The Analog Devices ADE7754ARZ is a production polyphase multifunctional energy-metering IC with a serial port, a 4.75 V to 5.25 V supply range, and a 24-pin SOIC package. It performs active-energy, apparent-energy, and RMS measurements for three-phase systems while supporting 3-phase/3-wire and 3-phase/4-wire configurations. According to the verified distributor data, its measurement error is 0.1%, input impedance is 370 kOhm, and typical supply current is 7 mA.

An energy-metering IC is a specialized data-acquisition and signal-processing semiconductor that converts voltage and current waveforms into digital measurements for billing, load monitoring, and power-quality analysis. The ADE7754 belongs to the metering-IC, analog-signal-processing, power-monitoring, and semiconductor hierarchies. Its integrated processing reduces the need for separate analog-to-digital converters, arithmetic logic, and host-side waveform analysis in utility-class energy meters.

Key verified features include reference circuitry, an integrated temperature sensor, current-channel and voltage-channel RMS calculation, active and apparent energy measurement, and a serial communications interface. The manufacturer describes the device as compatible with IEC 687/61036 metering requirements. Its 370 kOhm input impedance supports the analog front-end design, while the 0.1% measurement error provides a concrete accuracy target for energy-meter calibration and validation.

The ADE7754 combines analog input conditioning, measurement engines, calibration paths, registers, and serial-interface logic. This integration lets a meter manufacturer process polyphase signals close to the sensing nodes and send calculated results to a host controller. Digital calibration and serial connectivity can simplify production setup, but firmware and register compatibility must be checked carefully when replacing or redesigning an existing meter platform.

Typical applications include utility meters, industrial power monitors, three-phase energy meters, calibration systems, and digital power-monitoring equipment. Its 24-SOIC package is widely supported by conventional surface-mount assembly, although the narrow 0.295-inch body width requires attention to routing density and assembly constraints.

For a new design, begin with the manufacturer datasheet wiring, input filtering, reference components, grounding, and calibration sequence rather than copying an unrelated meter schematic. Confirm the exact serial protocol, register map, production calibration flow, and analog channel scaling before PCB release.

This page consolidates verified specifications, pricing references, package details, application guidance, and replacement limits. It also distinguishes confirmed drop-in candidates from metering devices that may be only functional alternatives, helping engineers avoid incompatible redesign assumptions.

Alternatives de remplacement direct pour ADE7754ARZ — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

Aucune alternative de remplacement direct disponible pour ce produit.

Demander des alternatives

ADE7754ARZ Valeurs maximales et caractéristiques électriques

Product Type Polyphase multifunctional energy-metering IC with serial port
Supply Voltage Range 4.75 V to 5.25 V
Courant d'alimentation 7 mA
Input Impedance 370 kOhm
Measurement Error 0.1%
Phase Support 3 phase
Wiring Compatibility 3-phase/3-wire and 3-phase/4-wire
Energy Measurements Active energy and apparent energy
RMS Measurements All current and voltage channels
Integrated Temperature Sensor Yes
Reference Circuitry Integrated
Serial Interface Serial port
Metering Compatibility IEC 687/61036 compatible
Boîtier 24-SOIC, 0.295-inch body width
Packaging Tube
Type de montage Surface mount
Manufacturer List Price Starting From 9.48 USD as of 2026-10-21
LCSC Price 19.7075 USD as of 2026-10-21

Guide de configuration des broches du ADE7754ARZ 24-soic, 0.295-inch body width

Configuration des broches du ADE7754ARZ (boîtier 24-soic, 0.295-inch body width). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.

Schéma de brochage du boîtier 24-soic, 0.295-inch body width pour le ADE7754ARZ

Aucune donnée de brochage détaillée disponible pour ADE7754ARZ.

Consultez la fiche technique pour la configuration complète des broches.

Applications typiques

ADE7754ARZ convient pour 6 applications: Three-Phase Utility Energy Meters, Industrial Power Monitoring, Three-Phase Power-Quality Instruments, Energy-Meter Calibration Systems, Digital Load Monitoring, Building Energy Management.

