Up to ±270 V |
| Number of Channels | 1 channel |
| Differential Input Channels | 1 differential input channel |
| Boîtier | 8-pin PDIP |
| Type de montage | Through-hole |
Guide de configuration des broches du AD629BNZ 8-pin pdip
Configuration des broches du AD629BNZ (boîtier 8-pin pdip). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.
Aucune donnée de brochage détaillée disponible pour AD629BNZ.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
AD629BNZ convient pour 6 applications: High-Side Motor Current Sensing, Power-Converter Current Feedback, Industrial Inverter Phase Monitoring, Battery Pack Current Monitoring, Precision Ground-Referenced Differential Sensing, High-Voltage Test and Measurement.
High-Side Motor Current Sensing
The AD629BNZ fits high-side motor-current measurement when the current-sense amplifier output is referenced to a supply or switching node rather than ground. Its common-mode input range extends to ±270 V, allowing the amplifier to operate near elevated motor-drive voltages while extracting the small differential voltage generated by the current-sense resistor. Place the sensing amplifier close to the shunt to limit pickup from motor-switching noise. The principal trade-off is that the complete measurement chain must remain within the amplifier's supply, input, and common-mode limits. Filter the sense-node input if switching transients are present, and verify offset, gain error, and propagation behavior across the motor operating range before production release.
Recommandé
Power-Converter Current Feedback
The AD629BNZ is appropriate for current-feedback control in power converters where the sensing element is located at a high-voltage switching node. Its ±270 V common-mode capability provides separation between the useful shunt differential voltage and a large common-mode transient, while the difference-amplifier function prevents the converter node from overwhelming the measurement. The amplifier should be positioned close to the shunt and its reference network, with the signal return routed away from high-current paths. Designers must still evaluate the instantaneous switch-node voltage, amplifier supply headroom, and settling requirements at the control-loop bandwidth. A shielded or properly routed ground reference is important because ground displacement can appear directly as output error.
Recommandé
Industrial Inverter Phase Monitoring
The AD629BNZ supports phase-current monitoring in industrial inverters, where each motor terminal can swing rapidly between positive and negative bus voltages. The common-mode range of ±270 V allows one difference-amplifier architecture to handle high-side sensing across such transitions while preserving the differential information from the current sensor. Keep each phase measurement channel symmetrical so that unequal input filtering does not degrade differential accuracy. The output must remain compatible with the controller's input range, and the selected AD629 grade must satisfy the enclosure's temperature requirements. Isolation or attenuation may still be required when the bus voltage exceeds the full operating limits or when the inverter uses a topology outside the device's intended application envelope.
Recommandé
Battery Pack Current Monitoring
The AD629BNZ can measure differential current-sensor signals in battery systems when the monitored conductor is biased above the measurement ground. Its high common-mode range is useful in automotive, industrial, and energy-storage architectures where the battery rail can rise far above the logic supply. The amplifier provides a direct difference-amplifier path rather than requiring the shunt output to be shifted into ground. Design the input network for the battery's transient environment, including surge, load dump, and reverse-current events, and verify that every external high-voltage component has adequate clearance and voltage rating. Calibrate offset and gain at the system's actual sensor temperature because gain and reference errors directly affect current-reporting accuracy.
Recommandé
Precision Ground-Referenced Differential Sensing
The AD629BNZ is useful when a small differential signal must be measured relative to ground but the source remains connected to a high common-mode potential. The common-mode input capability allows the measurement amplifier to reject the shared voltage while preserving the differential component for downstream conversion. In instrumentation-style circuits, maintain equal source impedances and matched input filtering to avoid unintended gain error and common-mode-to-differential conversion. The reference network determines the output offset and should be configured according to the manufacturer application guidance. Although the AD629 is often discussed in high-voltage sensing applications, its precision difference-amplifier behavior also supports laboratory and industrial instrumentation where signal-ground relationships are carefully controlled.
Recommandé
High-Voltage Test and Measurement
The AD629BNZ can serve in test and measurement equipment that monitors a small differential quantity on a high-voltage node. Its range of up to ±270 V common-mode voltage allows a compact front end to measure the difference between two similarly elevated potentials without first reducing both signals to ground level. The test fixture, input cabling, and shunt or sensor must separately satisfy the applicable high-voltage insulation requirements. Keep the analog signal path away from protective-earth and chassis discontinuities, because leakage through contaminated connectors can overwhelm a microvolt-scale differential measurement. The instrument designer should also account for amplifier warm-up, offset calibration, and the frequency response needed by the measurement bandwidth.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour AD629BNZ — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | AD629BN | AD629ANZ | INA117P |
|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Package | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP |
| Product Type | High common-mode-voltage difference amplifier | High common-mode-voltage difference amplifier | High common-mode-voltage difference amplifier | Unity-gain difference amplifier |
| Number of Channels | 1 channel | 1 channel | 1 channel | 1 channel |
Principaux différenciateurs
- Exceptionally wide common-mode measurement capability (vs INA117P)
- Direct same-brand family interchange path (vs AD629BN)
- Single-channel precision difference-amplifier architecture (vs AD629ANZ)
Notes de conception
Do not equate a common 8-pin PDIP outline with automatic electrical compatibility. Before fitting AD629BN, AD629BN, AD629ANZ, or INA117P, compare every terminal function, supply requirement, input range, reference configuration, and output behavior in the applicable manufacturer datasheet. Pay particular attention to whether the reference pin is driven, grounded, or otherwise configured. A PCB that accepts the mechanically correct package can still produce invalid measurements if a high-voltage terminal is connected to the wrong amplifier pin.
Route the two differential inputs as a compact, symmetric pair from the sensing element to the amplifier. Equal input impedances and matched PCB geometry reduce conversion of common-mode voltage into differential error and reduce sensitivity to unequal switching transients. Keep the high-current shunt or sensor connection physically separate from the sensitive output and reference traces. Provide local supply bypassing and a low-impedance return path, while observing the manufacturer's grounding recommendations.
The ±270 V common-mode capability does not imply that the amplifier's supply rails can also be connected to ±270 V. The supply architecture, ground reference, and all connected components must satisfy their own absolute voltage ratings. Verify common-mode voltage during startup, shutdown, overload, and fault conditions, including fast transitions that may not appear in a slow steady-state simulation. Add suitable input attenuation or protection if the circuit can exceed those conditions.
Measurement accuracy depends on the complete resistor and filtering network, not only the AD629BNZ. Use high-quality resistors with suitable temperature coefficients, keep the sense element's Kelvin connections as short as practical, and place filtering close to the amplifier input. If the common-mode signal contains high-frequency switching energy, evaluate differential settling and phase response at the intended control bandwidth. Calibrate offset and gain only after the complete input network has reached thermal equilibrium.
Informations de conformité
The manufacturer identifies the AD629 family as production, but no explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals statement was included for the AD629BNZ ordering suffix. The device is not presented as an AEC-Q100-qualified automotive product.