AD7731BNZ - 24-Bit 6.4 kSPS Sigma-Delta ADC | Analog Devices
Référence : AD7731BNZ ✓ ActifAD7731BNZ Présentation
A sigma-delta ADC is a type of analog-to-digital converter that combines an analog modulator with a digital decimation filter. Its architecture is well suited to low-bandwidth, high-resolution measurements because it converts the analog input into a filtered digital representation with strong rejection of out-of-band noise. The AD7731BNZ extends this architecture with a programmable-gain front end and selectable differential input configurations.
Key features include 24-bit resolution, a 6.4 kSPS sampling rate, three or five analog inputs, and bipolar operation. The integrated analog modulator, programmable digital filter, automatic calibration, synchronous triggering, soft reset, and power-on reset reduce the amount of external signal conditioning and control required. A stated operating-temperature range of -40°C to +85°C supports industrial equipment and laboratory instrumentation.
The AD7731 uses a serial processor interface suitable for communicating with microcontrollers, DSPs, and industrial control systems. Programmable filter settings allow the converter to balance conversion speed against rejection of noise outside the useful measurement bandwidth. This makes filter selection a system-level decision: a narrow bandwidth improves rejection of broadband interference, while a wider bandwidth can shorten the time required to obtain a settled conversion result.
Typical uses include pressure and flow transmitters, temperature measurement bridges, industrial process monitoring, laboratory instrumentation, and precision weighing systems. The device is particularly appropriate when the transducer produces a low-level bipolar signal and the application requires more resolution than a conventional lower-cost successive-approximation ADC provides.
A careful design should account for the reference voltage, analog and digital supply sequencing, input settling time, and the digital filter configuration. Follow the pin-description and application-circuit tables in the manufacturer datasheet when assigning PCB nets, especially for differential inputs, reference connections, and serial interface signals.
This page combines the manufacturer's product description, distributor package and availability details, pricing evidence, comparison data, and practical engineering guidance to support component selection and PCB implementation for the AD7731BNZ 24-bit sigma-delta ADC.
Alternatives de remplacement direct pour AD7731BNZ — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec AD7731BNZ (même facteur de forme et même empreinte) — différant par Input Type, Mounting Type, Package, Sampling Rate.
AD7712ANZ
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →AD7731BNZ Valeurs maximales et caractéristiques électriques
| Converter Type | Sigma-delta ADC |
| Résolution | 24 bit |
| Fréquence d'échantillonnage | 6.4 kSPS |
| Number of Inputs | 3 or 5 |
| Number of Converters | 1 |
| Input Type | Bipolar |
| Architecture | Integrated modulator with programmable digital filter |
| Programmable Gain Front End | Yes |
| Automatic Calibration | Yes |
| Synchronous Triggering | Yes |
| Soft Reset | Yes |
| Power-On Reset | Yes |
| Supply Voltage Range | 2.7 V to 5.25 V |
| Plage de température de fonctionnement | -40°C to +85°C |
| Boîtier | 24-pin PDIP, 7.62 mm width |
| Type de montage | Through-hole |
| Data Interface | SPI and DSP serial interface |
Guide de configuration des broches du AD7731BNZ 24-pin pdip, 7.62 mm width
Configuration des broches du AD7731BNZ (boîtier 24-pin pdip, 7.62 mm width). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.
Aucune donnée de brochage détaillée disponible pour AD7731BNZ.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
AD7731BNZ convient pour 6 applications: Pressure Transmitter Signal Acquisition, Industrial Flow and Differential Pressure Measurement, Temperature and Resistance Bridge Measurement, Precision Laboratory Instrumentation, Load Cell and Weighing Systems, Process Monitoring and Environmental Sensors.
Pressure Transmitter Signal Acquisition
The AD7731BNZ fits pressure-transmitter front ends that deliver a low-level bipolar signal into a process-control instrument. Its programmable-gain analog front end accepts the transducer output without requiring a separate high-resolution conversion stage, while the 24-bit resolution preserves fine measurement detail. The integrated modulator and programmable low-pass filter help reject noise outside the useful pressure-signal bandwidth. For a slow-changing process variable, filtering can be narrowed to improve interference rejection, although the control software must account for the corresponding settling time. Reference stability, excitation-routing errors, input settling, and grounding remain critical because the converter cannot correct analog errors introduced ahead of its inputs.
Recommandé
Industrial Flow and Differential Pressure Measurement
The AD7731BNZ is suitable for flow meters and differential-pressure transmitters that produce small differential signals over a restricted bandwidth. Its 24-bit sigma-delta conversion architecture supports high-resolution measurements, and the programmable gain front end helps align the converter with the transmitter's output range. The selectable digital filter is useful because flow signals often sit near DC while pumps, valves, and electrical drives create broadband interference nearby. Choose filter settings and conversion timing together so the controller receives settled data without adding unnecessary delay. Differential input routing must also minimize thermoelectric effects and ground currents, because those errors can become significant after the converter applies substantial digital gain.
