AD7701AN - 16-Bit Sigma-Delta ADC | Analog Devices | Industrial Sensing
Référence : AD7701AN ✓ ActifAD7701AN Présentation
A sigma-delta ADC is a category of data-converter IC that samples an analog input continuously and converts it into a high-resolution digital value using a modulator and digital filtering. Its architecture belongs to the ADC hierarchy, then data converters, then integrated circuits, and is particularly useful when low noise, limited bandwidth, and excellent resolution matter more than high conversion speed. The AD7701AN is therefore well suited to slowly changing sensor signals rather than high-frequency waveform acquisition.
The principal device characteristics include 16-bit resolution, one analog input, operation as a sigma-delta converter, six-pole Gaussian digital filtering, and output word rates up to 4 kHz. Reference voltages from 1 V to 3 V may be used with little degradation in performance. The manufacturer describes the analog input as being continuously sampled by an analog modulator whose mean output duty cycle is proportional to the input signal.
Internally, the analog modulator converts the input into a low-frequency bit stream. The on-chip digital filter then applies a six-pole Gaussian response and updates the output register with 16-bit binary words. This filtering architecture helps reject broadband noise when the desired signal changes slowly, making the ADC appropriate for precision bridges, resistive sensors, and process-control inputs. Reference and signal-conditioning choices still determine whether the system reaches its intended accuracy.
Typical uses include weighing scales, pressure measurement, temperature sensing, industrial process control, and low-bandwidth instrumentation. In a bridge-based measurement, the AD7701AN can digitize a small differential-style input associated with a load cell when appropriate excitation, reference, and input-conditioning circuitry are used. In process control, its filtered low-rate conversion supports supervisory readings from slowly changing pressure or temperature sensors.
Designers should match the analog input range to the selected reference voltage and preserve the required signal-conditioning accuracy. Reference and input filtering, grounding, digital-interface timing, and the acquisition software must all be evaluated together because digital filtering cannot recover accuracy lost in the analog front end. The manufacturer datasheet should be used for the complete pin-description table and recommended application circuitry.
This product page combines the manufacturer’s converter architecture and package information with practical application guidance, comparison parameters, and sourcing questions. It is designed to help engineers determine whether the AD7701AN’s resolution and conversion rate fit a precision-measurement design before beginning board layout or firmware development.
Alternatives de remplacement direct pour AD7701AN — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
AD7701TQ
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
AD7701ANZ
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
AD7701AN Valeurs maximales et caractéristiques électriques
| Résolution | 16 bit |
| Number of Analog Inputs | 1 input |
| Conversion Architecture | Sigma-delta ADC |
| Maximum Output Word Rate | 4 kHz |
| Digital Filter Response | 6-pole Gaussian |
| Process Technology | LC2MOS |
| Reference Voltage Range | 1 V to 3 V |
| Input Signal Sampling | Continuous |
| Output Data Format | 16-bit binary words |
| Boîtier | 20-pin PDIP |
| Type de montage | Through-hole |
| Statut RoHS | unknown |
| REACH Status | unknown |
| AEC-Q100 Qualification | not_applicable |
Guide de configuration des broches du AD7701AN 20-pin pdip
Configuration des broches du AD7701AN (boîtier 20-pin pdip). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.
Aucune donnée de brochage détaillée disponible pour AD7701AN.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
AD7701AN convient pour 6 applications: Industrial Weighing and Load Measurement, Pressure Transducer Interface, Temperature Monitoring and Control, Process Control Instrumentation, Portable Precision Measurement Instrument, Low-Frequency Sensor Acquisition Module.
Industrial Weighing and Load Measurement
The AD7701AN fits load-cell front ends that require high resolution from a slowly changing mechanical signal. Its 16-bit conversion resolution and six-pole Gaussian digital filter allow a conditioned bridge output to be converted at word rates up to 4 kHz while rejecting noise outside the selected conversion bandwidth. Place the converter behind a low-noise bridge amplifier or instrumentation-amplifier stage, and use a 1 V to 3 V reference derived from a stable source. The main design trade-off is bandwidth: the digital filter improves signal purity but requires sufficient settling time after load changes, so the complete measurement chain must be optimized rather than relying on maximum output rate alone.
Recommandé
Pressure Transducer Interface
The AD7701AN is suitable for pressure sensors whose output changes relatively slowly and needs greater resolution than a conventional low-resolution SAR ADC may provide. The single analog input accepts a suitably conditioned sensor voltage, while the six-pole Gaussian filter reduces broadband noise around the pressure reading. With a reference between 1 V and 3 V, the input network can scale the transducer output into the converter’s supported range. For pneumatic and hydraulic systems, low-noise reference routing, analog grounding, and filter settling are critical because pressure-transducer excitation drift and mechanical vibration can otherwise dominate the measured 16-bit result.