⚡

Three-Phase Utility Energy Meters

The ADE7754ARZ fits utility-class meter front ends that must measure active and apparent energy across three-phase networks. Its verified 0.1% measurement error provides a defined accuracy target, while the 4.75 V to 5.25 V supply range supports a 5 V meter architecture. The integrated reference circuitry, RMS processing, and serial port reduce the amount of external signal-processing hardware. Engineers should follow the manufacturer’s wiring, filtering, and calibration procedure for the selected three-phase/three-wire or three-phase/four-wire configuration.

🏭

Industrial Power Monitoring

ADE7754ARZ is appropriate for industrial equipment that needs local three-phase power measurements without sending raw waveforms to a remote controller. The IC calculates active energy, apparent energy, and RMS values internally, allowing a host processor to read summarized results through the serial interface. Its 370 kOhm input impedance and integrated signal processing help simplify analog conditioning, but the external sensor network still requires suitable protection, filtering, grounding, and calibration.

📊

Three-Phase Power-Quality Instruments

The ADE7754ARZ can serve as the measurement core in compact power-quality instruments that require energy totals and RMS channel data. Its integrated reference, temperature-sensor, and processing functions help establish a repeatable measurement chain close to the analog inputs. Because the verified data does not specify every real-time waveform feature, designers should use the datasheet to confirm harmonic, event, and power-factor requirements before selecting it for a specialized analyzer.

🧪

Energy-Meter Calibration Systems

ADE7754ARZ is suitable for calibration and validation equipment that repeatedly exercises three-phase metering channels under controlled input conditions. Its specified 0.1% measurement error and digital measurement architecture make the device useful as a reference element in a production test fixture, provided the external signal sources and measurement uncertainty are controlled. Calibration firmware should follow the manufacturer’s documented channel, gain, offset, and register procedure to avoid mixing incompatible setup assumptions.

🖥️

Digital Load Monitoring

The ADE7754ARZ supports digital load monitoring designs that need accumulated energy and RMS information from a three-phase supply. Internal processing allows the external controller to focus on display, logging, alarms, and communications rather than reproducing the metering algorithms. The 24-SOIC package is compatible with standard surface-mount assembly, although designers should verify connector spacing, analog routing, and thermal performance around the precision measurement section.

🧩

Building Energy Management

ADE7754ARZ can form the measurement core of a building energy-management product that monitors three-phase loads and records consumption over time. Its active and apparent energy outputs support energy accounting, while RMS measurements provide useful channel-level operating information. A practical implementation should protect the current inputs, maintain clean analog grounding, isolate external communication where required, and reserve space for calibration access and production test points.