Recommandé
Temperature and Resistance Bridge Measurement
The AD7731BNZ can support precision temperature, strain, and resistance measurements when the sensing element produces a low-level differential signal. Its programmable-gain front end and 24-bit resolution are valuable for resolving small bridge imbalance while the digital filter suppresses frequencies outside the thermal or mechanical measurement band. Synchronous triggering allows the host processor to coordinate conversion timing, and automatic calibration helps reduce offset and gain-related errors. In a practical bridge circuit, excitation noise and reference variation still set the achievable accuracy, so ratiometric measurement and careful analog grounding should be considered. The device should not be selected solely by resolution when sensor settling, excitation stability, or temperature drift dominate the complete measurement chain.
Recommandé
Precision Laboratory Instrumentation
The AD7731BNZ fits laboratory instruments that combine low-level analog input conditioning with accurate digital readout or control. Its 24-bit resolution, 6.4 kSPS maximum conversion rate, and programmable filter provide a flexible balance between measurement resolution and response time. A narrow filter can improve rejection of noise during slow laboratory measurements, while a faster configuration can support monitoring of changing waveforms within the converter's bandwidth. Automatic calibration, synchronous triggering, soft reset, and power-on reset support repeatable system startup and measurement sequencing. Designers should use the manufacturer application circuit to establish reference and power decoupling because instrument accuracy depends on the complete analog chain, not only on the nominal converter resolution.
Recommandé
Load Cell and Weighing Systems
The AD7731BNZ is appropriate for electronic weighing systems where a load-cell bridge produces a small differential signal and the final reading requires high effective resolution. The programmable-gain front end can accommodate the bridge output, while the 24-bit sigma-delta architecture helps separate the slowly changing mechanical signal from mechanical vibration and electrical noise. The programmable digital filter should be selected according to the required settling time and vibration spectrum. Synchronous triggering can coordinate multiple measurements, and automatic calibration supports zero and scale-factor correction. Mechanical mounting, excitation symmetry, input protection, and PCB thermal gradients can dominate real weighing-system errors, so the converter should be integrated into a carefully designed analog and mechanical system.
Recommandé
Process Monitoring and Environmental Sensors
The AD7731BNZ can digitize outputs from environmental, gas, and chemical sensors when the sensor signal is low level, differential, and relatively slow changing. The 24-bit resolution supports fine digital evaluation, while the integrated modulator and programmable filter help isolate the measurement from noise outside the selected bandwidth. Its -40°C to +85°C stated operating range suits many industrial monitoring environments. Calibration routines can be initiated around a conversion for stable readings, and synchronous triggering permits synchronized sampling of multiple channels. However, sensor heaters and electrochemical outputs may introduce wide-band or time-varying disturbances. The final filter rate, analog input configuration, and conversion rate must therefore be tuned to the sensor rather than selected only from the converter's headline specifications.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour AD7731BNZ — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | AD7712ANZ |
|---|---|---|
| Brand | Analog Devices | Analog Devices |
| Package | PDIP-24 | 24-DIP / PDIP-24 |
| Resolution | 24 bit | 24 bit |
| Sampling Rate | 6.4 kSPS | 6.4 kSPS |
| Number of Inputs | 3 or 5 | 3 or 5 |
| Number of Converters | 1 | 1 |
| Data Interface | SPI and DSP serial interface | SPI and DSP |
| Programmable Gain Front End | Yes | Yes |
| Operating Temperature Range | -40°C to +85°C | -40°C to +85°C |
Principaux différenciateurs
- Complete process-control analog front end (vs AD7712ANZ)
- Higher conversion throughput than the lower-rate AD7714 comparison (vs AD7714ANZ-3)
- Broader channel configuration (vs AD7714ANZ-3)
Notes de conception
Place the reference, differential-input, and supply-decoupling components close to their corresponding AD7731BNZ pins, and route the analog ground return without sharing high-current paths with digital or switching circuitry. A sigma-delta converter may reject noise digitally, but PCB leakage, ground movement, and reference coupling occur before conversion. Follow the manufacturer's application schematic and pin-description table, verify the complete 24-pin PDIP footprint, and keep unused inputs in the state recommended by the datasheet.
Treat the converter's differential inputs as a precision analog interface. Keep input traces short, symmetrical, and away from switching nodes, and minimize parasitic capacitance and leakage on high-impedance transducer connections. The programmable digital filter can suppress out-of-band interference but cannot recover information corrupted by input saturation or nonlinear loading. Validate the complete source impedance, excitation network, protection devices, and settling behavior over the intended measurement bandwidth.
Do not select AD7712ANZ solely because both devices use a 24-pin PDIP package. The package comparison supports a drop-in-style path, yet complete substitution still requires verification of supply pins, analog input assignments, reference polarity, interface timing, reset behavior, and register compatibility. A successful PCB fit is not sufficient; run the manufacturer's initialization sequence and compare calibrated readings against the AD7731BNZ across input range, temperature, filter rate, and noise conditions before production release.
Design the analog and digital supplies around the manufacturer's recommended decoupling arrangement and confirm sequencing requirements before connecting external signals. The AD7731BNZ has a listed 2.7 V to 5.25 V supply range, but the complete system may use a 5 V configuration. Keep reference voltage within its specified operating limits and use separate, low-impedance return paths from the reference source so converter load transients do not become measurement error.
Informations de conformité
The manufacturer and distributor product information confirms the product and operating specifications but does not state the requested environmental or material-compliance declarations. Confirm current declarations with Analog Devices before regulatory release.