ADM3051BRWZ Présentation
A CAN transceiver is a physical layer device that interfaces between a CAN protocol controller and the differential bus lines (CANH and CANL). It converts the digital signals from the controller into differential signals for transmission over the twisted-pair bus and vice versa. The transceiver is a critical component in the CAN network hierarchy, which spans from the application layer down to the physical layer. The ADM3051BRWZ specifically implements the physical layer, providing the necessary drive strength, receiver sensitivity, and protection features required for robust communication in harsh industrial environments.
Key features of the ADM3051BRWZ include its compliance with ISO 11898, which ensures interoperability with other standard CAN devices. The device supports data rates up to 1 Mbps, making it suitable for high-speed industrial control applications. Its short-circuit protection on CANH and CANL against shorts to power or ground in 24 V systems enhances robustness in industrial settings where wiring faults are common. The slope control feature allows the designer to reduce electromagnetic interference (EMI) by controlling the slew rate of the output signals, which is particularly useful in applications with stringent EMC requirements. Thermal shutdown protection prevents damage from excessive power dissipation, and the low current standby mode reduces power consumption when the bus is idle.
From a technical perspective, the ADM3051BRWZ is designed to handle the electrical stresses of industrial environments. Its differential output voltage and receiver input sensitivity are optimized for reliable communication over long bus lengths (up to 1 km) and with many nodes. The device's common-mode input range accommodates ground potential differences between nodes, which is common in distributed systems. The transceiver's propagation delay and loop delay are carefully controlled to ensure timing compliance with the CAN protocol, even at 1 Mbps. The device also features a silent mode (via the RS pin) that disables the transmitter, allowing for bus monitoring without driving the bus.
Typical applications for the ADM3051BRWZ include industrial automation, building automation, automotive electronics (non-safety critical), and any system requiring robust CAN communication. In industrial automation, it is used in PLCs, sensors, and actuators to provide reliable data exchange over long distances. In building automation, it enables communication between HVAC controllers, lighting systems, and access control panels. The device's high-speed capability and robustness make it ideal for these applications.
When designing with the ADM3051BRWZ, it is important to consider proper bus termination (typically 120 ohms at each end) and to use twisted-pair cabling to minimize EMI. The slope control pin (RS) can be used to adjust the slew rate for EMI reduction, but this also limits the maximum data rate. For 1 Mbps operation, the slope control should be set to high-speed mode (RS connected to ground). Additionally, the VCC supply should be decoupled with a 100 nF capacitor close to the VCC pin to ensure stable operation.
Alternatives de remplacement direct pour ADM3051BRWZ — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec ADM3051BRWZ (même facteur de forme et même empreinte) — différant par Package, Data Rate, Operating Temperature Range, RoHS Status, Short-Circuit Protection.
Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :
ADM3051BRWZ-REEL7
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
ADM3051BRWZ-REEL
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
ADM3051BRWZ-RL7
✅ Remplacement direct✓ En stock
$1.12 / unité
Voir la fiche technique →ADM3051BRWZ-RL
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
ADM3051BRWZ-REEL7
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
ADM3051BRWZ-REEL
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
ADM3051BRWZ-RL7
✅ Remplacement direct✓ En stock
$1.12 / unité
Voir la fiche technique →ADM3051BRWZ-RL
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
ADM3051BRWZ Spécifications
| Protocol | CAN |
| Number of Drivers | 1 |
| Number of Receivers | 1 |
| Supply Voltage (VCC) | 5 V |
| Débit de données | 1 Mbps |
| Compliance | ISO 11898 |
| Number of Nodes | 110 or more |
| Short-Circuit Protection | CANH/CANL to power/ground in 24 V systems |
| Slope Control | Yes (RS pin) |
| Arrêt thermique | Yes |
| Standby Mode | Low current |
| Boîtier | 14-lead SOIC (BRWZ) |
| Plage de température de fonctionnement | -40°C to +125°C |
| RoHS Compliant | Yes |
| Type de montage | Surface Mount |
Configuration des broches de ADM3051BRWZ
| Broche 1 | TXD — Transmit data input |
| Broche 2 | GND — Ground |
| Broche 3 | VCC — Supply voltage (5 V) |
| Broche 4 | RXD — Receive data output |
| Broche 5 | RS — Slope control / standby mode |
| Broche 6 | CANH — CAN high bus line |
| Broche 7 | CANL — CAN low bus line |
| Broche 8 | GND — Ground |
Applications typiques
ADM3051BRWZ convient pour 6 applications: Industrial Automation, Building Automation, Automotive Electronics, Medical Equipment, Transportation Systems, Test and Measurement.
Industrial Automation
The ADM3051BRWZ is ideal for industrial automation networks where reliable, high-speed CAN communication is required. Its compliance with ISO 11898 and support for up to 1 Mbps data rates ensure robust data exchange between PLCs, sensors, and actuators. The device's short-circuit protection and wide operating temperature range (-40°C to +125°C) make it suitable for harsh factory floor environments. With the ability to connect 110 or more nodes, it supports large-scale automation systems. The slope control feature helps reduce EMI, which is critical in industrial settings with sensitive equipment. Overall, the ADM3051BRWZ provides the physical layer reliability needed for industrial control systems.