What is the ADE7754ARZ used for?
The ADE7754ARZ is a three-phase energy-metering IC used to measure active energy, apparent energy, and RMS values on current and voltage channels. Analog Devices describes integrated reference circuitry, a temperature sensor, and signal-processing capability, while verified distributor data identifies a serial port and 24-SOIC package. It is suited to utility meters and industrial three-phase power monitors requiring accurate digital measurements.
What are the key specifications of ADE7754ARZ that engineers should know?
The ADE7754ARZ operates from 4.75 V to 5.25 V and is specified at 7 mA supply current. Verified data lists a 370 kOhm input impedance and 0.1% measurement error. The device supports three-phase/3-wire and three-phase/4-wire systems, performs active and apparent energy calculations, includes a temperature sensor, and uses a 24-SOIC surface-mount package.
Where can I download the ADE7754ARZ datasheet PDF?
The official ADE7754 datasheet PDF is available from Analog Devices at https://www.analog.com/media/en/technical-documentation/data-sheets/ADE7754.pdf. The manufacturer product page is https://www.analog.com/en/products/ade7754.html. Use the official PDF for the complete pin definitions, electrical characteristics, calibration procedure, serial interface, timing diagrams, and application circuit.
Where can I find the ADE7754ARZ pinout?
The ADE7754ARZ pinout is published in the official Analog Devices ADE7754 datasheet rather than in the short distributor snippets. The verified package is 24-SOIC, so the complete 24-pin diagram should be checked against the selected PCB footprint. Do not infer analog inputs, supplies, serial signals, or reference pins solely from a distributor category listing.
What is the ADE7754ARZ supply voltage and supply current?
The verified ADE7754ARZ operating supply range is 4.75 V to 5.25 V, with a listed supply current of 7 mA. These values are consistent with a 5 V-class precision metering front end. Designers should still use the official datasheet limits, decoupling recommendations, absolute maximum ratings, and tolerance margins when designing the power supply and analog reference network.
Is the ADE7754ARZ compatible with three-phase four-wire meters?
Yes, the verified product description identifies compatibility with both 3-phase/3-wire and 3-phase/4-wire systems. The device is therefore suitable for common polyphase energy-meter architectures when the voltage and current channels are wired and calibrated according to the manufacturer application guidance. The exact channel assignment and scaling must be confirmed in the datasheet.
Where to buy ADE7754ARZ online?
The verified ADE7754ARZ listings are available through DigiKey, Mouser, LCSC, Win Source, and other distributors. DigiKey identifies it as a three-phase meter IC in a 24-SOIC package, and LCSC shows a price from 19.7075 USD as of 2026-10-21. Availability and lead time can change, so confirm the current listing before purchasing.
What is the price of ADE7754ARZ?
LCSC lists ADE7754ARZ from 19.7075 USD as of 2026-10-21, while Analog Devices lists a starting list price of 9.48 USD for the product family. Distributor pricing can differ by quantity, inventory, and contract. The price shown in this page is a reference snapshot, not a guaranteed quotation.
What is the lead time for ADE7754ARZ?
The provided web data confirms distributor availability pages but does not state a current contractual lead time for ADE7754ARZ. DigiKey’s listing indicates that ordering information is available, but inventory and lead time should be checked directly with the selected distributor. Because the device is listed as production on the Analog Devices product page, it is not appropriate to infer immediate availability solely from the product-page wording.
Is ADE7754ARZ in stock?
Stock status is distributor-dependent and is not guaranteed by the manufacturer product page. The verified LCSC result reports the part as in stock, while other sources provide ordering and pricing pages without a uniform inventory quantity. Check the selected distributor’s live stock and lead-time fields before committing a production schedule.
ADE7754ARZ vs ADE7758ARWZRL - which is better for a three-phase meter?
ADE7754ARZ and ADE7758ARWZRL are not automatically interchangeable, even though both are Analog Devices energy-metering devices. The provided comparison result identifies ADE7758ARWZRL as a related comparison part, but it does not establish identical pinout, register, calibration, or measurement behavior. Choose ADE7754ARZ when its verified 24-SOIC package, 0.1% measurement error, and serial-port architecture match the existing design.
What is the best drop-in replacement for ADE7754ARZ?
The verified search data does not identify five or more true pin-compatible drop-in replacements for ADE7754ARZ. A replacement should match the 24-SOIC footprint, analog channel arrangement, serial interface, register map, calibration method, and electrical performance. ADE7758ARWZRL may be functionally related, but it cannot be treated as a drop-in replacement without a verified pin and firmware compatibility review.
Can another metering IC replace ADE7754ARZ without PCB changes?
Only a candidate explicitly verified as pin-to-pin compatible can replace ADE7754ARZ without PCB changes. Similar energy-metering functionality is insufficient because channel assignments, reference inputs, serial timing, calibration registers, and package pins can differ. The provided evidence confirms ADE7754ARZ’s 24-SOIC package but does not verify a cross-brand pin-compatible equivalent.
What can replace ADE7754ARZ?
ADE7754ARZ can be replaced only after confirming package, pin mapping, supply range, analog inputs, serial protocol, energy-register behavior, and calibration requirements. ADE7758ARWZRL is a related Analog Devices comparison candidate, but the supplied data does not prove drop-in compatibility. Treat it as a design-review candidate rather than a confirmed replacement.
Is ADE7754ARZ suitable for industrial power monitoring?
Yes, ADE7754ARZ is suitable for three-phase industrial power monitoring when the measurement accuracy and calibration requirements fit the system. Its verified 0.1% measurement error, 370 kOhm input impedance, RMS calculations, and energy measurements make it appropriate for compact metering platforms. The design must still include appropriate current and voltage sensing, filtering, protection, isolation, and factory calibration.
How should ADE7754ARZ be calibrated in a meter design?
Calibrate ADE7754ARZ by following the manufacturer’s prescribed gain, offset, reference, and measurement sequence rather than applying generic trimpot settings. The device integrates measurement channels and digital processing, so production calibration should establish stable channel scaling before energy registers are accepted. Verify the result under the intended three-phase/three-wire or three-phase/four-wire wiring configuration.