Recommandé
Temperature Monitoring and Control
The AD7701AN can digitize a temperature-derived voltage in industrial monitoring, test equipment, or thermal-control systems. The 16-bit resolution provides fine code spacing, and the continuously sampled sigma-delta architecture is well matched to thermocouple, RTD, or thermistor signals that change gradually. A regulated 1 V to 3 V reference supports the input range, but the sensor interface must compensate for excitation error, cold-junction effects, or bridge nonlinearity as applicable. Configure the digital filter and conversion cycle to provide a stable reading before initiating control action, avoiding extra control lag caused by unnecessarily long settling intervals.
Recommandé
Process Control Instrumentation
The AD7701AN is appropriate for supervisory process measurements such as tank level, flow-derived voltage, or slow process-variable feedback. Its output word rate of up to 4 kHz is substantially higher than the update interval generally needed for many controlled loops, while the six-pole Gaussian filter helps isolate the selected low-frequency signal. The analog input should be conditioned so the full sensor range maps safely into the available reference-based input range. Engineers should treat the converter as the measurement endpoint rather than a complete transmitter: sensor excitation, protection, isolation, calibration, and linearization remain separate design tasks that determine final process accuracy.
Recommandé
Portable Precision Measurement Instrument
The AD7701AN supports portable meters and laboratory instruments that prioritize a precise numerical reading over rapid waveform acquisition. Its 16-bit sigma-delta architecture can resolve small input changes after analog conditioning, and the 20-pin PDIP package remains straightforward to assemble for low-volume or prototype instrumentation. A 1 V to 3 V reference should be selected for low-noise behavior and stability, while the analog input must avoid switching-node interference. Because the converter is designed for continuous low-frequency sampling, firmware can average or digitally process results without requiring a high-speed sampling pipeline. Battery-powered designs must still verify the device’s complete supply-voltage and current-consumption requirements before finalizing the power budget.
Recommandé
Low-Frequency Sensor Acquisition Module
The AD7701AN can form the measurement core of a dedicated sensor-acquisition module for resistive, capacitive, or voltage-based sensor outputs. The one-channel architecture is appropriate when each module serves one slowly varying quantity, and the six-pole Gaussian filter improves rejection of noise outside the selected bandwidth. Designers should provide local analog bypass, a clean reference, and careful grounding between the sensor interface and digital control section. The 16-bit result is valuable only when the preceding amplifier or passive network has lower offset, drift, and noise contributions; otherwise extra converter bits will not improve the complete system measurement.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour AD7701AN — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | AD7701TQ | AD7701ANZ |
|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Package | 20-PDIP | 20-PDIP | 20-PDIP |
| Resolution | 16 bit | 16 bit | 16 bit |
| Conversion Architecture | Sigma-delta ADC | Sigma-delta ADC | Sigma-delta ADC |
| Ordering-Grade Distinction | Standard AD7701AN ordering code | Extended-temperature ordering variant | Related ordering suffix; exact grade definition in the manufacturer ordering table |
Principaux différenciateurs
- High-resolution sigma-delta conversion in a single-input architecture (vs AD7701TQ)
- On-chip Gaussian filtering for low-frequency measurement (vs AD7701ANZ)
- Compact through-hole integration (vs AD7701TQ)
Notes de conception
Keep the reference and analog-input traces short and route them away from digital switching signals. Place input and reference bypass components close to their associated pins, and use a continuous ground plane unless the manufacturer application diagram specifies a particular partitioning strategy. The analog input is continuously sampled, so even modest coupling from digital clocks or interface activity can appear in the filtered result. Confirm the pin assignments in the manufacturer pin-description table before finalizing the 20-pin PDIP footprint.
Do not treat the nominal 16-bit resolution as guaranteed end-to-end accuracy. The practical result is limited by reference accuracy, offset, gain error, analog-front-end noise, input conditioning, and the selected digital-filter settling interval. Design the input range and 1 V to 3 V reference together, then verify the complete measurement chain against the converter’s calibration and noise specifications. This prevents unnecessary front-end gain that magnifies offset and drift along with the intended signal.
Choose the conversion rate and digital-filter configuration from the required signal bandwidth rather than automatically using the maximum 4 kHz word rate. A slower output rate and narrower effective bandwidth can improve rejection of noise and establish the correct settling time for the measurement. Validate the filter behavior in firmware by allowing the configured number of conversion cycles after a sensor, reference, or input-network change before using the new result.
Informations de conformité
No specific RoHS, REACH, lead-free, halogen-free, or conflict-minerals declaration was identified for the exact AD7701AN ordering code. Automotive qualification is not indicated for this standard commercial part.