Recommandé
Building Automation
In building automation, the ADM3051BRWZ enables communication between HVAC controllers, lighting systems, and access control panels over a CAN bus. Its high-speed capability (1 Mbps) allows for quick response times in real-time control loops. The device's low current standby mode reduces power consumption when the bus is idle, contributing to energy efficiency. The robust protection features, including short-circuit protection and thermal shutdown, ensure long-term reliability in building environments. The ADM3051BRWZ's compliance with ISO 11898 ensures interoperability with other building automation devices. Its compact SOIC package is suitable for space-constrained controllers.
Recommandé
Automotive Electronics
The ADM3051BRWZ is suitable for non-safety-critical automotive applications such as body control modules, infotainment systems, and diagnostic interfaces. Its compliance with ISO 11898 ensures compatibility with standard automotive CAN networks. The device operates over a wide temperature range (-40°C to +125°C), making it suitable for under-hood and cabin environments. The short-circuit protection on CANH and CANL protects against wiring faults common in automotive harnesses. The slope control feature can be used to reduce EMI, which is important for meeting automotive EMC standards. The ADM3051BRWZ's high-speed capability supports the increasing data rates required by modern vehicles.
Recommandé
Medical Equipment
The ADM3051BRWZ can be used in medical equipment that requires reliable CAN communication, such as patient monitoring systems, diagnostic devices, and laboratory equipment. Its high-speed data rate (1 Mbps) ensures timely data transfer for real-time monitoring. The device's robust protection features, including short-circuit protection and thermal shutdown, enhance safety and reliability in medical environments. The wide operating temperature range allows operation in various clinical settings. The ADM3051BRWZ's compliance with ISO 11898 ensures interoperability with other medical devices using CAN. Its low power standby mode is beneficial for battery-powered portable medical devices.
Recommandé
Transportation Systems
The ADM3051BRWZ is used in transportation systems such as railway control, traffic management, and fleet management. Its high-speed capability (1 Mbps) supports real-time control and monitoring. The device's robustness, including short-circuit protection and wide temperature range, ensures reliable operation in outdoor and harsh environments. The ability to connect 110 or more nodes allows for large-scale networks in transportation infrastructure. The slope control feature helps reduce EMI, which is important in electrically noisy environments. The ADM3051BRWZ's compliance with ISO 11898 ensures compatibility with standard transportation communication protocols.
Recommandé
Test and Measurement
In test and measurement equipment, the ADM3051BRWZ provides reliable CAN communication for data acquisition and control. Its high-speed data rate (1 Mbps) enables fast data transfer, which is critical for accurate measurements. The device's low current standby mode reduces power consumption in portable instruments. The robust protection features ensure reliable operation in laboratory and field environments. The ADM3051BRWZ's compliance with ISO 11898 ensures compatibility with other test equipment using CAN. Its compact SOIC package is suitable for space-constrained designs.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour ADM3051BRWZ — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | ADM3051BRWZ-REEL7 | ADM3051BRWZ-REEL | ADM3051BRWZ-RL7 | ADM3051BRWZ-RL |
|---|---|---|---|---|---|
| Package | 14-lead SOIC | 14-lead SOIC | 14-lead SOIC | 14-lead SOIC | 14-lead SOIC |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Data Rate | 1 Mbps | 1 Mbps | 1 Mbps | 1 Mbps | 1 Mbps |
| Supply Voltage | 5 V | 5 V | 5 V | 5 V | 5 V |
| ISO 11898 Compliance | Yes | Yes | Yes | Yes | Yes |
| Short-Circuit Protection | Yes | Yes | Yes | Yes | Yes |
| Slope Control | Yes | Yes | Yes | Yes | Yes |
| Operating Temperature Range | -40°C to +125°C | -40°C to +125°C | -40°C to +125°C | -40°C to +125°C | -40°C to +125°C |
Principaux différenciateurs
- High-speed CAN transceiver with 1 Mbps data rate (vs ADM3052BRWZ)
- Short-circuit protection on CANH and CANL against shorts to power/ground in 24 V systems (vs ADM3052BRWZ)
- Slope control for reduced EMI (vs ADM3052BRWZ)
Notes de conception
Place a 100 nF decoupling capacitor as close as possible to the VCC pin (pin 3) and ground. Additionally, a 10 µF bulk capacitor is recommended on the VCC rail to handle transient currents. The CANH and CANL lines should be routed as a differential pair with controlled impedance (typically 120 ohms) to minimize reflections and EMI. Keep the trace lengths short and avoid stubs to maintain signal integrity.
Use the slope control (RS pin) to adjust the slew rate of the CAN output signals. For high-speed operation (1 Mbps), connect RS to ground to select the high-speed mode. For lower data rates, a resistor from RS to ground can be used to reduce EMI. This is particularly important in applications with strict EMC requirements, such as automotive and industrial environments.
Ensure proper bus termination: place a 120 ohm resistor at each end of the CAN bus to match the characteristic impedance of the twisted-pair cable. Incorrect termination can cause signal reflections and communication errors. Also, avoid connecting more than 110 nodes without considering the total bus load and capacitance. The ADM3051BRWZ is not isolated; for applications requiring galvanic isolation, consider the ADM3052BRWZ or ADM3053BRWZ.
Informations de conformité
RoHS compliance is indicated in the datasheet. Other compliance details are not explicitly stated in the provided data.