Données de référence d'ingénierie pour ADE7754ARZ — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose ADE7754ARZ when the design needs a production three-phase metering IC with active and apparent energy measurement, RMS calculations, integrated reference circuitry, a temperature sensor, and serial connectivity. Its verified 0.1% measurement error, 370 kOhm input impedance, and 24-SOIC package make it appropriate for utility meters, industrial monitors, and energy-management equipment. ADE7758ARWZRL may be worth reviewing for related Analog Devices designs, but the supplied data does not prove pin, register, or firmware compatibility, so it is not a confirmed drop-in replacement. No cross-brand drop-in alternatives are listed because the verified search results did not establish one. For a new board, prioritize the manufacturer’s reference circuit, calibration sequence, and analog layout; for an existing board, verify every pin and register before purchasing alternatives.

Comparaison avec les alternatives

Paramètre Ce produit
Package 24-SOIC
Brand Analog Devices
Supply Voltage Range 4.75 V to 5.25 V
Supply Current 7 mA
Input Impedance 370 kOhm
Measurement Error 0.1%
Phase Support 3 phase
Serial Interface Serial port
Integrated Temperature Sensor Yes
Price Reference From 19.7075 USD as of 2026-10-21

Principaux différenciateurs

  • Integrated three-phase metering functionality (vs ADE7758ARWZRL)
  • Defined measurement accuracy target (vs ADE7758ARWZRL)
  • Established package and supply class (vs Cross-brand replacement candidates)

Notes de conception

Use the manufacturer’s reference schematic and pinout as the authority for the analog channels, reference circuitry, supplies, and serial signals. Route voltage and current inputs away from digital return paths, keep the precision analog ground continuous, and place filtering components close to their associated pins. The 24-SOIC footprint is narrow, so verify courtyard clearance and assembly rules before committing the board outline.

Design the ADE7754ARZ supply for the verified 4.75 V to 5.25 V operating range and decouple the IC according to the manufacturer’s requirements. Avoid routing measurement current through digital supply paths, and account for supply-current noise during calibration. A stable reference and clean supply are especially important because energy-meter errors can propagate through the calibration and register chain.

Keep voltage and current sensing paths short, shielded from switching nodes, and protected against transients. Validate the external resistor dividers, shunt or current-transformer interface, filtering, and grounding against the selected three-phase/three-wire or three-phase/four-wire topology. Do not infer input scaling from the distributor summary; use the manufacturer’s channel and calibration guidance before releasing production boards.

A metering IC can be functionally similar without being a drop-in replacement. Before substituting ADE7754ARZ or accepting ADE7754ARZ as a replacement, compare pin names, analog-channel order, serial timing, register addresses, calibration constants, energy-register behavior, and supply sequencing. The supplied cross-reference results do not prove a compatible replacement, so a firmware and hardware review is mandatory.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

The supplied snippets mention IEC 687/61036 compatibility but do not provide verified RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declarations for ADE7754ARZ.

Données vérifiées le : 2026-10-21 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

ADE7754ARZ ADE7754 datasheet PDF Analog Devices ADE7754ARZ ADE7754ARZ 3 phase energy metering IC ADE7754ARZ 24-SOIC ADE7754ARZ utility meter application ADE7754ARZ vs ADE7758ARWZRL ADE7754ARZ drop-in replacement ADE7754ARZ price and availability ADE7754ARZ pinout and calibration

Composants & termes associés

Analog Devices ADE7754ARZ ADE7754 ADE7758ARWZRL energy-metering IC polyphase metering analog signal processing semiconductor ADC active energy apparent energy RMS measurement three-phase/3-wire three-phase/4-wire serial port reference circuitry temperature sensor 370 kOhm input impedance 0.1% measurement error 4.75 V to 5.25 V supply 24-SOIC IEC 687/61036 industrial power monitoring utility energy meter calibration system
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